- All
- Favorite
- Popular
- Most rated
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Miniature Low-Speed Benchtop Centrifuge |
| Model | IKA mini G |
| Maximum Speed | 6000 rpm |
| Maximum RCF | 2000 × g |
| Maximum Capacity | 8 × 2.0 mL |
| Timer Range | 1–99 min (digital LED display) |
| Dimensions (W × D × H) | 155 × 175 × 105 mm |
| Weight | 1.4 kg |
| Power Supply | 24 V DC |
| Motor Input/Output Power | 12 W / 8 W |
| Safety Rating | DIN EN 60529 IP30 |
| Operating Ambient Temperature | 5–40 °C |
| Relative Humidity Limit | ≤80% |
| Rotor Exchange | Tool-Free |
| Quick-Stop Function | Yes |
| Lid Interlock | Active (operation only with lid closed) |
| Noise Level | <45 dB(A) |
| Rotor Type | Fixed-angle, universal for 0.2–2.0 mL tubes |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Magnetic Stirrer with Integrated Heating Plate |
| Model | RCT classic |
| Maximum Stirring Volume | 20 L (H₂O) |
| Speed Range | 50–1500 rpm |
| Heating Temperature Range | Ambient +盘面自热 up to 310 °C |
| External Temperature Sensor Interface | PT1000, ETS-D5, ETS-D6 |
| Safety Features | Error 5 detection (dry-run protection), adjustable safety cutoff (50–360 °C), IP42 rating, DIN EN 61010-2-010 compliance |
| Connectivity | RS232 and USB interfaces |
| Display | Dual LED (set/actual speed & temperature) |
| Power Input | 220–230 V, 50/60 Hz, 650 W max |
| Dimensions | 160 × 85 × 270 mm |
| Weight | 2.4 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | ICC control |
| Temperature Range | 10–150 °C |
| Temperature Stability | ±0.01 K |
| Heating Power | 2000 W |
| Pump Type | Dual-mode pressure/suction pump |
| Circulation Mode | Internal and external circulation |
| Programmable Control | 10 programs × 10 segments |
| Display | Color TFT screen |
| Safety Features | Dual PT100/PT1000 temperature sensors, adjustable safety cutoff (0–160 °C), visual & audible alarms, overpressure protection, secondary safety circuit |
| Compliance | DIN 12876 Class III, DIN EN 60529 IP21, CE |
| Interface | RS232, USB |
| Dimensions (W×D×H) | 145 × 340 × 200 mm |
| Weight | 3.75 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Input Voltage | 230/115 V, 50/60 Hz |
| Max. Input Power | 2100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Probe-type Rotational Homogenizer |
| Model | T 25 digital ULTRA-TURRAX® |
| Dimensions (W×D×H) | 87 × 271 × 106 mm |
| Volume Range | 1–2000 mL (H₂O) |
| Motor Input Power | 800 W |
| Motor Output Power | 500 W |
| Speed Range | 3000–25,000 rpm |
| Speed Accuracy | ±1 % |
| Speed Display | LED |
| Speed Control | Continuous (Stepless) |
| Max. Viscosity | 5000 mPa·s |
| Noise Level (without dispersing tool) | 75 dB(A) |
| Shaft Diameter | 13 mm |
| Shaft Length | 160 mm |
| IP Rating | IP20 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % |
| Voltage | 220–240 V |
| Frequency | 50/60 Hz |
| Weight | 2.5 kg |
| Duty Cycle | 100 % continuous operation |
| Compliance | DIN EN 60529 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Import |
| Model | HABITAT cell |
| Vessel Material | Borosilicate Glass |
| Working Volume Range | 0.5–10 L (configurable via vessel options) |
| Gas Control | 4-channel MFCs (Air, O₂, N₂, CO₂) |
| Flow Range | 0–2000 cc/min per channel |
| Peristaltic Pumps | 4 × Watson Marlow 114DV heads |
| Stirring Speed | 1–2200 rpm |
| Temperature Control | Heating blanket (250 W) or external thermostat interface |
| pH Range | 0–14 |
| Accuracy | ±0.02 pH |
| DO Range | 0–200 %sat |
| Resolution | 0.01 %sat |
| Accuracy | ±0.3 %sat |
| Temp Control Range | 5–60 °C (heating blanket) |
| Data Storage | 32 GB internal SSD |
| Compliance Options | FDA 21 CFR Part 11–compliant software module available |
| Enclosure Rating | IP20 |
| Power Input | 100–240 V, 50/60 Hz |
| Max Power Consumption | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Modular Benchtop Reactor System |
| Model | LR-2.ST the Versatile |
| Vessel Capacity | 2 L (500–2000 mL usable volume) |
| Operating Pressure Range | Up to 6 bar (gauge), down to 25 mbar absolute vacuum |
| Temperature Range | Ambient to +230 °C |
| Speed Range | 8–290 rpm |
| Max. Torque | 100 N·cm |
| Max. Viscosity Handling | 70,000 mPa·s |
| Drive Motor | EUROSTAR 100 control-type stirrer with bidirectional rotation |
| Sealing Material in Contact | FFPM (perfluoroelastomer), PTFE, borosilicate glass 3.3, stainless steel 1.4571 (AISI 316Ti) |
| Port Configuration | 3 × NS 29/32, 2 × NS 14/23 |
| Vertical Travel of Lift Stand | 390 mm |
| Dimensions (W × H × D) | 460 × 1240 × 430 mm |
| Weight | 34 kg |
| Power Supply | 115 V, 50/60 Hz |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH (non-condensing) |
| Control Interface | Removable WiCo wireless controller with real-time torque trend display and microprocessor-based speed regulation |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Imported Laboratory Equipment |
| Model | RV 10 auto V Starter Solution |
| Evaporation Flask Capacity | 3 L |
| Ultimate Vacuum | 9 mbar |
| Rotation Speed Range | 5–300 rpm |
| Heating Bath Temperature Range | Ambient to 180 °C |
| Temperature Control Accuracy | ±1 K |
| Condenser Cooling Area | 500 cm² (base unit) |
| Heating Bath Volume | 4 L |
| Heating Power | 1350 W |
| Motorized Lift Travel | 140 mm |
| Interface | RS232, Micro-USB, Analog Output |
| Compliance | DIN EN 60529 IP20, CE, RoHS |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | RV 10 auto pro |
| Capacity | 3 L |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 20–280 rpm |
| Temperature Control Range | Ambient to 180 °C |
| Heating Accuracy | ±1 °C |
| Condenser Surface Area | 1500 cm² |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Product Type | Digital Overhead Stirrer |
| Model | EUROSTAR 20 digital |
| Max. Mixing Volume (H₂O) | 25 L |
| Speed Range | 0/30–2000 rpm |
| Max. Viscosity | 10,000 mPa·s |
| Max. Torque | 40 N·cm (at 30–600 rpm), 20 N·cm (at 600–2000 rpm) |
| Torque Measurement Accuracy | ±6 N·cm |
| Speed Setting Accuracy | ±1 rpm |
| Speed Display | LCD |
| Interfaces | USB-C, RS232 |
| IP Rating | IP54 |
| Motor Type | Brushless DC |
| Continuous Duty Cycle | 100% |
| Dimensions (W×H×D) | 89 × 237 × 191 mm |
| Weight | 3.8 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Compliance | ISO Class 7/8 Cleanroom Certified, DIN EN 60529 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | ICC control pro 20 c |
| Instrument Type | Constant-Temperature Bath Circulator |
| Circulation Mode | Internal & External Circulation |
| Temperature Control | Heating-Only |
| Bath Volume | 18 L |
| Temperature Range | Ambient +10 °C to 150 °C |
| Temperature Stability | ±0.01 °C |
| Input Power | 2100 W |
| Supply Voltage | 230 V AC, 50/60 Hz |
| Pump Flow Rate (max) | 18 L/min at 0 bar backpressure |
| Max Pressure Output | 0.3 bar |
| Max Suction Pressure | 0.2 bar |
| Bath Opening Dimensions | 255 × 309 mm (standard), up to 292 × 325 mm (with optional large cover) |
| Immersion Depth Range | 85–125 mm |
| Bath Bottom Flat Surface Area | Compatible with standard lab plates |
| Protection Rating | IP21 per DIN EN 60529 |
| Safety Compliance | DIN 12876 Class III, FL-marked |
| Sensor Configuration | Dual PT100 (control) + PT1000 (safety cutoff) |
| Display | TFT touchscreen with dual temperature readout (working & safety setpoints) |
| Alarm System | Visual (LED) and audible alerts for temperature deviation, sensor failure, dry-run, and overtemperature |
| Programmable Safety Limit | 0–160 °C |
| Calibration Support | Traceable calibration options available per ISO/IEC 17025 guidelines |
| Interface | RS232 and USB for remote monitoring and data logging |
| Operating Environment | 5–40 °C ambient, ≤80% RH non-condensing |
| Continuous Duty Rating | 100% |
| Dimensions (circulator unit only) | 145 × 340 × 200 mm |
| Weight | 3.75 kg |
| Enclosure Material | Stainless steel housing with chemical-resistant coating |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | ICC basic eco 18 c |
| Instrument Category | Compact Immersion Circulator (DIN 12876 Class III) |
| Bath Volume | 18 L |
| Temperature Range | 10–150 °C |
| Temperature Stability | ±0.02 K |
| Heating Power | 2100 W |
| Supply Voltage | 230 V AC, 50/60 Hz |
| Pump Flow Rate | up to 18 L/min (0 bar backpressure) |
| Max. Pressure | 0.3 bar |
| Max. Suction Head | 0.2 bar |
| External Sensor Input | Yes |
| Display Resolution | 0.1 K |
| Safety Cut-off Range | 0–160 °C |
| Protection Rating | IP21 |
| Interface | RS232, USB |
| Dimensions (Unit) | 145 × 340 × 200 mm |
| Weight | 3.75 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Model | Matrix Delta Plus |
| Temperature Range | –30 °C to +110 °C |
| Temperature Accuracy | ±1 °C (at setpoint) |
| Temperature Stability | ±0.5 °C |
| Temperature Homogeneity | ±0.5 °C (within block) |
| Heating Rate | 5.5 °C/min (max) |
| Cooling Rate | 2 °C/min (from ambient down to –30 °C) |
| Max Load Capacity | 0.3 kg |
| Timer Range | 1 s – 6000 min |
| Display | TFT LCD |
| Programmable Ramp Rates | Yes |
| Heating Power | 100 W |
| Cooling Power | 72 W |
| Integrated Peltier Cooling | Yes |
| Interchangeable Modules | Up to 10 standard configurations |
| Safety Cut-off | 145 °C |
| Dimensions (W × D × H) | 216 × 127 × 351 mm |
| Net Weight | 9.5 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Ingress Protection | IP21 |
| Interfaces | RS232, USB |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Max Input Power | 230 W |
| Operating Modes | Timer, Continuous, Program |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Equipment |
| Model | T 18 mini digital Solution |
| Price | Upon Request |
| Motor Input Power | 210 W |
| Motor Output Power | 160 W |
| Volume Capacity (H₂O) | 0.001–1.5 L |
| Max. Viscosity | 2000 mPa·s |
| Speed Range | 3000–25,000 rpm |
| Speed Accuracy | ±3 % |
| Speed Control | Continuous (Stepless) |
| Speed Display | TFT LCD |
| Timer Function | Yes (LED display) |
| Continuous Duty Cycle | 100 % |
| Noise Level (no dispersing tool) | 75 dB(A) |
| Motor Type | Brushless DC Motor |
| Extension Arm Diameter | 13 mm |
| Extension Arm Length | 160 mm |
| Process Mode | Batch |
| IP Rating | IP30 (per DIN EN 60529) |
| USB Interface | USB-C |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Standby Power Consumption | 3 W |
| DC Supply | 48 V =, 4500 mA |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % RH (non-condensing) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | STARVISC 200-2.5 control |
| Max. Stirring Volume (H₂O) | 100 L |
| Motor Input Power | 130 W |
| Motor Output Power | 84 W |
| Drive Type | Brushless DC Motor |
| Speed Range I (50/60 Hz) | 6–400 rpm |
| Speed Range II (50/60 Hz) | 30–2000 rpm |
| Speed Control | Continuously Variable |
| Speed Accuracy | ±1 rpm (n > 300 rpm) |
| Speed Measurement Deviation | ±1% (n > 300 rpm) |
| Max. Torque Range I | 200 N·cm |
| Max. Torque Range II | 40 N·cm |
| Torque Measurement Deviation | ±2.5 N·cm |
| Viscosity Range | Up to 100,000 mPa·s |
| Temperature Measurement | PT1000 sensor (DIN IEC 751 Class A), -10 to +350 °C, accuracy ±0.5 K |
| Temp. Resolution | 0.1 K |
| Housing | Cast aluminum with thermoplastic polymer coating |
| IP Rating | IP40 |
| Dimensions (W×H×D) | 91 × 395 × 231 mm |
| Weight | 5.9 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH |
| Interfaces | RS232, USB |
| Remote Control Range | Up to 150 m (line-of-sight dependent) |
| Continuous Duty Cycle | 100% |
| Hollow Shaft Diameter | 10.3 mm |
| Clamp Jaw Range | 0.5–10 mm |
| Extension Arm | Ø16 mm × 220 mm |
| Timer Range | 1–6000 min |
| Certifications | DIN EN 60529, CE-compliant |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | RC 2 lite |
| Instrument Type | Circulating Chiller |
| Circulation Mode | Internal & External |
| Temperature Control | Refrigeration & Heating Capable |
| Bath Volume | 1–3.5 L |
| Temperature Range | –10 °C to Ambient (up to +70 °C with external heater) |
| Temperature Stability | ±0.5 K |
| Input Power | 250 W |
| Supply Voltage | 230 V AC, 50/60 Hz |
| Refrigerant | R290 (Propane), 70 g |
| Max. Cooling Capacity | 400 W @ 20 °C |
| Pump Flow Rate | 18 L/min @ 0 bar |
| Max. Pressure | 0.35 bar (pressure side), 0.15 bar (suction side) |
| Protection Rating | IP21 |
| Compliance | DIN 12876 Class I, DIN EN 60529, CE |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | EasySyn 500 Advanced |
| Vessel Capacity | 0.5 L |
| Vessel Material | Borosilicate Glass 3.3 |
| Operating Temperature Range | −50 °C to 200 °C |
| Maximum Vacuum | 3 mbar |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Stirrer | EUROSTAR 100 control (100 N·cm max torque) |
| Interface | RS232, USB |
| Compliance | CE, ISO 9001, GLP-supporting architecture |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Digital Heating Magnetic Stirrer |
| Max. Stirring Volume (Water) | 15 L |
| Speed Range | 100–2000 rpm |
| Speed Setting Resolution | ±50 rpm |
| Heating Temperature Range | 50–320 °C |
| Safety Overtemperature Limit | 100–360 °C |
| Heating Power Output | 600 W |
| Plate Material | Stainless Steel 1.4301 with Copper Sublayer |
| Plate Diameter | Ø 135 mm |
| Heating Rate (1 L water in H1500 vessel) | 6 K/min |
| Display | LED |
| External Temperature Sensor Interface | ETS-D5 compatible |
| Ingress Protection Rating | IP21 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | ICC 150 lite pro 20 |
| Instrument Type | Constant-Temperature Bath Circulator |
| Circulation Mode | Internal & External Circulation |
| Temperature Control | Heating-Only |
| Bath Volume Capacity | 20 L |
| Temperature Range | Ambient to 150 °C |
| Temperature Stability | ±0.05 K |
| Input Power | 2100 W |
| Supply Voltage | 230 V AC, 50/60 Hz |
| Pump Flow Rate (at 0 bar backpressure) | 15 L/min |
| Max. Pressure (no-flow) | 0.3 bar |
| Max. Suction Pressure (no-flow) | 0.1 bar |
| Minimum Bath Depth | 150 mm |
| Dimensions (W × H × D) | 135 × 303 × 180 mm |
| Weight | 4.7 kg |
| IP Rating | IP21 |
| Safety Compliance | DIN 12876 Class III, DIN EN 60529, Overpressure & Overtemperature Protection |
| Sensor Type | Dual PT1000 (Working + Safety), PID Control |
| Display | LED, Resolution 0.1 K |
| Alarm System | Visual (LED) and Audible |
| Interface | RS232, USB-B |
| Continuous Duty Rating | 100% |
| Operating Ambient | 5–40 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Digital Overhead Stirrer |
| Model | MINISTAR 80 digital |
| Max. Mixing Volume (H₂O) | 50 L |
| Speed Range | 0/50–500 rpm |
| Max. Torque | 80 N·cm |
| Motor Type | Brushless DC Motor |
| Power Input | 69 W |
| Dimensions (W×H×D) | 70 × 193 × 147 mm |
| Weight | 1.72 kg |
| IP Rating | IP54 |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤80 % |
| USB Interface | Yes |
| Voltage | 100–240 V AC, 50/60 Hz |
| Max. Viscosity | 60,000 mPa·s |
| Shaft Clamp Range | 0.5–8 mm |
| Hollow Shaft ID | 8.5 mm |
| Extension Arm Diameter | 13 mm |
| Extension Arm Length | 160 mm |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Werke GmbH & Co. KG |
| Type | Magnetic Stirrer |
| Model | RO 5 |
| Number of Stirring Positions | 5 |
| Position Spacing | 90 mm |
| Max. Stirring Volume (H₂O) | 0.4 L |
| Speed Range | 0–1200 rpm |
| Speed Resolution | 10 rpm steps |
| Speed Deviation per Position | 0 % |
| Stir Bar Length Compatibility | 25–30 mm |
| Plate Material | Stainless Steel 1.4301 |
| Plate Dimensions | 120 × 470 mm |
| Device Dimensions (W × H × D) | 120 × 60 × 570 mm |
| Weight | 3.66 kg |
| Ambient Temperature Range | 5–40 °C |
| Relative Humidity Limit | ≤80 % (non-condensing) |
| Ingress Protection | IP40 per DIN EN 60529 |
| Input Voltage | 100–240 V AC, 50/60 Hz |
| Power Consumption | 13 W |
| DC Supply | 24 V =, 500 mA |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Type | Heating Magnetic Stirrer |
| Model | RT 10 |
| Maximum Stirring Volume per Position | 4 L |
| Speed Range | 0–1000 rpm |
| Temperature Control Range | Ambient to 120 °C |
| Heating Power | 375 W |
| Plate Material | Anodized Aluminum |
| Dimensions (W × H × D) | 190 × 60 × 610 mm |
| Weight | 7.5 kg |
| IP Rating | IP40 |
| Power Supply | 230 / 115 / 100 V, 50/60 Hz |
| Safety Temperature Limit | Adjustable from 50 to 150 °C |
| Heating Rate | ~3 K/min |
| Stirring Points | 10 (90 mm spacing) |
| Speed Resolution | 10 rpm increments |
| Minimum Stir Bar Length | 25 mm |
| Maximum Stir Bar Length | 30 mm |
| Operating Environment | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | RV 10 digital V |
| Capacity | 3 L |
| Ultimate Vacuum | 1 mbar |
| Rotation Speed | 20–280 rpm |
| Temperature Control Range | Ambient to 180 °C |
| Temperature Accuracy | ±1 K |
| Condenser Surface Area | 1500 cm² |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Model | C-MAG HS 7 |
| Instrument Type | Magnetic Stirrer |
| Max. Stirring Volume (H₂O) | 10 L |
| Speed Range | 100–1500 rpm |
| Heating Temperature Range | 50–500 °C |
| Heating Power | 1000 W |
| Plate Material | Ceramic |
| Plate Dimensions | 180 × 180 mm |
| Safety Cut-off | 550 °C |
| External Temperature Sensor Interface | ETS-D5 |
| IP Rating | IP21 |
| Input Voltage | 230 / 120 / 100 V, 50/60 Hz |
| Power Consumption | 1020 W |
| Weight | 5 kg |
| Operating Ambient | 5–40 °C, ≤80 % RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Model | A10 Basic |
| Instrument Type | Batch Grinder |
| Sample Type | Soft, brittle, fibrous, and elastic materials |
| Maximum Feed Size | < 6 mm |
| Final Particle Size | < 40 µm (typical), down to ≤10 µm under optimized conditions |
| Batch Capacity | Up to 50 mL |
| Grinding Mechanism | High-speed shear and impact |
| Motor Output Power | 240 W |
| Input Power | 300 W |
| Max. Speed | 25,000 rpm (±500 rpm) |
| Peripheral Speed | 73 m/s |
| Grinding Chamber Material | Stainless Steel 1.4301 |
| Cutting Tool Material | Stainless Steel 1.4034 |
| Cooling Options | Integrated water-cooling jacket + optional dry-ice cooling |
| Duty Cycle | 5 min ON / 10 min OFF |
| Dimensions (W × H × D) | 130 × 250 × 145 mm |
| Weight | 3.13 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Protection Class | IP41 (DIN EN 60529) |
| Electrical Supply | 220–240 V, 50/60 Hz |
| Compliance | CE, RoHS, IEC 61000-6-3/-4 |
Show next