| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR Vision |
| Application | Gasoline Octane Number (RON/MON), Diesel Cetane Number (CN) |
| Portability | Portable |
| Measurement Range | 70–110 |
| Measurement Accuracy | ±1 unit |
| Analysis Time | <5 min |
| Sample Volume | 6 mL |
| Compliance | GB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, EN 14078, ASTM D7806, GB/T 23801, ASTM E1655, GB/T 29858 |
| Spectral Technology | Fourier Transform Mid-Infrared (FT-MIR) with Dual Interferometer Architecture |
| Calibration Method | Partial Least Squares (PLS) Multivariate Quantitative Analysis |
| Integrated Density Measurement | Thermoelectrically Controlled Oscillating U-tube Densitometer |
| Operating Interface | 10-inch Industrial Capacitive Touchscreen (Multi-language: English, Chinese, German) |
| Data Storage | Internal SSD with Full Spectrum Archiving |
| Connectivity | 2× USB 3.0, 2× Gigabit Ethernet |
| Power Supply | 100–264 V AC, 47–63 Hz, 130 W |
| Optional Mobile Power | 12 V DC Vehicle Adapter |
| Dimensions | 293 × 390 × 280 mm |
| Weight | 12 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | MINISCAN IR Vision Pro |
| Pricing | Upon Request |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINISCAN IR Vision Professional |
| Measurement Parameters | Gasoline Octane Number (RON/MON), Diesel Cetane Number |
| Portability | Portable |
| Detection Principle | Mid-Infrared Spectroscopy |
| Measurement Range | 70–110 (Octane/Cetane scale) |
| Accuracy | ±0.1 |
| Analysis Time | ≤60 seconds |
| Sample Volume | 6 mL |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINISCAN IR Vision Professional |
| Portability | Portable |
| Measurement Parameters | Gasoline Research Octane Number (RON), Motor Octane Number (MON), Diesel Cetane Number (CN) |
| Measurement Range | RON/MON 70–110 |
| Accuracy | ±0.5 ON/CN units |
| Analysis Time | <80 s per sample |
| Sample Volume | 6 mL |
| Spectral Range | Mid-IR (typically 4000–600 cm⁻¹) |
| Detector | High-stability DTGS or MCT (model-dependent) |
| Interferometer | Dual-mirror, laser-controlled, auto-alignment with thermal stabilization |
| Beam Splitter | Ge-coated KBr |
| Density Measurement | Integrated Peltier-regulated oscillating U-tube densitometer, resolution ±0.0001 g/cm³ |
| Data Processing | PLS regression with >100 validated chemometric models compliant with ASTM E1655 and GB/T 29858 |
| Compliance | Fully aligned with GB/T 33648–2017, ASTM D5845, ASTM D6277, EN 238, SH/T 0797, EN 14078, ASTM D7806, USP <857>, FDA 21 CFR Part 11 (audit trail & electronic signature ready) |
| Interface | 2× USB 3.0, 2× Gigabit Ethernet, optional Wi-Fi/4G module |
| Display | 10″ industrial-grade capacitive touchscreen (1280×800), glove-compatible UI |
| Operating Temperature | 10–40 °C |
| Power | 100–264 V AC, 47–63 Hz, 130 W |
| Field Power Option | 12 V DC automotive adapter |
| Dimensions | 293 × 390 × 280 mm |
| Weight | 12 kg |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Product Type | Portable Instrument |
| Standard Compliance | DIN 51805 |
| Temperature Range | –60 to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Measurement Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based thermoelectric control |
| Sample Handling | Standalone operation, no auxiliary equipment required |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Application Standard | DIN 51805 |
| Temperature Range | –60 °C to +30 °C |
| Temperature Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC / 10 A |
| Dimensions (W×H×D) | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Interface | RS232 |
| Display Languages | English, German |
| Cooling Method | Peltier-based |
| Sample Compatibility | NLGI Grades 000–3 Greases |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINITEST FFK |
| Test Principle | Corrosion-Resistant Capillary Extrusion (DIN 51805) |
| Temperature Range | −50 °C to +30 °C |
| Temp. Accuracy | ±0.1 °C |
| Pressure Range | 0–300 kPa |
| Pressure Accuracy | ±0.1 kPa |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 10 kg |
| Power Supply | 100–240 V AC, 50/60 Hz, 200 W or 12 V DC (optional) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP ON-LINE |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 2–1000 kPa |
| Temperature Range | 20–60 °C |
| Repeatability (r) | 0.30 kPa |
| Reproducibility (R) | 0.7 kPa |
| Sample Throughput Cycle Time | 7 min |
| Power Supply | 100/120/230/240 V AC, 50/60 Hz, 65 W |
| Dimensions (W × H × D) | 650 × 1160 × 400 mm |
| Weight | 50 kg |
| Explosion Protection | Class I, Division 1, Group D (NFPA 496, US) / Zone 1, II 2 G Ex d IIB T4 (EN 50016, EU) |
| Vapor-to-Liquid Ratios (V/L) | 4:1 (gasoline & crude oil), 1:2 (LPG & NPG), 20:1 (LVR temperature mode) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINIVAP Online |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0 to 1000.0 kPa |
| Temperature Range | 20–60 °C |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIVAP Online |
| Analysis Method | Three-stage Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 20–60 °C |
| Power Supply | 100/120/230/240 V AC, 50/60 Hz, 65 W |
| Dimensions (W×H×D) | 650 × 1160 × 400 mm |
| Weight | 50 kg |
| Repeatability (r) | 0.30 kPa |
| Reproducibility (R) | 0.70 kPa |
| Explosion Protection | Class I, NEMA 496 (US) / EN 50016 (EU) |
| Cycle Time | 7 min |
| Vapor-to-Liquid Ratios | 4:1 (gasoline & crude), 1:2 (LPG/NPG), 20:1 (LVR temperature) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MINIVAP VP Vision |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP Vision |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Repeatability | ≤ 0.2 kPa (pure substance @ 37.8 °C) |
| Reproducibility | ≤ 0.5 kPa (pure substance @ 37.8 °C) |
| Sample Volume | 1 mL |
| Test Time | ~5 min (method-dependent) |
| Display | 10-inch industrial-grade color touchscreen |
| Compliance | ASTM D5191, D6377, D6378, D6897, D5188 |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP Vision |
| Analysis Method | Triple Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Repeatability | ≤ 0.2 kPa (pure substance @ 37.8 °C) |
| Reproducibility | ≤ 0.5 kPa (pure substance @ 37.8 °C) |
| Sample Volume | 1 mL |
| Test Time | ~5 min (method-dependent) |
| Display | 10-inch industrial-grade touchscreen |
| Compliance | ASTM D5191, D6377, D6378, D6897, D5188, EN 13016-1+2, IP 394/409/481, JIS K2258-2, GOST 52340, SH/T 0769, SH/T 0794, GB/T 11509, GB/T 8017-2012 |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP VISION |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0 to 2000 kPa |
| Temperature Range | −100 to 300 °C |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MINIVAP VP VISION+ Crude Oil Package |
| Analysis Method | Three-stage Expansion Method |
| Compliance | ASTM D6377, ASTM D3700, GOST R 52340, EPA Method for TVP |
| Sample Volume | 250 mL (10 mL per test) |
| Maximum Operating Pressure | 7000 kPa |
| Material | High-grade stainless steel |
| Integrated Components | Pressure sensor, rupture disc, manual agitation plate, dedicated crude oil inlet interface |
| Filling Options | Manual or pressurized |
| Agitation | Built-in manual agitation plate with pressure monitoring |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPS/VPSH |
| Analysis Method | Three-Stage Piston Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 0–100 °C |
| Test Time | ~5 min per sample |
| Dimensions | 196 × 315 × 175 mm |
| Weight | 8 kg |
| Power Supply | 100–230 V AC, 50 Hz, 65 W |
| Optional DC Input | 12 V / 8 A |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | MiniVAP VPS/VPSH |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 0–100 °C |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPSH+ Crude Oil Package |
| Application | Crude oil vapor pressure (RVP/TVPR) determination per ASTM D323, D6377, and ISO 3014 |
| Sample Handling | Mobile piston cylinder sampling system with pressurized transfer and mechanical agitation |
| Automation | Fully automated measurement cycle including purge, equilibration, pressure stabilization, and cleaning |
| Compliance | Designed to meet ASTM D6377 (TVPR), ASTM D323 (RVP), ISO 3014, and EN 13016-1 requirements |
| Operating Temperature | 37.8 °C (100 °F) controlled bath |
| Pressure Range | 0–200 kPa (0–29 psi) absolute |
| Resolution | 0.1 kPa |
| Repeatability | ≤0.5 kPa (per ASTM D6377) |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Manufacturer |
| Product Category | Imported Instrument |
| Model | MiniVAP VPVision Crude Oil |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPVision Crude Oil |
| Analysis Method | Three-Stage Expansion |
| Pressure Range | 0–2000 kPa |
| Temperature Range | 0–120 °C |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | MiniVAP VPXpert |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–1000 kPa |
| Temperature Range | 0–120 °C |
| Sample Volume | 1 mL |
| Temperature Stability | ±0.1 °C |
| V/L Ratio Adjustable | 0.02/1 to 4/1 |
| Compliance | ASTM D5191, D6377, D6378, D323, D4953, D5188, D5190, D5482 |
| Data Interface | Dual USB, RS232, LIMS-compatible |
| Power Input | 90–264 V AC, 45–63 Hz, 200 W |
| Dimensions | 277 × 253 × 368 mm |
| Weight | 9 kg |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MiniVAP VPXpert |
| Analysis Method | Three-Stage Expansion Method |
| Pressure Range | 0–1000 kPa (0–145 psi) |
| Temperature Range | 0–120 °C (user-programmable up to 200 °C) |
| Temperature Stability | ±0.1 °C |
| V/L Ratio Adjustable | 0.02/1 to 4/1 |
| Sample Volume | 1 mL (10 mL total with wash cycle) |
| Compliance | ASTM D5191, D6377, D6378, EN 13016-1 & -2, IP 394, 409, 481, D323, D4953, D5188, D5190, D5482 |
| Dimensions | 277 × 253 × 368 mm |
| Weight | 9 kg |
| Power | 90–264 V AC, 45–63 Hz, 200 W |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MiniVIS 445 |
| Kinematic Viscosity Range | 0.2–2000 mm²/s (cSt) |
| Density Range | 0.62–2.00 g/cm³ |
| Temperature Range | −20 to +110 °C (Peltier-controlled, with 4 °C water cooling) |
| Temperature Stability | ±0.02 °C |
| Viscosity Resolution | 4 significant digits |
| Density Resolution | 0.0001 g/cm³ |
| Repeatability | ±0.3% of measured value (viscosity), ±0.0005 g/cm³ (density) |
| Sample Volume per Test | 5 mL (measurement), 25 mL total (including cleaning) |
| Throughput | 20 tests/hour (incl. cleaning at 100 cSt, 40 °C) |
| Compliance | ASTM D445, ISO 3104, ASTM D2270 |
| Power | 100–240 V AC, 50/60 Hz, 85 W |
| Dimensions (W×H×D) | 200 × 320 × 240 mm |
| Weight | 11 kg |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | MobileLab |
| Power Supply | Dual 12 V DC (rechargeable battery) & 230 V AC input |
| Environmental Control | Independent HVAC panel with 20 air changes/hour |
| Mounting | Seismically damped instrument racks |
| Water System | Integrated sink with fresh/distilled water supply and dedicated waste container |
| Data Integration | Centralized software via RS-232/USB serial interface |
| Compliance Support | Designed for ASTM D93, D130, D2887, D445, ISO 3104, ISO 2719, EN 13016, GOST R 51105, and related fuel testing standards |
| Brand | GRABNER |
|---|---|
| Origin | Austria |
| Model | MobileLab |
| Application | Gasoline Octane Number (RON/MON) and Diesel Cetane Number (CN) Analysis |
| Portability | Fully Mobile Laboratory Vehicle |
| Measurement Principle | Near-Infrared (NIR) Spectroscopy |
| Measurement Range | 40–120 (Octane/Cetane Scale) |
| Accuracy | ±1 unit |
| Analysis Time | <15 minutes per sample |
| Sample Volume | 10 mL |
| Power Supply | Dual-source — rechargeable 12 V DC battery + external 240 V AC input |
| Compliance | Designed to support ASTM D2699, D2700, D613, ISO 5164, ISO 5163, EN 228, EN 590, GOST R 51105, GOST R 51463 |
| Brand | Grabner |
|---|---|
| Origin | Austria |
| Model | ParaFuel™ |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Scan Time | Adjustable, default 30 s |
| Communication Interface | Standard TCP/IP Ethernet, optional Modbus TCP or 4–20 mA |
| Process Points | Up to 20 via multiplexed fiber-optic probes |
| Sample Temperature Range | Up to 150 °C |
| Sample Pressure Rating | Up to 7,000 kPa |
| Fiber Optic Cable Length | Standard 3 m, extendable to 200 m |
| Enclosure Rating | IP65 (dust- and water-resistant) |
| Hazardous Area Classification | CSA C1D2 (optional C1D1) |
| Desktop Unit Dimensions | 30.5 cm × 39.7 cm × 34.9 cm (12" × 15" × 13") |
| Data Storage | Automatic local logging + LIMS integration via TCP/IP |
| Software Platform | LTBus-based Windows application with audit trail, user access levels, and FDA 21 CFR Part 11–compliant electronic signatures (optional) |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | GRACE 923 |
| Pricing | Available Upon Request |
| Certified Standard | Compliant with GB/T 11132 and ASTM D1319 |
| Average Pore Diameter | 32 Å |
| Pore Size Distribution | Narrow |
| Packaging | 500 g per bottle |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | M3900 |
| Price | Upon Request |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M7355 |
| Pricing | Upon Request |
| Max Pressure | 20,000 psi |
| Full-Scale Range | ±30 mL |
| Pressure Control Accuracy | ±25 psi |
| Water Supply | Municipal tap water |
| Power | 120 V, 50/60 Hz |
| Dimensions | 19" W × 24" D × 47" H |
| Weight | 95 lb |
| Brand | Grace |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | M9200 |
| Quotation | Upon Request |
| Operating Temperature | Ambient to 177 °C |
| Maximum Working Pressure | 5000 psi |
| Shear Rate Range | 0–1500 s⁻¹ |
| Sample Volume | 115 mL |
| Intermediate Vessel Capacity | 500 mL, Rated to 6000 psi |
| Observation Chamber | Stereo Microscope with Sapphire Window |
| Foaming Gas Options | CO₂ or N₂ |