| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | HWP12-10S |
| Pricing | Available Upon Request |
| Operating Temperature | (-5 to 45) °C |
| Relative Humidity | <95% RH |
| Compressed Air Flow Range | 5–500 sccm |
| Flow Control Accuracy | ±1% FS |
| Flow Response Time | ≤1 s |
| Ignition Method | Electric Spark |
| Combustion Detection | Infrared Photodetection |
| Combustion Detection Response Time | ≤1 ms |
| Flame Propagation Velocity Range | ≤500 cm/s |
| Flame Propagation Velocity Accuracy | ±5 mm/s |
| Safety Valve Activation Pressure | 2 kg/cm² |
| Reaction Tube Dimensions | 300 mm (L) × 50 mm (ID) × 5 mm (wall thickness) |
| Maximum Inlet Gas Pressure | ≤5 MPa |
| Sample Bag Capacity | 1 L |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Model | SEG-100A |
| Operating Ambient | −5°C to 45°C, <95% RH |
| Test Chamber Temperature Range | 10°C–35°C (default setpoint: 20°C, software-adjustable) |
| Temperature Stability | ±0.5°C |
| Water Addition Volume | 400 mL (automated sample immersion) |
| Sample Cup Capacity | 20 mL |
| Gas Volume Measurement Accuracy | ±0.5 mL |
| Maximum Gas Collection Capacity | 0–800 mL |
| Gas Volume Resolution | 0.01 mL |
| Gas Evolution Rate Range | 0–100 L/min/kg |
| Gas Sampling Interval | 1 s |
| Rate Calculation Interval | 1 min–1 h (software-configurable) |
| Total Timing Range | 0–240 h |
| Water Injection Volume | 300 mL |
| Water Injection Accuracy | ≤±1 mL |
| Pressure Measurement Range | −5 kPa to +5 kPa |
| Pressure Measurement Accuracy | ±0.1% FS |
| Optional Mass Measurement Range | 0–3100 g |
| Mass Measurement Accuracy | ±0.01 g |
| Water Bath Temperature Control | 20°C ±0.5°C (adjustable) |
| Brand | Young Instruments |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Manufacturer |
| Model | HWP28-10S |
| Working Environment | (-5–45)°C, <95% RH |
| Test Vessel Material | ASTM A240 S31603 Stainless Steel (316L) |
| Pressure Vessel Rating | ≥5 MPa |
| Test Vessel Volume | ≥5 L |
| Ultimate Vacuum | ≤0.1 kPa |
| Leak Rate | ≤0.01 kPa/min |
| Gas Mixing Pressure Sensor Range | 0–200 kPa |
| Gas Mixing Pressure Sensor Accuracy | ≤±0.1% FS |
| Ignition Rod Diameter | ≥3 mm |
| Ni-Cr Wire Diameter | 0.05–0.2 mm |
| Ignition Energy | 10–20 J |
| Explosion Pressure Sensor Range | 0–5000 kPa |
| Explosion Pressure Sensor Overpressure Rating | ≥10 MPa |
| Explosion Pressure Sensor Accuracy | ±0.1% FS |
| Explosion Pressure Sensor Response Time | ≤0.5 ms |
| Explosion Temperature Measurement Range | -50–350°C |
| Explosion Temperature Accuracy | ≤±(0.15 + 0.002 |
| System Sampling Frequency | ≥2 kHz |
| Timing Range | 0–24 h, Resolution: ±0.01 s |
| Magnetic Stirring Speed | ≥300 rpm |