| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | ≤0.5 °C |
| Temperature Control Range | RT to 300 °C |
| Temperature Tracking Rate | 0.02–13 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Nail Penetration Stroke | Software-Configurable |
| Current Handling Capacity (Charge/Discharge Electrodes) | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BAC-1000A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | RT to 300 °C (–25 °C with optional low-temp module) |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Needle Penetration Stroke | Programmable |
| Current Capacity (Charge/Discharge Electrodes) | ±1000 A |
| Compliance Standards | GB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Model | BAC-800A |
| Compliance | GB/T 36276–2023, UL 9540A, SAE J2464-R2009, ASTM E1981–98(2012), UL 1973, SN/T 3078.1–2012, SAND99-0497, FreedomCAR SAND 2005-3123 |
| Adiabatic Chamber Dimensions | Ø800 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall–Sample Temperature Differential | ≤1 °C |
| Temperature Control Range | RT to 300 °C (with optional low-temperature module down to –25 °C) |
| Temperature Tracking Rate | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Puncture Stroke | Software-Configurable |
| Current Capacity of Charging/Discharging Electrode Posts | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermal Flow DSC |
| Sample Capacity | Single-sample |
| Temperature Range | –90 °C to 550 °C (with optional imported high-performance mechanical cryocooler) |
| Cooling Method | Mechanical refrigeration + air cooling |
| Heating/Cooling Rate | 0.05–200 °C/min (heating), 0.1–100 °C/min (cooling) |
| Temperature Accuracy | ±0.1 °C (In), Precision: ±0.02 °C (In) |
| Baseline Drift | ≤100 µW (–50–300 °C, no baseline correction) |
| Baseline Repeatability | ≤40 µW |
| Peak Noise (Heat Flow) | <8 µW |
| Enthalpy Accuracy | ±0.8% (In), Precision: ±0.08% (In) |
| Indium Peak Height/FWHM | ≥20.0 mW/K |
| Data Acquisition Rate | 50 Hz |
| Heat Flow Range | ±750 mW |
| Gas Control | 3-channel mass-flow-controlled atmosphere (inert/oxidizing, static/dynamic, 0–300 mL/min) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | ATC 300A |
| Instrument Type | Bomb Calorimeter |
| Ignition Method | Cotton Thread & Ignition Wire |
| Temperature Resolution | 0.0001 °C |
| Test Mode | Isothermal |
| Test Duration | ≤15 min (Standard Method), ≤10 min (Rapid Method) |
| Calorific Value Range | ≤34,000 J |
| Heat Capacity Precision | ≤0.10% |
| Heat Capacity Drift | ≤0.20% |
| Oxygen Bomb Max Pressure | 240 bar |
| Bomb Material | Stainless Steel & Hastelloy (Corrosion-Resistant) |
| Data Storage Capacity | ≥10,000 Tests |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TAC-500A |
| Instrument Type | Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Control Range | Ambient to 500 °C |
| Temperature Detection Threshold | 0.005–0.02 °C/min |
| Temperature Tracking Rate | 0.005–40 °C/min |
| Temperature Display Resolution | 0.001 °C |
| Maximum Pressure Rating | 20 MPa |
| Pressure Resolution | 1 kPa |
| Sample Cell Volume | 8 mL |
| Sample Cell Materials | Stainless Steel (standard), Titanium or Hastelloy (optional) |
| Phi Factor | ≤1.35 |
| Interface | USB or RJ45 |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | ≤3000 W |
| Dimensions | 620 × 470 × 670 mm |
| Weight | ~78 kg |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420R |
| Measurement Mode | Adiabatic Calorimetry |
| Adiabatic Chamber Dimensions | 420 × 520 mm (L × W) |
| Temperature Control Range | RT+5°C to 300°C (optional low-temp module down to −25°C) |
| Temperature Resolution | 0.001°C |
| Chamber Temperature Stability | ±0.05°C |
| Self-Heating Detection Sensitivity | 0.02–0.05°C/min |
| Temperature Tracking Rate | 0.02–13°C/min |
| Wall-to-Sample Temperature Difference (Isothermal Mode) | <0.5°C |
| Max Sample Length | 600 mm |
| Compliance | GB/T 36276-2023, GB 38031-2020, SN/T 3078.1-2012, SAE J2464-2009, SAND2005-3123, UL 9540A-2019, SAND99-0497-1999 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BAC-90A |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | RT to 500 °C |
| Temperature Resolution | 0.001 °C |
| Chamber Dimensions | Ø90 mm × 110 mm depth |
| Temperature Tracking Rate | 0.005–40 °C/min |
| Minimum Detectable Temperature Rise Rate | 0.005–0.02 °C/min |
| Power Supply | 220 V / 50 Hz |
| Max Power Consumption | ≤3000 W |
| Data Interface | USB or RJ45 |
| Operating Environment | 5–40 °C, <85% RH |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RSC-400A |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic / Quasi-adiabatic Heat Flow & Pressure Monitoring |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.5–10 °C/min |
| Temperature Resolution | 0.01 °C |
| Pressure Range | 0–20 MPa |
| Pressure Resolution | 1 kPa |
| Detection Sensitivity | 1% DTBP in 6 mL Toluene |
| Sample Cell Volume | 8 mL |
| Sample Cell Materials | Stainless Steel (standard), Titanium or Hastelloy C-276 (optional) |
| Interface | RJ45 Ethernet |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 800 W |
| Dimensions | 310 mm × 280 mm × 350 mm |
| Weight | 15.5 kg |
| Operating Environment | 5–40 °C, <85% RH |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Product Type | Reaction Calorimeter |
| Measurement Modes | Heat-Flow, Power-Compensation (optional), Reflux (optional) |
| Temperature Control | Reactor –25 °C to 200 °C |
| Control Modes | Isothermal, Isoperibolic, Temperature Scan |
| Temperature Resolution | 1.0 mK |
| Temperature Stability | ±0.1 K |
| Oil Circulation Rate | 35–76 L/min |
| Heater Driver | 0–50 VDC, max 3.0 A, 120 W |
| Reactor Options | 1000 mL Glass (atmospheric/0.6 MPa/1.2 MPa), or 1000 mL Metal (10 MPa) |
| Materials | Borosilicate Glass, 316L SS, Hastelloy® |
| Agitator | up to 2000 rpm (optional 3000 rpm), torque up to 75 N·cm (optional 300 N·cm) |
| Impeller types | Anchor or Paddle |
| Materials | PTFE, 316L SS, Hastelloy® |
| Feeding System | 1 liquid + 1 solid + 1 gas inlet (expandable to 4) |
| Precision Balance | 3100 g / 0.01 g |
| Pumps | Medium-pressure solenoid diaphragm pump (2 L/h), high-pressure precision piston pump (2.4 L/h) |
| Power Supply | 3×400 V / 50 Hz (±10%) / 20 A |
| Total Power | 7000 VA |
| Footprint (Test Area) | 1200 × 600 × 1850 mm |
| Oil Bath Dimensions | 600 × 700 × 1300 mm |
| Oil Bath Mass | 210 kg |
| Unit Mass | 300 kg |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | BAC-800B |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Adiabatic Chamber Internal Dimensions | Ø800 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall–Sample Temperature Difference | ≤1 °C |
| Temperature Control Range | RT to 300 °C (with optional low-temp module: –40 °C to 300 °C |
| Pressure Range | 0–2 MPa |
| Temperature Tracking Rate | 0.02–15 °C/min |
| Nail Penetration Max Stroke | Software-Configurable |
| Current Handling Capacity (Charge/Discharge Electrodes) | ±1000 A |
| Compliance Standards | GB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermal Flow DSC |
| Temperature Range | RT to 700 °C |
| Heating Rate | 0.05–200 °C/min |
| Baseline Stability | ≤100 µW (100–300 °C, uncorrected) |
| Baseline Repeatability | ≤40 µW |
| Heat Flow Noise | <8 µW (peak-to-peak) |
| Enthalpy Accuracy | ±0.8% (In) |
| Enthalpy Precision | ±0.08% (In) |
| Phase Transition Temperature Accuracy | ±0.1 °C (In) |
| Phase Transition Temperature Precision | ±0.02 °C (In) |
| Indium Peak Height / FWHM | ≥20.0 mW/K |
| Sampling Frequency | 50 Hz |
| Heat Flow Range | ±750 mW |
| Gas Control | 3-channel, inert/oxidizing, static/dynamic, 0–300 mL/min |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-800R |
| Compliance | GB/T 36276-2023, GB 38031-2020, SAE J2464-2009, UL 9540A-2019, SN/T 3078.1-2012, SAND 2005-3123, SAND 99-0497-1999 |
| Adiabatic Chamber Dimensions | 800 × 520 mm (L × W) |
| Temperature Control Range | RT+5°C to 300°C (optional low-temp module: –25°C) |
| Temperature Resolution | 0.001°C |
| Chamber Temperature Stability | ±0.05°C |
| Self-Heating Detection Sensitivity | 0.02–0.05°C/min |
| Temperature Tracking Rate | 0.02–15°C/min |
| Wall-to-Sample Temperature Difference (Isothermal Mode) | <1°C |
| Maximum Sample Length | ≤600 mm |
| Safety Features | Pressure Relief Valve + Mechanical Interlock on Lid |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | BIC-400A |
| Pricing | Upon Request |
| Automation | Fully Automated |
| Instrument Type | Isothermal Calorimeter |
| Measurement Principle | Power Compensation Isothermal Calorimetry |
| Temperature Range | −40 °C to 100 °C |
| Temperature Resolution | 0.001 °C |
| Thermal Enthalpy Measurement Accuracy | ±1% (Power Compensation Mode) |
| Baseline Noise | 10 mW (Power Compensation), 0.2 mW (Heat Flow Mode) |
| Maximum Sample Dimensions | 345 mm × 230 mm × 100 mm |
| Max Compensation Power | 200 W |
| Sensitivity | 10 mW (Power Compensation), 0.2 mW (Heat Flow) |
| Temperature Stability | ±0.005 °C (Oil Bath Operation) |
| Oil Bath Temp Range | −40 °C to 200 °C |
| Heating Power | 3 kW |
| Cooling Capacity | 1.5 kW @ 20 °C, 1.5 kW @ 0 °C, 1 kW @ −20 °C, 0.3 kW @ −40 °C |
| Circulation Flow Rate | 22–26 L/min |
| Dual-Stage Pump Pressure | 0.4–0.7 bar (Heating/Cooling Loop), 0.2–0.4 bar (Suction) |
| Bath Opening/Volume | 12 × 11 / 16 cm, 5 L |
| Communication Interface | RS-232 (RJ45 adapter available) |
| Optional Battery Cycler | 4-channel, ±400 A / 0–5 V, ±0.1% FS voltage & current accuracy, SOC estimation support |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | TAC CP-500A |
| Functionality | Automated |
| Instrument Type | Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Range | Ambient to 500 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Detection Threshold | 0.005–0.02 °C/min |
| Temperature Tracking Rate | 0.005–60 °C/min |
| Pressure Range | 0–20 MPa |
| Pressure Resolution | 1 kPa |
| Sample Cell Volume | 8 mL |
| Sample Cell Materials | Stainless Steel, Titanium, or Hastelloy (optional) |
| Phi Factor | ≈1.0 |
| Interface | USB, RS232 |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 3000 W |
| Dimensions | 620 × 470 × 670 mm |
| Weight | 78 kg |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic |
| Model | BAC-420B |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Detection Threshold | < 0.02 °C/min |
| Temperature Tracking Rate | 0.02–13 °C/min |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HFM 510A |
| Measurement Principle | Heat Flow Method |
| Thermal Conductivity Range | 0.002–1 W/(m·K), extendable to 1–2 W/(m·K) |
| Plate Temperature Range | −30–90 °C |
| Thickness Measurement Range | 0–100 mm |
| Thickness Resolution | 0.02 mm |
| Contact Pressure | Adjustable up to 21 kPa (1930 N) |
| Thermal Resistance Range | 0.1–8 m²·K/W |
| Accuracy | ±(1–2)% |
| Repeatability | ≤0.5% |
| Sample Dimensions | 300 mm × 300 mm × ≤100 mm |
| Environmental Operating Range | −5–45 °C, <95% RH |
| Cooling System | External Oil Bath with Peltier Heating/Cooling Control |
| Data Acquisition Points | >10 per test cycle |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | RC HP-1000D |
| Pricing | Upon Request |
| Calorimetry Methods | Heat-Flow, Power-Compensation (optional), Reflux (optional) |
| Reactor Temperature Range | −25 °C to 200 °C |
| Oil-Bath Temperature Range | −45 °C to 250 °C |
| Temperature Resolution | 1.0 mK |
| Temperature Control Precision | ±0.1 K |
| Oil Circulation Rate | 35–76 L/min |
| Heating Power | Up to 120 W |
| Max Stirring Speed | 2000 rpm (optional 3000 rpm) |
| Max Torque | 75 N·cm (optional 300 N·cm) |
| Reactor Volumes | 1000 mL standard (customizable) |
| Pressure Ratings | Ambient / 0.6–1.2 MPa (glass, medium-pressure) / 10 MPa (metal, high-pressure) |
| Reactor Materials | Borosilicate glass, 316L stainless steel, Hastelloy® |
| Stirrer Materials | PTFE, 316L, Hastelloy® |
| Feed Channels | 1 liquid + 1 solid + 1 gas (expandable to 4) |
| Balance Capacity | 3100 g, readability 0.01 g |
| Pump Types | Electromagnetic diaphragm (≤2 L/h), precision plunger (≤2.4 L/h) |
| Electrical Supply | 3×400 V / 50 Hz (±10%) / 20 A |
| Total Power Consumption | 7000 VA |
| Footprint (Test Area) | 1200 × 600 × 1850 mm |
| Oil Bath Dimensions | 600 × 700 × 1300 mm |
| Oil Bath Mass | 210 kg |
| System Mass | 350 kg |