BrandHanon
OriginShandong, China
ModelN70
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform Interferometry
Wavenumber Range3750–12500 cm⁻¹
Scan Speed<1 s (at 8 cm⁻¹ resolution)
Data Sampling Intervals2, 4, 8, or 16 cm⁻¹
Measurement ModesIntegrating Sphere Diffuse Reflectance / Transflectance
Chemometrics SoftwarePLSQ — Partial Least Squares Spectral Modeling System
DetectorTEC-cooled InGaAs (2-stage thermoelectric cooling)
Resolution<2 cm⁻¹ @ 7306.74 cm⁻¹
Wavenumber Accuracy<0.1 cm⁻¹ @ 7306.74 cm⁻¹
Wavenumber Reproducibility<0.04 cm⁻¹ @ 7306.74 cm⁻¹
Inter-instrument Wavenumber Reproducibility<0.05 cm⁻¹ @ 7306.74 cm⁻¹
Absorbance Precision±0.1% T
Sample Measurement Time<30 s
Dimensions445 × 237 × 320 mm
Weight20 kg
Power Consumption60 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN500
Instrument TypePortable
PrincipleMicro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI)
Wavelength Range1750–2150 nm (extendable to 2450 nm)
DetectorInGaAs
Wavelength Resolution (FWHM)≤20 nm (≤1% of operating wavelength)
Wavelength Accuracy±1 nm
Signal-to-Noise Ratio (SNR)≥3000
Sample Measurement Time<30 s
Light Source Lifetime5000 h
Measurement ModeDiffuse Reflectance
Dimensions (L×W×H)395 × 280 × 215 mm
Weight5.5 kg
Included Computing PlatformMicrosoft Surface tablet
SoftwareMEMS Chemometrics Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN550
Instrument TypeLaboratory NIR Spectrometer
PrincipleMEMS Micro-Electro-Mechanical Systems Spectral Modulation
Wavelength Range900–1700 nm
DetectorThermoelectrically Cooled InGaAs Array (256 pixels)
Slit Width50 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.2 nm
Signal-to-Noise Ratio≥3000
Measurement Time per Sample<30 s
Sampling ModeDiffuse Reflectance
Sample Holders10 cm wide-mouth cup & 3 cm powder cup
Dimensions (L×W×H)450 × 280 × 228 mm
Weight15 kg
ComplianceASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture
Chemometrics SoftwareMEMS Quantitative Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectral Engines
OriginFinland
ModelNIRONE DEVICE
Instrument TypePortable NIR Spectrometer
Operating PrincipleMicro-Electro-Mechanical Systems (MEMS)-Based Fabry–Pérot Interferometer
Wavelength Range1150–1950 nm (standard configuration)
Spectral Acquisition Time<50 ms per spectrum
Spectral Sampling IntervalAdjustable from 1 to 10 nm
Optical Measurement ModesDiffuse Reflectance and Transmission
DetectorSingle-pixel InGaAs photodiode with integrated thermoelectric stabilization
Spectral Resolution (FWHM)15–25 nm
Wavelength Tuning Speed<1 ms per step
Tuning Step Size0.1 nm (up to 512 discrete wavelengths)
Data InterfacesBluetooth 5.0 + USB 2.0 (micro-USB)
Onboard PowerRechargeable Li-ion battery (≥8 h typical operation)
Software SuiteNIRSA Chemometrics Platform + SensorControl PC/Android/iOS Application
ComplianceCE, RoHS, FCC Part 15 Class B
Firmware ArchitectureField-upgradable via OTA or USB
Added to wishlistRemoved from wishlist 0
Add to compare
OriginFinland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNIRONE SENSOR
Instrument TypePortable
Application DomainGeneral-purpose (Universities & Research Labs)
Operating PrincipleMEMS-based Fabry–Pérot Interferometer
Wavelength Ranges1150–1350 nm (S 1.4)
Scan Speed<50 ms per spectrum
Spectral Sampling IntervalAdjustable from 1–10 nm
Measurement ModesDiffuse Reflectance & Transmission
Chemometrics SoftwareNIRSA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN110
Instrument TypePortable NIR Spectrometer
PrincipleMEMS-based Micro-Grating Monochromator with Array Detector
Wavelength Range640–1050 nm (Reflectance), 340–750 nm (Transmittance)
Optical Resolution≤20 nm (Reflectance), ≤14 nm (Transmittance)
Wavelength Repeatability±0.5 nm
Noise Level≤60 µAU
Signal-to-Noise Ratio≥7500
Operating Temperature5–40 °C
Relative Humidity<85% RH (recommended <75% RH)
Dimensions (L×W×H)179 × 126.5 × 52.6 mm
Weight215 g
Power SupplyDC 5 V / 1000 mA
Tungsten Lamp Current400 mA × 2
Sampling ModesReflectance Ratio, Transmittance
Data Acquisition IntervalConfigurable via Hanir Software
Scan SpeedUp to 10 spectra/sec (typical, dependent on integration time)
Software PlatformAndroid-based Hanir v3.x with GLP-compliant audit trail logging
Chemometrics EngineIntegrated MEMS-optimized PLS and PCA algorithms
ComplianceSupports ASTM E1655, ISO 12099, and USP <857> spectral data handling conventions