| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HWP21-30S |
| Temperature Control Range | −10 °C to 210 °C |
| Temperature Accuracy | ±1 °C |
| Sample Temperature Measurement Range | −50 °C to 350 °C |
| Sample Temperature Resolution | 0.1 °C |
| Sample Temperature Accuracy | ≤ ±(0.15 + 0.002 |
| Gas Mixing Pressure Range | 0–110 kPa |
| Pressure Accuracy | ±0.1% FS |
| Vacuum Capability | ≤1.33 kPa |
| Leak Rate | ≤0.03 kPa/min |
| Ignition Spark Gap | 6.4 mm |
| Ignition Voltage/Current | 15 kV / 30 mA |
| Ignition Duration | 0–1 s |
| Test Vessel Options | 5 L (Ø222 mm × H345 mm) or 12 L (Ø295 mm × H378 mm) borosilicate glass |
| Stirring Speed | ≥300 rpm |
| Environmental Monitoring | Ambient Temp (−10–60 °C, ±0.5 °C), RH (5–95% RH, ±5.0% RH), Atmospheric Pressure (60–110 kPa, ±0.5 kPa) |
| Timing Range | 0–24 h |
| Timing Accuracy | ±0.01 s |
| IP Rating | IP65 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP14-10S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Temperature Measurement Range | (-40 to 1000) °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±1.5 °C or ≤ ±0.004 |
| Temperature Sampling Rate | 1000 Hz |
| Deflagration Distance | 50 mm |
| Deflagration Velocity Range | ≤1500 mm/s |
| Velocity Measurement Accuracy | ±0.1 mm/s |
| Time Display Resolution | ±0.1 ms |
| Detection Method | Thermocouple-based temperature monitoring |
| Dewar Vessel Internal Volume | 300 cm³ |
| Dewar Inner Diameter | 48 mm |
| Dewar Outer Diameter | 60 mm |
| Dewar Length | 200 mm |
| Dewar Cooling Half-life | ≥5 h |
| Ignition Flame Length | ≥20 mm |
| Instrument Dimensions (L×W×H) | 830 mm × 400 mm × 600 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HWP02-20S |
| Quotation | Upon Request |
| Operating Environment | (-5 to 45) °C, <95% RH |
| Ignition Source Temperature | ≥1000 °C |
| Ignition Methods | Gas igniter and silicon nitride rod |
| Combustion Detection Method | Near-infrared (NIR) spectroscopy |
| Combustion Travel Range | 0–250 mm |
| Burning Distance Measurement Accuracy | ±0.5 mm |
| Maximum Combustion Velocity Detection | 250 mm/s |
| Timing Range | 5 min (non-metallic samples) |
| Time Display Resolution | 0.1 s |
| Stacking Mold Dimensions | 260 mm (L) × 20 mm (W), triangular cross-section with internal height of 10 mm |
| Combustion Plate Material | Alumina-mullite ceramic — non-porous, non-combustible, low thermal conductivity |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP20-10S |
| Pricing | Available Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | ≤0.5 °C |
| Temperature Control Range | RT to 300 °C |
| Temperature Tracking Rate | 0.02–13 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Nail Penetration Stroke | Software-Configurable |
| Current Handling Capacity (Charge/Discharge Electrodes) | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HWP34-10S |
| Price | Upon Request |
| Operating Environment | (-5–45)°C, <95% RH |
| Heating Rate | (3.5 ± 0.3) K/s |
| Vessel Internal Dimensions | Φ50 mm × 94.5 mm |
| Vessel Material | 316 Stainless Steel |
| Burst Disc Material | Aluminum Plate, Ø38 mm |
| Burst Pressure | 620 ± 60 kPa @ 22°C |
| Orifice Plate Diameters | 1.0, 2.0, 3.5, 6.0, 9.0, 12.0, 16.0, 24.0 mm |
| Orifice Plate Thickness | 2.0 ± 0.2 mm |
| Temperature Resolution | ±0.1°C |
| Temperature Sensor Response Time | 0.5 s |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | HWP01-10S |
| Price | Upon Request |
| Operating Environment | 5–30 °C, <85% RH |
| Temperature Control Range | Ambient to 200 °C |
| Temperature Control Accuracy | ±1 °C |
| Uniformity in Test Zone | ±1.5 °C (≤140 °C), ±2 °C (140–180 °C), ±2.5 °C (180–200 °C) |
| Temperature Measurement Range | 0–500 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±2.5 °C (<300 °C), ±0.75% of reading (≥300 °C) |
| Standard Timer Range | 0–24 h |
| Custom Timer Range | 0–48 h |
| Timer Resolution | 1 s |
| Wire Mesh Containers | Small cube: 25 mm side, 0.05 mm aperture |
| Small cover | 30 × 30 × 30 mm |
| Large cube | 100 mm side, 0.05 mm aperture |
| Large cover | 105 × 105 × 105 mm |
| Cage dimensions | 150 × 150 × 250 mm |
| Chamber Interior Dimensions | 350 × 350 × 400 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | BAC-1000A |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Temperature Range | RT to 300 °C (–25 °C with optional low-temp module) |
| Adiabatic Chamber Dimensions | Ø420 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall-Sample Temperature Difference Control | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Needle Penetration Stroke | Programmable |
| Current Capacity (Charge/Discharge Electrodes) | ±1000 A |
| Compliance Standards | GB/T 36276–2023, UL 9540A, SAE J2464–2009, ASTM E1981–98(2012), SN/T 3078.1–2012, UL 1973, SAND99-0497, FreedomCAR SAND2005-3123 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP12-10S |
| Pricing | Available Upon Request |
| Operating Temperature | (-5 to 45) °C |
| Relative Humidity | <95% RH |
| Compressed Air Flow Range | 5–500 sccm |
| Flow Control Accuracy | ±1% FS |
| Flow Response Time | ≤1 s |
| Ignition Method | Electric Spark |
| Combustion Detection | Infrared Photodetection |
| Combustion Detection Response Time | ≤1 ms |
| Flame Propagation Velocity Range | ≤500 cm/s |
| Flame Propagation Velocity Accuracy | ±5 mm/s |
| Safety Valve Activation Pressure | 2 kg/cm² |
| Reaction Tube Dimensions | 300 mm (L) × 50 mm (ID) × 5 mm (wall thickness) |
| Maximum Inlet Gas Pressure | ≤5 MPa |
| Sample Bag Capacity | 1 L |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Accelerating Rate Calorimeter (ARC) |
| Measurement Mode | Adiabatic Calorimetry |
| Model | BAC-800A |
| Compliance | GB/T 36276–2023, UL 9540A, SAE J2464-R2009, ASTM E1981–98(2012), UL 1973, SN/T 3078.1–2012, SAND99-0497, FreedomCAR SAND 2005-3123 |
| Adiabatic Chamber Dimensions | Ø800 mm × 520 mm depth |
| Self-Heating Detection Sensitivity | <0.02 °C/min |
| Wall–Sample Temperature Differential | ≤1 °C |
| Temperature Control Range | RT to 300 °C (with optional low-temperature module down to –25 °C) |
| Temperature Tracking Rate | 0.02–15 °C/min |
| Sealed Test Vessel Pressure Range | 0–2 MPa |
| Puncture Stroke | Software-Configurable |
| Current Capacity of Charging/Discharging Electrode Posts | ±500 A |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SEG-100A |
| Operating Ambient | −5°C to 45°C, <95% RH |
| Test Chamber Temperature Range | 10°C–35°C (default setpoint: 20°C, software-adjustable) |
| Temperature Stability | ±0.5°C |
| Water Addition Volume | 400 mL (automated sample immersion) |
| Sample Cup Capacity | 20 mL |
| Gas Volume Measurement Accuracy | ±0.5 mL |
| Maximum Gas Collection Capacity | 0–800 mL |
| Gas Volume Resolution | 0.01 mL |
| Gas Evolution Rate Range | 0–100 L/min/kg |
| Gas Sampling Interval | 1 s |
| Rate Calculation Interval | 1 min–1 h (software-configurable) |
| Total Timing Range | 0–240 h |
| Water Injection Volume | 300 mL |
| Water Injection Accuracy | ≤±1 mL |
| Pressure Measurement Range | −5 kPa to +5 kPa |
| Pressure Measurement Accuracy | ±0.1% FS |
| Optional Mass Measurement Range | 0–3100 g |
| Mass Measurement Accuracy | ±0.01 g |
| Water Bath Temperature Control | 20°C ±0.5°C (adjustable) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Thermal Flow DSC |
| Sample Capacity | Single-sample |
| Temperature Range | –90 °C to 550 °C (with optional imported high-performance mechanical cryocooler) |
| Cooling Method | Mechanical refrigeration + air cooling |
| Heating/Cooling Rate | 0.05–200 °C/min (heating), 0.1–100 °C/min (cooling) |
| Temperature Accuracy | ±0.1 °C (In), Precision: ±0.02 °C (In) |
| Baseline Drift | ≤100 µW (–50–300 °C, no baseline correction) |
| Baseline Repeatability | ≤40 µW |
| Peak Noise (Heat Flow) | <8 µW |
| Enthalpy Accuracy | ±0.8% (In), Precision: ±0.08% (In) |
| Indium Peak Height/FWHM | ≥20.0 mW/K |
| Data Acquisition Rate | 50 Hz |
| Heat Flow Range | ±750 mW |
| Gas Control | 3-channel mass-flow-controlled atmosphere (inert/oxidizing, static/dynamic, 0–300 mL/min) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ECD-20A |
| Operating Principle | Pneumatic Dust Dispersion + Controlled Ignition (Chemical or Electrostatic) |
| Explosion Protection Rating | Ex d IIB T4 Gb |
| Relative Uncertainty | ±8.8% (per ISO/IEC 17025-compliant validation protocol) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | ECB-2002A |
| Price | Upon Request |
| Test Vessel Temp. Range | Ambient to 200 °C |
| Max. Design Pressure | ≥2.0 MPa |
| Explosion Pressure Sensor Range | ≥5.0 MPa, Linearity: ±1.0% FS |
| Pressure Sampling Rate | ≥5 kHz |
| Data Points per Test | ≥10,000 |
| Gas Inlet Channels | 3 |
| Max. Stirring Speed | 400 rpm (adjustable) |
| Operating Environment | −5–45 °C, <95% RH |
| Gas Pressure Control Accuracy | ±0.1% FS |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | FCPP-80A |
| Pricing | Upon Request |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | ATC 300A |
| Instrument Type | Bomb Calorimeter |
| Ignition Method | Cotton Thread & Ignition Wire |
| Temperature Resolution | 0.0001 °C |
| Test Mode | Isothermal |
| Test Duration | ≤15 min (Standard Method), ≤10 min (Rapid Method) |
| Calorific Value Range | ≤34,000 J |
| Heat Capacity Precision | ≤0.10% |
| Heat Capacity Drift | ≤0.20% |
| Oxygen Bomb Max Pressure | 240 bar |
| Bomb Material | Stainless Steel & Hastelloy (Corrosion-Resistant) |
| Data Storage Capacity | ≥10,000 Tests |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer | Yes |
| Country of Origin | Domestic (China) |
| Model | HWP09-10S |
| Quotation | Upon Request |
| Operating Environment | (-5–45) °C, <95% RH |
| Detection Method | Near-Infrared (NIR) |
| Spectral Response Range | 760–1100 nm |
| Spectral Response Frequency | 5000 Hz |
| Ambient Temperature Range | (-10–+60) °C |
| Ambient Temperature Accuracy | ±0.5 °C |
| Ambient Humidity Range | (5–95)% RH |
| Ambient Humidity Accuracy | ±5.0% RH |
| Combustion Detection Response Time | ≤6 ms |
| Ignition Distance Measurement Range | 15–90 cm |
| Burner Positioning Accuracy | ±1 mm |
| Timing Resolution | ±0.01 s |
| Minimum Actuation Duration | 5 s |
| Ignition Source | Gas-fired igniter |
| Aerosol Can Orientation | Motorized vertical/inverted repositioning |
| Compatible Can Dimensions | Height 120–400 mm, Diameter 30–80 mm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | HWP13-10S |
| Temperature Control Range | Ambient to 200°C |
| Temperature Accuracy | ±1°C |
| Uniformity | ±1.0°C (≤140°C), ±1.5°C (140–180°C), ±2.0°C (180–200°C) |
| Thermocouple Range | −40 to 1000°C |
| Temp. Resolution | 0.1°C |
| Temp. Measurement Accuracy | ±1.5°C or ≤±0.004 |
| Response Time | 0.5 s |
| Standard Timing Range | 0–240 h |
| Custom Timing Range | 0–480 h |
| Timing Accuracy | ±0.01 s |
| Timing Resolution | 1 s |
| Chamber Volume | ≥27 L |
| Sample Cage Dimensions | 25 mm and 100 mm cubes |
| Test Tube Dimensions (Φ×H) | (50.5±0.5) mm × 150 mm |
| Interior Chamber Dimensions | 350 mm × 350 mm × 400 mm |
| Safety Valve Activation Pressure | 60 kPa |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | TAC-500A |
| Instrument Type | Accelerating Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Temperature Control Range | Ambient to 500 °C |
| Temperature Detection Threshold | 0.005–0.02 °C/min |
| Temperature Tracking Rate | 0.005–40 °C/min |
| Temperature Display Resolution | 0.001 °C |
| Maximum Pressure Rating | 20 MPa |
| Pressure Resolution | 1 kPa |
| Sample Cell Volume | 8 mL |
| Sample Cell Materials | Stainless Steel (standard), Titanium or Hastelloy (optional) |
| Phi Factor | ≤1.35 |
| Interface | USB or RJ45 |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | ≤3000 W |
| Dimensions | 620 × 470 × 670 mm |
| Weight | ~78 kg |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MIE-3000A |
| Safety Rating | Explosion-Proof |
| Resolution | 0.03% |
| Relative Error | ±2% |
| Spark Energy Range | 1–3000 mJ (8 discrete steps) |
| Charging Voltage | 0–15 kV |
| Discharge Load Options | Open-circuit or 1 mH inductive load |
| Test Vessel | Hartmann tube (1.2 L) |
| Electrode Material | Stainless steel (2 mm diameter) |
| Electrode Spacing | Adjustable from 2 mm to 10 mm |
| Electrode Triggering | High-voltage relay + movable electrode actuation |
| Ignition Delay Time | 20–200 ms (adjustable) |
| Powder Dispersion Pressure | 0.4–0.7 MPa (adjustable) |
| Operating Environment | 5–45 °C, <85% RH |
| Power Supply | 90–260 VAC, 47–63 Hz |
| Rated Power | 300 W |
| Interface | Dual USB 2.0 ports |
| Display | 7-inch color TFT touchscreen |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | VP TE-1000A |
| Pricing | Upon Request |
| Analytical Method | Three-Stage Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 0–120 °C |
| Temperature Stability | ±0.1 °C |
| Pressure Resolution | 0.01 kPa |
| Repeatability | ≤0.3 kPa (@37.8 °C, 70 kPa) |
| Reproducibility | ≤0.7 kPa (@37.8 °C, 70 kPa) |
| Sample Volume | 1 mL (10 mL including wash cycle) |
| Vapor–Liquid Ratio | 0.02:1 to 4:1 |
| Dimensions | 225 × 290 × 390 mm |
| Weight | 12 kg |
| Power Supply | AC 220 V / 50 Hz |
| Power Consumption | 150 W |
| Environmental Operating Conditions | 5–40 °C, <85% RH |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | BAC-420R |
| Measurement Mode | Adiabatic Calorimetry |
| Adiabatic Chamber Dimensions | 420 × 520 mm (L × W) |
| Temperature Control Range | RT+5°C to 300°C (optional low-temp module down to −25°C) |
| Temperature Resolution | 0.001°C |
| Chamber Temperature Stability | ±0.05°C |
| Self-Heating Detection Sensitivity | 0.02–0.05°C/min |
| Temperature Tracking Rate | 0.02–13°C/min |
| Wall-to-Sample Temperature Difference (Isothermal Mode) | <0.5°C |
| Max Sample Length | 600 mm |
| Compliance | GB/T 36276-2023, GB 38031-2020, SN/T 3078.1-2012, SAE J2464-2009, SAND2005-3123, UL 9540A-2019, SAND99-0497-1999 |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Model | HWP28-10S |
| Working Environment | (-5–45)°C, <95% RH |
| Test Vessel Material | ASTM A240 S31603 Stainless Steel (316L) |
| Pressure Vessel Rating | ≥5 MPa |
| Test Vessel Volume | ≥5 L |
| Ultimate Vacuum | ≤0.1 kPa |
| Leak Rate | ≤0.01 kPa/min |
| Gas Mixing Pressure Sensor Range | 0–200 kPa |
| Gas Mixing Pressure Sensor Accuracy | ≤±0.1% FS |
| Ignition Rod Diameter | ≥3 mm |
| Ni-Cr Wire Diameter | 0.05–0.2 mm |
| Ignition Energy | 10–20 J |
| Explosion Pressure Sensor Range | 0–5000 kPa |
| Explosion Pressure Sensor Overpressure Rating | ≥10 MPa |
| Explosion Pressure Sensor Accuracy | ±0.1% FS |
| Explosion Pressure Sensor Response Time | ≤0.5 ms |
| Explosion Temperature Measurement Range | -50–350°C |
| Explosion Temperature Accuracy | ≤±(0.15 + 0.002 |
| System Sampling Frequency | ≥2 kHz |
| Timing Range | 0–24 h, Resolution: ±0.01 s |
| Magnetic Stirring Speed | ≥300 rpm |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Product Origin | Domestic (China) |
| Model | FP CC-420A |
| Detection Method | Closed-Cup Method |
| Temperature Range | −30 °C to 420 °C |
| Ignition Method | High-Voltage Electric Arc |
Show next