BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelHWP21-30S
Temperature Control Range−10 °C to 210 °C
Temperature Accuracy±1 °C
Sample Temperature Measurement Range−50 °C to 350 °C
Sample Temperature Resolution0.1 °C
Sample Temperature Accuracy≤ ±(0.15 + 0.002
Gas Mixing Pressure Range0–110 kPa
Pressure Accuracy±0.1% FS
Vacuum Capability≤1.33 kPa
Leak Rate≤0.03 kPa/min
Ignition Spark Gap6.4 mm
Ignition Voltage/Current15 kV / 30 mA
Ignition Duration0–1 s
Test Vessel Options5 L (Ø222 mm × H345 mm) or 12 L (Ø295 mm × H378 mm) borosilicate glass
Stirring Speed≥300 rpm
Environmental MonitoringAmbient Temp (−10–60 °C, ±0.5 °C), RH (5–95% RH, ±5.0% RH), Atmospheric Pressure (60–110 kPa, ±0.5 kPa)
Timing Range0–24 h
Timing Accuracy±0.01 s
IP RatingIP65
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelHWP14-10S
QuotationUpon Request
Operating Environment(-5 to 45) °C, <95% RH
Temperature Measurement Range(-40 to 1000) °C
Temperature Resolution0.1 °C
Temperature Accuracy±1.5 °C or ≤ ±0.004
Temperature Sampling Rate1000 Hz
Deflagration Distance50 mm
Deflagration Velocity Range≤1500 mm/s
Velocity Measurement Accuracy±0.1 mm/s
Time Display Resolution±0.1 ms
Detection MethodThermocouple-based temperature monitoring
Dewar Vessel Internal Volume300 cm³
Dewar Inner Diameter48 mm
Dewar Outer Diameter60 mm
Dewar Length200 mm
Dewar Cooling Half-life≥5 h
Ignition Flame Length≥20 mm
Instrument Dimensions (L×W×H)830 mm × 400 mm × 600 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelHWP02-20S
QuotationUpon Request
Operating Environment(-5 to 45) °C, <95% RH
Ignition Source Temperature≥1000 °C
Ignition MethodsGas igniter and silicon nitride rod
Combustion Detection MethodNear-infrared (NIR) spectroscopy
Combustion Travel Range0–250 mm
Burning Distance Measurement Accuracy±0.5 mm
Maximum Combustion Velocity Detection250 mm/s
Timing Range5 min (non-metallic samples)
Time Display Resolution0.1 s
Stacking Mold Dimensions260 mm (L) × 20 mm (W), triangular cross-section with internal height of 10 mm
Combustion Plate MaterialAlumina-mullite ceramic — non-porous, non-combustible, low thermal conductivity
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHWP20-10S
PricingAvailable Upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelBAC-420A
Measurement ModeAdiabatic Calorimetry
Instrument TypeAccelerating Rate Calorimeter
Adiabatic Chamber DimensionsØ420 mm × 520 mm depth
Self-Heating Detection Sensitivity<0.02 °C/min
Wall-Sample Temperature Difference Control≤0.5 °C
Temperature Control RangeRT to 300 °C
Temperature Tracking Rate0.02–13 °C/min
Sealed Test Vessel Pressure Range0–2 MPa
Nail Penetration StrokeSoftware-Configurable
Current Handling Capacity (Charge/Discharge Electrodes)±500 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelHWP34-10S
PriceUpon Request
Operating Environment(-5–45)°C, <95% RH
Heating Rate(3.5 ± 0.3) K/s
Vessel Internal DimensionsΦ50 mm × 94.5 mm
Vessel Material316 Stainless Steel
Burst Disc MaterialAluminum Plate, Ø38 mm
Burst Pressure620 ± 60 kPa @ 22°C
Orifice Plate Diameters1.0, 2.0, 3.5, 6.0, 9.0, 12.0, 16.0, 24.0 mm
Orifice Plate Thickness2.0 ± 0.2 mm
Temperature Resolution±0.1°C
Temperature Sensor Response Time0.5 s
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Origin CategoryDomestic
ModelHWP01-10S
PriceUpon Request
Operating Environment5–30 °C, <85% RH
Temperature Control RangeAmbient to 200 °C
Temperature Control Accuracy±1 °C
Uniformity in Test Zone±1.5 °C (≤140 °C), ±2 °C (140–180 °C), ±2.5 °C (180–200 °C)
Temperature Measurement Range0–500 °C
Temperature Resolution0.1 °C
Temperature Accuracy±2.5 °C (<300 °C), ±0.75% of reading (≥300 °C)
Standard Timer Range0–24 h
Custom Timer Range0–48 h
Timer Resolution1 s
Wire Mesh ContainersSmall cube: 25 mm side, 0.05 mm aperture
Small cover30 × 30 × 30 mm
Large cube100 mm side, 0.05 mm aperture
Large cover105 × 105 × 105 mm
Cage dimensions150 × 150 × 250 mm
Chamber Interior Dimensions350 × 350 × 400 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelBAC-1000A
Measurement ModeAdiabatic Calorimetry
Instrument TypeAccelerating Rate Calorimeter (ARC)
Temperature RangeRT to 300 °C (–25 °C with optional low-temp module)
Adiabatic Chamber DimensionsØ420 mm × 520 mm depth
Self-Heating Detection Sensitivity<0.02 °C/min
Wall-Sample Temperature Difference Control0.02–15 °C/min
Sealed Test Vessel Pressure Range0–2 MPa
Needle Penetration StrokeProgrammable
Current Capacity (Charge/Discharge Electrodes)±1000 A
Compliance StandardsGB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHWP12-10S
PricingAvailable Upon Request
Operating Temperature(-5 to 45) °C
Relative Humidity<95% RH
Compressed Air Flow Range5–500 sccm
Flow Control Accuracy±1% FS
Flow Response Time≤1 s
Ignition MethodElectric Spark
Combustion DetectionInfrared Photodetection
Combustion Detection Response Time≤1 ms
Flame Propagation Velocity Range≤500 cm/s
Flame Propagation Velocity Accuracy±5 mm/s
Safety Valve Activation Pressure2 kg/cm²
Reaction Tube Dimensions300 mm (L) × 50 mm (ID) × 5 mm (wall thickness)
Maximum Inlet Gas Pressure≤5 MPa
Sample Bag Capacity1 L
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Instrument TypeAccelerating Rate Calorimeter (ARC)
Measurement ModeAdiabatic Calorimetry
ModelBAC-800A
ComplianceGB/T 36276–2023, UL 9540A, SAE J2464-R2009, ASTM E1981–98(2012), UL 1973, SN/T 3078.1–2012, SAND99-0497, FreedomCAR SAND 2005-3123
Adiabatic Chamber DimensionsØ800 mm × 520 mm depth
Self-Heating Detection Sensitivity<0.02 °C/min
Wall–Sample Temperature Differential≤1 °C
Temperature Control RangeRT to 300 °C (with optional low-temperature module down to –25 °C)
Temperature Tracking Rate0.02–15 °C/min
Sealed Test Vessel Pressure Range0–2 MPa
Puncture StrokeSoftware-Configurable
Current Capacity of Charging/Discharging Electrode Posts±500 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelSEG-100A
Operating Ambient−5°C to 45°C, <95% RH
Test Chamber Temperature Range10°C–35°C (default setpoint: 20°C, software-adjustable)
Temperature Stability±0.5°C
Water Addition Volume400 mL (automated sample immersion)
Sample Cup Capacity20 mL
Gas Volume Measurement Accuracy±0.5 mL
Maximum Gas Collection Capacity0–800 mL
Gas Volume Resolution0.01 mL
Gas Evolution Rate Range0–100 L/min/kg
Gas Sampling Interval1 s
Rate Calculation Interval1 min–1 h (software-configurable)
Total Timing Range0–240 h
Water Injection Volume300 mL
Water Injection Accuracy≤±1 mL
Pressure Measurement Range−5 kPa to +5 kPa
Pressure Measurement Accuracy±0.1% FS
Optional Mass Measurement Range0–3100 g
Mass Measurement Accuracy±0.01 g
Water Bath Temperature Control20°C ±0.5°C (adjustable)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Instrument TypeThermal Flow DSC
Sample CapacitySingle-sample
Temperature Range–90 °C to 550 °C (with optional imported high-performance mechanical cryocooler)
Cooling MethodMechanical refrigeration + air cooling
Heating/Cooling Rate0.05–200 °C/min (heating), 0.1–100 °C/min (cooling)
Temperature Accuracy±0.1 °C (In), Precision: ±0.02 °C (In)
Baseline Drift≤100 µW (–50–300 °C, no baseline correction)
Baseline Repeatability≤40 µW
Peak Noise (Heat Flow)<8 µW
Enthalpy Accuracy±0.8% (In), Precision: ±0.08% (In)
Indium Peak Height/FWHM≥20.0 mW/K
Data Acquisition Rate50 Hz
Heat Flow Range±750 mW
Gas Control3-channel mass-flow-controlled atmosphere (inert/oxidizing, static/dynamic, 0–300 mL/min)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelECD-20A
Operating PrinciplePneumatic Dust Dispersion + Controlled Ignition (Chemical or Electrostatic)
Explosion Protection RatingEx d IIB T4 Gb
Relative Uncertainty±8.8% (per ISO/IEC 17025-compliant validation protocol)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelECB-2002A
PriceUpon Request
Test Vessel Temp. RangeAmbient to 200 °C
Max. Design Pressure≥2.0 MPa
Explosion Pressure Sensor Range≥5.0 MPa, Linearity: ±1.0% FS
Pressure Sampling Rate≥5 kHz
Data Points per Test≥10,000
Gas Inlet Channels3
Max. Stirring Speed400 rpm (adjustable)
Operating Environment−5–45 °C, <95% RH
Gas Pressure Control Accuracy±0.1% FS
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelATC 300A
Instrument TypeBomb Calorimeter
Ignition MethodCotton Thread & Ignition Wire
Temperature Resolution0.0001 °C
Test ModeIsothermal
Test Duration≤15 min (Standard Method), ≤10 min (Rapid Method)
Calorific Value Range≤34,000 J
Heat Capacity Precision≤0.10%
Heat Capacity Drift≤0.20%
Oxygen Bomb Max Pressure240 bar
Bomb MaterialStainless Steel & Hastelloy (Corrosion-Resistant)
Data Storage Capacity≥10,000 Tests
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
ManufacturerYes
Country of OriginDomestic (China)
ModelHWP09-10S
QuotationUpon Request
Operating Environment(-5–45) °C, <95% RH
Detection MethodNear-Infrared (NIR)
Spectral Response Range760–1100 nm
Spectral Response Frequency5000 Hz
Ambient Temperature Range(-10–+60) °C
Ambient Temperature Accuracy±0.5 °C
Ambient Humidity Range(5–95)% RH
Ambient Humidity Accuracy±5.0% RH
Combustion Detection Response Time≤6 ms
Ignition Distance Measurement Range15–90 cm
Burner Positioning Accuracy±1 mm
Timing Resolution±0.01 s
Minimum Actuation Duration5 s
Ignition SourceGas-fired igniter
Aerosol Can OrientationMotorized vertical/inverted repositioning
Compatible Can DimensionsHeight 120–400 mm, Diameter 30–80 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelHWP13-10S
Temperature Control RangeAmbient to 200°C
Temperature Accuracy±1°C
Uniformity±1.0°C (≤140°C), ±1.5°C (140–180°C), ±2.0°C (180–200°C)
Thermocouple Range−40 to 1000°C
Temp. Resolution0.1°C
Temp. Measurement Accuracy±1.5°C or ≤±0.004
Response Time0.5 s
Standard Timing Range0–240 h
Custom Timing Range0–480 h
Timing Accuracy±0.01 s
Timing Resolution1 s
Chamber Volume≥27 L
Sample Cage Dimensions25 mm and 100 mm cubes
Test Tube Dimensions (Φ×H)(50.5±0.5) mm × 150 mm
Interior Chamber Dimensions350 mm × 350 mm × 400 mm
Safety Valve Activation Pressure60 kPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelTAC-500A
Instrument TypeAccelerating Calorimeter
Measurement ModeAdiabatic Calorimetry
Temperature Control RangeAmbient to 500 °C
Temperature Detection Threshold0.005–0.02 °C/min
Temperature Tracking Rate0.005–40 °C/min
Temperature Display Resolution0.001 °C
Maximum Pressure Rating20 MPa
Pressure Resolution1 kPa
Sample Cell Volume8 mL
Sample Cell MaterialsStainless Steel (standard), Titanium or Hastelloy (optional)
Phi Factor≤1.35
InterfaceUSB or RJ45
Power SupplyAC 220 V / 50 Hz
Power Consumption≤3000 W
Dimensions620 × 470 × 670 mm
Weight~78 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelMIE-3000A
Safety RatingExplosion-Proof
Resolution0.03%
Relative Error±2%
Spark Energy Range1–3000 mJ (8 discrete steps)
Charging Voltage0–15 kV
Discharge Load OptionsOpen-circuit or 1 mH inductive load
Test VesselHartmann tube (1.2 L)
Electrode MaterialStainless steel (2 mm diameter)
Electrode SpacingAdjustable from 2 mm to 10 mm
Electrode TriggeringHigh-voltage relay + movable electrode actuation
Ignition Delay Time20–200 ms (adjustable)
Powder Dispersion Pressure0.4–0.7 MPa (adjustable)
Operating Environment5–45 °C, <85% RH
Power Supply90–260 VAC, 47–63 Hz
Rated Power300 W
InterfaceDual USB 2.0 ports
Display7-inch color TFT touchscreen
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelVP TE-1000A
PricingUpon Request
Analytical MethodThree-Stage Expansion Method
Pressure Range0–1000 kPa
Temperature Range0–120 °C
Temperature Stability±0.1 °C
Pressure Resolution0.01 kPa
Repeatability≤0.3 kPa (@37.8 °C, 70 kPa)
Reproducibility≤0.7 kPa (@37.8 °C, 70 kPa)
Sample Volume1 mL (10 mL including wash cycle)
Vapor–Liquid Ratio0.02:1 to 4:1
Dimensions225 × 290 × 390 mm
Weight12 kg
Power SupplyAC 220 V / 50 Hz
Power Consumption150 W
Environmental Operating Conditions5–40 °C, <85% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeDirect Manufacturer
ModelBAC-420R
Measurement ModeAdiabatic Calorimetry
Adiabatic Chamber Dimensions420 × 520 mm (L × W)
Temperature Control RangeRT+5°C to 300°C (optional low-temp module down to −25°C)
Temperature Resolution0.001°C
Chamber Temperature Stability±0.05°C
Self-Heating Detection Sensitivity0.02–0.05°C/min
Temperature Tracking Rate0.02–13°C/min
Wall-to-Sample Temperature Difference (Isothermal Mode)<0.5°C
Max Sample Length600 mm
ComplianceGB/T 36276-2023, GB 38031-2020, SN/T 3078.1-2012, SAE J2464-2009, SAND2005-3123, UL 9540A-2019, SAND99-0497-1999
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
ModelHWP28-10S
Working Environment(-5–45)°C, <95% RH
Test Vessel MaterialASTM A240 S31603 Stainless Steel (316L)
Pressure Vessel Rating≥5 MPa
Test Vessel Volume≥5 L
Ultimate Vacuum≤0.1 kPa
Leak Rate≤0.01 kPa/min
Gas Mixing Pressure Sensor Range0–200 kPa
Gas Mixing Pressure Sensor Accuracy≤±0.1% FS
Ignition Rod Diameter≥3 mm
Ni-Cr Wire Diameter0.05–0.2 mm
Ignition Energy10–20 J
Explosion Pressure Sensor Range0–5000 kPa
Explosion Pressure Sensor Overpressure Rating≥10 MPa
Explosion Pressure Sensor Accuracy±0.1% FS
Explosion Pressure Sensor Response Time≤0.5 ms
Explosion Temperature Measurement Range-50–350°C
Explosion Temperature Accuracy≤±(0.15 + 0.002
System Sampling Frequency≥2 kHz
Timing Range0–24 h, Resolution: ±0.01 s
Magnetic Stirring Speed≥300 rpm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYoung Instruments
OriginZhejiang, China
Manufacturer TypeManufacturer
Product OriginDomestic (China)
ModelFP CC-420A
Detection MethodClosed-Cup Method
Temperature Range−30 °C to 420 °C
Ignition MethodHigh-Voltage Electric Arc