Industry-specific Instruments
Filter
Showing 781–810 of 2171 results
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GB-KF30010S |
| Price Range | USD 42,000 – 70,000 |
| Filtration Efficiency Range | 0–99.999% |
| Flow Rate Control | 20–100 L/min |
| Pressure Drop Range | 0–1000 Pa |
| Test Particle Sizes | 0.3 µm, 0.5 µm, 5.0 µm |
| Aerosol Sources | DEHS (Di-Ethyl-Hexyl-Sebacate) and 2% NaCl solution |
| Standard Test Area | 100 cm² (customizable per mask geometry) |
| Dimensions | 130 × 75 × 157 cm |
| Weight | 250 kg |
| Power Supply | AC 220 V, 50 Hz |
| Max Power Consumption | <1500 W |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | MIT-Fold |
| Pricing | Available Upon Request |
| Measurement Range | 1–60,000 folds |
| Fold Count Log Scale | 0–4.78 (log₁₀) |
| Tension Adjustment Range | 4.9–14.7 N |
| Folding Angle | ±135° ±2° (left/right) |
| Folding Frequency | 175 ±10 cycles/min |
| Fold Head Slit Widths | 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm (standard: 0.50 mm & 0.75 mm supplied |
| Power Supply | AC 220 V, 50 Hz |
| Dimensions (L×W×H) | 330 × 250 × 400 mm |
| Net Weight | ~37 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Model | N500 Gas Permeability Tester |
| Measurement Range | 0.02–50,000 cm³/m²·day·0.1 MPa (expandable to 600,000 cm³/m²·day·0.1 MPa) |
| Measurement Accuracy | ±0.01 cm³/m²·day·0.1 MPa |
| Temperature Range | 5–50 °C |
| Temperature Control Accuracy | ±0.01 °C |
| Humidity Range | 0 %RH (5–100 %RH optional) |
| Humidity Control Accuracy | ±2 %RH |
| Vacuum Precision | 0.1 Pa |
| Test Chamber Vacuum Level | <20 Pa |
| Test Pressure Range | −0.1 to +0.1 MPa |
| Test Gases | O₂, CO₂, N₂ |
| Max Sample Thickness | ≤2 mm |
| Effective Test Area | 50.24 cm² (Φ80 mm) |
| Power Supply | 220 V AC, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | N600-L |
| Pricing | Upon Request |
| Testing Principles | Gurley (1.23 kPa ± 0.01 kPa), Schopper (1.00 kPa ± 0.01 kPa or 2.50 kPa ± 0.01 kPa), Bentzen (1.47 kPa ± 0.02 kPa) |
| Standards Compliance | SJ/T 10171–2016, GB/T 458–2008, GB/T 36363–2018 |
| Measurement Range | 0.01–2.5 µm/(Pa·s) |
| Air Flow Rate | 0.01–120 mL/min (customizable ranges available) |
| Resolution | 0.001 µm/(Pa·s) |
| Differential Pressure Range | 0–3 kPa |
| Pressure Accuracy | ±0.01 kPa |
| Test Area Options | 6.42 cm² (50 mm × 50 mm) or 10.0 ± 0.2 cm² (60 mm × 100 mm or 50 mm × 50 mm) |
| Test Duration | 10–6000.0 s |
| Sample Conditioning | 24 h at <40 °C and 10–35% RH |
| Chamber Environmental Monitoring | Integrated temperature & humidity sensors |
| Seal Integrity | ≤1.0 mL/h leakage rate |
| Test Volume Capacity | 1 L |
| Dimensions (L×W×H) | 500 mm × 400 mm × 300 mm |
| Power | 100 W |
| Supply | 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GBPI W413 2.0 |
| Quotation | Upon Request |
| Test Principle | Infrared Moisture Detection |
| Standards Compliance | GB/T 26253-2010, ASTM F1249-2013, ISO 15106-2:2005, JIS K7129-2008, YBB 00092003-2015 |
| Measurement Range | 0.002–500 g/(m²·24h) |
| Resolution | 0.001 g/(m²·24h) |
| Temperature Control Range | 15–45 °C |
| Temperature Accuracy | ±0.1 °C |
| Humidity Control Range | 0% RH (dry gas), 30–90% RH, and 100% RH |
| Humidity Accuracy | ±1% RH |
| Test Area | 50.24 cm² |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 specimens per test cycle |
| Carrier Gas | Ultra-high-purity nitrogen (99.999%), ≥0.1 MPa supply pressure, 5–100 mL/min flow rate |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power | 750 W, AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | GBPI Y310 2.0 |
| Price | USD 54,500 (FOB Guangzhou) |
| Test Principle | Coulometric Oxygen Sensor Method |
| Standards Compliance | GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1927, ASTM F1307, ISO 15105-2, DIN 53380-3, JIS K-7126-B, YBB 00082003 |
| Measurement Range | 0.05–1000 cm³/(m²·24 h) (up to 260,000 cm³/(m²·24 h) with auxiliary mask) |
| Resolution | 0.001 cm³/(m²·24 h) |
| Temperature Control Range | 15–45 °C |
| Temperature Stability | ±0.1 °C |
| Test Area | 50.24 cm² (customizable down to 0.785 cm²) |
| Specimen Diameter | Φ100 mm |
| Max Specimen Thickness | ≤3 mm |
| Sample Capacity | 3 independent test chambers |
| Carrier Gas Pressure | ≥0.1 MPa |
| Pneumatic Clamping Pressure | ≥0.3 MPa |
| Power Consumption | 750 W |
| Electrical Supply | AC 220 V, 50 Hz |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | Y310-3 |
| Price Range | USD 14,000 – 72,000 |
| Test Range | 0.02–16,500 cm³/(m²·24h) (film) |
| O₂ Detection Resolution | 0.001 cm³/(m²·24h) |
| Temperature Control | 15–45°C (5–50°C optional) |
| Humidity Control | 0%RH (dry), 30–90%RH, 100%RH |
| Test Area | 50.24 cm² |
| Specimen Size | Ø100 mm |
| Max Thickness | ≤3 mm |
| Sample Capacity | 1–3 independent chambers |
| Carrier Gas Pressure | 0.1–0.2 MPa |
| Gas Inlet | 1/8″ stainless steel tubing |
| Dimensions (W×D×H) | 700×560×370 mm |
| Weight | 100 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GC-4075 |
| Pricing | Upon Request |
| Measurement Method | Dual-Channel Flow Chromatographic Oxygen Adsorption Method |
| Oxygen Uptake Range | 0.05–4 mL/g (coal) |
| Measurement Error | ≤5% |
| Baseline Drift | ≤0.6 mV/hr |
| Carrier Gas Purity | N₂ ≥99.99% |
| Adsorption Gas Purity | O₂ ≥99.99% |
| Sensitivity | ≥10 mV/mL (N₂ carrier, O₂ peak height) |
| Temperature Control Accuracy | ±0.5°C |
| Power Supply | 220 V ±20%, 50 Hz ±0.5 Hz, 500 W |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GDP-C |
| Pricing | Available Upon Request |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-106SD |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% |
| Sample Throughput | 6 samples per run |
| Assay Time | ≤13 minutes per batch |
| Compliance Standard | GB/T 5009.199–2003 |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded MCU with data logging and statistical processing |
| Sample Prep | Integrated dedicated pretreatment kit and single-use reagent cartridges |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-300S |
| Pricing | Upon Request |
| Light Source | High-brightness LED |
| Wavelength | 538 nm |
| Detection Limit | 0.10% (L-hydroxyproline) |
| Measurement Range | 0.00–40.00% (w/w L-hydroxyproline) |
| Accuracy | ±5% |
| Sample Throughput | 20 samples/hour |
| Digestion Time | 15 min (catalytic digestion) |
| Light Source Lifetime | ≥100,000 hours |
| Integrated Optical Design | LED-based solid-state light source acting as both emitter and monochromator |
| Display | Large backlit LCD with Chinese interface |
| Data Output | Built-in thermal printer (sample ID, matrix type, concentration, date, operator ID) |
| Calibration | Zero-point calibration only |
| Brand | Jilin University Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYN-308S |
| Pricing | Available Upon Request |
| Detection Principle | Acetylcholinesterase (AChE) Inhibition Assay |
| Target Analytes | Organophosphorus & Carbamate Pesticides |
| Sample Throughput | 8 samples per run |
| Detection Time | ≤13 minutes per batch |
| Detection Limit | 0.1–3.0 mg/kg |
| Inhibition Rate Range | 0–100% |
| Measurement Accuracy | ±10% (relative to reference standard) |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | GDYQ-100M |
| Price Range | USD 4,200 – 7,000 |
| Function Type | Multi-Analyte (Simultaneous Detection of >30 Parameters) |
| Sample Compatibility | Universal for Solid, Semi-Solid, and Liquid Food Matrices |
| Wavelength Range | 400–630 nm |
| Assay Time | 3–20 minutes per test |
| Brand | Jilin University–Xiaotian’e |
|---|---|
| Model | GDYQ-107S |
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | PRC |
| Detection Limit | 25.0 mg/kg |
| Measurement Range | 0.0–2000.0 mg/kg |
| Accuracy | ±5% |
| Analysis Time | ≤35 min per sample |
| Sample Processing | Integrated proprietary pretreatment kit and reagents |
| Brand | Jilin University & Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | GDYQ-110SH |
| Pricing | Available Upon Request |
| Detection Limit | Stale rice ≥3 years old |
| Measurement Range | 1–3 years storage duration |
| Accuracy | ±5% relative to reference standard methods |
| Brand | Jida Xiaotianshe |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-201SQ2 |
| Pricing | Available Upon Request |
| Detection Principle | Acetylacetone Colorimetric Method |
| Detection Limit | 1.0 mg/kg |
| Measurement Range | 0.0–100.0 mg/kg |
| Accuracy | ±2% |
| Analysis Time | ≤10 min per sample |
| Display | Backlit LCD with Chinese UI |
| Control System | Embedded Microcontroller |
| Data Functions | Measurement logging, statistical processing, parameter setting, help system, USB/RS232 communication |
| Sample Prep | Dedicated pretreatment kit + single-use reagent cartridges |
| Compliance Basis | Modified GB/T 5009.49 & GB 5009.276 methods |
| Brand | Jida Xiaotian’e |
|---|---|
| Origin | Jilin, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GDYQ-5000S |
| Function Type | Single-Analyte Dedicated Instrument |
| Sample Type | Sesame Oil Only |
| Detection Time | 20 min |
| Quantification Range | 0.0–100.0% |
| Detection Limit | 3.0% |
| Accuracy | ±2% |
| Brand | Genphon |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Manufacture | Domestic (China) |
| Model | GF-WSW-3 |
| Filter Membrane Diameter | Φ47 mm or Φ50 mm |
| Effective Filtration Area | 40 mm diameter |
| Filter Cup Capacity | 150 mL (250 mL optional) |
| Number of Filtration Heads | 1 / 3 / 6 units |
| Detection Method | Membrane Filtration |
| Vacuum Source | External Vacuum Pump Required |
| Filtration Rate | 100 mL per 15 s (with membrane installed) |
| Sterilization Methods | Autoclavable (moist heat, 121°C, 30 min) and flame-sterilizable |
| Filtration Head Design | Modular, fully detachable and reassemblable |
| Brand | Geotech (UK) |
|---|---|
| Origin | USA |
| Model | EA 5K (GA 5000) |
| Measurement Range | 0–10,000 ppm |
| Response Time | ≤10 s |
| Principle | Electrochemical sensing, NDIR infrared analysis, H₂-compensated CO detection |
| Certifications | ATEX II 2G Ex ib IIA T1 Gb, IECEx, UKAS ISO/IEC 17025 (Ref. No. 4533), MCERTS (under application), CSA |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar Automatic |
| Accuracy | ±0.0001 °C |
| Repeatability | ±0.002 °C |
| Measurement Range | −1.5000 °C to 0.0000 °C |
| Sample Volume | 2.0–2.5 mL |
| Throughput | 40 samples/hour |
| Dimensions (W×H×D) | 44×44×20 cm |
| Test Head Height | 24 cm |
| Net Weight | 14.6 kg |
| Power Supply | 230 V, 50–60 Hz, 180 W + 12 V DC |
| Interface | RS232 |
| Sample Capacity | 12-position automated carousel |
| Compliance | ISO/DIS 5764 |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | CryoStar I |
| Measurement Range | 0.0000 to −1.5000 °C |
| Resolution | 0.0001 °C (0.1 m°C) |
| Accuracy | ±0.002 °C (repeatability) |
| Sample Volume | 2.0–2.5 mL |
| Throughput | up to 40 samples/hour (typical: 30 samples/hour) |
| Cooling Time | ≤15 min to operational temperature |
| Display | Full-color LCD touchscreen |
| Data Interfaces | RS232, 2× USB (U-disk data export) |
| Power Supply | 220 V / 50 Hz, 180 W |
| Dimensions | 29 × 33 × 34 cm |
| Weight | 8.7 kg |
| Brand | GERBER |
|---|---|
| Origin | Germany |
| Model | Nova Safety |
| Max Speed | 1350 rpm |
| Relative Centrifugal Acceleration (RCF) | 350 × g |
| Capacity | 8 tubes |
| Temperature Control | 65 °C (heated) |
| Timer | Digital display |
| Safety Features | Automatic lid lock, electronic brake (<8 s stop time) |
| Dimensions (L×W×H) | 470 × 380 × 230 mm |
| Weight | 13.2 kg |
| Voltage | 230 V, 50 Hz |
| Power | 450 W |
| Brand | Funke |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | SuperVario-N |
| Price | Upon Request |
| Brand | Gerhardt |
|---|---|
| Origin | Germany |
| Manufacturer | C. Gerhardt GmbH & Co. KG |
| Model | Fibretherm FT12 |
| Sample Capacity | 1–12 samples per batch |
| Heating System | Programmable microcrystalline ceramic heater |
| Reagent Dispensing | Automated acid/alkali/water addition and waste drainage |
| Filtration | Pneumatically actuated high-precision FibreBag® filtration system |
| Control Interface | Onboard touchscreen with storage for up to 10 preprogrammed methods |
| Safety Features | Closed-system operation, acoustic and visual error alerts, automatic cooling water monitoring |
| Power Supply | 230 V AC, 50 Hz |
| Rated Power | 1900 W |
| Dimensions (W × D × H) | 330 × 650 × 860 mm |
| Weight | 42 kg |
| Cooling Water Requirement | 5 L/min (on-demand) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RD-8 |
| Detection Target | Milk Powder Moisture Content |
| Automation Level | Fully Automatic |
| Analysis Speed | 250 samples per hour (not per minute — corrected per industry standard for gravimetric moisture analyzers) |
| Sample Capacity | 8 positions |
| Temperature Range | Adjustable up to 110 °C |
| Temperature Stability | ±0.3 °C |
| Air Flow Rate | 33 mL/min at 87 °C |
| Compressed Air Requirement | 2.5–7.5 bar |
| Power Supply | 230 V / 115 V, 520 W |
| Dimensions | 185 mm × 240 mm × 450 mm |
| Weight | 9.5 kg |
| Repeatability | <1% RSD |
| Accuracy | <1% deviation vs. reference oven-drying method |
| Compliance | ISO 5537, IDF 26, equivalent to GB/T 5009.3 (Chinese National Standard) |
| Brand | Glatt |
|---|---|
| Origin | Germany |
| Model | TMG |
| Working Vessel Gross Volume | 1–6 dm³ |
| Working Volume Range | 0.3–4.5 dm³ |
| Rotor Diameter | 170–230 mm |
| Rotor Speed (infinitely variable) | 50–1000 rpm |
| Chopper Speed (infinitely variable) | 300–3000 rpm |
| Motor Power | 1.1 kW |
| Dimensions (L×W×H) | 900 × 515 × 675 mm |
| Weight (empty unit) | ~140 kg |
| Brand | GMI (UK) |
|---|---|
| Origin | United Kingdom |
| Model | PS1 |
| Gas Detection | O₂ (0–25% vol, 0.1% res), H₂S (0–100 ppm, 1 ppm res), CO (0–500 ppm, 1 ppm res), SO₂ (0–20 ppm, 0.1 ppm res) |
| Display | Backlit LCD |
| Protection Rating | IP67 |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Dimensions | 85 × 55 × 29 mm |
| Weight | 86 g |
| Power | 3.6 V lithium-thionyl chloride battery |
| Alarm Types | Visual (360° high-brightness LED), Audible (95 dB), Vibration |
| Certifications | IECEx Ex ia IIC T4 Ga, ATEX Ex II 1G Ex ia IIC T4 Ga, UL913 Class I Div 1 Groups A–D T4, CE, MED 96/98/EC, CSA Class I Div 1 Groups A–D T4 (pending) |
| Brand | GMI (UK) |
|---|---|
| Origin | United Kingdom |
| Model | T.ex-O2 |
| Detection Principle | Electrochemical Sensor |
| Gas Measured | O₂ |
| Range | 0–25% vol |
| Resolution | 0.1% vol |
| Operating Temperature | −20 °C to +50 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Display | Backlit high-contrast LCD (analog bar + digital readout) |
| Audible Alarm | 95 dB at 10 cm, 85 dB at 30 cm |
| Visual Alarm | Dual LED flash indicators |
| Vibration Alert | Integrated haptic feedback |
| Enclosure Material | Impact-resistant polypropylene |
| Ingress Protection | IP67 |
| Certifications | ATEX II 1 G Ex ia IIC T4, UL 913 Class I, Div 1, Groups A/B/C/D, MED |
| Battery | Rechargeable Li-ion, 3-year typical service life |
| Dimensions | 85 × 55 × 29 mm |
| Weight | 81 g (O₂ configuration) |
| Data Logging | Standard internal memory with timestamped records |
| Connectivity | USB interface for data download and calibration verification |
| Alarm Modes | STEL (Short-Term Exposure Limit), TWA (Time-Weighted Average), Peak, Lockable Alarm |
| Pump | Integrated micro-diaphragm sampling pump |
| Self-Test | Power-on diagnostic sequence with sensor and circuit validation |
| Mounting | Clip-on design for collar or vest placement near breathing zone |
| Brand | Goettfert |
|---|---|
| Country of Origin | Germany |
| Model | VISCO-ELASTOGRAPH |
| Temperature Range | 5–230 °C |
| Temp. Resolution | 0.01 °C |
| Temp. Stability | < ±0.2 °C over time |
| Temp. Uniformity (across cavity) | < 0.5 °C |
| Oscillation Frequency | 0.01–100 Hz |
| Angular Amplitude | ±0.01°–±90° |
| Relaxation Angle Range | 0–90° |
| Angular Resolution | 0.001° |
| Max. Torque | 20 Nm |
| Max. Normal Force | 10 kN |
| Closing Force | 12 kN |
| Dimensions (H×W×D) | 1145 × 540 × 410 mm |
| Weight | 175 kg |
| Brand | GOTECH TESTING MACHINES CO., LTD. |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | GT-6011-B |
| Pricing | Available Upon Request |