Empowering Scientific Discovery

Hanon Future Technology Group Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN70
Instrument TypeLaboratory FT-NIR Spectrometer
PrincipleFourier Transform Interferometry
Wavenumber Range3750–12500 cm⁻¹
Scan Speed<1 s (at 8 cm⁻¹ resolution)
Data Sampling Intervals2, 4, 8, or 16 cm⁻¹
Measurement ModesIntegrating Sphere Diffuse Reflectance / Transflectance
Chemometrics SoftwarePLSQ — Partial Least Squares Spectral Modeling System
DetectorTEC-cooled InGaAs (2-stage thermoelectric cooling)
Resolution<2 cm⁻¹ @ 7306.74 cm⁻¹
Wavenumber Accuracy<0.1 cm⁻¹ @ 7306.74 cm⁻¹
Wavenumber Reproducibility<0.04 cm⁻¹ @ 7306.74 cm⁻¹
Inter-instrument Wavenumber Reproducibility<0.05 cm⁻¹ @ 7306.74 cm⁻¹
Absorbance Precision±0.1% T
Sample Measurement Time<30 s
Dimensions445 × 237 × 320 mm
Weight20 kg
Power Consumption60 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli6
Optical DesignDouble-beam
Detector TypePhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm at D₂ line (656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability±0.15% T
Baseline Flatness±0.001 A
Drift≤0.001 A/h at 500 nm
Noise Level≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3-step selectable)
A/D Resolution24-bit
Display320 × 240 LCD
Light SourcesImported deuterium lamp & tungsten-halogen lamp
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions470 × 370 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN500
Instrument TypePortable
PrincipleMicro-Electro-Mechanical Systems (MEMS)-based Fabry–Pérot Interferometer (FPI)
Wavelength Range1750–2150 nm (extendable to 2450 nm)
DetectorInGaAs
Wavelength Resolution (FWHM)≤20 nm (≤1% of operating wavelength)
Wavelength Accuracy±1 nm
Signal-to-Noise Ratio (SNR)≥3000
Sample Measurement Time<30 s
Light Source Lifetime5000 h
Measurement ModeDiffuse Reflectance
Dimensions (L×W×H)395 × 280 × 215 mm
Weight5.5 kg
Included Computing PlatformMicrosoft Surface tablet
SoftwareMEMS Chemometrics Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN550
Instrument TypeLaboratory NIR Spectrometer
PrincipleMEMS Micro-Electro-Mechanical Systems Spectral Modulation
Wavelength Range900–1700 nm
DetectorThermoelectrically Cooled InGaAs Array (256 pixels)
Slit Width50 nm
Wavelength Accuracy±1 nm
Wavelength Repeatability±0.2 nm
Signal-to-Noise Ratio≥3000
Measurement Time per Sample<30 s
Sampling ModeDiffuse Reflectance
Sample Holders10 cm wide-mouth cup & 3 cm powder cup
Dimensions (L×W×H)450 × 280 × 228 mm
Weight15 kg
ComplianceASTM E1655, ISO 12099, USP <857>, GLP/GMP-ready software architecture
Chemometrics SoftwareMEMS Quantitative Analysis Suite
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli7
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm at 656.1 nm (D₂ line), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (user-selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability±0.15% T
Baseline Flatness±0.001 A
Drift≤0.001 A/h at 500 nm
Noise≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3 modes)
A/D Resolution24-bit
Display320 × 240 LCD
Light SourcesImported Tungsten and Deuterium Lamps
Detector TypeImported Silicon Photodiode
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions470 × 370 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli5
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.2 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
A/D Resolution24-bit
Baseline Flatness±0.001 A
Photometric Accuracy±0.3% T
Photometric Repeatability±0.15% T
Drift≤0.001 A/h (at 500 nm)
Noise≤0.0005 A
Photometric Range0–200% T, –0.3 to 3 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (user-selectable)
Display320 × 240 LCD
Light SourcesImported Deuterium & Tungsten Lamps
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions460 × 380 × 180 mm
Weight20 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli2
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.2 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm (selectable)
Stray Light≤0.03% T
Wavelength ScanningAutomatic
A/D Resolution24-bit
Data Storage200 measurement sets + 200 calibration curves
Baseline Flatness±0.001 A
Photometric Accuracy±0.3% T
Photometric Repeatability≤0.15% T
Drift±0.001 A/h at 500 nm
Noise±0.0005 A/h
Photometric Range0–200% T, –0.3 to 3 A, 0–9999 C
Display128 × 64 LCD
InterfaceUSB port for data export
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions460 × 380 × 180 mm
Weight15 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSpectral Engines
OriginFinland
ModelNIRONE DEVICE
Instrument TypePortable NIR Spectrometer
Operating PrincipleMicro-Electro-Mechanical Systems (MEMS)-Based Fabry–Pérot Interferometer
Wavelength Range1150–1950 nm (standard configuration)
Spectral Acquisition Time<50 ms per spectrum
Spectral Sampling IntervalAdjustable from 1 to 10 nm
Optical Measurement ModesDiffuse Reflectance and Transmission
DetectorSingle-pixel InGaAs photodiode with integrated thermoelectric stabilization
Spectral Resolution (FWHM)15–25 nm
Wavelength Tuning Speed<1 ms per step
Tuning Step Size0.1 nm (up to 512 discrete wavelengths)
Data InterfacesBluetooth 5.0 + USB 2.0 (micro-USB)
Onboard PowerRechargeable Li-ion battery (≥8 h typical operation)
Software SuiteNIRSA Chemometrics Platform + SensorControl PC/Android/iOS Application
ComplianceCE, RoHS, FCC Part 15 Class B
Firmware ArchitectureField-upgradable via OTA or USB
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli3
Optical DesignDouble-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Spectral Bandwidth0.5 / 1 / 2 / 4 / 5.0 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.3 nm
Stray Light≤0.03% T
Wavelength SettingAutomatic
Photometric Range0–200% T, –0.3–3 A, 0–9999 C
Photometric Accuracy±0.5% T
Photometric Repeatability≤0.2% T
Baseline Stability±0.001 A/h at 500 nm
Display128×64 dot-matrix LCD
Data InterfaceUSB
Printer InterfaceParallel port
Light SourcesImported deuterium and tungsten lamps
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions420 × 300 × 160 mm
Weight13 kg
Added to wishlistRemoved from wishlist 0
Add to compare
OriginFinland
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelNIRONE SENSOR
Instrument TypePortable
Application DomainGeneral-purpose (Universities & Research Labs)
Operating PrincipleMEMS-based Fabry–Pérot Interferometer
Wavelength Ranges1150–1350 nm (S 1.4)
Scan Speed<50 ms per spectrum
Spectral Sampling IntervalAdjustable from 1–10 nm
Measurement ModesDiffuse Reflectance & Transmission
Chemometrics SoftwareNIRSA
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli8
Optical SystemDual-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm (at D₂ line, 656.1 nm), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth1.8 nm
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability≤0.15% T
Baseline Flatness±0.001 A
Drift≤0.0004 A/h (at 500 nm)
Noise≤0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low selectable
Data InterfaceUSB
Display320 × 240 pixel LCD
Light SourcesImported tungsten and deuterium lamps
Detector TypeImported silicon photodiode
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions625 × 430 × 210 mm
Weight28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
Modeli9
Optical SystemDual-beam
DetectorPhotodiode Array (PDA)
Wavelength Range190–1100 nm
Wavelength Accuracy±0.1 nm @ 656.1 nm (D₂ line), ±0.3 nm across full range
Wavelength Repeatability≤0.1 nm
Spectral Bandwidth0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm (motorized, user-selectable)
Stray Light≤0.03% T
Photometric Accuracy±0.2% T
Photometric Repeatability≤0.15% T
Baseline Flatness±0.001 A
Drift±0.0004 A/h @ 500 nm
Noise±0.0005 A
Photometric Range0–200% T, –4.0 to +4.0 A, 0–9999 C
Wavelength SettingAutomatic
Scan SpeedHigh/Medium/Low (3 modes)
Data InterfaceUSB
Display320 × 240 pixel LCD
Light SourcesImported deuterium and tungsten lamps
DetectorImported silicon photodiode
Power SupplyAC 220 V/50 Hz or 110 V/60 Hz
Dimensions625 × 430 × 210 mm
Weight28 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHanon
OriginShandong, China
ModelN110
Instrument TypePortable NIR Spectrometer
PrincipleMEMS-based Micro-Grating Monochromator with Array Detector
Wavelength Range640–1050 nm (Reflectance), 340–750 nm (Transmittance)
Optical Resolution≤20 nm (Reflectance), ≤14 nm (Transmittance)
Wavelength Repeatability±0.5 nm
Noise Level≤60 µAU
Signal-to-Noise Ratio≥7500
Operating Temperature5–40 °C
Relative Humidity<85% RH (recommended <75% RH)
Dimensions (L×W×H)179 × 126.5 × 52.6 mm
Weight215 g
Power SupplyDC 5 V / 1000 mA
Tungsten Lamp Current400 mA × 2
Sampling ModesReflectance Ratio, Transmittance
Data Acquisition IntervalConfigurable via Hanir Software
Scan SpeedUp to 10 spectra/sec (typical, dependent on integration time)
Software PlatformAndroid-based Hanir v3.x with GLP-compliant audit trail logging
Chemometrics EngineIntegrated MEMS-optimized PLS and PCA algorithms
ComplianceSupports ASTM E1655, ISO 12099, and USP <857> spectral data handling conventions