| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i6 |
| Optical Design | Double-beam |
| Detector Type | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise Level | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3-step selectable) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported deuterium lamp & tungsten-halogen lamp |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i7 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm at 656.1 nm (D₂ line), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (user-selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ±0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.001 A/h at 500 nm |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3 modes) |
| A/D Resolution | 24-bit |
| Display | 320 × 240 LCD |
| Light Sources | Imported Tungsten and Deuterium Lamps |
| Detector Type | Imported Silicon Photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 470 × 370 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i5 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| A/D Resolution | 24-bit |
| Baseline Flatness | ±0.001 A |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ±0.15% T |
| Drift | ≤0.001 A/h (at 500 nm) |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (user-selectable) |
| Display | 320 × 240 LCD |
| Light Sources | Imported Deuterium & Tungsten Lamps |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 20 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i2 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.2 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm (selectable) |
| Stray Light | ≤0.03% T |
| Wavelength Scanning | Automatic |
| A/D Resolution | 24-bit |
| Data Storage | 200 measurement sets + 200 calibration curves |
| Baseline Flatness | ±0.001 A |
| Photometric Accuracy | ±0.3% T |
| Photometric Repeatability | ≤0.15% T |
| Drift | ±0.001 A/h at 500 nm |
| Noise | ±0.0005 A/h |
| Photometric Range | 0–200% T, –0.3 to 3 A, 0–9999 C |
| Display | 128 × 64 LCD |
| Interface | USB port for data export |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 460 × 380 × 180 mm |
| Weight | 15 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i3 |
| Optical Design | Double-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Spectral Bandwidth | 0.5 / 1 / 2 / 4 / 5.0 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.3 nm |
| Stray Light | ≤0.03% T |
| Wavelength Setting | Automatic |
| Photometric Range | 0–200% T, –0.3–3 A, 0–9999 C |
| Photometric Accuracy | ±0.5% T |
| Photometric Repeatability | ≤0.2% T |
| Baseline Stability | ±0.001 A/h at 500 nm |
| Display | 128×64 dot-matrix LCD |
| Data Interface | USB |
| Printer Interface | Parallel port |
| Light Sources | Imported deuterium and tungsten lamps |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 420 × 300 × 160 mm |
| Weight | 13 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i8 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 1.8 nm |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ≤0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ≤0.0004 A/h (at 500 nm) |
| Noise | ≤0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low selectable |
| Data Interface | USB |
| Display | 320 × 240 pixel LCD |
| Light Sources | Imported tungsten and deuterium lamps |
| Detector Type | Imported silicon photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 625 × 430 × 210 mm |
| Weight | 28 kg |
| Brand | Hanon |
|---|---|
| Origin | Shandong, China |
| Model | i9 |
| Optical System | Dual-beam |
| Detector | Photodiode Array (PDA) |
| Wavelength Range | 190–1100 nm |
| Wavelength Accuracy | ±0.1 nm @ 656.1 nm (D₂ line), ±0.3 nm across full range |
| Wavelength Repeatability | ≤0.1 nm |
| Spectral Bandwidth | 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (motorized, user-selectable) |
| Stray Light | ≤0.03% T |
| Photometric Accuracy | ±0.2% T |
| Photometric Repeatability | ≤0.15% T |
| Baseline Flatness | ±0.001 A |
| Drift | ±0.0004 A/h @ 500 nm |
| Noise | ±0.0005 A |
| Photometric Range | 0–200% T, –4.0 to +4.0 A, 0–9999 C |
| Wavelength Setting | Automatic |
| Scan Speed | High/Medium/Low (3 modes) |
| Data Interface | USB |
| Display | 320 × 240 pixel LCD |
| Light Sources | Imported deuterium and tungsten lamps |
| Detector | Imported silicon photodiode |
| Power Supply | AC 220 V/50 Hz or 110 V/60 Hz |
| Dimensions | 625 × 430 × 210 mm |
| Weight | 28 kg |