- All
- Favorite
- Popular
- Most rated
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Region | Domestic (China) |
| Model | W100 |
| Pricing | Available Upon Request |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | A630 |
| Instrument Type | Benchtop Refractometer |
| Temperature Control | Peltier-based |
| Digital Display | Yes |
| Refractive Index Range | 1.3000–1.7000 (nD) |
| Brix Accuracy | ±0.1% |
| nD Resolution | 0.0001 |
| Temperature Control Range | 10–50 °C |
| Temperature Stability | ±0.05 °C |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Data Storage | 4 GB internal |
| Connectivity | 2× USB, RS232, Ethernet |
| Prism Material | Sapphire-grade optical glass |
| Light Source | >100,000 h LED |
| Compliance | FDA 21 CFR Part 11 (audit trail, user roles, electronic signature support) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FCLW6-20 |
| Bath Volume | 6 L |
| Temperature Range | -20 °C to 100 °C |
| Temperature Stability | ±0.05 °C |
| Display Resolution | 0.1 °C |
| Pump Flow Rate | 10 L/min |
| Pump Pressure | 0.35 bar |
| Heating Power | 1000 W |
| Cooling Power | 250 W |
| Refrigerant | R134a |
| Temperature Sensor | PT100 |
| Control Algorithm | Fuzzy PID |
| Circulation Mode | Internal & External |
| Protection Features | Over-current, High/Low Temperature, Over-temperature, Low-level Audio-Visual Alarm |
| Power Supply | 220 V AC ±10%, 50 Hz |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP360 |
| Temperature Range | 0–100 °C |
| Heating Rate | 0.1–20.0 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.3 °C |
| Capillary Dimensions | ID 0.9–1.1 mm, Wall Thickness 0.10–0.15 mm (optional 1.6 mm OD) |
| Sample Capacity | 3 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 32 GB internal |
| Video Storage | ~10,000 minutes (H.264 encoded) |
| Compliance | FDA 21 CFR Part 11, ASTM D3104, GB/T 24892–2010, GB/T 12766–2008, SN/T 0801.5–1999 |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Calibration | Multi-point temperature calibration |
| User Management | Role-based access control with audit trail |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N70 |
| Instrument Type | Laboratory FT-NIR Spectrometer |
| Principle | Fourier Transform Interferometry |
| Wavenumber Range | 3750–12500 cm⁻¹ |
| Scan Speed | <1 s (at 8 cm⁻¹ resolution) |
| Data Sampling Intervals | 2, 4, 8, or 16 cm⁻¹ |
| Measurement Modes | Integrating Sphere Diffuse Reflectance / Transflectance |
| Chemometrics Software | PLSQ — Partial Least Squares Spectral Modeling System |
| Detector | TEC-cooled InGaAs (2-stage thermoelectric cooling) |
| Resolution | <2 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Accuracy | <0.1 cm⁻¹ @ 7306.74 cm⁻¹ |
| Wavenumber Reproducibility | <0.04 cm⁻¹ @ 7306.74 cm⁻¹ |
| Inter-instrument Wavenumber Reproducibility | <0.05 cm⁻¹ @ 7306.74 cm⁻¹ |
| Absorbance Precision | ±0.1% T |
| Sample Measurement Time | <30 s |
| Dimensions | 445 × 237 × 320 mm |
| Weight | 20 kg |
| Power Consumption | 60 W |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i6 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise Level | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3-step selectable) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported deuterium lamp & tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T910 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| mV Range | −2000.0 to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Electrode Readout Accuracy | RSD ≤ 0.3% |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Titration Resolution | 1/1,500,000 |
| Temperature Range | −5 to 120 °C |
| Temp. Accuracy | ±0.1 °C |
| Titration Tube Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Refill Time (100% fill) | 16 s |
| Communication Interfaces | Dual USB, RS-232, Ethernet, CAN bus |
| Electrode Ports | mV/pH input, reference electrode port, PT1000 temperature probe port |
| Audit Trail | FDA 21 CFR Part 11 compliant |
| Electronic Signature | Supported |
| Data Integrity | Immutable export with checksum verification |
| User Management | Role-based, multi-level permissions |
| Sample Handling | Standalone station or optional auto-samplers (16×100 mL, 12×250 mL, 18×50 mL) |
| Brand | Hanon |
|---|---|
| Model | BS580D |
| Chamber Volume | 360 L |
| Heating Power | 9 kW |
| Maximum Wash Temperature | 93 °C |
| Wash Solution Compatibility | Acidic & Alkaline Liquid Detergents |
| External Dimensions (L×W×D) | 1800 × 785 × 765 mm |
| Power Supply | 380 V / 50 Hz (3-phase) |
| Control System | Programmable Logic Controller (PLC) with Touchscreen Interface |
| Wash Cycle Duration | Adjustable (Typical Range: 25–60 min) |
| Water Consumption per Cycle | ≤ 80 L |
| Drainage Capacity | ≥ 20 L/min |
| Safety Certification | CE-compliant design, IP54-rated electrical enclosure |
| Material of Chamber | 316L Stainless Steel |
| Brand | Hanon |
|---|---|
| Model | A670 |
| Type | Benchtop Refractometer |
| Temperature Control | Peltier-based, 5–80 °C (±0.02 °C) |
| Display | 7-inch capacitive touchscreen (Android OS) |
| Measurement Range | 1.30000–1.70000 (nD) |
| Accuracy | ±0.0001 (nD) |
| Resolution | 0.0001 / 0.00001 (nD) selectable |
| Brix Range | 0–100.0% (±0.1%) |
| Light Source | >100,000 hr LED |
| Prism Material | Sapphire-grade optical glass |
| Data Storage | 4 GB internal + USB backup |
| Connectivity | 2× USB, RS232, Ethernet, Wi-Fi (A670 only) |
| Compliance | FDA 21 CFR Part 11 (user roles, audit trail, electronic signature, data integrity) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N500 |
| Instrument Type | Portable |
| Principle | Micro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI) |
| Wavelength Range | 1750–2150 nm (extendable to 2450 nm) |
| Detector | InGaAs |
| Wavelength Resolution (FWHM) | ≤20 nm (≤1% of operating wavelength) |
| Wavelength Accuracy | ±1 nm |
| Signal-to-Noise Ratio (SNR) | ≥3000 |
| Sample Measurement Time | <30 s |
| Light Source Lifetime | 5000 h |
| Measurement Mode | Diffuse Reflectance |
| Dimensions (L×W×H) | 395 × 280 × 215 mm |
| Weight | 5.5 kg |
| Included Computing Platform | Microsoft Surface tablet |
| Software | MEMS Chemometrics Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | MP450 |
| Temperature Range | Ambient to 350 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.1 °C |
| Data Storage | 128 GB internal (≥40,000 min video archive) |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Connectivity | USB ×3, RS-232, Wi-Fi, RJ45 Ethernet |
| Cooling | Ambient to 50 °C in ≤7 min |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | FC1200 |
| Instrument Type | Integrated Circulating Chiller |
| Cooling Method | Water-Cooled |
| Temperature Control Range | 5.0–40.0 °C |
| Temperature Stability | ±0.3 °C |
| Refrigeration Capacity | 1200 W @ 20 °C |
| Circulating Pump Pressure | 0–1.5 bar (adjustable) |
| Flow Rate | 20 L/min |
| Reservoir Volume | 8 L |
| Operating Mode | Continuous |
| Refrigerant | R134a |
| Temperature Sensor | PT100 |
| Control Technology | PID + Hot-Gas Bypass |
| Display | Color LCD with 0.1 °C resolution |
| Dimensions | 550 × 400 × 644 mm |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Max. Head | 15 m |
| Safety Features | Over/under-temperature alarm, low-level liquid detection with audible alert, flow interruption detection (auto-switch to internal recirculation) |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | DT08 |
| Instrument Type | Offline Dissolution Tester |
| Operating System | Android-based UI on 7-inch HD color touchscreen |
| Connectivity | USB 2.0, RS-232, Wi-Fi |
| Temperature Control | Independent real-time cup-wise temperature monitoring with calibration capability |
| Safety Features | Auto self-diagnosis, preheating sequence, liquid-level sensing, dual-stage overheat protection |
| Data Management | Built-in thermal printer, audit trail, multi-level user authentication (including fingerprint unlock) |
| Optional | Integrated high-resolution dissolution video capture system |
| Regulatory Support | Designed to support 21 CFR Part 11-compliant workflows via software configuration |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SH220F |
| Instrument Type | Graphite Block Digestion System |
| Automation Level | Fully Automatic |
| Digestion Positions | 30 |
| Temperature Range | Ambient +5 °C to 450 °C |
| Temperature Control Accuracy | ±1 °C |
| Heating Principle | Infrared Radiation + High-Purity Graphite Thermal Conduction |
| Reagent Channel Capacity | Up to 20 Samples Simultaneously |
| Display | 4.3-inch Color TFT LCD |
| Programmable Methods | 10 Predefined Multi-Stage Programs (up to 5 Temp/Time Segments Each) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 3.6 kW |
| Dimensions (L×W×H) | 515 mm × 421 mm × 211 mm |
| Net Weight | 25 kg |
| Safety Protections | Over-Temperature, Over-Current, Over-Voltage, Real-Time Heating Element Diagnostics |
| Graphite Block Treatment | CVD-Coated Surface for Oxidation Resistance |
| Housing Finish | PTFE-Impregnated Stainless Steel with Ceramic Fiber + Optimized Air-Channel Insulation |
| Exhaust Integration | Compatible with WD03 Acid Fume Extraction Unit and S402 Triple-Stage Neutralization System (Water Wash + NaOH Neutralization + Activated Carbon Adsorption) |
| Digestion Vessel Compatibility | 300 mL Borosilicate or Quartz Tubes (H₂O @ 20 °C) |
| Brand | Hanon |
|---|---|
| Origin | Shanghai, China |
| Model | MP490 |
| Temperature Range | Ambient to 400 °C |
| Heating Rate | 0.1–20 °C/min |
| Temperature Repeatability | ±0.2 °C (at 0.20 °C/min) |
| Temperature Accuracy | ±0.4 °C (<200 °C), ±0.7 °C (<300 °C) |
| Capillary Dimensions | Sealed-end, OD 1.3–1.4 mm, L 110 mm |
| Sample Capacity | 4 samples per run |
| Temperature Resolution | 0.01 °C |
| Data Storage | 128 GB internal (≥40,000 min video capacity) |
| Display | 8-inch capacitive TFT touchscreen (Android OS) |
| Camera | 720p HD, 8× optical zoom |
| Compliance | FDA 21 CFR Part 11 (audit trail enabled), GLP/GMP-ready |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | BreathSpec® |
| Inlet | 6-port valve direct injection |
| Sensitivity | sub-ppb (parts-per-trillion detectable) |
| Library | VOC-specific GC×IMS spectral library |
| Mobility Resolution | TOF-IMS with 5 kV/10 cm drift field |
| Weight | 20 kg |
| Integrated Components | Onboard computer, internal gas supply, spirometer for CO₂/O₂ flow monitoring |
| Sampling Modes | Direct exhaled breath, static headspace (oral/nasal cavity), dermal micro-sampling |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | K1160 + K1124 |
| Instrument Type | Fully Automated Kjeldahl Nitrogen Analyzer |
| Nitrogen Determination Range | 0.1–240 mg N |
| Distillation Time | 2.8–3 min per sample |
| Repeatability (RSD) | ≤0.5% |
| Sample Weight Capacity | ≤5 g (solid), ≤20 mL (liquid) |
| Nitrogen Recovery Rate | ≥99.5% |
| Titration Resolution | 0.2 / 0.4 / 1.0 µL/step (selectable) |
| Power Consumption | 2 kW |
| Dimensions (L×W×H) | 460 × 360 × 725 mm |
| Net Weight | 38 kg |
| K1124 Autosampler | 24-position, 300 mL digestion tube capacity, integrated CAN interface, 24 VDC, 40 W, 920 × 625 × 908 mm, 80 kg |
| Brand | G.A.S. |
|---|---|
| Origin | Germany |
| Model | GC-IMS |
| Detection Limit | <1 ppb (v/v) |
| Sample Introduction | 6-port valve direct injection |
| Library | VOC-specific ion mobility spectral library |
| Operating Mode | Switchable positive/negative ion mode |
| Portability | Field-deployable, battery- and vehicle-power compatible |
| Compliance | Designed for ISO 16000-6, ASTM D5197, US EPA Method TO-15/TO-17 context |
| Brand | Sineo |
|---|---|
| Origin | Shandong, China |
| Model Range | TK-12 / TK-16 / TK-20 / TK-24 / TK-24D / VAVO-28 / VAVO-40 / TK-40 |
| Heating Principle | Cast-Aluminum Block with Deep-Well Design |
| Max Temperature | 240 °C (TK series) / 250 °C (VAVO series) |
| Temperature Accuracy | ±1 °C |
| Heating Uniformity | Optimized via High-Thermal-Conductivity Cast-Aluminum Block |
| Control System | Embedded PID Algorithm with Real-Time Thermal Monitoring |
| Safety Features | Over-Temperature, Over-Current, Over-Pressure, and Heating Element Fault Detection |
| Surface Finish | PTFE-Coated for HNO₃, HF, HCl, and Aqua Regia Resistance |
| Application Mode | Atmospheric-Pressure Wet Digestion & Post-Microwave Acid Evaporation |
| Compliance | Designed to support EPA Methods 3050B, 3051A, 3052 |
| Brand | Haosoo |
|---|---|
| Origin | Shandong, China |
| Model | DT12 |
| Instrument Type | Offline Dissolution Tester |
| Dissolution Vessels | 12 × 1000 mL |
| Temperature Control Range (Bath) | Ambient to 55 °C |
| Bath Temperature Resolution | 0.01 °C |
| Bath Temperature Accuracy | ±0.2 °C |
| Rotational Speed Range | 1–300 rpm |
| Paddle Wobble Amplitude | ≤0.5 mm |
| Basket Wobble Amplitude | ≤1.0 mm |
| Water Bath Volume | 40 L |
| Integrated Peristaltic/Syringe Pumps | 12 high-precision syringe pumps |
| Sample Collection Capacity | 192 × 10 mL tubes + optional 1.5 mL vial tray |
| User Interface | 7-inch HD color touchscreen with Android OS |
| Connectivity | USB, RS232, Wi-Fi |
| Compliance Features | Audit trail, multi-level user permissions, biometric fingerprint login |
| Safety | Emergency stop button, auto-level detection, overheat protection, self-diagnostic startup, real-time vessel temperature monitoring with calibration function |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | D200 |
| Analysis Principle | Dumas Combustion Method |
| Nitrogen Range | 0.1–500 mg |
| Sample Throughput | 3–4 min per sample |
| Repeatability | ≤0.5% RSD |
| Sample Mass | ≤1 g (solid) or ≤1 mL (liquid) |
| Recovery Rate | ≥99.5% |
| Power Consumption | 2000 W |
| Dimensions (L×W×H) | 735 mm × 560 mm × 560 mm |
| Detector | Thermal Conductivity Detector (TCD) |
| TCD Temperature Stability | ≤0.01 °C |
| Combustion Furnace Max Temp | 1200 °C |
| Carrier Gas | CO₂ (≥99.999% purity) |
| Oxygen Purity | ≥99.999% |
| Autosampler | 120-position single tray |
| Weight | 80 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | N550 |
| Instrument Type | Laboratory NIR Spectrometer |
| Principle | MEMS Micro-Electro-Mechanical Systems Spectral Modulation |
| Wavelength Range | 900–1700 nm |
| Detector | Thermoelectrically Cooled InGaAs Array (256 pixels) |
| Slit Width | 50 nm |
| Wavelength Accuracy | ±1 nm |
| Wavelength Repeatability | ±0.2 nm |
| Signal-to-Noise Ratio | ≥3000 |
| Measurement Time per Sample | <30 s |
| Sampling Mode | Diffuse Reflectance |
| Sample Holders | 10 cm wide-mouth cup & 3 cm powder cup |
| Dimensions (L×W×H) | 450 × 280 × 228 mm |
| Weight | 15 kg |
| Compliance | ASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture |
| Chemometrics Software | MEMS Quantitative Analysis Suite |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | SOX406 |
| Heating Method | Sealed Metal Bath |
| Temperature Range | Ambient +5 °C to 280 °C |
| Temperature Control Accuracy | ±1 °C |
| Channels | 6 |
| Receiver Flask Volume | 80 mL |
| Sample Weight Range | 0.5–15 g (typical: 2–5 g) |
| Solvent Recovery Rate | ≥80% |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Rated Power | 1 kW |
| Dimensions (L×W×H) | 650 × 320 × 715 mm |
| Net Weight | 35 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −20.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Meter Accuracy | ±0.1 mV, ±0.003 pH, ±0.1 °C |
| High-Resolution Mode (Optional) | 0.05 mV, 0.0001 pH |
| Meter Resolution | 0.1 mV, 0.001 pH, 0.1 °C |
| Titration Accuracy | ±0.2% |
| Titration Resolution | 1/48,000 |
| Burette Options | Standard 10 mL |
| Burette Refill Time | 16 s (at 100% fill rate) |
| Stirring Method | Magnetic stirring |
| Electrode Interfaces | mV/pH input, reference electrode input, PT1000 temperature probe input |
| Communication Ports | 2× USB, RS232, power interface |
| Data Storage | 4 GB internal flash memory with multi-level search capability |
| User Management | Four-tier permission system with customizable access rights, electronic signature support, audit-trail-enabled data integrity controls, password policy enforcement (complexity, aging, expiration) |
Show next