| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N70 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Interferometry |
| Wavenumber Range | 3750–12500 cm⁻¹ |
| Scan Speed | <1 s (at 8 cm⁻¹ resolution) |
| Data Sampling Intervals | 2, 4, 8, or 16 cm⁻¹ |
| Measurement Modes | Integrating Sphere Diffuse Reflectance / Transflectance |
| Chemometrics Software | PLSQ — Partial Least Squares Spectral Modeling System |
| Detector | TEC-cooled InGaAs (2-stage thermoelectric cooling) |
| Resolution | <2 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Accuracy | <0.1 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Reproducibility | <0.04 cm⁻¹ @ 7306.74 cm⁻¹ |
| Inter-instrument Wavenumber Reproducibility | <0.05 cm⁻¹ @ 7306.74 cm⁻¹ |
| Absorbance Precision | ±0.1% T |
| Sample Measurement Time | <30 s |
| Dimensions | 445 × 237 × 320 mm |
| Weight | 20 kg |
| Power Consumption | 60 W |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i6 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise Level | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3-step selectable) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported deuterium lamp & tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T910 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| mV Range | −2000.0 to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Electrode Readout Accuracy | RSD ≤ 0.3% |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Titration Resolution | 1/1,500,000 |
| Temperature Range | −5 to 120 °C |
| Temp. Accuracy | ±0.1 °C |
| Titration Tube Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Refill Time (100% fill) | 16 s |
| Communication Interfaces | Dual USB, RS-232, Ethernet, CAN bus |
| Electrode Ports | mV/pH input, reference electrode port, PT1000 temperature probe port |
| Audit Trail | FDA 21 CFR Part 11 compliant |
| Electronic Signature | Supported |
| Data Integrity | Immutable export with checksum verification |
| User Management | Role-based, multi-level permissions |
| Sample Handling | Standalone station or optional auto-samplers (16×100 mL, 12×250 mL, 18×50 mL) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Principle | Micro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI) |
| Wavelength Range | 1750–2150 nm (extendable to 2450 nm) |
| Detector | InGaAs |
| Wavelength Resolution (FWHM) | ≤20 nm (≤1% of operating wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Sample Measurement Time | <30 s |
| Light Source Lifetime | 5000 h |
| Measurement Mode | Diffuse Reflectance |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Included Computing Platform | Microsoft Surface tablet |
| Software | MEMS Chemometrics Suite |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | BreathSpec® |
| Inlet | 6-port valve direct injection |
| Sensitivity | sub-ppb (parts-per-trillion detectable) |
| Library | VOC-specific GC×IMS spectral library |
| Mobility Resolution | TOF-IMS with 5 kV/10 cm drift field |
| Weight | 20 kg |
| Integrated Components | Onboard computer, internal gas supply, spirometer for CO₂/O₂ flow monitoring |
| Sampling Modes | Direct exhaled breath, static headspace (oral/nasal cavity), dermal micro-sampling |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 + K1124 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Analyzer |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 2.8–3 min per sample |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2 / 0.4 / 1.0 µL/step (selectable) |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 460 × 360 × 725 mm |
| Net Weight | 38 kg |
| K1124 Autosampler | 24-position, 300 mL digestion tube capacity, integrated CAN interface, 24 VDC, 40 W, 920 × 625 × 908 mm, 80 kg |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | GC-IMS |
| Detection Limit | <1 ppb (v/v) |
| Sample Introduction | 6-port valve direct injection |
| Library | VOC-specific ion mobility spectral library |
| Operating Mode | Switchable positive/negative ion mode |
| Portability | Field-deployable, battery- and vehicle-power compatible |
| Compliance | Designed for ISO 16000-6, ASTM D5197, US EPA Method TO-15/TO-17 context |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D200 |
| Analysis Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Sample Throughput | 3–4 min per sample |
| Repeatability | ≤0.5% RSD |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Temperature Stability | ≤0.01 °C |
| Combustion Furnace Max Temp | 1200 °C |
| Carrier Gas | CO₂ (≥99.999% purity) |
| Oxygen Purity | ≥99.999% |
| Autosampler | 120-position single tray |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N550 |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | MEMS Micro-Electro-Mechanical Systems Spectral Modulation |
| Wavelength Range | 900–1700 nm |
| Detector | Thermoelectrically Cooled InGaAs Array (256 pixels) |
| Slit Width | 50 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Signal-to-Noise Ratio | ≥3000 |
| Measurement Time per Sample | <30 s |
| Sampling Mode | Diffuse Reflectance |
| Sample Holders | 10 cm wide-mouth cup & 3 cm powder cup |
| Dimensions (L×W×H) | 450 × 280 × 228 mm |
| Weight | 15 kg |
| Compliance | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture |
| Chemometrics Software | MEMS Quantitative Analysis Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −20.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Meter Accuracy | ±0.1 mV, ±0.003 pH, ±0.1 °C |
| High-Resolution Mode (Optional) | 0.05 mV, 0.0001 pH |
| Meter Resolution | 0.1 mV, 0.001 pH, 0.1 °C |
| Titration Accuracy | ±0.2% |
| Titration Resolution | 1/48,000 |
| Burette Options | Standard 10 mL |
| Burette Refill Time | 16 s (at 100% fill rate) |
| Stirring Method | Magnetic stirring |
| Electrode Interfaces | mV/pH input, reference electrode input, PT1000 temperature probe input |
| Communication Ports | 2× USB, RS232, power interface |
| Data Storage | 4 GB internal flash memory with multi-level search capability |
| User Management | Four-tier permission system with customizable access rights, electronic signature support, audit-trail-enabled data integrity controls, password policy enforcement (complexity, aging, expiration) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1100 |
| Instrument Type | Kjeldahl Nitrogen Analyzer |
| Automation Level | Fully Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Repeatability | ≤0.5% RSD |
| Recovery Rate | ≥99.5% |
| Steam Generation Control | Adjustable flow with real-time distillate temperature monitoring |
| Distillation Time | Programmable |
| Titration Resolution | 1.0 µL/step |
| Cooling Water Consumption | 1.5 L/min |
| Data Storage Capacity | 1800 test records |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Rated Power | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Net Weight | 38 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9840 |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 0–60 min |
| Repeatability | ±0.5% |
| Sample Weight Capacity | ≤6 g (solid) / ≤16 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 1.3 kW |
| Dimensions (L×W×H) | 400 × 385 × 735 mm |
| Net Weight | 30 kg |
| Compliance | GB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983 |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i7 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at 656.1 nm (D₂ line), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (user-selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3 modes) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported Tungsten and Deuterium Lamps |
| Detector Type | Imported Silicon Photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T931 |
| Titration Method | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Moisture Measurement Range | 10 µg H₂O to 200 mg H₂O |
| Water Content Range | 0.0001%–100% (w/w) |
| Measurement Resolution | 0.001 µg H₂O (0.093 µg H₂O detection limit) |
| Current Resolution | 0.01 µA |
| Polarization Current Range | 1–24 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Electrolysis Current Options | 1, 2, 5, 10, 20, 50, 100, 200, 400 mA |
| Max. Electrolysis Rate | 37.34 µg H₂O/s (2240 µg H₂O/min) |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.001 mL |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Output Voltage | 24 V DC |
| Data Storage | 8 GB internal flash memory |
| Display | 10-inch capacitive TFT touchscreen (Android-based UI) |
| Compliance | FDA 21 CFR Part 11, audit trail, four-tier user permission system, electronic signature, data integrity controls |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T960 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| mV Measurement Range | −2000.0 mV to +2000.0 mV |
| mV Resolution & Accuracy | 0.1 mV resolution, ±0.1 mV ± 0.03% accuracy |
| pH Measurement Range | −20.000 to +20.000 pH |
| pH Resolution & Accuracy | 0.001 pH resolution, ±0.003 pH accuracy |
| Temperature Measurement Range | −5 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Burette Resolution | 1/1,500,000 |
| Burette Volume Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Auxiliary Reagent Channels | Up to 4+4 (8-channel synchronized dosing) |
| Electrode Interfaces | mV/pH, reference, PT1000 temperature, optional polarographic |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T930 |
| Titration Method | Fully Automated Volumetric Karl Fischer |
| Moisture Range | 0.001–100% (recommended: 0.1–100%) |
| Polarization Current Range | 1–24 µA |
| Polarization Current Resolution | 0.01 µA |
| Polarization Current Accuracy | ±0.05 µA |
| Voltage Range | 0–1999 mV |
| Voltage Resolution | 0.1 mV |
| Voltage Accuracy | ±0.2 mV |
| Titration Control Precision | 1/1,500,000 |
| Minimum Dispense Volume | 0.0001 mL |
| Standard Burette Capacity | 5 mL (optional: 1 mL or 10 mL) |
| Burette Accuracy | ±0.01 mL (1 mL), ±0.01 mL (5 mL), ±0.02 mL (10 mL) |
| Drift Resolution | 0.1 µg/min |
| Dynamic Delivery Rate | 0.02 µL/s to 0.1 mL/s (auto-switching) |
| Sample Cell Volume | 120 mL |
| Stirring | Integrated Magnetic Stirrer (manual/automatic modes) |
| Display | 10-inch capacitive TFT touchscreen |
| Data Storage | 8 GB internal flash memory |
| Export Formats | Excel, PDF |
| Communication Interfaces | Wi-Fi, USB, RS-232, BNC |
| Power Input | 100–240 V AC ±10%, 50–60 Hz |
| Compliance | FDA 21 CFR Part 11 (audit trail, role-based access control, electronic signatures) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i5 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| A/D Resolution | 24-bit |
| Baseline Flatness | ±0.001 A |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.15% T |
| Drift | ≤0.001 A/h (at 500 nm) |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (user-selectable) |
| Display | 320 × 240 LCD |
| Light Sources | Imported Deuterium & Tungsten Lamps |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K9860 |
| Nitrogen Determination Range | 0.1 mg – 200 mg |
| Distillation Time | 5–10 min per sample |
| Repeatability | ±0.5% RSD |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 455 mm × 391 mm × 730 mm |
| Touchscreen | 5.6-inch color LCD |
| Titration Resolution | 2.0 µL/step |
| Cooling Water Flow | 1.5 L/min |
| Data Storage | 1000 methods/results |
| Voltage | 220 VAC ±10%, 50 Hz |
| Net Weight | 38 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i2 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Wavelength Scanning | Automatic |
| A/D Resolution | 24-bit |
| Data Storage | 200 measurement sets + 200 calibration curves |
| Baseline Flatness | ±0.001 A |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.15% T |
| Drift | ±0.001 A/h at 500 nm |
| Noise | ±0.0005 A/h |
| Photometric Range | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Display | 128 × 64 LCD |
| Interface | USB port for data export |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 15 kg |
| Brand | Wooking |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | K2025 |
| Instrument Type | Conventional HPLC System |
| Application Scope | General-Purpose Analytical HPLC |
| Flow Rate Range | 0.001–10.000 mL/min |
| Maximum Pressure | 62 MPa |
| Flow Accuracy | RSD ≤ 0.1% |
| Sample Tray Capacity | 108 positions |
| Injection Volume Range | 0–100 µL |
| Column Oven Temperature Range | (Ambient −10)°C to 85°C |
| UV-Vis Wavelength Range | 190–900 nm |
| Data Acquisition Rate | Up to 100 Hz |
| Brand | Spectral Engines |
|---|---|
| Origin | Finland |
| Model | NIRONE DEVICE |
| Instrument Type | Portable NIR Spectrometer |
| Operating Principle | Micro-Electro-Mechanical Systems (MEMS)-Based Fabry–Pérot Interferometer |
| Wavelength Range | 1150–1950 nm (standard configuration) |
| Spectral Acquisition Time | <50 ms per spectrum |
| Spectral Sampling Interval | Adjustable from 1 to 10 nm |
| Optical Measurement Modes | Diffuse Reflectance and Transmission |
| Detector | Single-pixel InGaAs photodiode with integrated thermoelectric stabilization |
| Spectral Resolution (FWHM) | 15–25 nm |
| Wavelength Tuning Speed | <1 ms per step |
| Tuning Step Size | 0.1 nm (up to 512 discrete wavelengths) |
| Data Interfaces | Bluetooth 5.0 + USB 2.0 (micro-USB) |
| Onboard Power | Rechargeable Li-ion battery (≥8 h typical operation) |
| Software Suite | NIRSA Chemometrics Platform + SensorControl PC/Android/iOS Application |
| Compliance | CE, RoHS, FCC Part 15 Class B |
| Firmware Architecture | Field-upgradable via OTA or USB |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Model | FlavourSpec®25 |
| Sample Introduction | Headspace (HS) |
| Sensitivity | <1 ppb (without preconcentration) |
| Data Output Formats | 2D chromatogram (GC × IMS), 3D spectrochromatogram, fingerprint plot |
| Detection Principle | Drift Tube Ion Mobility Spectrometry coupled with Capillary Gas Chromatography |
| Operating Pressure | Ambient atmospheric pressure |
| Instrument Architecture | Time-of-Flight (TOF)-based IMS detector with integrated thermal desorption and GC column |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D50 |
| Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Analysis Time | 3–4 min per sample |
| Repeatability | ≤0.5% RSD (using 150 mg of 10% N standard) |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | >99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| Combustion Temperature | Up to 1200 °C |
| Carrier Gas | CO₂ (99.999% purity) |
| Oxygen Supply | High-purity O₂ (99.999%) |
| Autosampler Capacity | 1 × 60 positions |
| Calibration | Linear or user-defined non-linear curve |
| Communication Interface | RS485 (internal), RS232/USB (external) |
| Operating Environment | 15–30 °C, ≤85% RH |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i3 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.3 nm |
| Stray Light | ≤0.03% T |
| Wavelength Setting | Automatic |
| Photometric Range | 0–200% T, –0.3–3 A, 0–9999 C |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ≤0.2% T |
| Baseline Stability | ±0.001 A/h at 500 nm |
| Display | 128×64 dot-matrix LCD |
| Data Interface | USB |
| Printer Interface | Parallel port |
| Light Sources | Imported deuterium and tungsten lamps |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 420 × 300 × 160 mm |
| Weight | 13 kg |