Empowering Scientific Discovery

Guangzhou Yitongxing Instrumentation & Metering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPicco
Instrument TypePortable Colorimetric Water Quality Analyzer
Power Supply9 V Alkaline Battery (40 h continuous operation)
Operating Temperature0–40 °C
Operating Humidity30–90 % RH
Dimensions (Instrument)190 × 110 × 55 mm
Dimensions (Carrying Case)270 × 225 × 80 mm
Keypad3-button polycarbonate membrane, ESD-protected
Sample CellWaterproof, integrated cuvette chamber
Optical SystemTemperature-compensated LED light source
Auto Power-OffYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesto
OriginGermany
ModelTesto 3008
Operating Temperature Range (Flue Gas Probe)0–400 °C (extendable to 800 °C)
Dynamic Pressure Range0–1500 Pa (±1.5 %)
Static Pressure Range−30 to +30 kPa (±3.0 %)
Total Pressure Range−30 to +30 kPa (±3.0 %)
Pre-meter Pressure Range−30 to +30 kPa (±2.5 %)
Wet-Bulb Pressure Range−30 to +30 kPa (±3.0 %)
Pre-meter Temperature−30 to +50 °C (±1.5 °C)
Host Temperature−30 to +50 °C (±1.5 °C)
Dry-Bulb Temperature0–150 °C (±1.5 °C)
Wet-Bulb Temperature0–150 °C (±1.5 °C)
Flue Gas Temperature0–400 °C (±3.0 °C
Volumetric Flow Rate5–50 L/min (±2.5 %)
Isokinetic Flow Tracking Accuracy±5 %, response time < 8 s
Sampling Time Range0–999 min 59 s (±1.0 ‰)
Accumulated Sample Volume0–999999 L (±2.5 %)
Moisture Content0–45 % (±5.0 %)
Dimensions (L×W×H)430 × 200 × 370 mm
Weight11.5 kg
Power SupplyAC 220 V ± 22 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelOxiTop-IS6
Instrument TypeLaboratory BOD Analyzer
Measurement PrinciplePressure Difference Method (Manometric)
Measurement Range2–4000 mg/L
Detection Limit2 mg/L
Accuracy±5%
Incubation Duration5-day standard test
Repeatability±3%
Operating Temperature+5 to +50 °C
DisplayDual-digit 7-segment LED (10 mm), 00–50 range
Pressure Sensing Range500–1100 hPa
Accuracy of Pressure Reading±1 digit (±3.55 hPa)
Power Supply2×CR2430 lithium batteries (280 mAh total)
Max Current Draw25 mA (during display activation)
Safety RatingCategory III per IEC 61010-1
Ingress ProtectionIP54 per DIN 40050
Dimensions69 mm H × 70 mm Ø
ComplianceDIN 38409-52 (BODₙ determination)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Instrument TypeRadiation Dose Rate & Spectral Analyzer
Energy Resolution<65% FWHM @ 5.16 keV (²³⁹Pu)
Energy Linearity≤±1% (60 keV–2.0 MeV)
Long-Term Stability≤±1% over 8 h
Operating Temperature+5°C to +35°C
Relative Humidity≤80% at 30°C
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Detectorφ40 mm × 1 mm Si-PIN X-ray detector
InterfaceRS-232 serial communication
SoftwarePHA18 Pulse Height Analysis software (Windows 98 compatible)
Quality SystemISO 9001 certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelphotoLab 7000
Instrument TypeLaboratory Water Quality Analyzer
Detection ParametersAmmonia-N, Volatile Phenols, COD, Heavy Metals
Wavelength Range190–1100 nm (UV-VIS)
Optical Resolution±1 nm (typ.), <0.5 nm (FWHM)
Photometric Accuracy±0.003 E (E < 0.600), ±0.5% (0.600 < E < 2.000)
Scan Speed700–2000 nm/min
Cuvette CompatibilityAutomatic barcode recognition for 10 mm, 20 mm, and 50 mm rectangular cuvettes
Data Storage5,000 measurements, 500 spectra, 400 kinetic curves
Built-in Methods>200 pre-validated methods (incl. free ammonia, CO₂, SAC, color)
Softwarephotolab® Database & Color Library, AQA (Analytical Quality Assurance) tools, GLP-compliant audit trail
Interfaces1× USB-A, 1× USB-B, 1× Ethernet
Power SupplyUniversal AC adapter (100–240 VAC) or 12 V DC automotive battery operation
Operating Temperature+10 °C to +35 °C
Storage Temperature−25 °C to +65 °C
Dimensions & Weight404 × 197 × 314 mm, approx. 4.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelinoLab Multi 9430
Instrument TypeLaboratory Water Quality Analyzer
Measurable ParameterspH, mV (ORP), Conductivity, Resistivity, Salinity, Dissolved Oxygen (DO), Turbidity, Ion-Selective Electrode (ISE) Concentration
ConnectivityDigital Smart Probe Interface (No Cable Required)
DisplayBacklit Graphic LCD with Antimicrobial Keypad
Probe ManagementQSC (Quality Sensor Control) & CMC (Continuous Measurement Control)
Data StorageUp to 10,000 measurement sets
ComplianceDesigned for ISO/IEC 17025-compliant labs
Added to wishlistRemoved from wishlist 0
Add to compare
Brandtesto
OriginGermany
Modeltesto 370
Instrument TypePortable Flue Gas Analyzer
Accuracy (Indication Error)< ±2% of full scale
Repeatability< ±2% of full scale
Response Time (T90)≤90 s
Long-Term Stability< ±2% of full scale
Measurable GasesCO, NO, N₂O, NO₂, NH₃, CH₄, HCl, SO₂, CO₂, H₂O, O₂
CalibrationZero calibration using ambient air only
Gas Supply RequirementNone (no instrument air required)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBH3105E
Instrument TypePortable
Instrument ClassNeutron Dose Rate Meter
Measured MediumGaseous Environment
Detector Type⁶Li-Glass Scintillator
Radiation TypeNeutron
Measurement Range0.1 µSv·h⁻¹ to 100.0 mSv·h⁻¹
Sensitivity5 cps per µSv·h⁻¹
Energy ResponseThermal neutrons to 14 MeV
γ-Ray Rejection Ratio>100:1 in 10 mGy·h⁻¹ ¹³⁷Cs field
Angular Dependence±25% over 0°–±90°
Intrinsic Error–50% to +100%
Typical Measurement Uncertainty±15%
Response Time20 s
Power Consumption≤500 mW
ComplianceIEC 61005, CMC Certified (China Metrology Accreditation), GB/T 10257–2001, Patent No. ZL92225959.3
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesto
OriginGermany
TypePortable Flue Gas Analyzer
Measurement Accuracy<5%
Repeatability<2%
Response Time<90 s
Stability<5%
Measured GasesO₂, CO, NO, NO₂, SO₂
Optional SensorsCO₂ (IR), H₂S
Sampling Flow Rate1.0 L/min (regulated)
Data Storage Capacity250,000 values
Operating Temperature Range–0 °C to +1000 °C (with high-temp probe)
Differential Pressure Range–200 to +200 hPa
IP RatingIP40
Weight4.8 kg
Dimensions330 × 128 × 438 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck
OriginGermany
Manufacturer TypeAuthorized Distributor
Product OriginImported
ModelMerckoquant
Instrument TypeLaboratory Water Quality Analyzer
Target AnalytesAmmonia-Nitrogen, Nitrate, Phosphate
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMillipore
OriginGermany
ModelNOVA 60
Instrument TypeOnline Water Quality Analyzer
Measurable ParametersCOD, Heavy Metals, Ammonia-Nitrogen (NH₄-N), Cyanide
Key FeaturesIntegrated photometric measurement platform with 12-wavelength LED optical system (240–820 nm), 126 pre-programmed methods covering 50 water quality parameters, 1000-test data storage, compatibility with 16 mm tubes and 10/20/50 mm cuvettes, temperature-compensated optics, battery-powered (9 V, 40 h continuous operation)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelMulti9310
Instrument TypeLaboratory Benchtop Meter
Temperature Range0–80 °C
pH Range0.000–14.000, Accuracy: ±0.002
Dissolved Oxygen (DO)0.00–20.00 mg/L, Accuracy: ±0.5%
Conductivity10 μS/cm–2000 mS/cm, Accuracy: ±0.5%
Turbidity0–4000 FNU, Accuracy: ±2%
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS (China Nuclear Control Systems)
OriginBeijing, China
ModelBH1227
Instrument TypeLaboratory-Based Liquid Activity Meter
Measurement MediumAqueous Samples
Detector TypePlastic Scintillator (ST-1221) with CR120 PMT
Measurement CapabilitySimultaneous Total Alpha and Total Beta Activity Concentration
Detection Efficiencyβ: 0.5×10⁻²–3×10⁻² Bq (10–40 mBq·L⁻¹)
α5×10⁻⁴ Bq (5–20 mBq·L⁻¹)
Anti-coincidence ShieldingST401 Plastic Scintillator + Three CR119 PMTs (Efficiency >99%)
Shielding75 mm Lead + 15 mm Steel Enclosure (Modular Two-Section Design)
Counting Area OptionsΦ30 mm (177.5 px²), Φ45 mm (397.5 px²), Φ52 mm (525 px²)
ComplianceMeets GB/T 11682–2003 (Chinese National Standard for Low-Background Alpha/Beta Counters, Grade II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNC (China Nuclear Control System)
OriginBeijing, China
ModelBH1216III
Instrument TypeLaboratory-grade dual-channel liquid alpha/beta spectrometer
Detector TypePlastic scintillator (ST-1221 main
Measurement MediumAqueous samples
Detection Efficiencyα ≥88% (²³⁹Pu, 2π geometry, Φ30 mm), β ≥55% (⁹⁰Sr–⁹⁰Y, 2π, Φ20 mm)
Background Count Rateα ≤0.005 cm⁻²·min⁻¹, β ≤0.15 cm⁻²·min⁻¹
Minimum Detectable Activityα = 5×10⁻³ Bq, β = 1×10⁻² Bq
Anti-coincidence Efficiency>99%
Shielding100 mm lead + 10 mm steel (total mass ≈500 kg)
Operating Temperature5–35 °C ±2 °C
Humidity≤85% RH at 30 °C
Dimensions605 × 541 × 1244 mm
Weight~500 kg
ComplianceMeets GB/T 11682–2021 (Chinese National Standard for Low-Background Alpha/Beta Counters, Level II)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelZK1101 Portable Multi-Channel Gamma Spectrometer
Instrument TypePortable Gamma Spectrometer
Measurement MediumSolid Samples
Detector Options2″ & 3″ NaI(Tl) Scintillation Detectors
Spectral LengthSoftware-Selectable (256, 512, 1024, or 2048 Channels)
Energy Resolution≤7% at 662 keV (¹³⁷Cs)
Channel Capacity2³²−1 (4,294,967,295 counts per channel)
Long-Term Stability≤1% channel shift over 8 h continuous operation
Battery Life>8 h on integrated rechargeable Li-ion battery
Display7-inch capacitive touchscreen
Data StorageMicroSD card (pre-installed, high-capacity)
ConnectivityUSB 2.0 for PC data transfer
SoftwareEmbedded real-time analysis firmware with lifetime free updates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesto
OriginGermany
ModelTESTO340
Instrument TypePortable Flue Gas Analyzer
Indication Error< ±5%
Repeatability< ±5%
Response Time< 40 s
Stability< ±5%
Measurable GasesSO₂, CO, COlow, NO, NOlow, NO₂, O₂
Differential Pressure & Flow Velocity MeasurementBuilt-in
Sensor ArchitectureModular, 3 Expandable Sensor Slots (O₂ standard
Fuel Database10 Predefined + 10 User-Defined Fuels
Data InterfaceUSB to easyEmission PC Software
ComplianceDesigned for EN 50379-1/-2, EN 15545, VDI 3862, and applicable EPA Method 6C/7E prerequisites
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS (China Nuclear Control System)
ModelBH1324F
Detector TypeNaI(Tl) Scintillation Spectrometer
Energy Range50 keV – 2.0 MeV
Energy Resolution≤7.0% FWHM at 662 keV (with imported low-potassium Φ75×75 mm NaI(Tl) detector)
Background Count Rate≤160 cpm (50 keV–2.0 MeV)
Energy Linearity≤±1% (50 keV–2.0 MeV)
System Stability≤±1% over 8 h
MCA Channels512 / 1024 / 2048 / 4096 (software-selectable)
Max Counts per Channel2²⁴−1
Integral Nonlinearity≤±0.1% (99.5% full scale)
Differential Nonlinearity≤±1% (99.5% full scale)
Channel Drift≤±1 channel over 8 h
HV Supply0–1500 V, manually adjustable, current limit 2 mA with overload/short-circuit protection
LV SupplyOvervoltage, overload and short-circuit protected
Preamplifier Gain0–160×, fixed shaping time 1 µs (optimized for NaI(Tl))
ShieldingLead castle (NG401-261), attenuation factor ≥80 (50 keV–2.0 MeV)
SoftwareUMS38 (MCA emulation & acquisition), WIN-NaI (gamma spectral analysis), fully compatible with Windows 98/Me/2000/XP/NT
CommunicationRS-232 DMA interface, 912 kbps data transfer rate, no ISA slot required
Calibration SourcesCertified ²²⁶Ra, ²³²Th, ⁴⁰K single-nuclide standards + mixed standard (NIM traceable)
ComplianceISO 9001 certified manufacturing
Detection Limit for Radon (activated charcoal method)6 Bq/m³ (average ambient air concentration)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
TypeImported Instrument
ModelMAC100ECO
Manufacturer RoleAuthorized Distributor
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelMulti350i
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS (China Nuclear Control System)
OriginBeijing, China
ModelFD125
Detection PrincipleZnS(Ag)-based Scintillation Counting
Measurement TargetsRadon-222 (²²²Rn), Thoron-220 (²²⁰Rn), and Radium-226 (²²⁶Ra) in air, water, ore, and underground environments
Scintillation ChamberDual hemispherical acrylic chambers coated with ZnS(Ag)
Background Count Rate≤100 cps (unexposed chamber)
Leak Rate≤1.33×10³ Pa/10 min at residual pressure of 1.33×10⁴ Pa
Repeatability Error≤±10% under optimal conditions
Environmental Operating Range0–45°C, up to 95% RH
Power Supply+9–10 V DC for amplifier
Weight16 kg (excluding scaler unit)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelBH3103C
Instrument TypePortable Dose Rate Meter
Radiation TypeX-ray and Gamma (γ) Radiation
Detector TypePhotomultiplier Tube (PMT)
Measurement Range(1–10,000) × 10⁻⁸ Gy/h
Energy Response25 keV–48 keV (±40% max deviation)
Angular Response≤ ±15% (relative to max response, ¹³⁷Cs source, 0–150°)
Cosmic Ray Response±15% (vs. RS-111 ionization chamber)
Inherent Dose Rate Indication Error≤ ±10%
Operating Temperature−10 °C to +40 °C
Power Consumption~400 mW
BatteryNi-MH rechargeable
Environmental ComplianceDesigned for field-deployable environmental and occupational radiation monitoring per IEC 60846-1:2014 and ISO 4037-3:2019 reference conditions
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNC (China Nuclear Control System)
OriginBeijing, China
ModelFJ427A1
Instrument TypeLaboratory TLD Reader
Measurement PrincipleThermoluminescence (TL) Readout
Radiation Typesβ, γ, X-ray, and thermal neutron (via appropriate TLD phosphors)
DetectorPhotomultiplier Tube (PMT), operating voltage range: −400 V to −1000 V
Sample Form CompatibilitySolid dosimeters (square chips, discs, rods, powder)
Dose Range0.000–9999 arbitrary units (calibrated in µGy–Gy via TL phosphor-specific calibration)
Linearity Range100 µGy – 4 Gy (for JR1152A LiF:Mg,Ti chips irradiated with ⁶⁰Co γ-rays)
Linearity Deviation≤ ±10% within specified range
Heating ProgramThree-stage linear ramp (preheat, readout, anneal)
max total duration500 s
preheatRT → 500 °C at max rate
readoutvariable ramp 0–40 °C/s, temp range up to 500 °C
annealramp to 500 °C at max rate
Programmable Parameters5 independent parameter sets (including ramp profile, PMT HV, background offset, reference light source count rate, calibration factor, real-time clock)
Background SubtractionAutomatic, performed every 30 min during operation
Sensitivity Stability≤ ±5% over 8-h continuous operation
ComplianceDesigned per GB 10264–1988 (Chinese National Standard for Thermoluminescent Dosimetry Systems)
Physical Dimensions445 mm (W) × 205 mm (D) × 420 mm (H)
Net Weight22 kg
Power SupplyAC 220 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMerck Millipore
OriginGermany
ModelProve
Instrument TypeLaboratory Water Quality Analyzer
Detection Capacity180 water quality parameters
Wavelength Range190–1,100 nm (UV-Vis)
Light SourcesTungsten-halogen lamp (Prove100), Pulsed xenon lamp (Prove300/Prove600)
Spectral Bandwidth4 nm (Prove100), 1.8 nm (Prove300/Prove600)
Cuvette Compatibility16 mm round tubes
DisplayResistive touchscreen (Prove100/300), P-cap glass capacitive touchscreen (Prove600)
Language Support28 built-in languages
AQA LevelsAQA 1, AQA 2, pipette accuracy verification
Barcode IntegrationFull QR-code support for reagent lot, expiry, calibration data, and method traceability
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing
Manufacturer TypeDistributor
Origin CategoryDomestic
QuotationUpon Request
Instrument TypeDosimeter / Dose Rate Meter
Measurement Range0–100 μGy·h⁻¹
Angular Response (¹³⁷Cs)0°–120° (±25%), 90°–180° (±35%)
Energy Response50 keV–3 MeV (±20%)
Cosmic Ray Response (vs. RSS-111 reference ionization chamber)±15%
Dose Rate Accuracy vs. Theoretical Calculation±10%
Drift After 8-h Continuous Operation at Room Temperature≤±7%
Total Error (−10°C to +40°C)≤±30%
Operating Temperature−10°C to +40°C
Relative Humidity≤90% at +30°C ±2°C
Power SupplySix No. 1 dry cells
Console Dimensions180 mm × 113 mm × 155 mm
Probe Dimensions210 mm × 120 mm × 45 mm
Console Weight~2 kg
Show next