BrandHanon
OriginShandong, China
ModelN70
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform Interferometry
Wavenumber Range3750–12500 cm⁻¹
Scan Speed<1 s (at 8 cm⁻¹ resolution)
Data Sampling Intervals2, 4, 8, or 16 cm⁻¹
Measurement ModesIntegrating Sphere Diffuse Reflectance / Transflectance
Chemometrics SoftwarePLSQ — Partial Least Squares Spectral Modeling System
DetectorTEC-cooled InGaAs (2-stage thermoelectric cooling)
Resolution<2 cm⁻¹ @ 7306.74 cm⁻¹
Wavenumber Accuracy<0.1 cm⁻¹ @ 7306.74 cm⁻¹
Wavenumber Reproducibility<0.04 cm⁻¹ @ 7306.74 cm⁻¹
Inter-instrument Wavenumber Reproducibility<0.05 cm⁻¹ @ 7306.74 cm⁻¹
Absorbance Precision±0.1% T
Sample Measurement Time<30 s
Dimensions445 × 237 × 320 mm
Weight20 kg
Power Consumption60 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli6
Optical DesignDouble-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability±0.15% T
Baseline Flatness±0.001 A
Drift≤0.001 A/h at 500 nm
Noise Level≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3-step selectable)
A/D Resolution24-bit
Display320 × 240 LCD
Light SourcesImported deuterium lamp & tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions470 × 370 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelT910
Instrument TypeUniversal Potentiometric Titrator
Application ScopeGeneral-purpose
Measurement Range0–300 mg KOH/100 g dry matter
mV Range−2000.0 to +2000.0 mV
pH Range−20.000 to +20.000 pH
Electrode Readout AccuracyRSD ≤ 0.3%
Resolution0.01 mg KOH/100 g dry matter
Titration Resolution1/1,500,000
Temperature Range−5 to 120 °C
Temp. Accuracy±0.1 °C
Titration Tube Options1 mL / 5 mL / 10 mL / 25 mL
Refill Time (100% fill)16 s
Communication InterfacesDual USB, RS-232, Ethernet, CAN bus
Electrode PortsmV/pH input, reference electrode port, PT1000 temperature probe port
Audit TrailFDA 21 CFR Part 11 compliant
Electronic SignatureSupported
Data IntegrityImmutable export with checksum verification
User ManagementRole-based, multi-level permissions
Sample HandlingStandalone station or optional auto-samplers (16×100 mL, 12×250 mL, 18×50 mL)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN500
Instrument TypePortable
PrincipleMicro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI)
Wavelength Range1750–2150 nm (extendable to 2450 nm)
DetectorInGaAs
Wavelength Resolution (FWHM)≤20 nm (≤1% of operating wavelength)
Wavelength Accuracy±1 nm
Signal-to-Noise Ratio (SNR)≥3000
Sample Measurement Time<30 s
Light Source Lifetime5000 h
Measurement ModeDiffuse Reflectance
Dimensions (L×W×H)395 × 280 × 215 mm
Weight5.5 kg
Included Computing PlatformMicrosoft Surface tablet
SoftwareMEMS Chemometrics Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandG.A.S.
OriginGermany
ModelBreathSpec®
Inlet6-port valve direct injection
Sensitivitysub-ppb (parts-per-trillion detectable)
LibraryVOC-specific GC×IMS spectral library
Mobility ResolutionTOF-IMS with 5 kV/10 cm drift field
Weight20 kg
Integrated ComponentsOnboard computer, internal gas supply, spirometer for CO₂/O₂ flow monitoring
Sampling ModesDirect exhaled breath, static headspace (oral/nasal cavity), dermal micro-sampling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelK1160 + K1124
Instrument TypeFully Automated Kjeldahl Nitrogen Analyzer
Nitrogen Determination Range0.1–240 mg N
Distillation Time2.8–3 min per sample
Repeatability (RSD)≤0.5%
Sample Weight Capacity≤5 g (solid), ≤20 mL (liquid)
Nitrogen Recovery Rate≥99.5%
Titration Resolution0.2 / 0.4 / 1.0 µL/step (selectable)
Power Consumption2 kW
Dimensions (L×W×H)460 × 360 × 725 mm
Net Weight38 kg
K1124 Autosampler24-position, 300 mL digestion tube capacity, integrated CAN interface, 24 VDC, 40 W, 920 × 625 × 908 mm, 80 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandG.A.S.
OriginGermany
ModelGC-IMS
Detection Limit<1 ppb (v/v)
Sample Introduction6-port valve direct injection
LibraryVOC-specific ion mobility spectral library
Operating ModeSwitchable positive/negative ion mode
PortabilityField-deployable, battery- and vehicle-power compatible
ComplianceDesigned for ISO 16000-6, ASTM D5197, US EPA Method TO-15/TO-17 context
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelD200
Analysis PrincipleDumas Combustion Method
Nitrogen Range0.1–500 mg
Sample Throughput3–4 min per sample
Repeatability≤0.5% RSD
Sample Mass≤1 g (solid) or ≤1 mL (liquid)
Recovery Rate≥99.5%
Power Consumption2000 W
Dimensions (L×W×H)735 mm × 560 mm × 560 mm
DetectorThermal Conductivity Detector (TCD)
TCD Temperature Stability≤0.01 °C
Combustion Furnace Max Temp1200 °C
Carrier GasCO₂ (≥99.999% purity)
Oxygen Purity≥99.999%
Autosampler120-position single tray
Weight80 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN550
Instrument TypeLaboratory NIR Spectrometer
PrincipleMEMS Micro-Electro-Mechanical Systems Spectral Modulation
Wavelength Range900–1700 nm
DetectorThermoelectrically Cooled InGaAs Array (256 pixels)
Slit Width50 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.2 nm
Signal-to-Noise Ratio≥3000
Measurement Time per Sample<30 s
Sampling ModeDiffuse Reflectance
Sample Holders10 cm wide-mouth cup & 3 cm powder cup
Dimensions (L×W×H)450 × 280 × 228 mm
Weight15 kg
ComplianceASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture
Chemometrics SoftwareMEMS Quantitative Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelT860
Instrument TypeGeneral-purpose Potentiometric Titrator
Application ScopeUniversal
Measurement RangemV: −2000.0 to +2000.0 mV
pH−20.000 to +20.000 pH
Temperature−5 to 120 °C
Meter Accuracy±0.1 mV, ±0.003 pH, ±0.1 °C
High-Resolution Mode (Optional)0.05 mV, 0.0001 pH
Meter Resolution0.1 mV, 0.001 pH, 0.1 °C
Titration Accuracy±0.2%
Titration Resolution1/48,000
Burette OptionsStandard 10 mL
Burette Refill Time16 s (at 100% fill rate)
Stirring MethodMagnetic stirring
Electrode InterfacesmV/pH input, reference electrode input, PT1000 temperature probe input
Communication Ports2× USB, RS232, power interface
Data Storage4 GB internal flash memory with multi-level search capability
User ManagementFour-tier permission system with customizable access rights, electronic signature support, audit-trail-enabled data integrity controls, password policy enforcement (complexity, aging, expiration)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelK1100
Instrument TypeKjeldahl Nitrogen Analyzer
Automation LevelFully Automated
Nitrogen Determination Range0.1–240 mg N
Sample Weight Capacity≤5 g (solid), ≤20 mL (liquid)
Repeatability≤0.5% RSD
Recovery Rate≥99.5%
Steam Generation ControlAdjustable flow with real-time distillate temperature monitoring
Distillation TimeProgrammable
Titration Resolution1.0 µL/step
Cooling Water Consumption1.5 L/min
Data Storage Capacity1800 test records
Power Supply220 V AC ±10%, 50 Hz
Rated Power2 kW
Dimensions (L×W×H)455 mm × 391 mm × 730 mm
Net Weight38 kg
ComplianceGB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelK9840
Nitrogen Determination Range0.1–240 mg N
Distillation Time0–60 min
Repeatability±0.5%
Sample Weight Capacity≤6 g (solid) / ≤16 mL (liquid)
Nitrogen Recovery Rate≥99.5%
Power Consumption1.3 kW
Dimensions (L×W×H)400 × 385 × 735 mm
Net Weight30 kg
ComplianceGB, NY, HJ, Chinese Pharmacopoeia, AOAC Official Methods, ISO 8968 & ISO 5983
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli7
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm at 656.1 nm (D₂ line), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (user-selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability±0.15% T
Baseline Flatness±0.001 A
Drift≤0.001 A/h at 500 nm
Noise≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3 modes)
A/D Resolution24-bit
Display320 × 240 LCD
Light SourcesImported Tungsten and Deuterium Lamps
Detector TypeImported Silicon Photodiode
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions470 × 370 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelT931
Titration MethodFully Automatic Coulometric Titration
Instrument TypeCoulometric Karl Fischer Moisture Analyzer
Moisture Measurement Range10 µg H₂O to 200 mg H₂O
Water Content Range0.0001%–100% (w/w)
Measurement Resolution0.001 µg H₂O (0.093 µg H₂O detection limit)
Current Resolution0.01 µA
Polarization Current Range1–24 µA
Polarization Current Accuracy±0.05 µA
Voltage Range0–1999 mV
Voltage Resolution0.1 mV
Voltage Accuracy±0.2 mV
Electrolysis Current Options1, 2, 5, 10, 20, 50, 100, 200, 400 mA
Max. Electrolysis Rate37.34 µg H₂O/s (2240 µg H₂O/min)
Titration Control Precision1/1,500,000
Minimum Dispense Volume0.001 mL
Power Input100–240 V AC ±10%, 50–60 Hz
Output Voltage24 V DC
Data Storage8 GB internal flash memory
Display10-inch capacitive TFT touchscreen (Android-based UI)
ComplianceFDA 21 CFR Part 11, audit trail, four-tier user permission system, electronic signature, data integrity controls
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelT960
Instrument TypeUniversal Potentiometric Titrator
Application ScopeGeneral-purpose
mV Measurement Range−2000.0 mV to +2000.0 mV
mV Resolution & Accuracy0.1 mV resolution, ±0.1 mV ± 0.03% accuracy
pH Measurement Range−20.000 to +20.000 pH
pH Resolution & Accuracy0.001 pH resolution, ±0.003 pH accuracy
Temperature Measurement Range−5 °C to 120 °C
Temperature Accuracy±0.1 °C
Temperature Resolution0.1 °C
Burette Resolution1/1,500,000
Burette Volume Options1 mL / 5 mL / 10 mL / 25 mL
Auxiliary Reagent ChannelsUp to 4+4 (8-channel synchronized dosing)
Electrode InterfacesmV/pH, reference, PT1000 temperature, optional polarographic
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelT930
Titration MethodFully Automated Volumetric Karl Fischer
Moisture Range0.001–100% (recommended: 0.1–100%)
Polarization Current Range1–24 µA
Polarization Current Resolution0.01 µA
Polarization Current Accuracy±0.05 µA
Voltage Range0–1999 mV
Voltage Resolution0.1 mV
Voltage Accuracy±0.2 mV
Titration Control Precision1/1,500,000
Minimum Dispense Volume0.0001 mL
Standard Burette Capacity5 mL (optional: 1 mL or 10 mL)
Burette Accuracy±0.01 mL (1 mL), ±0.01 mL (5 mL), ±0.02 mL (10 mL)
Drift Resolution0.1 µg/min
Dynamic Delivery Rate0.02 µL/s to 0.1 mL/s (auto-switching)
Sample Cell Volume120 mL
StirringIntegrated Magnetic Stirrer (manual/automatic modes)
Display10-inch capacitive TFT touchscreen
Data Storage8 GB internal flash memory
Export FormatsExcel, PDF
Communication InterfacesWi-Fi, USB, RS-232, BNC
Power Input100–240 V AC ±10%, 50–60 Hz
ComplianceFDA 21 CFR Part 11 (audit trail, role-based access control, electronic signatures)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli5
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.2 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
A/D Resolution24-bit
Baseline Flatness±0.001 A
Photometric Accuracy±0.3% T
Photometric Repeatability±0.15% T
Drift≤0.001 A/h (at 500 nm)
Noise≤0.0005 A
Photometric Range0–200% T, –0.3 to 3 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (user-selectable)
Display320 × 240 LCD
Light SourcesImported Deuterium & Tungsten Lamps
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions460 × 380 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelK9860
Nitrogen Determination Range0.1 mg – 200 mg
Distillation Time5–10 min per sample
Repeatability±0.5% RSD
Sample Weight Capacity≤5 g (solid), ≤20 mL (liquid)
Nitrogen Recovery Rate≥99.5%
Power Consumption2 kW
Dimensions (L×W×H)455 mm × 391 mm × 730 mm
Touchscreen5.6-inch color LCD
Titration Resolution2.0 µL/step
Cooling Water Flow1.5 L/min
Data Storage1000 methods/results
Voltage220 VAC ±10%, 50 Hz
Net Weight38 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli2
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.2 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
Wavelength ScanningAutomatic
A/D Resolution24-bit
Data Storage200 measurement sets + 200 calibration curves
Baseline Flatness±0.001 A
Photometric Accuracy±0.3% T
Photometric Repeatability≤0.15% T
Drift±0.001 A/h at 500 nm
Noise±0.0005 A/h
Photometric Range0–200% T, –0.3 to 3 A, 0–9999 C
Display128 × 64 LCD
InterfaceUSB port for data export
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions460 × 380 × 180 mm
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandWooking
OriginShandong, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelK2025
Instrument TypeConventional HPLC System
Application ScopeGeneral-Purpose Analytical HPLC
Flow Rate Range0.001–10.000 mL/min
Maximum Pressure62 MPa
Flow AccuracyRSD ≤ 0.1%
Sample Tray Capacity108 positions
Injection Volume Range0–100 µL
Column Oven Temperature Range(Ambient −10)°C to 85°C
UV-Vis Wavelength Range190–900 nm
Data Acquisition RateUp to 100 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectral Engines
OriginFinland
ModelNIRONE DEVICE
Instrument TypePortable NIR Spectrometer
Operating PrincipleMicro-Electro-Mechanical Systems (MEMS)-Based Fabry–Pérot Interferometer
Wavelength Range1150–1950 nm (standard configuration)
Spectral Acquisition Time<50 ms per spectrum
Spectral Sampling IntervalAdjustable from 1 to 10 nm
Optical Measurement ModesDiffuse Reflectance and Transmission
DetectorSingle-pixel InGaAs photodiode with integrated thermoelectric stabilization
Spectral Resolution (FWHM)15–25 nm
Wavelength Tuning Speed<1 ms per step
Tuning Step Size0.1 nm (up to 512 discrete wavelengths)
Data InterfacesBluetooth 5.0 + USB 2.0 (micro-USB)
Onboard PowerRechargeable Li-ion battery (≥8 h typical operation)
Software SuiteNIRSA Chemometrics Platform + SensorControl PC/Android/iOS Application
ComplianceCE, RoHS, FCC Part 15 Class B
Firmware ArchitectureField-upgradable via OTA or USB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandG.A.S.
OriginGermany
Manufacturer TypeAuthorized Distributor
ModelFlavourSpec®25
Sample IntroductionHeadspace (HS)
Sensitivity<1 ppb (without preconcentration)
Data Output Formats2D chromatogram (GC × IMS), 3D spectrochromatogram, fingerprint plot
Detection PrincipleDrift Tube Ion Mobility Spectrometry coupled with Capillary Gas Chromatography
Operating PressureAmbient atmospheric pressure
Instrument ArchitectureTime-of-Flight (TOF)-based IMS detector with integrated thermal desorption and GC column
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelD50
PrincipleDumas Combustion Method
Nitrogen Range0.1–500 mg
Analysis Time3–4 min per sample
Repeatability≤0.5% RSD (using 150 mg of 10% N standard)
Sample Mass≤1 g (solid) or ≤1 mL (liquid)
Recovery Rate>99.5%
Power Consumption2000 W
Dimensions (L×W×H)735 mm × 560 mm × 560 mm
DetectorThermal Conductivity Detector (TCD)
Combustion TemperatureUp to 1200 °C
Carrier GasCO₂ (99.999% purity)
Oxygen SupplyHigh-purity O₂ (99.999%)
Autosampler Capacity1 × 60 positions
CalibrationLinear or user-defined non-linear curve
Communication InterfaceRS485 (internal), RS232/USB (external)
Operating Environment15–30 °C, ≤85% RH
Weight80 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli3
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.3 nm
Stray Light≤0.03% T
Wavelength SettingAutomatic
Photometric Range0–200% T, –0.3–3 A, 0–9999 C
Photometric Accuracy±0.5% T
Photometric Repeatability≤0.2% T
Baseline Stability±0.001 A/h at 500 nm
Display128×64 dot-matrix LCD
Data InterfaceUSB
Printer InterfaceParallel port
Light SourcesImported deuterium and tungsten lamps
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions420 × 300 × 160 mm
Weight13 kg