| Brand | PSI (Czech Republic) |
|---|---|
| Origin | Czech Republic |
| Model | SpectraPen mini |
| Spectral Range | 340–850 nm |
| Spectral Resolution (FWHM) | 15 nm |
| Wavelength Repeatability | ±0.5 nm |
| Integration Time | 1 ms – 5 s |
| ADC Resolution | 16-bit |
| Connectivity | Bluetooth 4.2 |
| Operating System | Android 5.0+ |
| Dimensions | 50 × 70 × 28 mm |
| Weight | 60 g |
| IP Rating | Splash-resistant housing |
| Battery | 650 mAh Li-ion, USB-rechargeable |
| Operating Temperature | 5–55 °C |
| Storage Temperature | −20–70 °C |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | 410Solar |
| Measurement Principle | Integrating Sphere-Based Spectral Reflectance Metrology |
| Imaging Type | Interferometric (for spectral calibration traceability) |
| Deployment Mode | Ground-Based Field & Laboratory Use |
| Compliance | ASTM E903, ASTM C1549 |
| Spectral Range | 335–2500 nm across 7 discrete bands |
| Incident Angle | 20° from normal |
| Beam Spot Diameter | 0.250" |
| Beam Half-Angle | 3° |
| Measurement Time | 10 s per acquisition |
| Warm-up Time | 90 s (VIS-NIR tungsten source) |
| Detector | Thermopile + Si/InGaAs array architecture |
| Data Output | Total reflectance, diffuse reflectance, and 20° specular reflectance |
| Calibration | NIST-traceable gold mirror standard included |
| Operating Environment | 0–40 °C (non-condensing) |
| Storage | −25–70 °C |
| Power | Rechargeable NiMH battery pack (dual cells) |
| Weight | 2.1 kg (inclusive of batteries) |
| Interface | Touchscreen LCD with embedded PDA OS |
| Data Storage | Internal SD card |
| Probe Design | Modular, field-replaceable head |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | ET-10 |
| Measurement Principle | Directional-Hemispherical Reflectance (DHR)-based Emissivity Calculation |
| Spectral Bands | 3–5 µm and 8–12 µm |
| Incident Angle | 20° from normal |
| Sample Compatibility | Opaque materials, convex surfaces up to 6" radius, concave surfaces up to 12" radius |
| Measurement Time | ≤10 s per acquisition (7 s typical) |
| Warm-up Time | 90 s |
| IR Source | Chromel–Alumel–Cobalt alloy |
| Detector Configuration | Dual-band, simultaneous measurement |
| Display | Touch-enabled LCD PDA interface |
| Power | Rechargeable NiMH battery pack (2 units) |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage Temperature | −25–70 °C |
| Weight | 2.1 kg (including batteries) |
| Calibration | NIST-traceable gold mirror reference standard included |
| Compliance | ASTM E1933, ISO 18434-1, USP <1210>, GLP-compliant data logging |
| Brand | SurfaceOptics (SOC) |
|---|---|
| Origin | USA |
| Model | ET100 |
| Spectral Range | 1.0–21 µm |
| Measurement Geometry | Bidirectional (20° & 60° incidence) |
| Spectral Bands | Six discrete bands (1.5–2.0, 2–3, 3–4, 4–5, 5–10, 10–21 µm) |
| Accuracy | ±1.5% |
| Measurement Time | ≤10 s per full-band acquisition |
| Warm-up Time | 90 s |
| Battery Life | 2 h (rechargeable NiMH) |
| Weight | 4.7 lbs (2.13 kg) |
| Operating Temperature | 0–40 °C (non-condensing) |
| Storage Temperature | −25–70 °C |
| Detector Type | Thermopile-based broadband IR sensor array |
| Calibration Traceability | NIST-traceable standards |
| Interface | Touchscreen PDA with graphical LCD |
| Data Storage | 265 MB CompactFlash |
| Output Formats | CSV, TXT, Excel-compatible |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | LightShift |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | Avg. 25 nm |
| Spatial Resolution | 512 × 512 pixels |
| Spectral Channels | 16 simultaneous channels (or 12 spectral + 4 polarimetric) |
| Data Acquisition Rate | 28 hyperspectral cubes per second |
| Detector Type | CCD |
| Dynamic Range | 12-bit |
| Pixel Pitch | 7.4 µm (spectral) × 29.6 µm (spatial) |
| Exposure Time | 1 ms |
| F-number | f/2.7 |
| Lens Focal Length | 66 mm |
| Horizontal FOV | 6.5° |
| Weight | 3.2 kg |
| Dimensions | 17.1 × 9.5 × 28.2 cm |
| Power | 12 VDC, <12 W |
| Interface | USB 3.0 |
| Minimum System Requirements | Intel Core i7 or higher, 8 GB RAM, Windows 10, NVIDIA GeForce GTX 980 / 980 Ti / 1080 or higher GPU |
| Brand | SurfaceOptics (SOC) |
|---|---|
| Origin | USA |
| Model | 410DHR |
| Spectral Range | 0.9–1.1, 1.9–2.4, 3.0–4.0, 3.0–5.0, 4.0–5.0, 8.0–12.0 µm |
| Incident Angles | 20° and 60° from normal |
| Measurement Principle | Modified integrating sphere method (collaboratively validated with NRL and NIST) |
| Detector Count | 6 discrete IR detectors |
| Measurement Time | ≤7 s per acquisition (after 90 s IR source warm-up) |
| Sample Geometry Support | Flat, convex (≥6" radius), concave (≥12" radius) |
| Operating Environment | 0–40 °C, non-condensing |
| Storage Temperature | −25 to 70 °C |
| Power | Rechargeable NiMH battery pack (dual cells) |
| Weight | 2.1 kg (with batteries) |
| Calibration | NIST-traceable gold mirror reference standard included |
| Compliance | Designed for field-deployable radiometric measurement in accordance with ASTM E903, ISO 9050, and MIL-STD-461G optical testing protocols |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC 730VS |
| Operating Principle | Push-broom |
| Imaging Modality | 3D hyperspectral datacube acquisition |
| Deployment | Ground-based and airborne compatible |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2 nm |
| Spatial Resolution (IFOV) | 0.17 mrad |
| Field of View (TFOV) | 10° |
| Detector Array | 1024 × 1024 pixels |
| Frame Rate | 15 fps |
| Bit Depth | 12-bit |
| Optical f-number | f/2.4 |
| Smile Distortion | <1.5 µm |
| Interface | Camera Link |
| Power Supply | AC / 12 V DC |
| Tripod Mount | 3/8″–16 |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC 750MW |
| Spectral Range | 2–5 µm |
| Detector Type | InSb Focal Plane Array (FPA) |
| Spatial Resolution | 256 × 240 or 512 × 512 pixels |
| Spectral Channels | 42 or 64 |
| Spectral Bandwidth | 48–73 nm |
| Frame Rate | up to 27 cubes/s |
| Instantaneous Field of View (IFOV) | 0.4–0.6 mrad @ 50 mm lens |
| Detector Pixel Pitch | 20–30 µm |
| Full-Well Capacity | 5–20 Me⁻ |
| Operating Temperature Range (for target emission) | up to 1250 °C |
| Software | HSAnalysis3 with real-time processing engine |
| Data Output Format | Standard ENVI-compatible .hdr/.dat, supports third-party analysis (MATLAB, Python, IDL) |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC710 SWIR |
| Spectral Range | 900–1700 nm |
| Spectral Resolution | 2.75 nm |
| Spatial Pixels | 640 × 568 |
| Spectral Bands | 288 |
| Digital Resolution | 14 bit |
| F-number | f/2.0 |
| Scan Method | Internal Translation-Based Pushbroom |
| Scan Rate | 60–120 lines/sec |
| Acquisition Time per Cube | ~10 s |
| Lens Options | 8 mm, 12.5 mm, 16 mm, 25 mm, 35 mm, 50 mm |
| Interface | USB |
| Power Supply | DC 12 V / AC 220 V |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC730VS |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | 2 nm |
| Spatial Resolution | 1024 × 1024 pixels |
| Smile Error | <1.5 µm |
| f-number | f/2.4 |
| Total Field of View (35 mm lens) | 10° |
| Instantaneous Field of View (35 mm lens) | 0.17 mrad |
| Frame Rate | 15 fps |
| Digitization | 12-bit |
| Interface | Camera Link |
| Scan Mechanism | Integrated push-broom scanner |
| Power Supply | AC / 12 V DC |
| Tripod Mount | 3/8″–16 |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC750 |
| Pricing | Upon Request |
| Spectral Range | 2–5 µm |
| Spectral Resolution | 48–97 nm |
| Frame Rate | Up to 15 hyperspectral cubes/s |
| Spatial Resolution Options | 256×240, 256×256, or 512×512 pixels |
| Bit Depth | 14-bit |
| Data Cube Size | 5.25 MB (HB), 4 MB (HS), 32 MB (HR) |
| Software | HSAnalysis3 v3.x |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SOC750 |
| Pricing | Upon Request |
| Spectral Range | 2–5 µm |
| Spectral Resolution | 48–97 nm |
| Spatial Resolution Options | 256×240, 256×256, 512×512 pixels |
| Data Rate | Up to 15 hyperspectral cubes/sec |
| Bit Depth | 14-bit |
| Hyperspectral Cube Size | 5.25 MB to 32 MB |
| Software | HSAnalysis3 v4.x (GUI-based, real-time processing) |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC750MW |
| Operating Principle | Push-broom |
| Imaging Mode | 3D (hyperspectral data cube) |
| Platform | Ground-based |
| Spectral Range | 2–5 µm |
| Spectral Resolution | 48–73 nm |
| Instantaneous Field of View (IFOV) | 256 × 240 pixels |
| Frame Rate | 27 cubes/s |
| Detector Type | HgCdTe (MCT) or InSb focal plane array |
| Software | HSAnalysis3 (real-time processing, GUI-based calibration & analysis) |
| Brand | SurfaceOptics |
|---|---|
| Origin | USA |
| Model | SOC760 |
| Configuration | Ground-based, Portable |
| Spectral Range | 400–1000 nm & 1000–2500 nm |
| Spectral Resolution | 2.5 nm (VIS-NIR), 5 nm (SWIR) |
| Total Spectral Bands | 650 |
| Spatial Resolution (IFOV) | 650 × 2048 pixels |
| Field of View (TFOV) | 12.5° |
| Scanning Mechanism | Oscillating mirror pushbroom |
| Detector | Uncooled CMOS (VIS-NIR), Cooled InSb FPA (SWIR) |
| Data Acquisition Platform | Integrated laptop workstation with high-end GPU, multi-core CPU, and 2 TB SSD |
| Software | Custom GUI for radiometric calibration, geometric correction, and real-time data streaming |
| Compliance | Designed for ASTM E131, ISO 18359, and USP <857> spectral data integrity requirements |
| Recommended Post-Processing | ENVI, MATLAB, Python (scikit-learn, hylite) |
| Brand | Swamp Optics |
|---|---|
| Origin | USA |
| Model | Grenouille 8-20-USB |
| Spectral Range | 50–400 nm |
| Spectral Resolution | 0.7 nm |
| Spatial Resolution | 480 × 640 pixels |
| Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.01 rad |
| Frame Rate | 330 fs |
| Imaging Modality | 3D |
| Operating Mode | Airborne-mounted |
| Compliance | ASTM E2912, ISO/IEC 17025-compatible data acquisition architecture |
| Origin | Finland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UV4E-UV |
| Pricing | Available Upon Request |
| Spectral Range | 200–400 nm |
| Spectral Resolution | 2 nm |
| Effective Slit Length | 9.3 mm |
| Optical Throughput | >50% |
| Relative Aperture | f/2.8 |
| Slit Width | 50 µm |
| Stray Light Level | 0.5% |
| Spectral Band Count | >100 |
| CCD Sensor | 1000 × 1000 pixels |
| A/D Conversion | 12-bit |
| Dynamic Range | 59 dB |
| Full-Frame Frame Rate | >30 fps |
| Binned Frame Rate | 150 fps |
| Interface | Camera Link |
| Lens Mount | C-Mount |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | XG5000 |
| Pricing | Upon Request |
| X-ray Tube | Sealed microfocus, integrated high-voltage supply |
| Max. Tube Voltage | 90 kV |
| Max. Tube Current | 200 µA (software-limited to 89 µA) |
| Cooling | Forced air |
| Geometric Magnification | 12×–48× |
| Detectable Feature Size | ≥5 µm |
| X-Y-Z Travel Range | 400 mm × 450 mm × 150 mm |
| Image Intensifier FOV | 2″ / 4″ selectable |
| Resolution | 75–110 lp/cm |
| Radiation Leakage | ≤1 µSv/hr at 5 cm from enclosure |
| Operating Temp. | 22 ± 3 °C |
| Power Supply | AC 250 V, 10 A |
| System Weight | ~760 kg |
| Compliance | Meets IEC 61331-1, IEC 62495, and GBZ 138–2019 radiation safety requirements |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaArtScanner |
| Pricing | Available Upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | GaiaChem |
| Pricing | Upon Request |
| Operating Mode | Push-broom Scanning |
| Spectral Range (nm) | 900–1700 (NIR) / 970–2500 (SWIR) |
| Spectral Resolution (nm) | 6 (NIR) / 10 (SWIR) |
| Spectral Bands | 256 |
| Spatial Pixels per Line | 320 |
| Spatial Resolution (µm) | 30–300 |
| Scan Range (mm) | 10–100 |
| Max Sample Dimensions (mm) | 100 × 100 × 40 (W × L × T) |
| Max Scan Speed | 100 hyperspectral line images/s |
| Typical Acquisition Time | 3–10 s (320 × 320 spatial pixels, 256 bands) |
| Illumination Source | SPECIM Diffused Line Illumination Unit |
| Data Format | BIL (Band Interleaved by Line), ENVI & Evince Compatible |
| Spectral Calibration | Factory-performed |
| Reflectance Intensity Calibration | Auto-compensated per scan using internal reference tile |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GaiaField Pro-N17E Lite |
| Operating Principle | Push-broom Scanning |
| Imaging Mode | 3D Spatial-Spectral Cube Acquisition |
| Deployment Flexibility | Ground-based and Airborne Compatible |
| Spectral Range | 960–1640 nm |
| Spectral Resolution | 5 nm (FWHM) |
| Numerical Aperture | f/2.0 |
| Slit Dimensions | 30 µm × 14.2 mm |
| Detector | InGaAs |
| Spatial × Spectral Pixels | 256 × 320 |
| Spectral Bands | 320 (standard), 160 (binning mode) |
| Dynamic Range | 12-bit |
| Field of View (TFOV) | 12.2° (@ 30 mm lens) |
| Image Spatial Resolution | 256 × 400 pixels per cube |
| Scan Speed | 4 s/cube |
| Weight | 7.5 kg |
| Integrated Battery | 120 Wh (operational duration > 2 h) |
| Connectivity | Wi-Fi (Android/iOS remote control), optional serial RF link for long-range telemetry |
| Data Format | ENVI-compatible BIL/BIP, supports Evince, ENVI, SpecSight, and MATLAB workflows |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaField-V10E |
| Spectral Range | 400–1000 nm |
| Spectral Resolution | <3 nm |
| Spatial Resolution (IFOV) | <0.1° |
| Field of View (TFOV) | 20° |
| Image Resolution | 1392 × 1040 pixels |
| Frame Rate | 25–120 fps |
| Scanning Mechanism | Optomechanical Push-broom with Motorized Horizontal Scan (±22.5°, 45° total) |
| Detector Type | Uncooled CCD |
| Pixel Size | 6.45 × 6.45 µm |
| A/D Depth | 14-bit |
| Dynamic Range | 60 dB |
| Optical Interface | C-Mount |
| Lens Focal Length | 25 mm |
| f-number | F/2.4 (spectrometer), F/1.4–F/17 (lens) |
| Total Optical Throughput | >50% |
| Stray Light | <0.5% |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| System Weight | 8 kg |
| Form Factor | Hand-carried integrated unit |
| Data Output Format | Standard raw binary cube (.raw) compatible with ENVI, Specim IQ, and MATLAB |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | GaiaMicroscope |
| Pricing | Available upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer | ZOLIX Optics |
| Type | GaiaSorter |
| Spectral Range | 350–2500 nm |
| Spectral Resolution | 2.8 nm (at VNIR band) |
| Spatial Resolution (IFOV) | 30 µm / 50 µm |
| Imaging Resolution | 1392 × 1040 pixels |
| Field of View (TFOV) | 20° |
| Frame Rate | 25–120 fps |
| Imaging Mode | Push-broom Hyperspectral Scanning |
| Deployment | Ground-based & Airborne Compatible |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments and industrial QA/QC workflows |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | GaiaTracer |
| Pricing | Available upon Request |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | HyperSIS |
| Pricing | Available Upon Request |
| Spectral Range Options | 400–1000 nm (VNIR), 900–1700 nm (NIR), 1000–2500 nm (SWIR) |
| Max Frame Rate | Up to 100 images/s |
| Sample Dimension Limit | ≤200 mm × 200 mm × 100 mm |
| Scanning Mechanism | Push-broom (line-scan) with motorized X-stage |
| Brand | ZOLIX |
|---|---|
| Origin | Finland |
| Manufacturer | Specim, Oy (distributed by ZOLIX) |
| Type | Imported Hyperspectral Imager |
| Model Range | UV/HS/QE/PFH/NIR / Image-λ V8/V10/N17E/N25E |
| Spectral Range | 380–2500 nm |
| Spectral Resolution | 2–10 nm |
| Detector Types | CCD, Cooled CCD, CMOS, InGaAs, MCT |
| Spatial Resolution | Up to 1600 × 1200 pixels |
| Frame Rate | 11–180 fps |
| Interface | Ethernet, USB, Camera Link (CL), FireWire (FW), LVDS |
| Brand | ZOLIX |
|---|---|
| Model | iTracer |
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Operating Principle | Whiskbroom Scanning |
| Imaging Modality | 3D Hyperspectral Cubes |
| Deployment Flexibility | Ground-based and Airborne Compatible |
| Spectral Ranges | 200–400 nm, 380–800 nm, 400–1000 nm, 900–1700 nm, 1000–2500 nm |
| Spectral Resolution | 0.01 nm |
| Spatial Resolution | 1280 × 1024 pixels |
| Total Field of View (TFOV) | 5° |
| Instantaneous Field of View (IFOV) | 0.1 mrad |
| Frame Rate | 5 fps |
| Brand | ZOLIX |
|---|---|
| Model | LIF&PLIF |
| Origin | Beijing, China |
| Type | Modular, turnkey PLIF/LIF combustion diagnostic platform |
| Laser Tuning Range | 220–780 nm (extendable to 200–4500 nm) |
| Spectral Linewidth | ≤0.06 cm⁻¹ |
| Pulse Energy | 110 mJ @ 560 nm |
| Repetition Rate | 10 Hz |
| Laser Sheet Thickness | 0.1–0.3 mm |
| Temporal Synchronization Precision | ±5 ps |
| ICCD Optical Gate Width | <2 ns (true optical) |
| Delay Range | 0–2000 s |
| Delay Channels | 4 (expandable to 8) |
| Detector Options | iStar Gen II/III ICCD or iStar sCMOS (2560×2160, USB3.0, 50 fps full-frame) |
| Software | Integrated acquisition, time-resolved image processing, quantitative species concentration & temperature field reconstruction, multi-species LIF analysis (OH, CO, CH, NO, fuel tracers), PIV-compatible timing architecture |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Omni-Imager |
| Price Range | USD 70,000 – 140,000 |
| Operating Principle | Push-broom scanning |
| Imaging Method | Filter-based |
| Deployment Mode | Ground-based and airborne compatible |
| Spectral Resolution | 2.8 nm @ 30 µm slit, 2 nm @ 18 µm slit |
| Detector Types | CCD (1392×1040), sCMOS (2048×2048), EMCCD (512×512), InGaAs (320×256 / 640×512) |
| Spectral Ranges | 400–1000 nm (Vis-NIR), 900–1700 nm (NIR) |
| Numerical Aperture | f/2.4 (Vis-NIR), f/2.0 (NIR) |
| Slit Dimensions | 30 µm × 14.2 mm (standard), 18 µm × 14.2 mm (optional) |
| Data Depth | 12-bit / 16-bit |
| Interface | USB 2.0 / USB 3.0 |
| Lens Mount | C-mount |
| Cooling | Air-cooled to −0 °C (CCD/sCMOS), TE-cooled to −80 °C (EMCCD), TE3-cooled (InGaAs) |
| Software | Proprietary acquisition & analysis suite with ENVI/Evince/SpecSight export compatibility |
| Optional Onboard Processing | Intel Core i7, 16 GB RAM, 256 GB SSD |
| Brand | ZOLIX |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | Thomson Scattering Spectroscopic Diagnostic System |
| Pricing | Upon Request |