Empowering Scientific Discovery

IKA (Guangzhou) Instrumentation & Equipment Co., Ltd. (IKA China)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelC 6000 Isoperibol Package 1/12
Instrument TypeBomb Calorimeter
Measurement ModeIsoperibol (Isothermal) and Dynamic
Temperature Range20–30 °C
Temperature Resolution0.0001 K
Precision0.05% RSD (isoperibol mode, 1 g benzoic acid NBS 39i)
Single Sample Test Time15 min
Heat Capacity40,000 J
External Water Jacket Volume~8 L
Internal Water Jacket Volume~2.5 L
Max. Oxygen Pressure40 bar
Cooling Medium Flow Rate60–70 L/h (at 18 °C)
Dimensions500 × 425 × 450 mm
Weight29 kg
Power Supply220–240 V / 100–120 V, 50/60 Hz
Rated Input Power2000 W
Protection RatingIP20
Ambient Operating Conditions20–25 °C, ≤80% RH
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelC 6000 Isoperibol Package 1/10
Instrument TypeBomb Calorimeter
Measurement ModeIsoperibol (Isothermal) and Dynamic
Temperature Range20–30 °C
Temperature Resolution0.0001 K
Precision0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i)
Sample Throughput4 measurements/h (isoperibol), 6 measurements/h (dynamic)
Heat Capacity Calibration Range40,000 J
External Water Jacket CapacityNot specified
Internal Water Jacket CapacityNot specified
Cooling MediumTap water (12–27 °C), max. pressure 1.5 bar, flow rate 60–70 L/h (KV600 chiller compatible)
Max. Oxygen Pressure40 bar
Dimensions500 × 425 × 450 mm
Weight29 kg
Ambient Operating Conditions20–25 °C, ≤80 % RH
Ingress ProtectionIP20
Power Supply220–240 V / 100–120 V, 50/60 Hz, 2000 W
Compliance StandardsDIN 51900, DIN EN ISO 1716, DIN EN ISO 9831, DIN EN 15170, DIN CEN TS 14918, ASTM D240, ASTM D4809, ASTM D1989, ASTM D5865, ASTM E711, ISO 1928, GB/T 213
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelIKA C 3000 eco Package
Instrument TypeBomb Calorimeter
Measurement ModeIsoperibolic Calorimetry
Temperature Range20–30 °C
Temperature Resolution0.0001 K
Precision0.05 % RSD (isoperibolic mode, 1 g benzoic acid NBS 39i)
Single-Sample Test Time15 min
Heat Capacity40,000 J
Outer Water Jacket Volumeunspecified
Inner Water Jacket Volumeunspecified
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ManufacturerIKA-Werke GmbH & Co. KG
Country of OriginImported
ModelC 7000 Basic Equipment Set 1
Instrument TypeBomb Calorimeter
Measurement PrincipleIsoperibol Dry-Mode Combustion Calorimetry (ISO 1928)
Temperature Range20–30 °C
Temperature Resolution0.0001 K
Precision0.2 % RSD (per 1 g benzoic acid, NIST SRM 39i)
Single-Sample Test Duration~3–5 min
Heat Capacity30,000 J/K
Cooling MediumTap water
Minimum Cooling Flow Rate120–180 L/h
Max Operating Oxygen Pressure40 bar
Max Cooling Medium Pressure9 bar
Ambient Temperature Range18–30 °C
Relative Humidity Limit≤80 % RH
Power Supply220–240 V, 50/60 Hz
Input Power260 W
Dimensions (W×D×H)310 × 395 × 490 mm
Weight50.162 kg
InterfacesRS232 (balance, printer, PC), Centronics printer port
Oxygen Bomb RecognitionAutomatic encoded detection
Compatible CruciblesC14 combustion crucibles (retrofittable)
SoftwareC5040 CalWin v3.x (menu-driven, GLP-compliant data handling)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelC 1
Instrument TypeOxygen Bomb Calorimeter
Measurement ModeStatic Jacket (22 °C and 30 °C)
Temperature Range20–30 °C
Temperature Resolution0.0001 K
Precision0.15 % RSD (1 g benzoic acid, NBS 39i)
Single-Sample Test Time11 min
Heat Capacity40 000 J
Cooling MediumTap Water
Cooling Flow Rate50–60 L/h (55 L/h at 18 °C)
Max Oxygen Pressure40 bar
Ambient Operating Temperature5–40 °C
Relative Humidity Limit80 % RH
Protection RatingIP20
Power Supply100–240 V, 50/60 Hz
Power Consumption120 W
Dimensions290 × 280 × 300 mm
Weight15 kg
ComplianceDIN 51900, ISO 1928
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Manufacturer TypeManufacturer
Origin CategoryImported
ModelC 1 Package 1/10
Instrument TypeBomb Calorimeter
Measurement PrincipleIsoperibol (Regnault–Pfaundler isothermal principle)
Temperature Range20–30 °C
Temperature Resolution0.0001 K
Precision0.15 % RSD (1 g benzoic acid, NBS 39i)
Single-Sample Test Time11 min
Heat Capacity40,000 J
Outer Water Bath CapacityNot specified
Inner Water Bath CapacityNot specified
Cooling MediumTap water
Min. Coolant Flow Rate50–60 L/h at 18 °C
Max. Oxygen Pressure40 bar
Protection RatingIP20
Dimensions290 × 280 × 300 mm
Weight15 kg
Ambient Operating Conditions5–40 °C, ≤80 % RH
ComplianceDIN 51900, ISO 1928
InterfacesRS232 (balance, printer, PC), USB
Power Supply100–240 V, 50/60 Hz, 120 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
ManufacturerIKA Works GmbH & Co. KG
Instrument TypeOxygen Bomb Calorimeter
Measurement ModesAdiabatic, Isoperibol (Isothermal), Dynamic
Temperature Range22–30 °C
Temperature Resolution0.0001 K
Precision0.05% RSD (Adiabatic & Isothermal, 1 g benzoic acid NBS 39i)
Single-Sample Test Time15 min
Heat Capacity Calibration Range40,000 J
Cooling CirculatorRC 2 Basic
External Water Jacket CapacityNot specified
Internal Water Jacket CapacityNot specified
Max Oxygen Pressure40 bar
Cooling MediumTap water
Min Flow Rate60 L/h
Max Flow Rate70 L/h
Ambient Operating Temp20–25 °C
Relative Humidity Limit≤80% RH
Protection ClassIP20
Power Supply220–240 V / 100–120 V, 50/60 Hz
Input Power2000 W
Dimensions (W×D×H)500 × 425 × 450 mm
Weight29 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandIKA
OriginGermany
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelC 3000 eco
Calorimetric PrincipleIsoperibol Oxygen Bomb Calorimetry
Temperature Range20–30 °C
Temperature Resolution0.0001 K
Precision0.05 % RSD (isoperibol mode, 1 g benzoic acid NBS 39i)
Single-Sample Measurement Time15 min
Heat Capacity Calibration RangeUp to 40,000 J
Outer Water Jacket VolumeApprox. 3.5 L
Inner Water Bucket VolumeApprox. 2.2 L
Operating Ambient Temperature20–30 °C
Relative Humidity Limit≤80 % RH
Protection RatingIP20 (DIN EN 60529)
Power Supply220–240 V, 50/60 Hz, 1700 W
Dimensions (W × D × H)500 × 425 × 450 mm
Weight29 kg
Cooling MediumTap water or external chiller (e.g., RC 2 basic)
Oxygen PressureUp to 40 bar
Compliance StandardsISO 1928, ASTM D240, ASTM D4809, ASTM D5865, GB/T 213
Data InterfacesEthernet, RS232, USB, SD card slot
Optional AccessoriesC6010 & C6012 decomposition bombs, RC 2 basic recirculating chiller
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0