- All
- Favorite
- Popular
- Most rated
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/12 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| External Water Jacket Volume | ~8 L |
| Internal Water Jacket Volume | ~2.5 L |
| Max. Oxygen Pressure | 40 bar |
| Cooling Medium Flow Rate | 60–70 L/h (at 18 °C) |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Rated Input Power | 2000 W |
| Protection Rating | IP20 |
| Ambient Operating Conditions | 20–25 °C, ≤80% RH |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 6000 Isoperibol Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibol (Isothermal) and Dynamic |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Sample Throughput | 4 measurements/h (isoperibol), 6 measurements/h (dynamic) |
| Heat Capacity Calibration Range | 40,000 J |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Cooling Medium | Tap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible) |
| Max. Oxygen Pressure | 40 bar |
| Dimensions | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Ambient Operating Conditions | 20–25 °C, ≤80 % RH |
| Ingress Protection | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz, 2000 W |
| Compliance Standards | DIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | IKA C 3000 eco Package |
| Instrument Type | Bomb Calorimeter |
| Measurement Mode | Isoperibolic Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibolic mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity | 40,000 J |
| Outer Water Jacket Volume | unspecified |
| Inner Water Jacket Volume | unspecified |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Country of Origin | Imported |
| Model | C 7000 Basic Equipment Set 1 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol Dry-Mode Combustion Calorimetry (ISO 1928) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i) |
| Single-Sample Test Duration | ~3–5 min |
| Heat Capacity | 30,000 J/K |
| Cooling Medium | Tap water |
| Minimum Cooling Flow Rate | 120–180 L/h |
| Max Operating Oxygen Pressure | 40 bar |
| Max Cooling Medium Pressure | 9 bar |
| Ambient Temperature Range | 18–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Power Supply | 220–240 V, 50/60 Hz |
| Input Power | 260 W |
| Dimensions (W×D×H) | 310 × 395 × 490 mm |
| Weight | 50.162 kg |
| Interfaces | RS232 (balance, printer, PC), Centronics printer port |
| Oxygen Bomb Recognition | Automatic encoded detection |
| Compatible Crucibles | C14 combustion crucibles (retrofittable) |
| Software | C5040 CalWin v3.x (menu-driven, GLP-compliant data handling) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Mode | Static Jacket (22 °C and 30 °C) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40 000 J |
| Cooling Medium | Tap Water |
| Cooling Flow Rate | 50–60 L/h (55 L/h at 18 °C) |
| Max Oxygen Pressure | 40 bar |
| Ambient Operating Temperature | 5–40 °C |
| Relative Humidity Limit | 80 % RH |
| Protection Rating | IP20 |
| Power Supply | 100–240 V, 50/60 Hz |
| Power Consumption | 120 W |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Compliance | DIN 51900, ISO 1928 |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | C 1 Package 1/10 |
| Instrument Type | Bomb Calorimeter |
| Measurement Principle | Isoperibol (Regnault–Pfaundler isothermal principle) |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.15 % RSD (1 g benzoic acid, NBS 39i) |
| Single-Sample Test Time | 11 min |
| Heat Capacity | 40,000 J |
| Outer Water Bath Capacity | Not specified |
| Inner Water Bath Capacity | Not specified |
| Cooling Medium | Tap water |
| Min. Coolant Flow Rate | 50–60 L/h at 18 °C |
| Max. Oxygen Pressure | 40 bar |
| Protection Rating | IP20 |
| Dimensions | 290 × 280 × 300 mm |
| Weight | 15 kg |
| Ambient Operating Conditions | 5–40 °C, ≤80 % RH |
| Compliance | DIN 51900, ISO 1928 |
| Interfaces | RS232 (balance, printer, PC), USB |
| Power Supply | 100–240 V, 50/60 Hz, 120 W |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA Works GmbH & Co. KG |
| Instrument Type | Oxygen Bomb Calorimeter |
| Measurement Modes | Adiabatic, Isoperibol (Isothermal), Dynamic |
| Temperature Range | 22–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i) |
| Single-Sample Test Time | 15 min |
| Heat Capacity Calibration Range | 40,000 J |
| Cooling Circulator | RC 2 Basic |
| External Water Jacket Capacity | Not specified |
| Internal Water Jacket Capacity | Not specified |
| Max Oxygen Pressure | 40 bar |
| Cooling Medium | Tap water |
| Min Flow Rate | 60 L/h |
| Max Flow Rate | 70 L/h |
| Ambient Operating Temp | 20–25 °C |
| Relative Humidity Limit | ≤80% RH |
| Protection Class | IP20 |
| Power Supply | 220–240 V / 100–120 V, 50/60 Hz |
| Input Power | 2000 W |
| Dimensions (W×D×H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | C 3000 eco |
| Calorimetric Principle | Isoperibol Oxygen Bomb Calorimetry |
| Temperature Range | 20–30 °C |
| Temperature Resolution | 0.0001 K |
| Precision | 0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i) |
| Single-Sample Measurement Time | 15 min |
| Heat Capacity Calibration Range | Up to 40,000 J |
| Outer Water Jacket Volume | Approx. 3.5 L |
| Inner Water Bucket Volume | Approx. 2.2 L |
| Operating Ambient Temperature | 20–30 °C |
| Relative Humidity Limit | ≤80 % RH |
| Protection Rating | IP20 (DIN EN 60529) |
| Power Supply | 220–240 V, 50/60 Hz, 1700 W |
| Dimensions (W × D × H) | 500 × 425 × 450 mm |
| Weight | 29 kg |
| Cooling Medium | Tap water or external chiller (e.g., RC 2 basic) |
| Oxygen Pressure | Up to 40 bar |
| Compliance Standards | ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213 |
| Data Interfaces | Ethernet, RS232, USB, SD card slot |
| Optional Accessories | C6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller |
Show next