Empowering Scientific Discovery

Hanon Future Technology Group Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli6
Optical DesignDouble-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability±0.15% T
Baseline Flatness±0.001 A
Drift≤0.001 A/h at 500 nm
Noise Level≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3-step selectable)
A/D Resolution24-bit
Display320 × 240 LCD
Light SourcesImported deuterium lamp & tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions470 × 370 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli7
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm at 656.1 nm (D₂ line), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (user-selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability±0.15% T
Baseline Flatness±0.001 A
Drift≤0.001 A/h at 500 nm
Noise≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3 modes)
A/D Resolution24-bit
Display320 × 240 LCD
Light SourcesImported Tungsten and Deuterium Lamps
Detector TypeImported Silicon Photodiode
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions470 × 370 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli5
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.2 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
A/D Resolution24-bit
Baseline Flatness±0.001 A
Photometric Accuracy±0.3% T
Photometric Repeatability±0.15% T
Drift≤0.001 A/h (at 500 nm)
Noise≤0.0005 A
Photometric Range0–200% T, –0.3 to 3 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (user-selectable)
Display320 × 240 LCD
Light SourcesImported Deuterium & Tungsten Lamps
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions460 × 380 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli2
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.2 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
Wavelength ScanningAutomatic
A/D Resolution24-bit
Data Storage200 measurement sets + 200 calibration curves
Baseline Flatness±0.001 A
Photometric Accuracy±0.3% T
Photometric Repeatability≤0.15% T
Drift±0.001 A/h at 500 nm
Noise±0.0005 A/h
Photometric Range0–200% T, –0.3 to 3 A, 0–9999 C
Display128 × 64 LCD
InterfaceUSB port for data export
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions460 × 380 × 180 mm
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli3
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.3 nm
Stray Light≤0.03% T
Wavelength SettingAutomatic
Photometric Range0–200% T, –0.3–3 A, 0–9999 C
Photometric Accuracy±0.5% T
Photometric Repeatability≤0.2% T
Baseline Stability±0.001 A/h at 500 nm
Display128×64 dot-matrix LCD
Data InterfaceUSB
Printer InterfaceParallel port
Light SourcesImported deuterium and tungsten lamps
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions420 × 300 × 160 mm
Weight13 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli8
Optical SystemDual-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth1.8 nm
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability≤0.15% T
Baseline Flatness±0.001 A
Drift≤0.0004 A/h (at 500 nm)
Noise≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low selectable
Data InterfaceUSB
Display320 × 240 pixel LCD
Light SourcesImported tungsten and deuterium lamps
Detector TypeImported silicon photodiode
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions625 × 430 × 210 mm
Weight28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli9
Optical SystemDual-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm @ 656.1 nm (D₂ line), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (motorized, user-selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability≤0.15% T
Baseline Flatness±0.001 A
Drift±0.0004 A/h @ 500 nm
Noise±0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3 modes)
Data InterfaceUSB
Display320 × 240 pixel LCD
Light SourcesImported deuterium and tungsten lamps
DetectorImported silicon photodiode
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions625 × 430 × 210 mm
Weight28 kg
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0