Empowering Scientific Discovery

Hangzhou Yangyi Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
ManufacturerYes
Country of OriginDomestic (China)
ModelHWP09-10S
QuotationUpon Request
Operating Environment(-5–45) °C, <95% RH
Detection MethodNear-Infrared (NIR)
Spectral Response Range760–1100 nm
Spectral Response Frequency5000 Hz
Ambient Temperature Range(-10–+60) °C
Ambient Temperature Accuracy±0.5 °C
Ambient Humidity Range(5–95)% RH
Ambient Humidity Accuracy±5.0% RH
Combustion Detection Response Time≤6 ms
Ignition Distance Measurement Range15–90 cm
Burner Positioning Accuracy±1 mm
Timing Resolution±0.01 s
Minimum Actuation Duration5 s
Ignition SourceGas-fired igniter
Aerosol Can OrientationMotorized vertical/inverted repositioning
Compatible Can DimensionsHeight 120–400 mm, Diameter 30–80 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelHWP11-10S
PriceUpon Request
Operating Temperature(-5 to 45) °C
Relative Humidity Range5–95 %RH
Flame Height Detection Range0–235 mm
Flame Height Resolution5 mm
Flame Detection Response Time≤6 ms
Ambient Temperature Measurement Range(-10 to +60) °C
Ambient Temperature Accuracy±0.5 °C
Ambient Humidity Accuracy±5.0 %RH
Ignition MethodGas-powered igniter
Timing Accuracy±0.01 s
Sample Support Plate DiameterØ150 mm
Support Plate MaterialHigh-Temperature Quartz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelHWP10-10S
PricingUpon Request
Operating Environment(-5 to 45) °C, <95% RH
Ambient Temperature Range-10 to +60 °C
Ambient Temperature Accuracy±0.5 °C
Ambient Humidity Range5–95% RH
Ambient Humidity Accuracy±5.0% RH
Flame Detection Response Time≤6 ms
Differential Pressure Range-5 to +5 kPa
Pressure Measurement Accuracy±0.1% FS
Spectral Response Range760–1100 nm (Near-Infrared)
Spectral Response Frequency5000 Hz
Timing Accuracy±0.01 s
Timing Resolution0.1 s
Ignition SourceStandardized candle flame
Test Chamber DimensionsØ600 mm × 720 mm (200 dm³ volume)
Aerosol Can OrientationMotorized dual-axis positioning (vertical/inverted)
Compatible Can DimensionsHeight 120–400 mm, Diameter 30–80 mm
Nozzle-to-Chamber DistanceAdjustable from 25 to 100 mm
Residual Liquid Collection TrayRemovable stainless-steel drip pan
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Country of OriginChina
ModelHWP19-10S
PricingUpon Request
Operating Temperature Range−5 °C to 45 °C
Relative Humidity Limit<95% RH
Ignition MethodWireless Electronic Remote Ignition (30 m range)
Timer Resolution0.1 s
Ambient Temperature Measurement Range−10 °C to +60 °C
Ambient Temperature Accuracy±0.5 °C
Ambient Humidity Range5–95% RH
Ambient Humidity Accuracy±5.0% RH
Test Chamber Dimensions30 cm × 30 cm
Camera Resolution300,000 pixels
Wireless Video Transmission Distance100 m (line-of-sight)
Fire Suppression Cover Dimensions32 cm × 32 cm × 5 cm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelHWP04-10S
PricingUpon Request
Operating Environment(-5–45)°C, <95% RH
Channel CapacityStandard 2 channels, customizable up to 8
Temperature Control RangeAmbient to 98°C
Temperature Control Accuracy≤±0.5°C
Temperature Fluctuation≤±0.3°C
Temperature Uniformity±0.5°C
Heating Tube MaterialSUS316 stainless steel
Bath Tank MaterialStainless steel
Timing Range0–35 days
Timing Accuracy±0.01 s
Time Display Resolution1 minute
Sample Vessel Volume3000 mL (effective volume: 2000 mL)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0