| Brand | Asida |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China-made) |
| Model | XK Series |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution | XK16/XK22: 0.70–5.20 µm/pixel |
| XK23 | 0.4–2.6 µm/pixel |
| Total Optical Magnification | 70×–450× |
| Objective Magnification | 1.4×–9× (continuous) |
| Maximum Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Instrument Dimensions (w/o PC) | XK16: 135×135×310 mm |
| XK22 | 960×700×1280 mm |
| XK23 | 960×780×1280 mm |
| Weight | XK16: 1.52 kg |
| XK22 | 145 kg |
| XK23 | 190 kg |
| Brand | ASIDA |
|---|---|
| Model | XK22 |
| Origin | Guangdong, China |
| Type | Optical Metrology System for Printed Circuit Board Inspection |
| Measurement Principle | High-Resolution Digital Microscopy with Sub-Pixel Edge Detection |
| Max. Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution | 0.70–5.20 µm/pixel |
| Total Magnification Range | 70×–450× |
| Optical Zoom | 1.4×–9× Continuous |
| SPC Capability | Yes |
| Illumination | Red LED Targeting Light |
| Weight (system only) | 145 kg |
| Dimensions (W×D×H, excl. PC) | 960×700×1280 mm |
| Compliance | Designed for IPC-6012, IPC-A-600, and ISO 9001-aligned QA/QC workflows |
| Software | Proprietary ASIDA Vision Suite with Audit Trail & Export to CSV/XLSX |
| Brand | ASIDA |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | XK23 |
| Pricing | Available Upon Request |
| Measurement Accuracy | ±1 µm |
| Pixel Resolution (XK23) | 0.4–2.6 µm/pixel |
| Total Magnification | 70–450× |
| Optical Zoom | 1.4–9× Continuous |
| Maximum Board Width | ≤760 mm |
| Field of View | 0.53×0.4 mm to 3.4×2.5 mm |
| Minimum Measurable Line Width | ≥20 µm |
| Instrument Dimensions (excl. PC) | 960×780×1280 mm |
| Weight | 190 kg |
| [Brand | AST |
|---|---|
| Origin | Shanghai, China |
| Model | DM8116 |
| Detection Target | Total Sulfur |
| Detection Limit (300 s) | 0.33 ppm |
| X-ray Tube | Ag anode, ≤50 kV / ≤2 mA / ≤50 W, micro-focus, thin Be window |
| Crystal | Logarithmic Spiral Doubly Curved Crystal (LSDCC) |
| Detector | Ultra-thin Be window proportional counter |
| Standards Compliance | GB/T 11140, ISO 20884, SH/T 0842, ASTM D2622, ASTM D7039, ASTM D7220 |
| Measurement Range | 3×LOD to 9.99 wt% |
| Analysis Time | 1–999 s (recommended: 300 s for trace, 60 s for major) |
| Operating Environment | 5–40 °C, ≤85% RH at 30 °C, 220 V ±20 V, 50 Hz, ≤200 W |
| Dimensions & Weight | 330 × 460 × 350 mm, 25 kg] |
| Brand | ASTEL/ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM1260 |
| Detection Method | Total Sulfur Quantification |
| Detection Limit (300 s) | 3.9 ppm |
| Compliance | GB/T 17040–2019, GB 17411, ASTM D4294 |
| X-ray Tube | ≤20 kV, ≤1 mA, ≤10 W |
| Detector | Ultra-thin Be-window Proportional Counter |
| Measurement Range | 3×LOD to 9.99 wt% S |
| Analysis Time | 1–999 s (recommended: 100 s for major, 300 s for trace) |
| Operating Environment | 5–40 °C, ≤85% RH at 30 °C, 220 V ±20 V, 50 Hz, ≤100 W |
| Dimensions & Weight | 300 × 410 × 165 mm, 10 kg |
| Brand | ASTEL / ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM2400S/Cl |
| Detection Elements | Total Sulfur (S), Total Chlorine (Cl) |
| Detection Limits (300 s) | S: 0.26 ppm, Cl: 0.18 ppm |
| X-ray Tube | Ag-target, micro-focus, thin Be window, ≤50 kV / ≤2 mA / ≤50 W |
| Detector | Silicon Drift Detector (SDD), 20 mm² active area, ≤123 eV resolution at Mn Kα, ≤2 Mcps count rate |
| Primary Optic | Logarithmic Spiral Doubly Curved Crystal (LSDCC) artificial monochromator |
| Standards Compliance | GB/T 11140, ISO 20884, ASTM D2622, ASTM D7039, ASTM D7220, ASTM D4929, ASTM D7536, ISO 15597 |
| Measurement Range | 3×LOD to 9.99 wt% |
| Linear Correlation Coefficient (r) | >0.999 for both S and Cl calibration curves |
| Repeatability (r) & Reproducibility (R) | Meets or exceeds all referenced ASTM/ISO/GB standards |
| Operating Environment | 5–40 °C, ≤85% RH (at 30 °C), 220 V ±20 V, 50 Hz, <200 W |
| Dimensions & Weight | 330 × 460 × 350 mm, 25 kg |
| Origin | Switzerland |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 256000/M, ASTM D6 |
| Power Supply | 220 V / 50 Hz, 2000 W |
| Temperature Range | Ambient to 180 °C ± 1 °C |
| Temperature Control Accuracy | ±0.1 °C (PID + Pt100 RTD) |
| Rotational Speed | 5.5 rpm (adjustable 5–6 rpm) |
| Internal Chamber Dimensions | 60 × 80 × 80 cm (W × H × D) |
| Net Weight | ~30 kg |
| Safety Certification | CE |
| Compliance Standards | ASTM D6, ASTM D1754, IP 145 |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | AD0972-100 |
| Pricing | Available Upon Request |
| Brand | B&E / Balentine Enterprises |
|---|---|
| Origin | USA |
| Supplier Type | Authorized Distributor |
| Import Status | Imported |
| Model | ASTM IRB9 Industrial Reference Black |
| Pricing | Available Upon Request |
| Brand | B&E / Balentine Enterprises |
|---|---|
| Origin | USA |
| Model | IRB9 Carbon Black |
| Regulatory Compliance | ASTM D3182, D3191, D3192, D412 |
| Certification | NIST-traceable batch documentation available |
| Packaging | Sealed, moisture-controlled HDPE container (500 g standard) |
| Brand | B&E / Balentine Enterprises |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ITRB2 |
| Pricing | Available Upon Request |
| Brand | B&E / Balentine Enterprises |
|---|---|
| Origin | USA |
| Type | Imported Standard Reference Material |
| Model | ITRB2 |
| Price | Upon Request |
| Brand | FUNKE GERBER |
|---|---|
| Origin | Italy |
| Model | CryoSpecial 1 |
| Sample Volume | 2–2.5 mL |
| Measurement Principle | Freezing Point Depression (Colligative Property) |
| Temperature Range | +5 °C to +36 °C |
| Resolution | ±0.0005 °C |
| Reproducibility (Raw Milk) | ±0.0025 °C |
| Analysis Time | ~2 min (after preheating) |
| Preheat Time | ~5 min |
| Output Units | °C, °H, % Water Addition |
| Interface | RS232 |
| Power Supply | 220 V / 50 Hz / 150 W |
| Dimensions (W×D×H) | 29 × 44 × 33 cm |
| Weight | ~13 kg |
| Cooling System | Peltier-based, Continuous Circulation |
| Compliance | IDF-ISO 5764:2009, AFNOR, GB 5413.38–2010 |
| Certification | Verified by China National Institute of Metrology |
| Brand | ASTRO / ST |
|---|---|
| Origin | Shanghai, China |
| Model | DM1262 |
| Detection Method | Total Sulfur (S) by Energy-Dispersive X-ray Fluorescence (EDXRF) |
| Detection Limit (300 s, air atmosphere) | 2.6 ppm |
| Weight (incl. battery & thermal printer) | 5.6 kg |
| Measurement Range | 3×DL to 9.99 wt% S |
| Linearity Coefficient (r) | >0.999 across low/mid/high calibration ranges |
| Repeatability (r) & Reproducibility (R) | Compliant with GB/T 17040–2019, GB 17411, and ASTM D4294 |
| Operating Temperature | −10 °C to +40 °C |
| Relative Humidity | ≤95% at 35 °C |
| Power Supply | 11.1 V / 20.8 Ah Li-ion battery (≥5 h continuous operation) |
| Dimensions | 242 mm (W) × 258 mm (D) × 142 mm (H) |
| X-ray Tube | ≤10 kV, ≤1 mA, ≤10 W |
| Detector | Low-background ultra-thin Be-window proportional counter with secondary filtration |
| Pulse Processing | FPGA- and DSP-based digital multi-channel analyzer (MCA) with reduced dead time |
| Software | Embedded touchscreen OS with automatic C/H ratio correction, matrix effect compensation, and multi-range calibration curve switching |
| Regulatory Compliance | Meets radiation safety exemption criteria per CNPC and IAEA guidelines |
| Brand | Astroda |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PP CQ2000 |
| Pricing | Available Upon Request |
| Brand | ATI |
|---|---|
| Origin | USA |
| Model | 100X |
| Compliance | NIOSH 42 CFR Part 84, GB 2626–2019, GB 19083, EN 13274-7:2019, ASTM F3502-21, ISO 23328, YY 0469 |
| Aerosol Types | NaCl (salt) or DOP/PAO/paraffin oil |
| Flow Range | 10–170 L/min |
| Filtration Efficiency Range | up to 99.9995% |
| Sampling | 100% isokinetic aerosol sampling |
| Aerosol Reservoir | 3.8 L (1 gal) integrated patented replenishment system |
| Test Area | 100 cm² standard flat-media fixture |
| Configuration Options | Manual, Automatic (PLC-integrated), Hybrid |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | PMLT |
| Pricing | Upon Request |
| Dimensions (Packaged) | 81 cm × 57 cm × 51 cm |
| Weight (Packaged) | ~41 kg |
| Weight (Unpackaged) | ~26 kg |
| Power Supply | 100–250 V AC, 50/60 Hz |
| Aerosol Agent | Polyalphaolefin-4 (PAO-4) |
| Detection Principle | Near-forward light-scattering photometry |
| Detection Range | 0.0005–100% aerosol concentration |
| Fit Factor Limit | 200,000 |
| Data Interface | RS-232 serial port |
| Patents | US 6,435,009 |
| Brand | ATI |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PMLT |
| Price | USD $100,000 |
| Dimensions (Packaged) | 81 cm × 57 cm × 51 cm |
| Weight (Packaged) | ~41 kg |
| (Unpackaged) | ~26 kg |
| Power Supply | 100–250 V AC, 50/60 Hz |
| Aerosol Agent | Polyalphaolefin-4 (PAO-4) |
| Detection Principle | Near-forward light-scattering photometry |
| Detection Range | 0.0005–100% aerosol penetration |
| Fit Factor Limit | 200,000 |
| Data Interface | RS-232 serial port |
| Brand | ATLANTEK |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Model 400 |
| Pricing | Available Upon Request |
| Printing Method | Direct Thermal |
| Print Resolution | 300 dpi |
| Print Width | 53 mm |
| Sample Width | 100 mm |
| Printhead Architecture | Thin-Film, Corner-Type |
| Print Speed | Programmable at 10 in/s (254 mm/s) |
| Adjustable Parameters | Printhead Pressure, Printhead Position |
| Interface | RS-232 Serial |
| Power Supply | 115 V / 60 Hz or 220 V / 50 Hz |
| Test Patterns | Checkerboard, Solid Fill, UPC-A Barcode, User-Defined Patterns |
| Test Modes | Dynamic Reaction Sequence (10 programmable energy steps), Single-Step Execution, Repetition Options (1×, 5×, 10× per step) |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Model | 00100112 |
| Load Cell Capacity | 2000 g |
| Slider Dimensions | 63.5 × 63.5 mm |
| Standard Slider Mass | 200 g |
| Test Speed Range | 1–900 mm/min |
| Total Slider Travel | 400 mm |
| Test Area | 200 × 400 mm |
| Temperature Control Option | 0–120 °C |
| Data Output | USB interface |
| Compliance Standards | ASTM D1894 (Method B), ISO 8295, DIN 53375 |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 100 |
| Price | Upon Request |
| Standards | ASTM D1598, DIN 8062, ISO 1167, ISO 4427, EN 1447, EN 1452-2 |
| Test Stations | 6 independent stations |
| Pressure Systems | 2 independent hydraulic circulation systems |
| Pumps per System | 3 |
| Max Pressure | 100 bar |
| Pressure Sensors | 2 electronic transducers |
| Display Range | 0–99.9 bar |
| Pressure Resolution | 0.1 bar |
| Buffer Valves | 2 |
| Auto-Compensation Valves | 6 (one per station) |
| Timing Control | Digital timer triggered at test initiation |
| Accessories | Temperature-controlled bath (custom-sized for pipe specimens), end-caps with hydraulic coupling |
| Optional | Calibrated reference pressure gauge, 3-channel data logger |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 10036000 |
| Quotation | Upon Request |
| Standard Compliance | ASTM D1693 |
| Fixture Capacity | 10 specimens per test cycle |
| Total Sample Stations | 42 × 10-head sample holders |
| Cutting Tool Set | 5-blade fixture kit |
| Sample Transfer Tool | Dedicated 10-specimen handling tool |
| Test Tubes | 50 pcs borosilicate glass tubes (heat-resistant, Ø33 mm) |
| Notch Depth Gauge | Model 10036005 |
| Temperature Control System | Imported precision water bath |
| Temp. Stability | ±0.05 °C |
| Operating Range | +5 °C to +150 °C |
| Display Resolution | 0.1 °C |
| Bath Volume | 35–41 L |
| Dry-run Protection | Dual-mode (audible/visual alarm + auto power cutoff) |
| Power Switch | Patented recessed, IP65-rated keyboard-integrated switch |
| Drain Valve | Bottom-mounted stainless steel valve |
| Tube Rack | Stainless steel, 42-position, rated to 150 °C |
| Applications | Polymer ESC testing, pharmaceutical stability studies, food packaging integrity assessment, corrosion resistance evaluation, biomaterial compatibility screening |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Distribution Status | Authorized Distributor |
| Import Status | Imported |
| Capacity Options | 200 L, 5000 L |
| Pricing | Upon Request |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Distribution Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 60kV |
| Pricing | Upon Request |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A-Melt |
| Temperature Range | 50–400 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Stability | ±0.2 °C (barrel zone) |
| Barrel ID | 9.55 ±0.007 mm |
| Barrel Material | Nitrided steel, hardness 52–55 HRC |
| Maximum Plunger Travel | 80 mm |
| Cutting Interval | 3–300 s (touch-configurable) |
| Data Points per Test | Up to 100 |
| Display | 5-inch capacitive touchscreen |
| Interface | USB for optional PC software and data export |
| Compliance | ASTM D1238, ISO 1133, GB/T 3682 |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | A-MeP |
| Pricing | Upon Request |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CB-1200 |
| Pricing | Upon Request |
| Compliance | ASTM D1603, ISO 6964, DIN 53582 |
| Max Temperature | 1200 °C |
| Furnace Chamber | Ø30 mm × 250 mm (tubular quartz-lined) |
| Control System | Microprocessor-based digital temperature controller |
| Sample Vessel | High-purity ceramic crucible (combustion boat) |
| Accessories | Quartz tube assembly, metal support stand, gas inlet fittings, exhaust adapter |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Curing Resins |
| Pricing | Upon Request |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | mach32 |
| Pricing | Upon Request |
| Motor Speed | 24,000 rpm |
| Cutting Tool | Tungsten Carbide, Ø8 mm × 35 mm |
| Max. Sample Thickness | 32 mm |
| Brand | ATSFAAR |
|---|---|
| Origin | Italy |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MELTS |
| Pricing | Upon Request |