- All
- Favorite
- Popular
- Most rated
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T910 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| Measurement Range | 0–300 mg KOH/100 g dry matter |
| mV Range | −2000.0 to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Electrode Readout Accuracy | RSD ≤ 0.3% |
| Resolution | 0.01 mg KOH/100 g dry matter |
| Titration Resolution | 1/1,500,000 |
| Temperature Range | −5 to 120 °C |
| Temp. Accuracy | ±0.1 °C |
| Titration Tube Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Refill Time (100% fill) | 16 s |
| Communication Interfaces | Dual USB, RS-232, Ethernet, CAN bus |
| Electrode Ports | mV/pH input, reference electrode port, PT1000 temperature probe port |
| Audit Trail | FDA 21 CFR Part 11 compliant |
| Electronic Signature | Supported |
| Data Integrity | Immutable export with checksum verification |
| User Management | Role-based, multi-level permissions |
| Sample Handling | Standalone station or optional auto-samplers (16×100 mL, 12×250 mL, 18×50 mL) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T860 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | mV: −2000.0 to +2000.0 mV |
| pH | −20.000 to +20.000 pH |
| Temperature | −5 to 120 °C |
| Meter Accuracy | ±0.1 mV, ±0.003 pH, ±0.1 °C |
| High-Resolution Mode (Optional) | 0.05 mV, 0.0001 pH |
| Meter Resolution | 0.1 mV, 0.001 pH, 0.1 °C |
| Titration Accuracy | ±0.2% |
| Titration Resolution | 1/48,000 |
| Burette Options | Standard 10 mL |
| Burette Refill Time | 16 s (at 100% fill rate) |
| Stirring Method | Magnetic stirring |
| Electrode Interfaces | mV/pH input, reference electrode input, PT1000 temperature probe input |
| Communication Ports | 2× USB, RS232, power interface |
| Data Storage | 4 GB internal flash memory with multi-level search capability |
| User Management | Four-tier permission system with customizable access rights, electronic signature support, audit-trail-enabled data integrity controls, password policy enforcement (complexity, aging, expiration) |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | T960 |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose |
| mV Measurement Range | −2000.0 mV to +2000.0 mV |
| mV Resolution & Accuracy | 0.1 mV resolution, ±0.1 mV ± 0.03% accuracy |
| pH Measurement Range | −20.000 to +20.000 pH |
| pH Resolution & Accuracy | 0.001 pH resolution, ±0.003 pH accuracy |
| Temperature Measurement Range | −5 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Resolution | 0.1 °C |
| Burette Resolution | 1/1,500,000 |
| Burette Volume Options | 1 mL / 5 mL / 10 mL / 25 mL |
| Auxiliary Reagent Channels | Up to 4+4 (8-channel synchronized dosing) |
| Electrode Interfaces | mV/pH, reference, PT1000 temperature, optional polarographic |
Show next