Infrared Moisture Analyzer
Filter
Showing 121–150 of 157 results
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MOC-120H |
| Price Range | USD 1,400 – 4,200 |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | MOC-120H |
| Measurement Principle | Infrared Heating + Gravimetric Loss-on-Drying |
| Weighing Range | 120 g |
| Minimum Readability | 0.001 g |
| Moisture Content Range | 0.01–100.00% |
| Moisture Resolution | 0.01% |
| Sample Pan Diameter | 130 mm |
| Heating Source | Medium-Wave Quartz Infrared Heater |
| Temperature Setting Range | 30–180 °C (1 °C increments) |
| Heater Lifetime | 20,000–30,000 hours |
| Power Supply | AC 100–120 V / 220–240 V, max. 640 W |
| Dimensions (W×D×H) | 220 × 415 × 190 mm |
| Weight | 4.5 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Interface | RS-232C (direct Excel data export) |
| Predefined Modes | 10 |
| Stop Criteria | Auto-stop, Time-stop |
| Drying Profiles | Standard, Rapid, Slow, Stepwise, Predictive (Comparative) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | MOC120H |
| Measurement Principle | Gravimetric Loss-on-Drying (Infrared Heating) |
| Sample Capacity | 0.5–120 g |
| Moisture Resolution | 0.01% or 0.1% (selectable) |
| Mass Resolution | 0.001 g |
| Moisture Range | 0–100% (w/w), 0–500% (dry basis) |
| Repeatability | ±0.02% (≥10 g sample) |
| Temperature Range | 30–180 °C (1 °C increments) |
| Heating Source | Medium-Wave Infrared Lamp (625 W max) |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions | 220 × 415 × 190 mm (W×D×H) |
| Weight | 4.5 kg |
| Data Storage | 100 measurement records |
| Method Storage | 10 user-defined protocols |
| Interface | RS-232C, Windows Direct Pass-through |
| Operating Environment | 5–40 °C, ≤85% RH |
| Sample Pan | Stainless Steel (Ø130 mm × 13 mm depth) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | MOC63u |
| Heating Source | Halogen Lamp |
| Maximum Capacity | 60 g |
| Minimum Display | 0.001 g |
| Moisture Resolution | 0.01% / 0.1% (selectable) |
| Repeatability | ±0.15% (2 g sample), ±0.05% (5 g sample), ±0.02% (10 g sample) |
| Heating Power | 400 W |
| Temperature Range | 50–200 °C (1 °C increments) |
| Sample Pan Diameter | 95 mm |
| Dimensions (W×D×H) | 202 × 336 × 157 mm |
| Weight | 4 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Measurement Modes | Standard, Rapid Drying, Slow Drying, Stepwise Drying |
| Auto-Stop Criteria | Moisture change ≤ threshold for 30 s |
| Timer Range | 1–120 min (extendable to 12 h) |
| Interfaces | RS-232C (9-pin), DATA I/O, USB |
| Internal Memory | 10 methods, 100 measurement records |
| Display | Backlit LCD |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | MOC63U |
| Maximum Sample Capacity | 60 g |
| Minimum Sample Weight | 0.02 g |
| Minimum Display Resolution | 0.001 g / 0.01% or 0.1% (selectable) |
| Repeatability | ±0.15% (2 g sample), ±0.05% (5 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen Lamp |
| Heating Power | 400 W |
| Temperature Setting Range | 50–200 °C (1 °C increments) |
| Display | Backlit LCD |
| Pan Diameter | 95 mm |
| Dimensions (W × D × H) | 202 × 336 × 157 mm |
| Weight | 4 kg |
| Operating Environment | 5–40 °C, ≤85% RH |
| Measurement Modes | Standard, Rapid Dry, Slow Dry, Step Dry |
| Measurement Duration | 1–120 min (extendable up to 12 h) |
| Interfaces | RS-232C (9-pin), DATA I/O, USB |
| Predefined Method Storage | 10 methods |
| Data Storage Capacity | 100 results |
| Optional Accessories | Temperature calibration kit |
| Brand | Shimadzu |
|---|---|
| Model | Unibloc MOC63U |
| Heating Source | Halogen Lamp |
| Temperature Range | 50–200 °C |
| Minimum Sample Weight | 0.001 g |
| Display | Backlit LCD |
| Interfaces | RS-232C, USB, DATA I/O |
| Data Export | Direct to Microsoft Excel via Windows Pass-Through Window |
| Measurement Modes | Auto-Stop, Time-Stop, Standard/Fast/Slow/Step Drying |
| Dimensions (L) | 202 mm |
| Brand | SHYP |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50-1 |
| Heating Source | Halogen Lamp |
| Max Capacity | 50 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | 0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (10 s increments) |
| Temperature Range | 50–180 °C (1 °C increments) |
| Display | Dot-matrix LCD with backlight |
| Interface | RS232 serial port |
| Pan Diameter | 100 mm |
| Dimensions (L×W×H) | 285 × 160 × 150 mm |
| Net Weight | 3.0 kg |
| Operating Ambient | 10–30 °C |
| Brand | SHYP |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50-1 |
| Maximum Capacity | 50 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Source | Halogen Lamp |
| Temperature Range | 50–180 °C (adjustable in 1 °C increments) |
| Heating Duration | 1–99 min (adjustable in 10 s increments) |
| Display | Backlit dot-matrix LCD |
| Interface | RS232 serial port |
| Pan Diameter | 100 mm |
| Dimensions (L×W×H) | 285 × 160 × 150 mm |
| Net Weight | 3.0 kg |
| Operating Ambient | 10–30 °C |
| End-point Modes | Timed & Automatic (based on weight change rate) |
| Brand | SHYP |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50-10 |
| Maximum Capacity | 50 g |
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Source | Halogen Lamp |
| Temperature Range | 50–180 °C (adjustable in 1 °C increments) |
| Heating Duration | 1–99 min (10 s increment) |
| Endpoint Control Modes | Timed, Automatic |
| Display | Backlit Dot-Matrix LCD |
| Communication Interface | RS232 |
| Pan Diameter | 100 mm |
| Dimensions (L×W×H) | 285 × 160 × 150 mm |
| Net Weight | 3.0 kg |
| Operating Ambient | 10–30 °C |
| Brand | SHYP |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50-5 |
| Heating Source | Halogen Lamp |
| Maximum Capacity | 50 g |
| Readability | 5 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Duration | 1–99 min (adjustable in 10-s increments) |
| Temperature Range | 50–180 °C (1 °C step) |
| Display | Moisture %, Solid %, Weight, Time, Temperature |
| Pan Diameter | 100 mm |
| Dimensions (L×W×H) | 285 × 160 × 150 mm |
| Net Weight | 3.0 kg |
| Communication Interface | RS-232C |
| Brand | SHYP |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50-5 |
| Heating Source | Halogen Lamp |
| Max Capacity | 50 g |
| Readability | 5 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (adjustable in 10-s increments) |
| Temperature Range | 50–180 °C (1 °C step) |
| Display | Dot-matrix LCD with backlight |
| Interface | RS232 serial port |
| Pan Diameter | 100 mm |
| Dimensions (L×W×H) | 285 × 160 × 150 mm |
| Net Weight | 3.0 kg |
| Operating Ambient | 10–30 °C |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | AGS60 250C PRO, AGS120 250C PRO |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g / 120 g |
| Tare Range | –60 g / –120 g |
| Readability | 0.001 g |
| Repeatability | 0.001 g |
| Linearity | ±0.002 g |
| Accuracy Class | II |
| Resolution | 0.01% moisture |
| Moisture Repeatability | ±0.3% (2 g sample), ±0.06% (5 g sample) |
| Interface | USB, RS232C, PS2 |
| Max Drying Temperature | 250 °C |
| Drying Time Range | 1–180 s per step, up to 10 hr total |
| Drying Power | 250 W |
| Preheat Time | ~30 s |
| Pan Diameter | 90 mm |
| Chamber Dimensions | 108 × 20 mm |
| External Dimensions | 215 × 345 × 200 mm |
| Brand | Scientific Industries |
|---|---|
| Origin | USA |
| Model | ATS60, ATS120 |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g / 120 g |
| Readability | 0.001 g |
| Linearity | ±0.002 g |
| Accuracy Class | II |
| Resolution | 0.01% |
| Moisture Measurement Accuracy | ±0.1% (2 g sample), ±0.04% (5 g sample), 1% (0.02–0.5 g sample) |
| Drying Temperature Range | Up to 160 °C |
| Drying Time Range | 1–600 s (10 hr max) |
| Drying Power | 200 W |
| Preheat Time | ~60 s |
| Pan Diameter | 90 mm |
| Drying Chamber Dimensions | 108 × 20 mm |
| External Dimensions | 185 × 290 × 170 mm |
| Net Weight | 6.8 kg |
| Interfaces | USB, RS232C, PS2 |
| Brand | SUNNY HENGPING INSTRUMENT |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Yes |
| Country of Origin | China |
| Model | ESH Series (ESH122 / ESH123 / ESH124) |
| Heating Source | 600 W Quartz Halogen Lamp |
| Weighing Range | 120 g |
| Readability | 5 mg / 1 mg / 0.1 mg |
| Moisture Readability | 0.01% / 0.01% / 0.001% |
| Repeatability | ±0.5% / ±0.25% / ±0.1% (at 2 g) |
| Display | 4.3″ TFT Touchscreen |
| Temperature Range | 40–180 °C |
| Heating Modes | Standard / Progressive / Step |
| Measurement Modes | Auto / Manual / Timer / Loss-on-Drying |
| Data Storage | 36 test records |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Max Power Consumption | 800 W |
| Operating Ambient | 5–40 °C |
| Sample Pan Diameter | Φ100 mm |
| Dimensions (W×D×H) | 380 × 200 × 210 mm |
| Net Weight | 5.8 kg |
| Gross Weight | 7.8 kg |
| Brand | Sunny Hengping Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | ESH31 |
| Price | USD 780 (FOB Shanghai) |
| Heating Method | Quartz Halogen Lamp |
| Weighing Range | 110 g |
| Readability | 10 mg |
| Display | High-Resolution LCD (Backlight Optional) |
| Sensor Type | Strain-Gauge Load Cell |
| Sample Pan Diameter | Φ90 mm |
| Net Weight | 5.8 kg |
| Dimensions (L×W×H) | 200 × 180 × 380 mm |
| Operating Temperature | 5–40 °C |
| Temperature Range | 40–199 °C (1 °C increments) |
| Moisture Range | 0.00–100.00 % |
| Moisture Readability | 0.01 % |
| Drying Range | 100.00–0.00 % |
| Drying Readability | 0.01 % |
| Timer Setting | 3–99 min |
| Data Storage | 15 test history entries |
| Calibration Standard | Class F2 Stainless Steel Weights |
| Heating Power | 450 W |
| Lamp Lifetime | ≥5000 h |
| Cooling System | Low-Noise Fan (<20 dB) + Multi-Channel Airflow |
| Interface | RS232 Serial Port |
| Housing Material | Die-Cast Aluminum + High-Temp Polymer (250 °C continuous rating) |
| Chamber | Dual-Layer 304 Stainless Steel, Mirror-Finished Interior |
| Viewing Window | Frosted Tempered Glass |
| Sample Height Clearance | 22 mm |
| Leveling | Precision Bubble Level + Adjustable Feet |
| Standard Accessories | 50 × Aluminum Sample Pans |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | DHS Series |
| Heating Method | Infrared |
| Max Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (DHS-16A), 50–200 °C (DHS-20A) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min steps) |
| Termination Modes | Auto (weight stability), Timed, Manual |
| Built-in Methods | 50 user-programmable protocols |
| Output Parameters | Initial mass (g), Residual mass (g), Moisture content (% w/w), Dry matter (%), Moisture loss (%), Regain (%), Wet basis moisture (%), Heating mode, Set temperature, Duration |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation templates available |
| Power Supply | 220 VAC (±15% / −10%), 50 Hz |
| Power Consumption | 400 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Line | LHS Series |
| Heating Method | Halogen Lamp |
| Maximum Capacity | 61 g / 100 g / 120 g |
| Readability | 0.1 mg / 0.001% (HR models), 1 mg / 0.01% |
| Display | Backlit LCD with 5-key interface |
| Temperature Range | 50–160 °C (LHS-16 models), 50–200 °C (LHS-20 models) |
| Temperature Increment | 1 °C (from 50 °C) |
| Heating Time Setting | 0–99 min (1-min increments) |
| Termination Modes | Automatic (weight change-based), Timed, Manual |
| Built-in Methods | 50 pre-programmed |
| Result Outputs | Initial mass (g), Residual mass (g), Moisture content (%), Dry matter (%), Moisture loss (%), Rehydration ratio, Wet basis moisture (%) |
| Calibration | External weight calibration (100 g standard |
| Interface | RS232 |
| Compliance Support | IQ/OQ/PQ documentation support |
| Power Supply | 220 VAC (−15% to +10%), 50 Hz |
| Power Consumption | 420 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Optimal | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 510 × 353 × 333 mm |
| Net Weight | 8.9 kg |
| Brand | Techcomp |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | YLS-B Series |
| Price Range | USD 700 – 1,400 (FOB) |
| Heating Method | Halogen Lamp |
| Max Capacity | 60 g (YLS-B Plus) / 20 g (YLS-B Standard) |
| Readability | 1 mg (60 g model) / 2 mg (20 g model) |
| Moisture Resolution | 0.02–0.1% |
| Temperature Range | 50–160 °C (1 °C increments) |
| Heating Time | 0–99 min (1 min steps) |
| Display | Backlit dot-matrix LCD with dual blue/white background |
| Data Storage | 50 sample profiles |
| Interface | RS232C |
| Calibration | External weight calibration (20 g for YLS-B |
| Compliance | Supports IQ/OQ/PQ validation |
| Power Supply | 220 VAC (±15%/+10%), 50 Hz |
| Power Consumption | 300 W |
| Operating Environment | 5–40 °C, 25–85% RH (non-condensing) |
| Recommended Ambient | 15–30 °C, 50–75% RH (non-condensing) |
| Dimensions (W×D×H) | 458 × 278 × 246 mm |
| Net Weight | 5.5 kg |
| Brand | Timepower |
|---|---|
| Model | TP3301 |
| Origin | Hebei, China |
| Manufacturer Type | Direct Manufacturer |
| Compliance | HJ 637–2018 |
| Measurement Principle | Infrared Spectrophotometry (Triple-Wavenumber Absorption at 2930 cm⁻¹, 2960 cm⁻¹, and 3030 cm⁻¹) |
| Sample Preparation | Tetrachloroethylene Extraction + Magnesium Silicate Adsorption |
| Output | Total Extractable Hydrocarbons, Petroleum Hydrocarbons, and Animal/Vegetable Oils (by difference) |
| Operational Mode | Standalone with Onboard Data Processing |
| Calibration | Reference Coefficient-Based (No Calibration Curve Required) |
| Wavenumber Accuracy | < 1 cm⁻¹ (Secant-Mode Scanning) |
| Optical System | Integrated Beam Path with Pulsed IR Source, Active Narrowband Filtering, and Digital Lock-in Amplification |
| Zero Adjustment | Real-time Auto-zero During Source Off-Cycle |
| Display & Interface | Chinese GUI, Touchscreen or Keypad Navigation |
| Data Handling | Onboard Storage, Statistical Analysis, Spectrum Visualization, Thermal Printing |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-100A-1 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–100 g |
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Recommended Sample Mass | 3–10 g |
| Minimum Sample Mass | 0.5 g |
| Heating Time Setting | 1–99 min (1 min increments) |
| Temperature Range | 50–160 °C |
| End Point Control | Timer-based or Auto-termination |
| Display | Backlit dot-matrix LCD showing moisture %, solids %, weight, elapsed time |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| Max Capacity | 100 g |
|---|---|
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Plate Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-10A |
| Heating Method | Halogen Lamp |
| Display | High-Resolution Backlit Dot-Matrix LCD |
| Interface | RS-232C |
| Features | Automatic Tare, Zero Drift Compensation, Real-Time Dryness Monitoring |
| Compliance | Designed for ISO 5725 (accuracy & reproducibility), ASTM E1447 (moisture in solids), and USP <921> (Loss on Drying) |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Model | DSH-10A |
| Maximum Capacity | 10 g |
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Temperature Range | 50–180 °C |
| Heating Time Programmable | 1–99 min (1-min increments) |
| Heating Source | Halogen lamp |
| Pan Diameter | 100 mm |
| Display | Backlit dot-matrix LCD |
| Interface | RS-232C |
| End-point Detection | Timed & Automatic |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Compliance | ISO 5725 (accuracy & precision), ASTM E1447, USP <921>, GLP-ready data logging |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | DSH-10A |
| Max Capacity | 10 g |
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Display | Backlit Dot-Matrix LCD |
| Interface | RS232 |
| End-Point Modes | Timed & Auto-Termination |
| Data Output | Moisture %, Solid %, Weight (g), Elapsed Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 Halogen Moisture Analyzer |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| End Point Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight (g), Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication | RS232 |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-1 |
| Heating Source | Halogen Lamp |
| Readability | 1 mg |
| Weighing Range | 0–50 g |
| Repeatability (3 g sample) | ±0.2% |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Endpoint Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight, Time, Date |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| Interface | RS232 |
| Max Capacity | 50 g |
|---|---|
| Readability | 1 mg |
| Repeatability (3 g sample) | ±0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1 min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timer-Controlled & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |
| Max Capacity | 50 g |
|---|---|
| Readability | 10 mg |
| Repeatability (3 g sample) | ±0.5% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-Point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Weight (g), Elapsed Time, Date |
| Brand | Yoke |
|---|---|
| Origin | Shanghai, China |
| Model | DSH-50A-5 |
| Heating Source | Halogen Lamp |
| Weighing Range | 0–50 g |
| Readability | 5 mg |
| Temperature Range | 50–160 °C |
| Heating Time | 1–99 min (1-min increments) |
| Sample Capacity | 0.5–10 g (recommended: 3–10 g) |
| Repeatability (3 g sample) | ±0.3% |
| Display | Backlit dot-matrix LCD |
| Interface | RS232 |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Gross Weight | 6 kg |
| End-point Modes | Timed & Automatic |
| Heating Profile | Standard |
| Display Outputs | Moisture %, Solid %, Sample Weight, Elapsed Time |
| Max Capacity | 50 g |
|---|---|
| Readability | 5 mg |
| Repeatability (3 g sample) | ±0.3% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–10 g |
| Heating Time Range | 1–99 min (1-min increments) |
| Temperature Range | 50–180 °C |
| Heating Source | Halogen Lamp |
| Pan Diameter | 100 mm |
| Dimensions (W×D×H) | 265 × 160 × 150 mm |
| Net Weight | 5 kg |
| Communication Interface | RS232 |
| End-point Modes | Timed & Automatic |
| Display Parameters | Moisture %, Solid %, Mass (g), Elapsed Time, Date |