- All
- Favorite
- Popular
- Most rated
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HWP21-30S |
| Temperature Control Range | −10 °C to 210 °C |
| Temperature Accuracy | ±1 °C |
| Sample Temperature Measurement Range | −50 °C to 350 °C |
| Sample Temperature Resolution | 0.1 °C |
| Sample Temperature Accuracy | ≤ ±(0.15 + 0.002 |
| Gas Mixing Pressure Range | 0–110 kPa |
| Pressure Accuracy | ±0.1% FS |
| Vacuum Capability | ≤1.33 kPa |
| Leak Rate | ≤0.03 kPa/min |
| Ignition Spark Gap | 6.4 mm |
| Ignition Voltage/Current | 15 kV / 30 mA |
| Ignition Duration | 0–1 s |
| Test Vessel Options | 5 L (Ø222 mm × H345 mm) or 12 L (Ø295 mm × H378 mm) borosilicate glass |
| Stirring Speed | ≥300 rpm |
| Environmental Monitoring | Ambient Temp (−10–60 °C, ±0.5 °C), RH (5–95% RH, ±5.0% RH), Atmospheric Pressure (60–110 kPa, ±0.5 kPa) |
| Timing Range | 0–24 h |
| Timing Accuracy | ±0.01 s |
| IP Rating | IP65 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP14-10S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Temperature Measurement Range | (-40 to 1000) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1.5 °C or ≤ ±0.004 |
| Temperature Sampling Rate | 1000 Hz |
| Deflagration Distance | 50 mm |
| Deflagration Velocity Range | ≤1500 mm/s |
| Velocity Measurement Accuracy | ±0.1 mm/s |
| Time Display Resolution | ±0.1 ms |
| Detection Method | Thermocouple-based temperature monitoring |
| Dewar Vessel Internal Volume | 300 cm³ |
| Dewar Inner Diameter | 48 mm |
| Dewar Outer Diameter | 60 mm |
| Dewar Length | 200 mm |
| Dewar Cooling Half-life | ≥5 h |
| Ignition Flame Length | ≥20 mm |
| Instrument Dimensions (L×W×H) | 830 mm × 400 mm × 600 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP20-10S |
| Pricing | Available Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ECB-2002A |
| Price | Upon Request |
| Test Vessel Temp. Range | Ambient to 200 °C |
| Max. Design Pressure | ≥2.0 MPa |
| Explosion Pressure Sensor Range | ≥5.0 MPa, Linearity: ±1.0% FS |
| Pressure Sampling Rate | ≥5 kHz |
| Data Points per Test | ≥10,000 |
| Gas Inlet Channels | 3 |
| Max. Stirring Speed | 400 rpm (adjustable) |
| Operating Environment | −5–45 °C, <95% RH |
| Gas Pressure Control Accuracy | ±0.1% FS |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HWP13-10S |
| Temperature Control Range | Ambient to 200°C |
| Temperature Accuracy | ±1°C |
| Uniformity | ±1.0°C (≤140°C), ±1.5°C (140–180°C), ±2.0°C (180–200°C) |
| Thermocouple Range | −40 to 1000°C |
| Temp. Resolution | 0.1°C |
| Temp. Measurement Accuracy | ±1.5°C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timing Range | 0–240 h |
| Custom Timing Range | 0–480 h |
| Timing Accuracy | ±0.01 s |
| Timing Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Sample Cage Dimensions | 25 mm and 100 mm cubes |
| Test Tube Dimensions (Φ×H) | (50.5±0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP01-20S |
| Pricing | Upon Request |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Uniformity in Test Zone | ±1.0 °C (≤140 °C), ±1.5 °C (140–180 °C), ±2.0 °C (180–200 °C) |
| Thermocouple Range | −40 to 1000 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Measurement Accuracy | ±1.5 °C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timer Range | 0–240 h |
| Custom Timer Range | 0–480 h |
| Timer Accuracy | ±0.01 s |
| Timer Display Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Self-Heating Test Mesh Cage Sizes | 25 mm × 25 mm × 25 mm and 100 mm × 100 mm × 100 mm |
| 75 °C Stability Vessel Dimensions | Φ(50.5 ± 0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP18-30S |
| Quotation | Upon Request |
| Operating Environment | (-5–45) °C, <95% RH |
| Impact Masses | 0.5 kg ±0.1%, 1 kg ±0.1%, 2 kg ±0.1%, 5 kg ±0.1%, 10 kg ±0.1% |
| Drop Height Range | 0–1000 mm |
| Positioning Accuracy | ±1 mm |
| Guide Rail Verticality | ≤0.1 mm/m |
| Hammer Coaxiality | ≤φ0.15 mm |
| Instrument Planarity Deviation | ≤0.012 mm |
| Impact Energy Range | 0.5–100 J |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | HWP27-10S |
| Price | Upon Request |
| Operating Environment | (-5–45)°C, <95% RH |
| Chamber Temperature Range | -20°C to 220°C |
| Temperature Control Accuracy | ±1°C |
| Sample Temperature Measurement Range | -50°C to 500°C |
| Sample Temperature Resolution | 0.1°C |
| Sample Temperature Accuracy | ±(2.5 or 0.0075× |
| Dewar Volume | 1 L |
| Constant Power Regulation Range | 0.1 W–2 W |
| Constant Power Accuracy | ≤0.015 W |
| Temperature Rise Rate Range | 0–2°C/min |
| Refrigerant Circulation Flow Rate | ≥3 L/min |
| Dewar Liner Material | Borosilicate Glass |
| Dimensions (L×W×H) | 930 mm × 545 mm × 875 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP17-10S |
| Operating Temperature | (-5–45) °C |
| Relative Humidity | <95% RH |
| Motor Speed | 140 ± 3 rpm (at maximum load) |
| Load Range | 1–2–5–10–20–40–60–80–120–160–240–360 N |
| Load Accuracy | ±0.038 N (1 N), ±0.048 N (2 N), ±0.08 N (5 N), ±0.21 N (10 N), ±0.45 N (20 N), ±0.49 N (40 N), ±0.22 N (60 N), ±0.27 N (80 N), ±0.32 N (120 N), ±0.37 N (160 N), ±0.43 N (240 N), ±0.48 N (360 N) |
| Sieve Mesh | 35 mesh (optional) |
| Alumina Ceramic Surface Roughness | 9–32 µm |
| Center-to-Center Distance (Weight–Ceramic Rod) | 11, 16, 21, 26, 31, 36 cm |
| Ceramic Plate Stroke | 10 mm |
| Ceramic Plate Dimensions (L×W×H) | 25 × 25 × 5 mm |
| Ceramic Rod Dimensions (Φ×L) | 10 × 15 mm |
Show next