| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | PD1120CC |
| Standard Compliance | ASTM D1120, SAE J1704 |
| Automation Level | Fully Automated |
| Test Duration | 8–15 min per sample |
| Output | Permanent thermal print + network-enabled PDF export |
| Regulatory Context | Designed for GLP-compliant laboratories |
| Application Scope | Engine coolant and brake fluid equilibrium boiling point (EBP) determination |
| Brand | PILODIST |
|---|---|
| Origin | Germany |
| Model | PD300CC |
| Max. Distillation Temperature | 400 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | 0–25 °C |
| Distillation Rate | 180–360 mL/h |
| Volume Detection Range | 1–200 mL |
| Volume Resolution | 0.1 mL |
| Compliance | ASTM D1160 |
| Control Interface | 15.6″ IP65-rated touchscreen with integrated thermal printer |
| Data Export Formats | PDF, XLS, CSV, TXT |
| Safety | Dual independent heating safety circuits, auto-termination on AET limit, bath temperature limit, flask temperature limit, distillate volume limit, pressure drop, or flask fracture detection |
| Optional Accessory | 4-position automated fraction collector |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | QUICKDIST 500 CC, QUICKDIST 500M |
| Operating Temperature (Flask) | Up to 350°C |
| Final Boiling Point (AET) | Up to 420°C |
| Operating Pressure | Atmospheric to <1 mbar (vacuum) |
| Theoretical Plates | Up to 60 |
| Flask Volumes | 100 mL, 500 mL, 1 L, 2 L |
| Feed Capacity | Up to 60% of flask volume |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | SP200 |
| Vacuum Range | 1–0.001 mbar |
| Temperature Control Accuracy | ±0.01 °C |
| Construction Options | All-Glass or Glass-Metal Hybrid |
| Evaporator Type | Double-Jacketed Glass Rotating Film Evaporator |
| Condenser | Integrated Helical Coil Internal Condenser |
| Display | LED Digital Readouts for Film Speed, Vacuum Pressure, and Temperature |
| Application Scope | Lab-Scale & Pilot-Scale Molecular Distillation of Thermolabile, High-Boiling, High-Viscosity, or High-Molecular-Weight Organic Compounds |
| Compliance | Designed to Support ASTM D2892 / D5236, ISO 9145, and GLP/GMP-aligned documentation workflows |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | TF 650 |
| Operating Temperature Range | up to 250 °C |
| Operating Pressure Range | 0.1–10 mbar (absolute) |
| Feed Rate | 0.5–10 L/h |
| Evaporation Area | 6.5 dm² |
| Construction Material | High-grade stainless steel (SS 316L standard) |
| Dimensions (W × H × D) | 1.20 × 1.80 × 0.60 m |
| Ultimate Vacuum Capability | ≤0.001 mbar (with compatible vacuum system) |
| Brand | Pilodist |
|---|---|
| Origin | Germany |
| Model | VLE 110 |
| Operating Pressure Range | Vacuum to Overpressure (Configurable) |
| Temperature Range | Ambient to 250 °C |
| Temperature Accuracy | ±0.1 °C |
| Cold Bath Temperature Range | −20 °C to 100 °C |
| Distillation Rate | 30 drops/min |
| Sample Volume Capacity | 100 mL |
| Volume Resolution | 1 mL |
| Brand | Pinzhichuangsi |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | XR-14 |
| Price | USD 2,600 (FOB Beijing) |
| Stirring Speed | 14,000 rpm ± 200 rpm |
| Speed Range | 2,000–24,000 rpm (adjustable) |
| Speed Resolution | 1 rpm |
| Speed Accuracy | ≤ 0.1% FS |
| Sample Container | Cylindrical borosilicate glass vessel (ID 58 mm, OD 63 mm, H > 100 mm) |
| Stirrer Discs | Two interchangeable discs — natural rubber latex disc (Ø 20.83 ± 0.03 mm, t 1.57 ± 0.05 mm) |
| Stirrer Shaft Tip Diameter | 6.3 mm |
| Operating Ambient | 10–40 °C, < 85% RH |
| Power Supply | 220 V ±10%, 50 Hz, 1500 W |
| Dimensions (W×D×H) | 400 × 350 × 720 mm |
| Cooling System | Integrated recirculating coolant pump |
| Display | LED digital readout via frequency converter interface |
| Compliance | GB/T 8301–2008, SH/T 1151–1998 |
| Brand | OEM / Private Label |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 620 (FOB) |
| Measurement Range | 0–100 kg/cm² (0.1 kg/cm² resolution) |
| Hydraulic Oil Displacement Rate | 170 ± 15 mL/min |
| Display Units | kg, N, lb |
| Dimensions (W×D×H) | 450 × 430 × 520 mm |
| Sensor Accuracy | ±1 kPa |
| Compliance | ASTM D774, ISO 2758, TAPPI T403, GB/T 454 |
| Brand | SDLATLAS |
|---|---|
| Model | D394B |
| Roller Width | 450 mm |
| Roller Diameter | 125 mm |
| Roller Hardness | 70 ± 2 Shore A |
| Drive Speed | Fixed at 10 rpm |
| Trough Capacity | ~1000 mL |
| Actuation | Pneumatic Load Control |
| Safety Interlocks | Integrated |
| Compatibility | Optional Air Compressor Supply |
| Integration | Designed for inline coupling with Mini Dryer or Stenter Frame |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CFC |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | GPC-QC |
| Operating Temperature Range | 140–160 °C |
| Analysis Time per Sample (incl. dissolution) | ≤30 min |
| Detection | IR5 Selective Infrared Detector (C–H stretch, 3.42 µm) |
| Concentration Sensitivity | 0.125 mg/mL (S/N ≥60) |
| Optional Detectors | Dual Capillary Viscometer (IV), IR4 |
| Column Configuration | Pre-packed High-Throughput GPC Columns (macroporous crosslinked polystyrene/divinylbenzene, calibrated for polyolefins) |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11–ready data handling |
| Sample Throughput | Up to 24 samples unattended |
| Dimensions | Benchtop (W × D × H: 750 × 600 × 550 mm) |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PREP mc2 |
| Pricing | Upon Request |
| Brand | Polymer Char |
|---|---|
| Origin | Spain |
| Model | TREF |
| Sample Capacity | 5 positions |
| Analysis Time per Sample | ~6 hours (standard conditions) |
| Detection | IR4 Infrared Detector (standard), optional Multi-Angle Light Scattering (MALS) and Capillary Viscometer |
| Minimum Operating Temperature | –20 °C |
| Software-Controlled Automation | Full remote operation and diagnostic capability |
| Solvent Handling | Closed-loop, minimal solvent consumption, no manual solvent contact required |
| Upgrade Path | Compatible with CRYSTAF-TREF hyphenated configuration |
| Compliance | Designed for GLP-compliant laboratories |
| Key | Brand: POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model Series | JDS05 |
| Maximum Biaxial Force per Axis | 500 N |
| Force Resolution | 1/10,000 of full scale |
| Optical Magnification | up to 8 pixels/µm |
| Imaging System | Dual-mode illumination (transmitted + movable reflective), continuous zoom long-focus lens |
| Software | Proprietary textile mechanics analysis suite |
| Compliance | Designed for ASTM D5035, ISO 13934-1, ISO 13935-1, GB/T 3923.1, and custom method implementation |
| Computer Interface | USB + RS-232 (COM port required) |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model Series | JQ03 |
| Compliance | ASTM D3822, ISO 5079, GB/T 14337, GB/T 14338, USP <1061> (Fiber Mechanical Testing Guidance) |
| Force Range | 0.1 mN – 500 mN (selectable full-scale ranges) |
| Displacement Resolution | ≤ 0.1 µm |
| Strain Rate Control | 0.01 – 500 mm/min (programmable) |
| Integrated Imaging | 10×–100× motorized zoom optical module with real-time diameter/length measurement |
| Data Acquisition | 10 kHz sampling rate, synchronized force–displacement–image stream |
| Software | POWEREACH FiberTest v4.2 (GLP-compliant audit trail, 21 CFR Part 11 optional module) |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JQL04 |
| Max. Measurable Fiber Length | 120 mm |
| Min. Detectable Fiber Diameter | 1 µm |
| Scanning Resolution | 8 pixels/µm |
| High-Speed Imaging | 100 fps |
| Tensile Speed Control | Adjustable |
| Fiber Cross-Sectional & Diameter Variability Analysis | Yes |
| Compliance | ASTM D3822, ISO 5079, GB/T 14337 |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | JSF08 |
| Force Sensor | 0.9807 N & 4.903 N (NMB Japan), resolution: 0.01% FS |
| Linear Guide Travel | 25 mm, pitch: 0.25 mm |
| Motor Step Resolution | 0.1125°, positional accuracy: 0.068 µm |
| Zoom Stereo Optical System | 0.7×–4.5× |
| Non-contact Optical Imaging Resolution | 8 px/µm |
| Fiber Gauge Length | 0.8 mm |
| CCD | 1.3 MP monochrome digital sensor, 600 TV lines |
| Environmental Control | Optional regulated temperature/humidity chamber integration |
| Software Modules | Creep-relaxation feedback control, side-view imaging, top-view imaging & capture, tensile test logging, in-situ strain mapping |
| Brand | POWEREACH |
|---|---|
| Model | JWQ06 |
| Application | Textile Fiber Mechanical Testing |
| Measurement Principle | Controlled Oscillatory Bending under Tension |
| Sample Type | Individual Filaments (Aramid, Carbon, Glass, UHMWPE) |
| Adjustable Bend Radius | Yes |
| Environmental Operation | Ambient to Elevated/Low Temperatures |
| Tension Monitoring | Real-time Dynamic Tension Measurement during Bending Cycles |
| Control Interface | PC-based Software with RS232/USB Connectivity |
| Compliance Context | ASTM D3822, ISO 5079, GB/T 14337, ISO 1973 (adapted for bending fatigue extension) |
| Software Features | Cycle Counting, Load-Time Curve Logging, Pre-tension Calibration, Angle & Frequency Parameterization |
| Brand | Prema |
|---|---|
| Origin | Taiwan |
| Model | HD-400 |
| Motor | DC 350 W |
| Speed Range | 0–7000 rpm |
| Maximum Torque | 5.4 kg·cm |
| Weight | 18 kg |
| Shaft Material | Full Stainless Steel (AISI 316) |
| Drive System | Continuously Variable Electronic Speed Control |
| Safety Features | Integrated Ammeter, Thermal Fuse Protection |
| Surface Finish | Chemically Resistant Epoxy Coating |
| Brand | Prema |
|---|---|
| Origin | Taiwan |
| Model | HM-300 |
| Motor | DC 550 W |
| Speed Range | 0–12,000 rpm |
| Capacity | 0.1–2 L |
| Weight | 10 kg |
| Power Supply | 220 V, 50 Hz |
| Drive Shaft Material | SUS316 Stainless Steel |
| Speed Control | Continuous (Stepless), Digital Keypad Input with Real-Time RPM Display |
| Timer Function | 00:00–99:59 (hh:mm), Auto-Stop with Audible Alert |
| Safety Features | Built-in Fuse, Current Monitoring Indicator, Torque Compensation System, Obstruction Detection & Error Display |
| Construction | Chemically Resistant Coating, Vibration-Damped Chassis, Spring-Loaded Vertical Adjustment Mechanism (HM-300/310 variant) |
| Brand | Prescott |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Rheoline MDR |
| Price | Upon Request |
| Standard Compliance | ISO 6502, ASTM D5289 |
| Oscillation Frequency | 1.67 Hz |
| Oscillation Amplitude Options | 0.5° (standard), 1.0° or 3.0° (optional) |
| Temperature Range | 35–250 °C |
| Temperature Control | Digital PID |
| Torque Units | in·lb, dN·m |
| Temperature Units | °C, °F |
| Pressure Units (optional) | psi, kg/cm² |
| Time Format | min/sec, min/decimal, sec |
| Output Parameters | Elastic Modulus (G′), Viscous Modulus (G″), Tan δ, Curing Rate, Cavity Pressure (optional) |
| Data Storage | Microsoft Access or SQL database |
| Optional Accessories | Programmable multi-zone heating, Eccentric oscillating die, Cavity pressure transducer, Automated sample loader, Volumetric sample cutter |
| Software | Windows-based proprietary test platform with SPC module (optional), GLP/GMP-compliant audit trail support |
| Key Parameters | Brand: Pinzhichuangsi |
|---|---|
| Origin | Beijing, China |
| Model | XR-14-2 |
| Speed Range | 2000–20,000 rpm |
| Nominal Test Speed | 14,000 ± 200 rpm |
| Speed Accuracy | ≤0.1% |
| Resolution | 1 rpm |
| Display | LED |
| Power Supply | 220 VAC, 50 Hz, 2000 VA |
| Dimensions (W×D×H) | 400 × 350 × 740 mm |
| Net Weight | ~30 kg |
| Operating Environment | 10–40 °C, <85% RH |
| Continuous Operation | ≥60 min |
| Stirring Disk (Natural Latex) | Ø20.83 ± 0.03 mm × 1.57 ± 0.05 mm |
| Stirring Disk (Synthetic Latex) | Ø36.12 ± 0.03 mm × 1.58 ± 0.05 mm |
| Sample Container | Height 130 ± 2 mm, ID 58 ± 2 mm |
| Compliance | ISO 35 |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Pull-GP4-1000 |
| Capacity | 1 L |
| Material | Stainless Steel (AISI 316 or equivalent) |
| Design Pressure | 4 MPa |
| Compliance | GB 8570–2008 “Sampling of Laboratory Samples of Anhydrous Liquid Ammonia” |
| Pricing | USD 450 (FOB China, subject to quotation) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PLD-269C |
| Pricing | Available Upon Request |
| Maximum Penetration Range | 75 mm |
| Penetration Resolution | ±0.1 mm |
| Timing Accuracy | 0.1 s |
| Standard Cone | Compliant with GB/T 269 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PLD-3535D |
| Temperature Range | 60 °C to −38 °C |
| Temperature Resolution | 0.1 °C |
| Sample Channels | 2 |
| Cooling Method | Air-Cooled Compressor System |
| Detection Method | Top-Mounted Photoelectric Liquid-Level Sensor with Micro-Tilt Mechanism |
| Temperature Interval Setting | 1–10 °C (user-defined) |
| Power Supply | AC 220 V ±10%, 50 Hz ±2 Hz |
| Display | 128×64 Dot-Matrix LCD (Chinese Characters) |
| Printer | 20-Column Dot-Matrix Thermal Printer (Chinese Characters) |
| Compliance Standard | GB/T 510 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Detection Principle | Light Obscuration (LO) / Single-Particle Optical Sizing (SPOS) |
| Laser Source | Dual-narrow-beam laser diode array (8th-generation) |
| Sensor Resolution | 1000 channels, down to 0.01 µm |
| Flow Control | Precision metering piston pump + ultra-precise electromagnetic flow regulation |
| Sample Volume Accuracy | < ±1% |
| Counting Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Channel Flexibility | User-definable size bins (e.g., 4–70 µm(c), 1–100 µm, or 0.1 µm(c)) |
| Flow Rate Range | Sample: 5–150 mL/min |
| Rinse | 5–500 mL/min |
| Fluid Temperature Range | 0–80 °C |
| Ambient Operating Range | −15–50 °C |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9–2013, YBB00272004–2015, GB 8368 |
| Software | V8.9 Analytical Suite (PC & embedded touchscreen), FDA 21 CFR Part 11 compliant (audit trail, electronic signature, role-based 5-level access, data backup/restore, power-fail recovery) |
| Calibration Standards | NIST-traceable polystyrene latex (PSL) spheres, JJG 1061–2019, ISO 21501-4 |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601* |
| Sensor | 8th-generation dual-laser narrow-beam particle sensor |
| Detection Principle | Light Blockage (Optical Obstruction) |
| Measurement Range | 1–500 µm (optional 0.03–3000 µm) |
| Channel Count | 1000 adjustable channels (down to 0.01 µm resolution) |
| Sampling Flow Rate | 5–150 mL/min |
| Rinse Flow Rate | 5–500 mL/min |
| Sample Temperature Range | 0–80 °C |
| Accuracy | ±3% typical (per ChP 2020 & USP <788>) |
| Coincidence Limit | ≤2.5% at 1000 particles/mL |
| Resolution | >95% (ChP-calibrated), <10% (USP/ISO 21501-calibrated) |
| Compliance | ChP 2020 <0903>, USP <788>/<789>/<797>, EP 10.0, BP 2019, JP 17, ISO 21501-4, ISO 11171, GB/T 11446.9-2013, GB 8368, YBB 00272004-2015 |
| Software | V8.9 Regulatory Edition with 5-level user permissions, audit trail, electronic signature, 21 CFR Part 11 compliance, data backup/recovery, and power-fail protection |
| Interface | Touchscreen + optional wireless keyboard/mouse |
| Calibration Standards | JJG 1061, NIST-traceable latex spheres, or ISO 21501-4 reference materials |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Manufacture | China |
| Model | PQ-2A |
| Price | USD 64,500 (FOB China) |
| Brand | PULUODY |
|---|---|
| Model | TQ-01A |
| Application | Pharmaceutical Dissolution Media Deaeration |
| Display | High-Resolution Touchscreen LCD |
| Heating Range | 35–42 °C (adjustable to non-heating mode) |
| Volume Accuracy | ±1% (for set volumes ≥2 L) |
| Dispensing Resolution | 0.1 L |
| Flow Rate | 1.6 L/min |
| Dimensions (L×H×W) | 500 mm × 340 mm × 295 mm |
| Rated Power | 1700 W |
| Temperature Control Accuracy | ±2 °C |
| Residual Dissolved Oxygen | 3.0–5.0 mg/L (upgradable to <2.8 mg/L) |
| Minimum Inlet Medium Temperature | ≥18 °C |
| Pre-Filter Options | 40 µm / 25 µm / 20 µm Stainless Steel Mesh |
| Compatible Media | Purified water, distilled water (pH 1–14, surfactant-free) |
| Brand | PUSH |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | PS-KR206 |
| Price | USD 2,380 (approx.) |
| Display | 5-inch HD color touchscreen |
| Sample Capacity | 4 parallel test cells |
| Temperature Control Range | Ambient to 110 °C |
| Temperature Accuracy | ±0.02 °C |
| Temperature Sensor | Imported PT100 platinum resistance thermometer |
| Heating Method | PID-controlled resistive heating |
| Stirring Mechanism | Motorized vertical lift with gear-free mechanical transmission |
| Stirring Duration | 0–99 minutes (adjustable) |
| Timing Range | 0–99 hours (independent countdown timer) |
| Data Storage | 500 test records with timestamp, temperature setpoint, and duration |
| Power Supply | AC 220 V ±20%, 50 Hz ±10% |
| Max. Power Consumption | 800 W |
| Operating Environment | 5–40 °C, <85% RH (non-condensing) |