Illuminance Meter
Filter
Showing 31–60 of 70 results
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | T-10 / T-10M |
| Illuminance Range | 0.01–299,900 lx |
| Spectral Match | f₁′ ≤ 8% (vs. CIE V(λ)) |
| Cosine Error | ±1% at 10°, ±7% at 60°, ±25% at 80° |
| Accuracy | ±2% ±1 digit (Konica Minolta standard) |
| Output | RS-232C digital, 1 mV/digit analog |
| Display | Backlit LCD, 3–4 digits |
| Operating Temp | –10 to 40°C, RH ≤ 85% (non-condensing) |
| Power | 2× AA batteries (≥72 h continuous) |
| Dimensions (main unit) | 69 × 161.5 × 30 mm |
| Weight | 200 g (T-10), 205 g (T-10M) |
| Compliance | Designed for ISO/CIE-compliant photometric measurement in industrial, architectural, and environmental applications |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Model | T-10 |
| Compliance | JIS C 1609-1:2006 Class AA (except f₂), DIN 5032-7 Class B |
| Measurement Range | 0.01–299,900 lx |
| Cosine Error (f₂) | ≤3% |
| Spectral Mismatch (f₁′) | ≤6% |
| Output | USB + Analog (1 mV/digit, max 3 V) |
| Operating Temp | −10–40°C |
| Battery Life | ≥72 h (alkaline) |
| Brand | Konica Minolta |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Konica Minolta T-10A Series Handheld High-Precision Illuminance Meter |
| Price | USD 980 (FOB Yokohama) |
| Compliance | JIS C 1609-1:2006 Class AA |
| Measurement Range | 0.1–299,900 lx (typical, dependent on probe configuration) |
| Spectral Response | f1' ≤ 3.0% (JIS AA-compliant) |
| Cosine Correction Error | ≤ ±2% (up to 75° incidence) |
| Sampling Rate | 10 Hz (standard), configurable up to 100 Hz for PWM analysis |
| Probe Connectivity | Detachable via shielded LAN cable (IEC 61000-4-3 compliant interface) |
| Multi-point Capability | 2–30 independent measurement points (synchronized acquisition) |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | LJ350UV |
| Price | USD 1,390 (FOB Qingdao) |
| Wavelength Range | 200–400 nm (UV-C to UV-A) |
| Spectral Bandwidth (FWHM) | 2 nm |
| Optical Resolution | 0.2 nm |
| Wavelength Accuracy | ±0.5 nm |
| Detector | High-precision CCD array |
| Input Aperture | Ø10 mm |
| Display | 5.0" IPS capacitive touchscreen |
| Operating System | Embedded Linux |
| Battery | 4000 mAh Li-ion, 10 h continuous operation |
| Data Storage | 4 GB microSD (≥60,000 records) |
| Interface | USB Type-C (≥1 A current rating) |
| Illuminance Accuracy | Class I (±4% reading ±1 digit) |
| Chromaticity Repeatability | ±0.0005 in CIE 1931 (x,y) |
| CCT Range | 1,000–100,000 K |
| Stray Light | ≤0.3% |
| Operating Temp. | −10 to +40 °C, RH <70% (non-condensing) |
| Storage Temp. | −20 to +45 °C, RH <70% (non-condensing) |
| Dimensions | 146 × 81 × 22.8 mm |
| Weight | ~300 g (body only, with battery) |
| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-250A |
| Sensor Type | Silicon Photodiode |
| Accuracy (25 °C) | ±0.4% of full scale ±3 digits |
| Accuracy (0–55 °C) | ±0.6% of full scale ±3 digits |
| Range Selection | Auto-ranging across 3 scales |
| Linearity | ±0.05% |
| Display | Digital LCD, 0.5 s update in instantaneous mode |
| Power | One 9 V alkaline battery (150 h typical life) |
| Operating Environment | 0–55 °C, 0–95% RH (non-condensing) |
| Storage | −55–60 °C, 0–95% RH (non-condensing) |
| Dimensions | 14 × 7.7 × 3.8 cm |
| Weight | 0.26 kg |
| IP Rating | Rain- and dust-resistant (O-ring sealed enclosure) |
| Signal Averaging | 15 s moving average (~60 samples) |
| Input Interface | BNC connector for LI-COR radiation sensors |
| Calibration | User-entered sensor-specific calibration coefficient |
| Brand | Photo Research |
|---|---|
| Origin | USA |
| Model | PR1050 |
| Dynamic Range | 500,000,000:1 |
| Spectral Bandwidth | 2, 5, or 8 nm (auto-selectable) |
| Detector | Back-illuminated CCD, 512 pixels, thermoelectrically cooled |
| Color Accuracy (CIE 1931 x,y) | ±0.0015 at 5.14E−4 cd/m² (A-source, 2856 K, 2° FOV, 8 nm BW) |
| Color Repeatability | ±0.0005 at 1.19E−2 cd/m² (A-source, 2° FOV) |
| Luminance Sensitivity | 1.71E−5 cd/m² (10:1 SNR, 2° FOV, 8 nm BW) |
| Luminance Accuracy | ±2% (NIST-traceable A-source, 5.14E−4 cd/m²) |
| Luminance Repeatability | ≤1% (NIST-traceable A-source, 5.14E−4 cd/m²) |
| Exposure Time | 7 ms – 120 s |
| Polarization Error | <0.2% (at 3.34 cd/m², 2° FOV) |
| Stray Light | <0.06% |
| Wavelength Accuracy | <0.4 nm |
| Spectral Resolution | 1 nm |
| Digital Resolution | 16-bit |
| Interfaces | USB, RS-232 |
| Apertures | 2°, 1°, 0.5°, 0.25°, 0.2°, 0.125°, 0.1°, 0.1°×1° (vertical slit), 0.5°×1.5° (horizontal slit) |
| Power | Rechargeable Li-ion battery or 90–240 VAC adapter |
| Battery Life | Up to 8 hours |
| Weight | 6.01 kg |
| Dimensions | 28.0 × 17.0 × 20.3 cm |
| Operating Temperature | 1–35 °C |
| Relative Humidity | 0–90% RH (non-condensing) |
| Brand | AOLONG |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | HENT31-021A |
| Price | Upon Request |
| Radiation Types Detected | γ and X-rays (60 keV – 1.33 MeV) |
| Dose Rate Range | 0.01 µSv/h – 300 µSv/h |
| Cumulative Dose Range | 0.1 µSv – 1 Sv |
| Count Rate | 1 – 10,000 cps |
| Dose Rate Accuracy | < ±15% |
| Power Supply | 2 × AA batteries |
| Ingress Protection | IP65 |
| Operating Temperature | −10 °C to +50 °C |
| Brand | Senbe |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | ST-85 |
| Instrument Type | Silicon Photocell-Based Illuminance Meter |
| Measurement Range | 0.1–199.9 × 10³ lx |
| Relative Indication Error | < ±4.0% |
| V(λ) Matching Error (f₁) | < 6.0% |
| Cosine Correction Error (f₂) | < 4.0% |
| Nonlinearity Error (f₃) | < ±1.0% |
| Range Switching Error (f₄) | < ±1.0% |
| Fatigue Error (f₅) | < −0.5% |
| Response Time | < 1 s |
| Operating Temperature | 0–40 °C |
| Operating Humidity | < 85% RH |
| Dimensions | 160 mm × 78 mm × 43 mm |
| Weight | 0.2 kg |
| Power Supply | 6F22 9 V alkaline battery (non-rechargeable) |
| Total Power Consumption | < 0.1 VA |
| Display | Backlit LCD |
| Range Selection | Manual/Automatic |
| Output Interface | USB digital output with redundant power capability |
| Additional Functions | Data hold, low-battery indicator, auto power-off delay, tactile key operation with audible beep feedback |
| Brand | Kipp & Zonen |
|---|---|
| Origin | Netherlands |
| Model | SGR3 |
| Spectral Range | 4.4–50 µm |
| Response Time | <18 s |
| Zero Offset (B) | <5 W/m² |
| Temperature Dependence of Sensitivity (−20 to +50 °C) | <3% |
| Operating Temperature Range | −40 to +80 °C |
| Field of View | 150° |
| Analog Output | 4–20 mA or 0–1 V per W/m² |
| Window Heating Offset | 15 W/m² |
| Power Supply | 5–30 VDC |
| Communication Interface | RS-485 Modbus® |
| Desiccant Replacement Interval | ≥10 years |
| Directional Error | <5 W/m² |
| Temperature Correction Range | −40 to +80 °C |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2100 |
| Detector Inputs | 2 |
| Input Ranges | ±0.4 V, ±4 V (auto-ranging) |
| Resolution (±0.4 V range) | 15 µV |
| Dynamic Range | >2×10⁵ |
| Accuracy | ±0.5% FS across all ranges |
| Nonlinearity | ≤0.02% FS per range |
| Temperature Coefficient | ≤50 ppm/°C |
| Data Memory | 1024 points |
| Operating Temperature | 0–50 °C |
| Power | 4×AA NiCd or alkaline batteries |
| Weight | 480 g (17 oz) |
| Dimensions | 10 × 19.5 × 4.5 cm (4″ W × 7.6″ H × 1.75″ D) |
| Safety Compliance | UL 61010-1 Annex DVC |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2101 |
| Spectral Response | CIE 1987 Erythema Action Spectrum (280–320 nm) |
| Angular Response | Lambertian (cosine-corrected, ≤5% deviation up to 60°) |
| Measurement Range | 0.01 µW/cm² to >1 mW/cm² |
| Units | MED/hr, µW/cm², W/m² |
| Calibration | NIST-traceable |
| Operating Temperature | 0–50 °C (non-condensing) |
| Dimensions | Ø40.6 mm × 45.8 mm |
| Weight | 200 g |
| Cable | Retractable 0.3–1.5 m |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2106 |
| Detection Principle | Broadband Non-Weighted UVB (280–320 nm) |
| Spectral Response | Flat, Unfiltered Silicon Photodiode with UVB-optimized optical filter |
| Angular Response | Lambertian (Cosine-corrected, ±5% up to 60° incidence) |
| Measurement Range | 0.001–200 mW/cm² (0.01–2000 W/m²) |
| Resolution | 0.001 mW/cm² / 0.01 W/m² |
| Operating Temperature | 0–50 °C (32–120 °F), non-condensing |
| Temperature Coefficient | ±1 %/°C (for solar UVB irradiance) |
| Cable | Retractable coaxial, 0.3–1.5 m |
| Dimensions | Ø40.6 mm × H45.8 mm |
| Weight | 200 g |
| Calibration | NIST-traceable, factory-calibrated for UVB irradiance (mW/cm² and W/m²) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2106 |
| Detection Principle | Broadband Non-Weighted UVB (280–320 nm) |
| Spectral Response | Flat, Unfiltered Silicon Photodiode with UVB-optimized optical filter |
| Angular Response | Lambertian (Cosine-corrected, ±5% up to 60° incidence) |
| Measurement Range | 0.001–200 mW/cm² (0.01–2000 W/m²) |
| Resolution | 0.001 mW/cm² / 0.01 W/m² |
| Operating Temperature | 0–50 °C (32–120 °F), non-condensing |
| Temperature Coefficient | ±1 %/°C (for solar UVB irradiance) |
| Calibration Traceability | NIST-traceable |
| Cable | Retractable coaxial cable, 0.3–1.5 m |
| Dimensions | Ø40.6 mm × H45.8 mm |
| Weight | 200 g |
| Compliance | ASTM E772, ISO 17166:1999 (CIE S 007/E), FDA 21 CFR Part 11 (when used with compliant PMA-series meter) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2107 |
| Spectral Range | 280–400 nm (UVA: 315–400 nm, UVB: 280–315 nm) |
| Detector Type | Silicon photodiode with precision optical filter and cosine-corrected diffuser |
| Angular Response | ≤5% deviation from ideal Lambertian response up to 60° incidence angle |
| Measurement Range | 0.001–200 mW/cm² (0.01–2000 W/m²) |
| Resolution | 0.001 mW/cm² / 0.01 W/m² |
| Operating Temperature | 0–50 °C (32–120 °F), non-condensing |
| Temperature Coefficient | ±1 %/°C (for solar irradiance) |
| Calibration | NIST-traceable, factory-calibrated for broadband UVA+UVB irradiance |
| Physical Dimensions | Ø40.6 mm × H45.8 mm |
| Weight | 200 g |
| Cable | Retractable coaxial cable, 0.3–1.5 m |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2110 |
| Spectral Range | 320–400 nm |
| Cosine Error | ≤5% at angles <60° |
| Measurement Range | 0.001–200 mW/cm² (or 0.01–2000 W/m²) |
| Resolution | 0.001 mW/cm² / 0.01 W/m² |
| Operating Temperature | 0–50 °C |
| Detector Diameter | 40.6 mm |
| Height | 45.8 mm |
| Weight | 200 g |
| Cable | Retractable, 0.3–1.5 m |
| Temperature Coefficient | <0.1 %/°C |
| Environmental Rating | Indoor use only |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2112 |
| Spectral Range | 320–390 nm |
| Peak Sensitivity | ~365 nm |
| Operating Tip Temperature | 0–400 °C |
| Sensor Operating Temperature | 0–50 °C |
| Dynamic Range | 0.1 mW/cm² to 20 W/cm² |
| Display Resolution | 0.1 mW/cm² |
| Temperature Coefficient | <0.05 %/°C |
| Probe Diameter | 9.5 mm (0.375 in) |
| Probe Length | 18 in (457 mm) |
| Overall Dimensions | 40.6 mm × 500 mm |
| Weight | 425 g (15 oz) |
| Cable | Retractable, 0.3–1.5 m |
| Radiometric Units | kW/m², W/cm², or mW/cm² (user-selectable) |
| Dose Integration | Yes, with START/STOP control and 1024-point memory buffer |
| Compliance | NIST-traceable calibration |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2120 |
| Spectral Response | Aligned with ACGIH UV Hazard Action Spectrum (Fig. 1) |
| Angular Response | ≤5% deviation up to 60° from normal incidence |
| Measurement Range | 0–1 mW/cm² |
| Display Resolution | 0.01 μW/cm² |
| Dose Calculation | Real-time integration to mJ/cm² |
| TLV Mode | Displays time-to-reach ACGIH TLV (3 mJ/cm² per 8-hr shift) |
| Operating Temperature | 0–50 °C (32–120 °F), non-condensing |
| Cable | Retractable 0.3–1.5 m |
| Dimensions | Ø40.6 mm × H45.8 mm |
| Weight | 200 g |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PMA2121 |
| Price | Upon Request |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2123 |
| Spectral Range | 425–475 nm |
| Calibration | NIST-traceable |
| Output Unit | μW/cm²/nm |
| Cosine Correction | Yes |
| Stability | Long-term drift < ±0.5% per year |
| Dynamic Range | 10⁴:1 (typical) |
| Detector Type | Silicon photodiode with bandpass interference filter |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2130 |
| Spectral Response | CIE 1931 photopic luminous efficiency function (V(λ), 400–700 nm) |
| Cosine Correction | Integrated, ±5% up to 60° incidence angle |
| Measurement Range (PMA2130 standard variant) | 1–150,000 lx |
| Radiometric Equivalent | 0.001–220 W/m² |
| Illuminance Units | lux (lx), foot-candle (ft-cd), W/m² |
| Display Resolution | 1 lx / 0.001 W/m² / 0.1 ft-cd |
| Operating Temperature | 0–50 °C |
| Dimensions | Ø40.6 mm × 45.8 mm |
| Weight | 200 g |
| Calibration | NIST-traceable, certified per ISO/IEC 17025 accredited laboratory |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2131 |
| Spectral Response | CIE scotopic luminosity function (V′(λ), 400–600 nm) |
| Angular Response | ≤5% deviation up to ±60° |
| Measurement Range | 200,000 scotopic mLux / 20,000 mft-cd / 120,000 µW/m² |
| Resolution | 1 mLux / 0.1 mft-cd / 1 µW/m² |
| Operating Temperature | 0–50 °C (32–120 °F), non-condensing |
| Detector Diameter | 40.6 mm |
| Height | 45.8 mm |
| Weight | 200 g |
| Calibration | NIST-traceable |
| Cable | Retractable, 0.3–1.5 m |
| Cosine Correction | Integrated |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2132 |
| Spectral Range | 400–700 nm |
| Calibration | NIST-traceable |
| Cosine Response Error | ≤5% up to 80° incidence angle |
| Measurement Range | 0–20,000 µE·s⁻¹·m⁻² |
| Resolution | 0.1 µE·s⁻¹·m⁻² |
| Operating Temperature | −40 to +50 °C |
| Cable Length | 15 m (standard), optional retractable 0.3 m |
| Dimensions | Ø40.6 mm × 45.8 mm |
| Weight | 200 g |
| Temperature Coefficient | <0.15 %/°C |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2133 |
| Spectral Response | CIE Photopic Luminosity Function (400–700 nm) |
| Field of View | 8° |
| Measurement Range | 0–6,800 cd/m² (0–2,000 fL) |
| Resolution | 0.01 cd/m² or 0.01 fL |
| Operating Temperature | 0–50 °C |
| Cable Length | 1.5 m |
| Detector Diameter | 40.6 mm |
| Height | 81.3 mm |
| Weight | 110 g |
| Calibration | NIST-traceable cosine-corrected photometric calibration |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2140 |
| Spectral Range | 400–1100 nm |
| Cosine Response Error | ≤5% for incident angles <60° |
| Measurement Range | 0–2000 W/m² |
| Resolution | 0.01 W/m² |
| Operating Temperature | 0–50 °C (non-condensing) |
| Detector Diameter | 40.6 mm |
| Height | 45.8 mm |
| Weight | 200 g |
| Cable Length | 0.3 m (standard), extendable to 1.5 m |
| Compliance | ASTM G173, ISO 9060:2018 Class C (reference-grade context) |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2143 |
| Spectral Response | 0.2–50 µm |
| Field of View | 10° |
| Angular Response | ≤2% for incident angles <70° |
| Measurement Range | 1500 MED/hr or 150 µW/cm² |
| Display Resolution | 1 W/m² / 0.1 mW/cm² |
| Response Time | 30 s |
| Operating Temperature | −40 to +80 °C |
| Temperature Coefficient | ±6% (−10 to +40 °C) |
| Nonlinearity | ≤3% (at 50 mV output) |
| Detector Diameter | 40.6 mm |
| Cable Length | 1.82 m |
| Weight | 240 g |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2144 |
| Spectral Range | 310–2800 nm |
| Full-Scale Range | 2000 W/m² (200 mW/cm²) |
| Response Time | 18 s (95%) |
| Annual Drift | <1% |
| Nonlinearity | <2.5% (at 1000 W/m²) |
| Thermal Zero Offset | <15 W/m² (at 200 W/m²) |
| Cosine Response Error | ≤2% up to 70° zenith angle |
| Operating Temperature | −40 to +80 °C |
| Cable Length | 9 m |
| Sensor Diameter (with shade) | 60.3 mm |
| Weight | 0.31 kg |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2145 |
| Spectral Range | 310–2800 nm (FWHM) |
| Full-Scale Range | 2000 W/m² |
| Response Time | 18 s (95%) |
| Annual Drift | <1% |
| Nonlinearity | <1.0% (at 1000 W/m²) |
| Temperature Dependence | <2% (-10 to +40 °C) |
| Cosine Response Error | ≤1% up to 70° zenith angle |
| Zero Offset | <15 W/m² at 200 W/m² net irradiance |
| Resolution | 1 W/m² / 0.1 mW/cm² |
| Operating Ambient | -40 to +80 °C |
| Cable Length | 9 m |
| Sensor Diameter (with shade) | 60.3 mm |
| Height | 84.0 mm |
| Weight | 0.31 kg |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | PMA2200 |
| Detector Input | 1 channel (supports up to 4 analog signals from PMA21XX-series detectors) |
| Input Range | ±4 V |
| Resolution | 3 µV |
| Dynamic Range | 2.6 × 10⁶ (6.5-digit equivalent) |
| Accuracy | ±0.2% of full scale |
| Integral Non-Linearity | ±0.003% |
| Temperature Coefficient | ≤50 ppm/°C |
| Sampling Rate | 3 samples/sec |
| Display Refresh Rate | 10 Hz |
| Operating Temperature | 0–50 °C |
| Power | 4 × AA alkaline batteries (>40 h continuous operation) or external 9–12 V AC/DC adapter |
| Power Consumption | ~110 mW |
| Weight | 510 g (18 oz) |
| Dimensions | 10 × 19.5 × 4.5 cm (W × H × D) |
| LCD Size | 6.4 × 1.3 cm (2.5" × 0.5") |
| Brand | Solar Light |
|---|---|
| Origin | USA |
| Model | SL-3101 |
| Detector Type | Silicon Photodiode |
| Dynamic Range | 2.6 × 10⁶ (6.5 digits) |
| Accuracy | ±0.2% FS |
| Integral Non-linearity | 0.003% |
| Temperature Coefficient | ≤50 ppm/°C |
| Sampling Rate | 3 Hz |
| Display Refresh Rate | 10 Hz |
| Operating Temperature | 0–50 °C (non-condensing) |
| Power | 4 × AA alkaline batteries (≥40 h continuous), or 9–12 V AC/DC adapter (≥100 mA) |
| Weight | 510 g |
| Dimensions | 10 × 4.35 × 19.3 cm |
| LCD Size | 6.4 × 1.3 cm |
| Keypad | 9-key programmable interface |
| Photopic Sensor (PMA2130) | Spectral Response per CIE V(λ) (400–700 nm), Angular Response ≤5% at <60°, Range: 1–150,000 lx / 0.1–14,000 ft-cd, Resolution: 1 lx / 0.1 ft-cd |
| Scotopic Sensor (PMA2131) | Spectral Response per CIE V′(λ) (400–600 nm), Angular Response ≤5% at <60°, Range: 1–150,000 lx / 0.1–14,000 ft-cd, Resolution: 1 lx / 0.1 ft-cd |
| Sensor Diameter | 40.6 mm |
| Sensor Height | 45.8 mm |
| Sensor Weight | 200 g each |
| Brand | TES |
|---|---|
| Origin | Taiwan |
| Model | TES-1339 |
| Measurement Range | 0.01–999,900 Lux (5 auto-ranging scales) |
| Resolution | 0.01 Lux / 0.001 fc |
| Accuracy | ±3% of reading ±5 digits (calibrated at 2856 K standard incandescent source) |
| Response Time | ~5 readings/sec |
| Photodetector | Silicon photodiode with cosine-corrected diffuser |
| Memory Capacity | 50 data sets |
| Operating Temp | 0–50°C, <80% RH |
| Power | 6× AAA batteries (~100 h life) |
| Sensor Cable Length | 150 cm |
| Dimensions (Meter) | 150 × 72 × 33 mm |
| Weight | ~250 g |
| Compliance | CNS 5119 Class II |