| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 + K1124 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Analyzer |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 2.8–3 min per sample |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2 / 0.4 / 1.0 µL/step (selectable) |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 460 × 360 × 725 mm |
| Net Weight | 38 kg |
| K1124 Autosampler | 24-position, 300 mL digestion tube capacity, integrated CAN interface, 24 VDC, 40 W, 920 × 625 × 908 mm, 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D200 |
| Analysis Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Sample Throughput | 3–4 min per sample |
| Repeatability | ≤0.5% RSD |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Temperature Stability | ≤0.01 °C |
| Combustion Furnace Max Temp | 1200 °C |
| Carrier Gas | CO₂ (≥99.999% purity) |
| Oxygen Purity | ≥99.999% |
| Autosampler | 120-position single tray |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1100 |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Repeatability | ≤0.5% RSD |
| Recovery Rate | ≥99.5% |
| Steam Generation Control | Adjustable flow with real-time distillate temperature monitoring |
| Distillation Time | Programmable |
| Titration Resolution | 1.0 µL/step |
| Cooling Water Consumption | 1.5 L/min |
| Data Storage Capacity | 1800 test records |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Rated Power | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Net Weight | 38 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9840 |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 0–60 min |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1.3 kW |
| Dimensions (L×W×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9860 |
| Nitrogen Determination Range | 0.1 mg – 200 mg |
| Distillation Time | 5–10 min per sample |
| Repeatability | ±0.5% RSD |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Touchscreen | 5.6-inch color LCD |
| Titration Resolution | 2.0 µL/step |
| Cooling Water Flow | 1.5 L/min |
| Data Storage | 1000 methods/results |
| Voltage | 220 VAC ±10%, 50 Hz |
| Net Weight | 38 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D50 |
| Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Analysis Time | 3–4 min per sample |
| Repeatability | ≤0.5% RSD (using 150 mg of 10% N standard) |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | >99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | Up to 1200 °C |
| Carrier Gas | CO₂ (99.999% purity) |
| Oxygen Supply | High-purity O₂ (99.999%) |
| Autosampler Capacity | 1 × 60 positions |
| Calibration | Linear or user-defined non-linear curve |
| Communication Interface | RS485 (internal), RS232/USB (external) |
| Operating Environment | 15–30 °C, ≤85% RH |
| Weight | 80 kg |