| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | MIA 2020 |
| Alcohol Strength by Volume (ASV) Range | 0.1–99.9 % vol (BASIC) / 0.050–99.980 % vol (Premium) |
| ASV Accuracy | ±0.1 % vol (BASIC) / ±0.005 % vol (Premium) |
| ASV Repeatability | ±0.1 % vol at 15 °C and 25 °C (BASIC) / ±0.01 % vol at 15 °C and 25 °C (Premium) |
| Density Range | 0.5000–2.2500 g/cm³ (d₂₀/₂₀) |
| Density Resolution | 0.0001 g/cm³ (BASIC) / 0.00001 g/cm³ (Premium) |
| Density Repeatability | ±0.0002 g/cm³ (BASIC) / ±0.00002 g/cm³ (Premium) |
| Temperature Sensor | Pt100, 1/3 DIN class |
| Temp. Resolution | 0.05 °C |
| Temp. Repeatability | ±0.05 °C (10–30 °C) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Power Consumption | 10 VA |
| Operating Ambient | 10–30 °C (recommended: 15–25 °C) |
| Dimensions (L×D×H) | 210 × 370 × 380 mm |
| Net Weight | 8.5 kg |
| Interface | RS232 I/O |
| Measurement Cycle Time | ≤6 s |
| Calibration | Fully automated internal calibration |
| Standard Accessories | Power supply unit, waterproof interchangeable mass/volume hydrometer set (stainless steel suspension wire, Ø ≤ 0.2 mm), certified alcohol reference standards, double-walled glass measuring cylinder |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | NEB-40 / NEB-50 / NEB-91 |
| Temperature Range | −35 to +90 °C / −40 to +90 °C / −40 to +150 °C |
| Flow Rate | 1–20 L/min |
| Temperature Stability | ±0.01–±0.05 °C / ±0.05–±0.1 °C / ±0.05–±0.2 °C |
| Heating Power | 2.7 / 6 / 18 kW |
| Cooling Power (at 20 °C) | 1.2 / 7.5 / 11 kW |
| Pump Flow Range | 16–40 / 35–76 / 26–80 L/min |
| Pump Pressure | 0.3–1.7 / 0.48–3.2 / 0.5–3.0 bar |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | NLK |
| Compliance | DIN EN 459-2 |
| Measurement Principle | Calorimetric monitoring of heat evolution during lime slaking (wet digestion) |
| Data Acquisition | Dual/multi-point temperature sensing via calibrated thermistors or Pt100 sensors |
| Thermal Isolation | Vacuum-insulated Dewar vessels |
| Output Format | CSV export |
| LIS/LIMS Integration | Yes |
| Calibration | Two-point or multi-point temperature sensor calibration |
| Reporting Parameters | T₀, tₘₐₓ, Tₘₐₓ, T′ₘₐₓ, tᵤ₈₀, Tᵤ₈₀, T₆₀, T₁₀, T₄₀, R-value, max rotational speed |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Super Alcomat |
| Alcohol by Volume (ABV) Range | 0.13–98.98% ASV |
| ABV Resolution | 0.01% ASV |
| ABV Repeatability | ±0.03% (at 15–25 °C) |
| Density Range | 0.5000–2.2500 g/cm³ |
| Density Repeatability | ±0.00005 g/cm³ |
| Operating Temperature | 10–30 °C (optimal at 15–23 °C) |
| Display | Backlit LCD with multi-parameter readout |
| Interface | Waterproof keypad |
| Output | RS-232 for optional thermal printer |
| Compliant Standards | ASTM D1120, ISO 3696 (Grade 3 water), OIV Rec. 22/2007, EU Regulation No 2019/1793 (wine analysis) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Super DEE |
| Instrument Type | Dedicated Alcohol & Volatile Acidity Analyzer for Wine and Beverages |
| Measurement Time | ~3–4 min for 100 mL red wine |
| Alcohol by Volume (ABV) | 0–12% vol |
| pH Range | 0–14 |
| Dimensions (L × W × H) | 35 × 41 × 27 cm |
| Weight | 38 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | UPLAB |
| Wavelength Range | 320–1100 nm (VIS), 190–1100 nm (UV-VIS & UV-VIS AUTO) |
| Wavelength Accuracy | ±2.0 nm (VIS/UV-VIS), ±0.5 nm (UV-VIS AUTO) |
| Wavelength Repeatability | 1 nm (VIS/UV-VIS), 0.2 nm (UV-VIS AUTO) |
| Spectral Bandwidth | 2 nm (1, 4, 5 nm optional) |
| Photometric Accuracy | ±0.5% T (0–100% T), ±0.002 A (0–0.5 A), ±0.004 A (0.5–1 A) |
| Photometric Repeatability | 0.3% T (VIS/UV-VIS), 0.2% T (UV-VIS AUTO) |
| Stray Light | ≤0.1% T (NaI at 220 nm |
| 0% T Stability | 0.2% T / 30 min |
| 100% T Stability | 0.001 A / 30 min (at 500 nm, post thermal equilibration) |
| Detector | Silicon photodiode |
| Light Sources | Tungsten halogen lamp (VIS), Deuterium lamp (UV-VIS & UV-VIS AUTO) |
| Display | 16×2 LCD (VIS/UV-VIS), 6-inch high-brightness blue-backlit LCD (UV-VIS AUTO) |
| Operating Modes | Transmittance (T), Absorbance (A), Concentration (C), Kinetics (E) |
| Data Output | USB interface, printer support, PC export via UPSoft software |
| Dimensions | 530 × 410 × 210 mm |
| Weight | 15–18 kg (model-dependent) |
| Power Supply | 220–230 V AC, 50 Hz |
| Power Consumption | 100–140 W |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VISCO 370 |
| Measurement Principle | Capillary Viscometry (Ostwald/Ubbelohde/Cannon-Fenske) |
| Temperature Range | –40 °C to +150 °C |
| Temperature Stability | ±0.01 °C (DT-series bath) |
| Timing Resolution | 0.01 s |
| Timing Accuracy | ±0.01% (±1 digit) |
| Kinematic Viscosity Range | 0.35–1800 mm²/s (cSt) under pressure mode |
| Capillary Compatibility | Ubbelohde, Cannon-Fenske, micro-Ostwald, micro-Ubbelohde, dilution-type, and thermal conductivity viscometers |
| Calibration | ISO/ASTM-traceable capillaries with certified constants to four decimal places |
| Module Scalability | Up to 8 independent measurement units |
| Cleaning Options | Single- or dual-solvent automated rinsing with programmable solvent volume, rinse duration, and drying time |
| Software | WinVisco 4 (multi-language: EN/DE/FR/ES/CN), supports ASTM D445, ISO 3104, ISO 1628, USP <911>, and GLP-compliant audit trail |
| Data Output | PDF & CSV reports with timestamped filenames, full traceability, and user-level access control (3-tier permissions) |
| Compliance | Fully compliant with ASTM D445, ISO 3104, ISO 1628-1, DIN 51562, and FDA 21 CFR Part 11 (when configured with electronic signature and audit trail enabled) |
| Brand | Chinyee |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | APD500A |
| Pricing | Available Upon Request |
| Application | Fuel Oil, Crude Oil Residues, FCC Slurry Oil, Coker Drum Effluents |
| Sample Limitations | Not suitable for samples containing non-toluene-soluble solids (e.g., sludge), high-melting-point paraffins (>50 °C), or natural bitumens |
| Measurement Range | 0.5–15 wt% |
| Repeatability | ±2% RSD |
| Measurement Time | 30 s (excluding sample prep) |
| Optical Method | Dual-wavelength photometry using interference filters |
| Light Source | Tungsten-halogen lamp |
| Wavelengths | 750 nm and 880 nm |
| Detector | Silicon photodiode |
| Interface | RS-232C |
| Power Supply | 220 V, 50/60 Hz |
| Dimensions (W×D×H) | 460 × 165 × 635 mm |
| Weight | 25 kg |
| Output | Integrated thermal printer + RS-232C port |
| Safety Certification | CE-compliant |
| Brand | CHINYEE |
|---|---|
| Origin | Japan |
| Model | NT-6100A |
| Compliance | USP <711>, <724>, <1092> |
| Apparatus Type | Paddle (App. 2) |
| Vessel Capacity | 900–1000 mL |
| Temperature Control Range | 30–45 °C (±0.2 °C stability) |
| Rotation Speed | 25–250 rpm (±1 rpm accuracy) |
| Number of Vessels | 6 |
| Interface | RS-232C, optional USB/Ethernet upgrade |
| Calibration Support | USP Calibrator Tablets (Prednisone, Salicylic Acid), mechanical verification tools included |
| Drive Architecture | Monolithic shaft coupling with one-touch bath cover release |
| Vessel Positioning | Centered alignment via precision-machined guide rails |
| Traceability | Individual serialized vessels, paddles, and shafts |
| Brand | CHINYEE |
|---|---|
| Origin | Japan |
| Model | RX-620 |
| Measurement Principle | Energy-Dispersive X-ray Fluorescence (ED-XRF) |
| Standards Compliance | ASTM D4294, ISO 8754, JIS K2541, JIS B7995 |
| Sample Types | Kerosene, Naphtha, Diesel, Crude Oil, Heavy Fuel Oil |
| Measurement Range | 0.003–6.00 wt% S |
| Sample Volume | 3–5 mL |
| Detection Limit | 5–200 ppm |
| C/H Ratio Correction | 0.003 wt%/unit C/H ratio (at 1 wt% S) |
| Calibration | Auto 1-, 2-, or 3-point |
| Sample Changer | 12-position turret with acrylic dust cover |
| Detector System | Single reusable PTFE sample cup with polyester film window (sole consumable) |
| X-ray Leakage | ≤0.6 µSv/h at instrument surface |
| Safety | Interlocked mechanical shutter and door sensor |
| Display | 4-line × 20-character LCD |
| Printer | Integrated dot-matrix printer |
| Interface | RS-232C (1 port) |
| Power | DC 12 V (vehicle battery compatible) |
| Weight | 12 kg |
| Enclosure | Integrated console with display, keypad, and printer |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SP / HYP / HWP |
| Pricing | Available Upon Request |
| Brand | Choppin |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Alveolab |
| Price Range | USD 68,000 – 109,000 |
| Brand | Chuanyi Instruments |
|---|---|
| Origin | Hangzhou, Zhejiang, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | ZW-808A |
| Power Supply | AC 220 V (±10%), 50 Hz (±2%) |
| Rated Power | 60 W |
| Speed Range | 0–300 ±5 rpm |
| Dimensions (W×D×H) | 26 × 26 × 18 cm |
| Weight | 10 kg |
| Filter Compatibility | 0.22 µm or 0.45 µm × 47 mm membrane filters |
| Noise Level | <50 dB(A) |
| Material | ASTM A240 Type 304 stainless steel (mirror-finished) |
| Safety | IPX4-rated sealed interfaces, footswitch with aviation-grade waterproof connector (<24 V DC control), auto-stop upon pump head opening |
| Brand | Chuanyu Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ZW-2008 |
| Power Supply | 220 V / 50 Hz |
| Rated Power | 120 W |
| Rotational Speed Range | 0–300 rpm |
| Height of Suspension Assembly | 35 cm |
| Weight | 15 kg |
| Filter Membrane Options | 0.22 µm × 47 mm or 0.45 µm × 47 mm |
| Flow Control | Four Fixed-Speed Settings (40, 60, 160, 240 rpm) |
| Construction Material | ASTM A240 Grade 304 Stainless Steel |
| Brand | CID Bio-Science |
|---|---|
| Origin | USA |
| Model | CI-710S |
| Spectral Range | 360–1100 nm |
| Measurement Modes | Reflectance, Transmittance, Absorbance |
| Compliance | Designed for GLP-aligned field phenotyping workflows |
| Brand | CINRG |
|---|---|
| Origin | Canada |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CS-APC-2 |
| Product Category | Laboratory Instrument |
| Test Parameter | Contaminant Particles |
| Compliance | ASTM D7647-10 |
| Sample Processing Time | 4–5 min/sample |
| Solvent Consumption | 40 mL/sample |
| Autosampler Capacity | 102 samples (104-position tray |
| Sensor Model | KLOTZ LDS 45/50 Laser Sensor |
| Measurement Range | 1.5 µm – 100 µm |
| Flow Rate | 30 mL/min (calibrated) |
| Detection Thresholds | 25,000 particles/mL at ≥4 µm (neat oil), 50,000 particles/mL at ≥4 µm (1:1 dilution) |
| Volume Accuracy | ±2% (pre-dilution) |
| Customizable Reporting | User-defined pass/fail limits at 4 µm, 6 µm, and 14 µm |
| Data Export Fields | Solvent blank count, sample volume, dilution ratio, raw particle counts per channel |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CL440 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CM825-MDD |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | CS100 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | DA20 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MC760 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MC960 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | FR700 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GL200 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Distributor Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IDM 800 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Country of Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MC1000 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MDS1000 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MM200 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MPA2 |
| Pricing | Upon Request |
| Brand | CK |
|---|---|
| Origin | Germany |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | MPA2 PRO |
| Pricing | Upon Request |