| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | Testo 3008 |
| Operating Temperature Range (Flue Gas Probe) | 0–400 °C (extendable to 800 °C) |
| Dynamic Pressure Range | 0–1500 Pa (±1.5 %) |
| Static Pressure Range | −30 to +30 kPa (±3.0 %) |
| Total Pressure Range | −30 to +30 kPa (±3.0 %) |
| Pre-meter Pressure Range | −30 to +30 kPa (±2.5 %) |
| Wet-Bulb Pressure Range | −30 to +30 kPa (±3.0 %) |
| Pre-meter Temperature | −30 to +50 °C (±1.5 °C) |
| Host Temperature | −30 to +50 °C (±1.5 °C) |
| Dry-Bulb Temperature | 0–150 °C (±1.5 °C) |
| Wet-Bulb Temperature | 0–150 °C (±1.5 °C) |
| Flue Gas Temperature | 0–400 °C (±3.0 °C |
| Volumetric Flow Rate | 5–50 L/min (±2.5 %) |
| Isokinetic Flow Tracking Accuracy | ±5 %, response time < 8 s |
| Sampling Time Range | 0–999 min 59 s (±1.0 ‰) |
| Accumulated Sample Volume | 0–999999 L (±2.5 %) |
| Moisture Content | 0–45 % (±5.0 %) |
| Dimensions (L×W×H) | 430 × 200 × 370 mm |
| Weight | 11.5 kg |
| Power Supply | AC 220 V ± 22 V, 50 Hz |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | testo 370 |
| Instrument Type | Portable Flue Gas Analyzer |
| Accuracy (Indication Error) | < ±2% of full scale |
| Repeatability | < ±2% of full scale |
| Response Time (T90) | ≤90 s |
| Long-Term Stability | < ±2% of full scale |
| Measurable Gases | CO, NO, N₂O, NO₂, NH₃, CH₄, HCl, SO₂, CO₂, H₂O, O₂ |
| Calibration | Zero calibration using ambient air only |
| Gas Supply Requirement | None (no instrument air required) |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Type | Portable Flue Gas Analyzer |
| Measurement Accuracy | <5% |
| Repeatability | <2% |
| Response Time | <90 s |
| Stability | <5% |
| Measured Gases | O₂, CO, NO, NO₂, SO₂ |
| Optional Sensors | CO₂ (IR), H₂S |
| Sampling Flow Rate | 1.0 L/min (regulated) |
| Data Storage Capacity | 250,000 values |
| Operating Temperature Range | –0 °C to +1000 °C (with high-temp probe) |
| Differential Pressure Range | –200 to +200 hPa |
| IP Rating | IP40 |
| Weight | 4.8 kg |
| Dimensions | 330 × 128 × 438 mm |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | TESTO340 |
| Instrument Type | Portable Flue Gas Analyzer |
| Indication Error | < ±5% |
| Repeatability | < ±5% |
| Response Time | < 40 s |
| Stability | < ±5% |
| Measurable Gases | SO₂, CO, COlow, NO, NOlow, NO₂, O₂ |
| Differential Pressure & Flow Velocity Measurement | Built-in |
| Sensor Architecture | Modular, 3 Expandable Sensor Slots (O₂ standard |
| Fuel Database | 10 Predefined + 10 User-Defined Fuels |
| Data Interface | USB to easyEmission PC Software |
| Compliance | Designed for EN 50379-1/-2, EN 15545, VDI 3862, and applicable EPA Method 6C/7E prerequisites |
| Origin | Germany |
|---|---|
| Type | Imported Instrument |
| Model | MAC100ECO |
| Manufacturer Role | Authorized Distributor |
| Pricing | Available Upon Request |