| Brand | Tianze Environmental |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Model | TZ-XM5 |
| Instrument Category | Pest Surveillance System |
| Power Consumption | ≤50 W |
| Solar Panel | 60 W |
| Battery | 12 V / 24 Ah |
| Display | 7-inch Capacitive Touch LCD (Android-based UI) |
| Imaging Sensor | 12 MP Color CMOS |
| Environmental Sensors | Wind Speed & Direction, Ambient Temperature & Humidity, Rainfall |
| Connectivity | 4G LTE / Wi-Fi / Ethernet |
| Insulation Resistance | ≥2.5 MΩ |
| Brand | UIC (United Instruments Corporation) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MODEL 833 |
| Price | USD 18,200 (FOB US port, ex-works pricing basis) |
| Brand | PCS Instruments |
|---|---|
| Origin | United Kingdom |
| Model | USV |
| Shear Rate Range | up to 1×10⁷ s⁻¹ |
| Temperature Range | 40 °C to 150 °C |
| Rotor/Spindle Material | Tungsten Carbide |
| Stator Material | Tungsten Carbide |
| Gap Setting | Fixed 1 mm |
| Motor Type | DC Servo Motor |
| Max Speed | 20,000 rpm |
| Acceleration Time (0–full speed) | ≤100 ms |
| Torque Measurement | Integrated via microprocessor-controlled motor and electromagnetic clutch |
| Thermal Management | Optimized gap geometry minimizes shear-induced temperature rise |
| Calibration | No routine gap calibration required due to matched thermal expansion coefficients |
| Brand | -- |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ultrasonic Valve Leak Detection System |
| Pricing | Available Upon Request |
| Brand | SOLGE |
|---|---|
| Origin | South Korea |
| Model | VARTECTOR |
| Application | ASTM D7843-compliant film potential analysis of phosphate ester fire-resistant hydraulic fluids (EHC systems) |
| Measurement Principle | Reflectance-based colorimetric quantification of deposited insolubles on membrane filters using CIE L*a*b* color space |
| Compliance | Fully aligned with ASTM D7843–21 “Standard Test Method for Quantifying Potential for Insoluble Formation in Phosphate Ester Fluids” |
| Automation Level | Fully automated load control, optical measurement, system verification, and diagnostic reporting |
| Data Output | ΔE, ΔL*, a*, b* values |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | AC24P-5 |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | ID900/DW800 |
| Application Field | Flexible Printed Circuit (FPC) and Panel Manufacturing |
| Compliance Context | Designed for ISO 9001-certified electronics assembly lines |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PIS 24-365 |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PIS Vacuum 24-365 |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Model | RPT 100 |
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WAPS24-365 |
| Pricing | Available Upon Request |
| Brand | Vcam |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Region of Manufacture | Domestic (China) |
| Model | WTT-100 |
| Pricing | Available Upon Request |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | CSF 6 |
| Price Range | USD 13,500 – 27,000 |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | FIWE |
| Sample Capacity | 6 positions (independent operation per sample) |
| Measurement Principle | Gravimetric difference method after sequential acid/alkali digestion (AOAC 978.10, ISO 5498, ISO 6865, EN ISO 13906) |
| Repeatability (RSD) | ±1% |
| Sample Mass Range | 0.5–3 g |
| Reagent Preheating Units | Dual independent RC2 heaters (RT to 370 °C) |
| Filtration & Backflush | Integrated air pump with three-way valve control |
| Waste Handling | Precision peristaltic pump for residue collection and effluent evacuation |
| Safety System | Self-diagnostic routine with audible/visual alarm timer |
| Construction | Stainless steel housing with chemical-resistant coating |
| Display | LCD interface with programmable time (0–99 min) and temperature settings |
| Power | 1200 W |
| Ambient Operating Temperature Control | Electronic PID regulation |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | GDE |
| Temperature Control Accuracy | ±0.2 °C |
| Max Operating Temperature | 105 °C |
| Bath Material | Transparent Polycarbonate |
| Stirring Configuration | 6-Position Magnetic Stirring |
| Water Bath Type | Deionized-Water-Compatible Constant-Temperature Bath |
| Automation | Programmable Timer for Unattended Operation |
| Compliance | Designed for AOAC 991.43, AACC 32-05, and ISO 13905 Enzymatic-Gravimetric Methods |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | GDE-CFS6 |
| Temperature Range | Ambient to 100 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Sample Mass Range | 0.5–3 g |
| Relative Error | ≤1% |
| Fiber Quantification Range | 0.1–99% |
| Batch Capacity | 6 samples |
| Housing | Epoxy-coated steel for chemical and mechanical resistance |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | NDA702 |
| Detection Principle | High-Temperature Combustion (Dumas Method) |
| Carrier Gases | Helium and Argon (switchable without hardware/software modification) |
| Analysis Time | ~3–4 min per sample |
| Automation Level | Fully Automated, Unattended Operation |
| Compliance | GLP-compliant architecture, TEMS™ certified design |
| Sample Forms | Solid and liquid matrices |
| Reagent Requirement | None (dry chemistry method) |
| Brand | VELP |
|---|---|
| Origin | Italy |
| Model | SER158 |
| Application Category | Fully Automated Protein and Fat Determination Instrument |
| Extraction Principle | Randall Continuous Extraction Technology |
| Compliance Standards | AOAC 920.39, ISO 1443, ISO 6496, EPA 3541, APHA 5520E, UNI EN ISO 1443 |
| Safety Certification | CE, IEC 61010-1 |
| Brand | Vientiane Environment |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WX-CQD3 |
| Instrument Category | Pest Surveillance System |
| Compliance | GB/T 24689.1–2009 |
| Construction | Stainless Steel Monocoque Frame |
| Power Supply | 240W Polycrystalline Solar Panel + 12V/200Ah Sealed Lead-Acid Battery |
| Standby Power Consumption | ≤5 W |
| Operational Power | ≤450 W |
| UV Light Source | 20W Blacklight Tube (Peak Wavelength: 365 nm) |
| Insect Killing & Drying Method | Dual-Layer Far-Infrared Heating Chamber (Temp: 85±5°C after 15 min |
| Mortality Rate | ≥98% |
| Specimen Integrity Rate | ≥95% |
| Insect Collection | 8-Position Auto-Rotating Tray (Time-Stamped Segmentation) |
| Weather Resilience | Integrated Rain Diversion System with Drainage Channel |
| Environmental Sensors Interface | Optional Expansion for Anemometer, Hygrothermograph, Pyranometer, Soil Moisture/Temperature, and Rain Gauge |
| Communication | GPRS Data Transmission Module |
| Control Interface | 7-inch Color LCD Touchscreen with LED Time/Temp/RH Display |
| Lightning Protection | Built-in Surge Protection Device (SPD) |
| Dimensions | 650 mm × 650 mm × 2000 mm (L×W×H) |
| Rated Service Life | ≥10 Years |
| Brand | Vientiane Environment |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WX-GK2 |
| Instrument Type | Migratory Pest Monitoring System |
| Light Source | 1000 W Halogen Searchlight |
| IR Chamber Temp | 85 ± 5 °C (reached within 15 min) |
| Camera Resolution | 1200 MP |
| Display | 7-inch Capacitive Touch LCD (Android OS) |
| Power Input | AC 220 V ± 60 V |
| Standby Power | ≤30 W |
| Max Operational Power | ≤1200 W |
| Dimensions | 650 × 650 × 2100 mm |
| Insect Collection Capacity | 1.5 L (8-day segmented storage) |
| Connectivity | 4G / Wi-Fi / Ethernet |
| Environmental Sensor Interfaces | Wind Speed/Direction, Ambient Temp/RH, Illuminance, Rainfall, Soil Temp/Moisture |
| IP Rating | IP65 (with integrated rain drainage & lightning protection) |
| Insulation Resistance | ≥2.5 MΩ |
| Brand | Vientiane Environment |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | WX-TD1 |
| Price | USD 425 (approx.) |
| Brand | VISAYA |
|---|---|
| Origin | USA |
| Model | FOAM DDI |
| Compliance | ASTM D892, ASTM D6082, GB/T 12579, SH/T 0722 |
| Imaging System | High-Resolution CCD with LED Illumination Control |
| Sample Volume | ~200 mL in 1000 mL calibrated cylinder |
| Temperature Control Range | Ambient to 99.9 °C |
| Display | Integrated HD Touchscreen Interface |
| Data Output | Exportable CSV/Excel reports with timestamped video log |
| Software Features | Real-time foam height tracking, algorithmic foam volume quantification, manual result override, full-test video recording |
| [Brand | Moon-BJ |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Medical-Grade Dermatological Imaging System |
| Model | VISIA 7 |
| Light Sources | Standard White Light & UV-A (365 nm) |
| Analyzed Parameters | 8 Quantitative Skin Features (Pigmentation, Pores, Wrinkles, Texture, UV Spots, Porphyry, Red Areas, Brown Spots) |
| Database Comparison | Age-, Gender-, and Ethnicity-Matched Reference Norms |
| Advanced Capabilities | Real-Time Zoom, 3D Surface Viewer, Simulated Aging Algorithm, Eyelash Length Measurement |
| Compliance | Designed for Clinical Dermatology and Aesthetic Practice Environments] |
| Brand | VKTR |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | X-3680 |
| Pricing | Available Upon Request |
| Brand | Wahyong Instrument |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DGU-900 |
| Price Range | USD 7,000 – 14,000 |
| Brand | Wahyong Instrument |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | DS-1206AT |
| Instrument Type | Offline Dissolution Tester |
| Vessels | 12 |
| Temperature Range | Ambient to 45.0 °C |
| Temperature Accuracy | ≤ ±0.2 °C |
| Rotational Speed Range | 25–250 rpm |
| Paddle Wobble Amplitude | ≤ 0.2 mm |
| Basket Wobble Amplitude | ≤ 0.5 mm |
| Water Bath Temperature Control Range | Ambient to 45.0 °C |
| Water Bath Temperature Resolution | 0.1 °C |
| Water Bath Volume | 54 L |
| Brand | Wallace |
|---|---|
| Origin | United Kingdom |
| Model | P14 |
| Type | Rapid Plastometer for Uncured Natural Rubber |
| Compliance | GB/T 3517–2022, ASTM D926 (equivalent methodology), ISO 2007 (Plasticity of Raw Rubber) |
| Calibration | Semi-automatic 1 mm gap calibration, load calibration, temperature calibration |
| Data Output | Sample ID tagging, timestamped results, traceable test records |
| Operation Modes | Single-value, median, or mean reporting |
| Display | Real-time digital readout of deformation under standardized load and temperature |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | WDDG |
| Pricing | Available Upon Request |
| Power Supply | 220 V AC, ~50 W |
| Carrier Gas | High-Purity Nitrogen, 5–10 L/h at ~0.5 bar inlet pressure |
| Measurement Range | 0–10 g/m²·day |
| Output | Direct digital readout across full scale (2.5-digit resolution) |
| Connected Meter | Triple-range analog meter (0–0.1 / 0–1.0 / 0–10 g/m²·day), 100 mV full-scale output |
| Accuracy | ±2% of reading or ±0.005 g/m²·day (whichever is greater) |
| Test Duration | 1–3 hours (sample-dependent) |
| Sample Diameter | 108 mm |
| Temperature Range | –20 °C to +60 °C |
| RH Gradient Generation | Compliant with DIN 53122 Part 2 |
| Dimensions (W×D×H) | 45 × 33 × 45 cm |
| Weight | 23 kg |
| Brand | WEISSTECH |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | WSPL-M |
| Price | ¥19,900 |
| Test Method | Semi-Automatic |
| Measurement Range | 200–5600 kPa |
| Unit Options | kPa, psi (lbf/in²), kgf/cm² |
| Accuracy | ±0.5% FS |
| Clamping Ring Diameter | Upper & Lower Rings: 31.5 mm |
| Hydraulic Oil Speed | 170 ± 15 mL/min |
| Display | LED Digital Display |
| Hydraulic Medium | Imported Silicone Oil |
| Power Supply | 220 V, 50 Hz |
| Safety Protection | Automatic pressure relief upon overpressure detection |
| Key | Brand: Wickert |
|---|---|
| Origin | Germany |
| Model | WLP S Series |
| Compliance | GB/T 6038, ISO 2393, ASTM D3182 |
| Type | Laboratory-scale hydraulic平板 vulcanizer for rubber sample curing |