- All
- Favorite
- Popular
- Most rated
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Type | Integrated Control Tower Fermenter System |
| Vessel Capacity | 0.5–10 L |
| Aeration | Four Independent Mass Flow Controlled Gas Lines (Air, O2, N2, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200 % saturation |
| Accuracy | ±0.3 % sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing Mode + Standard Profile/Cascade Modes |
| Speed Range | 1–2200 rpm |
| Reversibility | Yes |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (Acid, Base, Antifoam, Feed) |
| Flow Range | 1–270 mL/min |
| Data Management | 32 GB internal storage, Ethernet, USB, RS232, Wi-Fi, FDA 21 CFR Part 11-compliant software option available |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Benchtop Bioreactor with Integrated Control Tower |
| Vessel Capacity | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (Air, O2, N2, CO2) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring | Chaotic Mixing mode + conventional profile/Cascade control |
| Speed range | 1–2200 rpm |
| Reversibility | Yes |
| Sensors Supported | pH, DO, temperature, level, foam, CO₂, conductivity, turbidity |
| Peristaltic Pumps | 4 × Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Flow range | 1–270 mL/min |
| Software | Touch-enabled tablet interface (10.4″), real-time data logging, calibration management, FDA 21 CFR Part 11-compliant version optional |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Connectivity | Ethernet, USB, RS232, Wi-Fi, external thermostat & pump interfaces |
| Enclosure Rating | IP20 |
| Power | 100–240 V AC, 50/60 Hz |
| Max. input power | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Model | HABITAT Photo Ferment CCT |
| Vessel Volume | 0.5–10 L |
| Gas Supply | Four independent mass flow-controlled gas lines (N₂, O₂, air, CO₂) |
| pH Control Range | 0–14 pH |
| Accuracy | ±0.02 pH |
| Dissolved Oxygen (DO) Control Range | 0–200% saturation |
| Accuracy | ±0.3% sat |
| Temperature Control Range | 0–100 °C |
| Accuracy | ±0.2 °C |
| Stirring Speed | 1–2200 rpm |
| Speed Deviation | ±2% (≥100 rpm), ±5 rpm (<100 rpm) |
| LED Illumination | Adjustable intensity & timing for circadian simulation |
| Chaotic Mixing Mode | Enabled |
| Integrated Peristaltic Pumps | 4 Watson-Marlow 114DV heads (acid, base, antifoam, feed) |
| Data Storage | 32 GB internal |
| Compliance Options | FDA 21 CFR Part 11–compliant software version available |
| Interfaces | Ethernet, USB, RS232, external pump/thermostat/single-use reactor ports |
| Protection Rating | IP20 |
| Power Input | 100–240 V, 50/60 Hz |
| Max. Power Consumption | 1100 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | HABITAT photo ferment |
| Vessel Volume | 0.5–10 L |
| Aeration System | Integrated 4-channel mass flow controllers (N₂, O₂, air, CO₂) |
| pH Control | Range 0–14, Accuracy ±0.02 |
| Dissolved Oxygen (DO) Control | Range 0–200% saturation, Accuracy ±0.03% |
| Temperature Control | Range 0–100 °C, Accuracy ±0.2 °C |
Show next