Empowering Scientific Discovery

Guangzhou Yitongxing Instrumentation & Metering Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelFH1048A
PriceUpon Request
Gain
Gain Stability≤±0.03% over 8 h continuous operation
Integral Nonlinearity≤0.5% (with 1 kΩ load, 2 V output)
Input Impedance≥500 kΩ
Rise Time≤30 ns
Operating Temperature0–50 °C
Relative Humidity≤90% at 40 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelTXB Series
Instrument TypePrecision Laboratory Balance
Maximum Capacity6200 g
Readability0.01 g / 0.1 g / 1 g (model-dependent)
Repeatability≤ 0.01 g (for 0.01 g models) / ≤ 0.1 g (for 0.1 g models) / ≤ 1 g (for 1 g models)
Linearity±0.01 g to ±0.2 g
Typical Stabilization Time1–2 s
Pan Size110 mm or 160 mm (model-dependent)
CalibrationExternal
ComplianceDesigned for GLP/GMP environments with audit-ready documentation support
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuitai
OriginShanghai, China
ModelLRH150FN
Temperature Range0–65 °C
Temperature Uniformity±1.0 °C (at 25 °C, empty chamber)
Temperature Fluctuation±0.3 °C (high temp), ±0.5 °C (low temp)
Temperature Resolution0.1 °C
Chamber ConstructionMirror-finish stainless steel with rounded semi-circular corners
Air CirculationAdjustable-speed JAKEL tube-flow fan + proprietary ducted airflow system
Humidity ControlPassive internal moisture management via automatic condensate venting
RefrigerantCFC-free and HCFC-free refrigeration system
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelAP135W
Instrument TypeUltra-Micro Balance
Maximum Capacity135 g
Readability0.01 mg (10 µg)
Repeatability0.05 mg
CalibrationInternal
ComplianceISO/IEC 17025, USP <41>, ASTM E898, GLP/GMP-ready
ConnectivityUSB interface for data export and peripheral integration
Operating Environment18–26°C, 30–70% RH (non-condensing)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNCS
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Product OriginDomestic (China)
ModelBH1218
PricingUpon Request
Gain Range5–750× (continuously adjustable)
Long-term Gain Stability≤0.1% (over 8 h)
Temperature Coefficient of Gain≤0.015%/°C
Integral Nonlinearity≤0.2%
Input-Referred Noise≤15 µV RMS
Overload RecoveryRecovers to within 2% of baseline at 2.5× nominal pulse width after 200× overload
Input PolarityPositive or Negative
Output PolarityPositive
Output Impedance50 Ω
Shaping Time Constants0, 0.5, 1, 2, 3, 4, 5, 6 µs
Operating Temperature0–50 °C
Relative Humidity≤90% at +40 °C
Power Supply±24 V / 30 mA, ±12 V / 10 mA
Power Consumption2 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuitai
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelER35S
Price RangeUSD 700–1,400 (FOB Shanghai)
Heating Power2400 W
Maximum Operating Temperature400 °C
Temperature Uniformity±10 °C across heating zone
Plate Dimensions300 × 500 mm
Heating Zone Dimensions180 × 380 mm
DisplayDigital LED
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHuitai
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelDZF6000
PricingAvailable Upon Request
DisplayLarge LCD Screen
Temperature RangeRT+10°C to 250°C
Temperature Uniformity±1°C
Temperature Resolution0.1°C
Ultimate Vacuum≤133 Pa
Heating ConfigurationInternal Heating
Shelf Capacity2 Removable Shelves
Shelf ControlIndependent Temperature Control per Shelf
Vacuum IndicationAnalog Vacuum Gauge
Vacuum RegulationManual (Non-Controllable)
Standard AccessoriesBuilt-in Vacuum Pump & Lower Cabinet (DZF-6090/6210/6500 only)
Air CirculationProprietary Ducted Airflow System with Automatic Moisture Exhaust
ControllerMicroprocessor-Based with Timer (1–9999 min)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Import StatusImported
ModelS160, S160D
Temperature RangeAmbient +5°C to 60°C
Temperature Uniformity±0.3°C
Temperature Stability (at 37°C)±0.1°C
Effective Volume60 L
Internal Dimensions450 × 380 × 380 mm
External Dimensions600 × 390 × 390 mm
Net Weight11.2 kg
Power Supply230 V / 50 Hz, 350 W
Control OptionsAnalog (S160) or Digital LCD (S160D)
Safety Cut-off72°C automatic thermal shutdown
Optional AccessoriesAcrylic base plate (SI60/1), Powder-coated shelf (SI60/2)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelPicco
Instrument TypePortable Colorimetric Water Quality Analyzer
Power Supply9 V Alkaline Battery (40 h continuous operation)
Operating Temperature0–40 °C
Operating Humidity30–90 % RH
Dimensions (Instrument)190 × 110 × 55 mm
Dimensions (Carrying Case)270 × 225 × 80 mm
Keypad3-button polycarbonate membrane, ESD-protected
Sample CellWaterproof, integrated cuvette chamber
Optical SystemTemperature-compensated LED light source
Auto Power-OffYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
TypePrecision Balance
ModelsTX223L, TX323L, TX2202L, TX3202L, TXB222L, TXB422L, TXB622L, TXB621L, TXB2201L, TXB4201L, TXB6201L, TXB6200L
Weighing Range220 g – 6200 g
Readability0.001 g – 1 g
Pan SizeØ110 mm or 167(W)×181(D) mm or Ø160 mm
Power SupplyAC adapter (TX/TXB series) or AC + rechargeable/dry-cell batteries (TXB series, up to ~40 h operation)
InterfaceRS-232C with built-in Windows Direct Transfer software
ComplianceGLP/GMP-ready with audit trail support via EP-80 printer integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandTesto
OriginGermany
ModelTesto 3008
Operating Temperature Range (Flue Gas Probe)0–400 °C (extendable to 800 °C)
Dynamic Pressure Range0–1500 Pa (±1.5 %)
Static Pressure Range−30 to +30 kPa (±3.0 %)
Total Pressure Range−30 to +30 kPa (±3.0 %)
Pre-meter Pressure Range−30 to +30 kPa (±2.5 %)
Wet-Bulb Pressure Range−30 to +30 kPa (±3.0 %)
Pre-meter Temperature−30 to +50 °C (±1.5 °C)
Host Temperature−30 to +50 °C (±1.5 °C)
Dry-Bulb Temperature0–150 °C (±1.5 °C)
Wet-Bulb Temperature0–150 °C (±1.5 °C)
Flue Gas Temperature0–400 °C (±3.0 °C
Volumetric Flow Rate5–50 L/min (±2.5 %)
Isokinetic Flow Tracking Accuracy±5 %, response time < 8 s
Sampling Time Range0–999 min 59 s (±1.0 ‰)
Accumulated Sample Volume0–999999 L (±2.5 %)
Moisture Content0–45 % (±5.0 %)
Dimensions (L×W×H)430 × 200 × 370 mm
Weight11.5 kg
Power SupplyAC 220 V ± 22 V, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelOxiTop-IS6
Instrument TypeLaboratory BOD Analyzer
Measurement PrinciplePressure Difference Method (Manometric)
Measurement Range2–4000 mg/L
Detection Limit2 mg/L
Accuracy±5%
Incubation Duration5-day standard test
Repeatability±3%
Operating Temperature+5 to +50 °C
DisplayDual-digit 7-segment LED (10 mm), 00–50 range
Pressure Sensing Range500–1100 hPa
Accuracy of Pressure Reading±1 digit (±3.55 hPa)
Power Supply2×CR2430 lithium batteries (280 mAh total)
Max Current Draw25 mA (during display activation)
Safety RatingCategory III per IEC 61010-1
Ingress ProtectionIP54 per DIN 40050
Dimensions69 mm H × 70 mm Ø
ComplianceDIN 38409-52 (BODₙ determination)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginBeijing, China
Manufacturer TypeAuthorized Distributor
Instrument TypeRadiation Dose Rate & Spectral Analyzer
Energy Resolution<65% FWHM @ 5.16 keV (²³⁹Pu)
Energy Linearity≤±1% (60 keV–2.0 MeV)
Long-Term Stability≤±1% over 8 h
Operating Temperature+5°C to +35°C
Relative Humidity≤80% at 30°C
Power SupplyAC 220 V ±10%, 50 Hz ±1 Hz
Detectorφ40 mm × 1 mm Si-PIN X-ray detector
InterfaceRS-232 serial communication
SoftwarePHA18 Pulse Height Analysis software (Windows 98 compatible)
Quality SystemISO 9001 certified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelphotoLab 7000
Instrument TypeLaboratory Water Quality Analyzer
Detection ParametersAmmonia-N, Volatile Phenols, COD, Heavy Metals
Wavelength Range190–1100 nm (UV-VIS)
Optical Resolution±1 nm (typ.), <0.5 nm (FWHM)
Photometric Accuracy±0.003 E (E < 0.600), ±0.5% (0.600 < E < 2.000)
Scan Speed700–2000 nm/min
Cuvette CompatibilityAutomatic barcode recognition for 10 mm, 20 mm, and 50 mm rectangular cuvettes
Data Storage5,000 measurements, 500 spectra, 400 kinetic curves
Built-in Methods>200 pre-validated methods (incl. free ammonia, CO₂, SAC, color)
Softwarephotolab® Database & Color Library, AQA (Analytical Quality Assurance) tools, GLP-compliant audit trail
Interfaces1× USB-A, 1× USB-B, 1× Ethernet
Power SupplyUniversal AC adapter (100–240 VAC) or 12 V DC automotive battery operation
Operating Temperature+10 °C to +35 °C
Storage Temperature−25 °C to +65 °C
Dimensions & Weight404 × 197 × 314 mm, approx. 4.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWTW
OriginGermany
ModelinoLab Multi 9430
Instrument TypeLaboratory Water Quality Analyzer
Measurable ParameterspH, mV (ORP), Conductivity, Resistivity, Salinity, Dissolved Oxygen (DO), Turbidity, Ion-Selective Electrode (ISE) Concentration
ConnectivityDigital Smart Probe Interface (No Cable Required)
DisplayBacklit Graphic LCD with Antimicrobial Keypad
Probe ManagementQSC (Quality Sensor Control) & CMC (Continuous Measurement Control)
Data StorageUp to 10,000 measurement sets
ComplianceDesigned for ISO/IEC 17025-compliant labs
Added to wishlistRemoved from wishlist 0
Add to compare
BrandShimadzu
OriginJapan
ModelAUW120D / AUW220D / AUW320D
Maximum Capacity200 g
Readability0.1 mg
Repeatability±0.1 mg
Weighing Pan Diameter80 mm
Dimensions (W×D×H)220 × 330 × 310 mm
Weight7 kg
Power Consumption7 VA
Operating Temperature5–40 °C
Sensitivity Drift±2 ppm/°C (10–30 °C, PSC OFF or ON)
Stabilization Time≤3 s
Linearity Error±0.2 mg
Standard Deviation≤0.1 mg
InterfaceRS-232, Direct PC Connection via USB-to-RS232 cable
ComplianceGLP/GMP/ISO-compliant calibration reporting
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelWFX220
Instrument TypeFlame and Graphite Furnace AAS
MonochromatorPlane Grating
Optical SystemSingle-Beam
DetectorPhotomultiplier Tube (PMT)
Background CorrectionAutomatic Deuterium Lamp Background Correction
Spectral Resolution0.2 nm
Sensitivity≤0.03 µg/mL for Cu (Flame), ≤0.4 pg for Cd (Graphite Furnace)
Relative Standard Deviation (RSD)≤0.5%
Detection Limit≤0.003 µg/mL for Cu (Flame), ≤0.4 pg for Cd (Graphite Furnace)
Baseline Stability≤0.003 µg/mL (Flame Cu), ≤0.4 pg (Graphite Furnace Cd)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKETT
OriginJapan
ModelPB-1D3
Measurement PrincipleElectrical Resistance
Sample TypesPaddy Rice, Brown Rice, Milled Rice, Barley, Wheat, Rye
Moisture RangePaddy Rice: 11–35%
Brown/Milled Rice11–20%
Barley/Wheat10–40%
Rye10–20%
Accuracy±0.1% (at ≤20%), ±0.5% vs. 105°C Oven-Drying Reference Method
Display128×64 Dot-Matrix LCD, Resolution: 0.1%
Temperature CompensationAutomatic Thermistor-Based Correction
Power SupplyAC 100 V (50/60 Hz) or Four 1.5 V AA Batteries
Dimensions & Weight250 × 240 × 125 mm, 3.5 kg
AccessoriesSample Pan, 15% Calibration Standard, Measuring Spoon, Hand Grinder Handle, Cleaning Brush, Power Cord, Instruction Manual
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBeifen Ruili
OriginBeijing, China
ModelMAS-100
Detection PrinciplePurge-and-Trap GC-Cold Vapor Atomic Fluorescence Detection (GC-AFD)
ComplianceHJ 977–2018
Detector TypeIntegrated Miniaturized Cold Vapor Atomic Fluorescence Detector (AFD)
Column CompatibilityCapillary GC columns
Auxiliary Detectors SupportedFID, ECD, TCD, FPD, TSD
Mercury SpeciationMethylmercury, Ethylmercury
Sample MatrixAqueous solutions
Derivatization ReagentSodium Tetrapropylborate (NaBPr₄)
Trapping MediumTenax® sorbent tube
Carrier GasArgon
Post-Detector Mercury CaptureGold-coated Wire Trap with Active Vacuum Pump
Optical DesignMulti-stage stray-light suppression fluorescence cell
High-Temperature Module950 °C pyrolysis with nano-scale thermal insulation
Footprint<120 mm × 100 mm × 80 mm (AFD unit only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCNOPTEC
OriginChongqing, China
ModelBDS500
Optical SystemOTICS Infinity-Corrected Achromatic Optics
Magnification Range40×–600×
Eyepieces10× Wide-Field, High-Eyepoint Plan Eyepieces (Field Number Φ22 mm)
ObjectivesLong Working Distance Infinity-Plan Achromatic Objectives (4×, 10×, 20×, 40×) and Phase Contrast Objectives (4×, 10×, 20×, 40×)
Observation TubeHinged Trinocular Tube with Interpupillary Adjustment (48–76 mm), Dual-Mode Beam Splitter (100% viewing / 20% viewing + 80% imaging)
Camera PortC-Mount Options (1×, 0.75×, 0.5×)
NosepieceInternal-Positioning Quintuple Objective Turret
Focus MechanismCoaxial Coarse/Fine Focus
StageMechanical Stage (210 × 241 mm Platform
CondenserFour-Position Phase Contrast Condenser (NA 0.4, WD 45 mm, Vertical Adjustment)
IlluminationKöhler Illumination with 12 V/50 W Halogen or 5 W LED (100–240 V AC Input)
Fluorescence ModuleDC 100 W Mercury Lamp (OSRAM) or 5 W LED Excitation Source
Smart IR SensorAutomatic Lamp Power-Down After 10 Minutes of User Absence
Digital Imaging InterfaceDV/TP Series Digital Camera Systems
Added to wishlistRemoved from wishlist 0
Add to compare
Brandtesto
OriginGermany
Modeltesto 370
Instrument TypePortable Flue Gas Analyzer
Accuracy (Indication Error)< ±2% of full scale
Repeatability< ±2% of full scale
Response Time (T90)≤90 s
Long-Term Stability< ±2% of full scale
Measurable GasesCO, NO, N₂O, NO₂, NH₃, CH₄, HCl, SO₂, CO₂, H₂O, O₂
CalibrationZero calibration using ambient air only
Gas Supply RequirementNone (no instrument air required)
Added to wishlistRemoved from wishlist 0
Add to compare
OriginGermany
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
PricingUpon Request
Measurement Principle90° Nephelometric Scattering
Light SourceTungsten Lamp (Turb 550) / Infrared LED (Turb 550 IR)
Range0.01–1000 NTU, Auto-ranging
Resolution0.01 NTU (0.00–9.99), 0.1 NTU (10.0–99.9), 1 NTU (100–1000)
Accuracy±2% of reading or ±0.01 NTU
Repeatability<±1% of reading or ±0.01 NTU
CalibrationAuto 1–3-point with user-definable intervals
Response Time3 s
DisplayDual-line LCD with special character support
Sample Cell28 × 70 mm round glass vial
Sample Volume25 mL
InterfaceRS232 serial output
Real-time Clock & CalendarIntegrated
GLP ComplianceCalibration due-date alert, operator ID logging, measurement timestamping
Dimensions (L×W×D)250 × 290 × 110 mm
Operating Temperature10–40 °C
Power Supply90–250 VAC via external transformer
CertificationsCE, UL, cUL, TÜV/GS
Standard KitUniversal power adapter, three blank cuvettes, English operating manual, quick-reference guide
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBettersize
OriginLiaoning, China
ModelBeNano 90 Zeta
Particle Size Range (DLS)0.3 nm – 15 μm
Zeta Potential RangeNo Practical Limitation
Electrophoretic Mobility Range> ±20 μm·cm/V·s
Conductivity RangeUp to 260 mS/cm
pH Range2–12 (compatible with aqueous & low-ionic-strength media)
Temperature Control Range−10 °C to +110 °C
Temperature Accuracy±0.1 °C
Sample Volume (DLS mode)3 µL (capillary cell) / 0.75 mL (standard cuvette)
Detection Angles90° (size), 12° (zeta)
Laser Source50 mW solid-state laser, 671 nm
DetectorAPD (Avalanche Photodiode)
Correlator4000-channel digital correlator, 10¹¹ dynamic linear range
Optical Path StabilityPassive thermal stabilization, no daily alignment required
Data OutputHydrodynamic diameter (Dₕ), polydispersity index (PDI), zeta potential distribution, electrophoretic mobility, diffusion coefficient (D), intensity/volume/number-weighted size distributions
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0