| Brand | Denver |
|---|---|
| Origin | USA |
| Model | IR-120 |
| Weighing Range | 120 g |
| Readability | 0.1 mg |
| Moisture Resolution | 0.0001% |
| Repeatability | ±0.1% (≥1 g sample), ±0.02% (≥5 g sample) |
| Heating Temperature Range | 30–230 °C (1 °C increments) |
| Heating Modes | Standard, Rapid, Gentle, Step (3-stage, 0.1–999 min per stage) |
| Pre-stored Methods | 30 |
| Built-in Calibration Weight | Yes |
| GLP-Compliant Printing | Yes |
| Interface | RS-232C |
| Dimensions (W×D×H) | 350 × 453 × 156 mm |
| Weight | 8.0 kg |
| Brand | Denver |
|---|---|
| Origin | USA |
| Model | IR-35 |
| Maximum Sample Capacity | 35 g |
| Readability | 0.01% moisture |
| Sensor Resolution | 1 mg |
| Repeatability | ±0.2% (for 1–5 g initial sample), ±0.05% (for ≥5 g) |
| Heating Range | 40–160 °C (adjustable in 1 °C increments) |
| Heating Source | Long-life infrared metal tube heater with integrated reflector |
| Shut-off Modes | Automatic endpoint detection and timer mode (0.1–99 min) |
| Display Modes | % moisture, % dry weight, % ratio, residual mass (g) |
| Sample Chamber | Top-hinged lid with wide opening angle |
| Compliance | FDA/HACCP-compliant aluminum viewing panel (replaces glass), GLP-compliant reporting via RS-232C interface |
| Dimensions (W×D×H) | 224 × 366 × 191 mm |
| Net Weight | 5.8 kg |
| Data Storage | Single user-defined method |
| Interface | RS-232C for printer or PC connectivity |
| Brand | Denver |
|---|---|
| Origin | USA |
| Model | IR-60 |
| Maximum Sample Capacity | 60 g |
| Readability | 1 mg / 0.01% moisture |
| Repeatability | ±0.2% (for 1–5 g initial sample), ±0.05% (for ≥5 g initial sample) |
| Heating Range | 40–210 °C (1 °C increments) |
| Heating Source | Quartz infrared heater with quartz reflector plate |
| Programmable Heating Time | 0.1–99.9 min |
| Stored Methods | 5 user-defined protocols |
| Sample Pan Diameter | 90 mm |
| Calibration Weight | 50 g (E2 class) |
| Interface | RS-232C |
| Dimensions (W×D×H) | 213 × 320 × 181 mm |
| Net Weight | 5.1 kg |
| Brand | GBPI |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | W403C |
| Test Range | 0.001–100 g/m²·24h |
| Test Accuracy | 0.001 g/m²·24h |
| Temperature Control Range | 15–45°C (optional up to 60°C) |
| Temperature Control Accuracy | ±0.1°C |
| Humidity Control Range | 0% RH (dry), 30–90% RH, and 100% RH |
| Humidity Control Accuracy | ±1% RH |
| Permeation Area | 50.24 cm² (reducible to 0.785 cm² with optional fixtures) |
| Specimen Diameter | Φ100 mm |
| Specimen Thickness | ≤2 mm |
| Sample Capacity | 2 independent test chambers |
| Carrier Gas | ≥99.999% N₂ (user-supplied) |
| Gas Pressure | ≥0.1 MPa |
| Gas Flow Rate | 5–120 mL/min |
| Gas Inlet | 1/8″ metal tubing |
| Dimensions | 61 × 55 × 40 cm |
| Weight | 80 kg |
| Power | 750 W |
| Supply | AC 220 V, 50 Hz |
| Compliance Standards | GB/T 26253-2010, YBB 00092003-2015, BS EN ISO 15106-2:2005, ASTM F1249-2013, JIS K7129-2008 |
| Brand | Hengping |
|---|---|
| Origin | Shanghai, China |
| Model | LHS16-A |
| Readability | 0.001 g |
| Weighing Range | 0–100 g |
| Temperature Range | Ambient to 160 °C |
| Temperature Control Accuracy | ±1 °C |
| Moisture Content Readability | 0.01 % |
| Repeatability (≥2 g sample) | 0.2 % |
| Timer Range | 0–120 min |
| Sample Pan Diameter | Φ90 mm |
| Dimensions (W×D×H) | 235 × 195 × 195 mm |
| Power Supply | 220 V, 50 Hz or 110 V ±11 V, 60 Hz |
| Net Weight | 11.5 kg |
| Interface | RS232 |
| Display Parameters | 8 configurable parameters |
| Heating Modes | Manual / Automatic / Programmable |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Hexi |
|---|---|
| Origin | Hunan, China |
| Model | MW-3000 |
| Heating Method | Microwave (not infrared) |
| Measurement Range | 0–60% w/w |
| Resolution | 0.01% |
| Accuracy | ±1% |
| Display | TFT-LCD digital display |
| Sample Feed | Automated uniform feeder |
| Data Output | Digital, software-integrated |
| Compliance | Designed for GLP-compliant environments |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | 11521.1310.100 |
| Price | USD 105 (ex-works) |
| Brand | HOGON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HM Series |
| Heating Method | Halogen Lamp |
| Measurement Principle | Loss-on-Drying (LOD) via Halogen Radiant Heating |
| Weighing Range | 110 g |
| Weighing Resolution | 0.0001 g to 0.005 g (model-dependent) |
| Temperature Range | Ambient to 199 °C |
| Drying Modes | Standard / Rapid / Gentle |
| Preheating Time | < 60 s to 50–180 °C |
| Data Storage | 15 measurement records |
| Programs Stored | Up to 16 user-defined methods |
| Interface | RS-232 serial port |
| Compliance | GLP/GMP/GCP, ISO/IEC 17025-aligned operation, meets JJG 1084–2013 (Chinese National Metrological Verification Regulation for Moisture Analyzers) |
| Origin | Japan |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | F-50 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR120 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR35 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IR60 |
| Pricing | Available Upon Request |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | SFY-20 |
| Price | USD 1,890 (FOB Guangdong) |
| Weighing Range | 0–90 g |
| Moisture Measurement Range | 0.01–100% |
| Minimum Readability | 0.001 g |
| Sample Mass | 0.5–90 g |
| Heating Temperature Range | Ambient to 205 °C |
| Heating Method | Variable Hybrid Halogen Heating |
| Auto Temperature Compensation | ±15 °C |
| Moisture Resolution | 0.01% |
| Display Modes | 7 Parameters (Moisture %, Initial/Final Mass, Test Duration, Initial/Final Temp, Endpoint Detection Time) |
| Interface | Dual RS-232 (Printer & PC) |
| Dimensions (W×D×H) | 380 × 205 × 325 mm |
| Power Supply | 220 V ±10%, 50 Hz ±1 Hz |
| Net Weight | 3.7 kg |
| Brand | KETT |
|---|---|
| Origin | Japan |
| Model | RN-300 |
| Heating Method | Infrared |
| Sample Type | Brown Rice & Polished Rice (polished rice analysis requires optional accessories) |
| Image Sensor | Color CCD Camera |
| Light Source | White Cold-Cathode Fluorescent Lamp |
| Maximum Sample Capacity | 1,148 grains per measurement |
| Analysis Time | Approx. 24 seconds |
| Display | Grain-by-grain classification, count, percentage composition (by number and mass), length/width/projection area, typicality index, embryo retention rate (0 / ½ / full), crack detection |
| Power Supply | AC 100 V ±10%, 50/60 Hz |
| Dimensions (Transport) | 580 × 230 × 420 mm |
| Dimensions (Operation) | 840 × 580 × 115 mm |
| Weight | ~12 kg |
| Brand | KEWLAB |
|---|---|
| Model | MA113TA |
| Heating Source | Halogen Lamp |
| Capacity | 110 g |
| Readability | 0.001 g / 0.01% |
| Repeatability | ±0.002 g |
| Temperature Range | 40–230 °C |
| Timer Range | 1–99 min |
| Operating Environment | 5–35 °C |
| Interface | RS232, RJ45 Ethernet |
| Display | Large Capacitive Touchscreen |
| Power Supply | 220 V / 50 Hz |
| Dimensions (L×W×H) | 215 × 195 × 415 mm |
| Sample Pan Material | Precision Cast Aluminum |
| Chamber Material | Multi-layer Stainless Steel |
| Cooling | Dual Fan System |
| Connectivity | Wired (TA series) |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | PRC |
| Model | WS-1 |
| Price | Upon Request |
| Display | 4-digit LED, microgram (µg) resolution |
| Water Quantification Range | 5 µg – 30 mg H₂O |
| Detection Limit | 1 µg H₂O |
| Accuracy | ±3 µg for 5–1000 µg |
| Electrolysis Current | 0–300 mA (auto-controlled) |
| Power Supply | 220 V ±10%, 50 Hz ±5% |
| Power Consumption | <40 VA |
| Operating Temperature | 5–40 °C |
| Operating Humidity | ≤85% RH |
| Dimensions (W×D×H) | 450 × 230 × 200 mm |
| Weight | ~7 kg |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Type | Imported Instrument |
| Model | RC-612 |
| Heating Method | Infrared |
| Compliance | AWS A4.3 / ANSI/AWS A4.3, ASTM E1019 (carbon), ASTM E203 (moisture), ISO 11722, ISO 11723 |
| Optional Accessories | 50-position Autosampler, SmartLine® Remote Diagnostics, Analytical Balance Integration |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MA150 |
| Pricing | Upon Request |
| Capacity | 150 g |
| Readability | 1 mg |
| Moisture Resolution | 0.01% |
| Repeatability | ±0.2% (for initial sample mass ≥1 g) |
| Heating Temperature Range | 40–230 °C (adjustable in 1 °C increments) |
| Timer Range | 0.1–99 minutes |
| Heating Source | Ceramic IR Heater |
| Net Weight | 5.5 kg |
| Dimensions (W × L × H) | 213 × 320 × 180.5 mm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB35 |
| Price | USD 2,700 (FOB) |
| Capacity | 35 g |
| Readability | 0.001 g / 0.01% MC |
| Repeatability (SD) | ±0.18% @ 3 g sample |
| Moisture Range | 0.05–100% |
| Timer | 1–120 min (30-sec intervals ≤60 min |
| Temperature Range | 50–160 °C (5 °C increments) |
| Operating Ambient | 10–40 °C |
| Display | Backlit LCD, 128×64 dot matrix |
| Pan Diameter | 9 cm |
| Dimensions (W×H×D) | 19×15.2×36 cm |
| Interface | RS232 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB45 |
| Price | USD 3,980 (FOB) |
| Capacity | 45 g |
| Readability | 0.001 g / 0.01% MC |
| Repeatability | ±0.05% (3 g sample), ±0.015% (10 g sample) |
| Moisture Range | 0.01–100% (Regain Mode: 0.01–1000%) |
| Timer | 1–120 min (10-sec increments) |
| Temperature Range | 50–200 °C (1 °C increments) |
| Heating Programs | Standard, Rapid, Gentle, Stepwise |
| End Point Modes | Manual, Timed, Auto (3 programmable criteria) |
| Operating Ambient | 10–40 °C |
| Display | Backlit LCD, 128×64 dot matrix |
| Data Output | RS232 interface |
| GLP Compliance | Date/time stamp, shutdown mode, heating profile logging, operator ID support |
| Pan Diameter | 9 cm |
| Dimensions (W×H×D) | 19×15.2×36 cm |
| Weight | 3.2 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | HC103 |
| Heating Source | Halogen Lamp |
| Display | Capacitive Touchscreen |
| Construction | Stainless Steel Housing |
| Dimensions (W×D×H) | 210 × 340 × 180 mm |
| Weight | ~6.5 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Origin | Switzerland |
|---|---|
| Model | EM120 |
| Maximum Capacity | 124 g |
| Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost function (140% target temperature for first 3 min) |
| Termination Criteria | Automatic, semi-automatic (user-defined mass change per second), or time-based (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Stored Methods | 5 user-defined profiles |
| Security | Password-protected settings, physical lock slot |
| Interface | RS232 |
| Firmware Update | Network-enabled via PC connection |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HC103 |
| Readability | 0.01% MC |
| Repeatability (sd), 2 g sample | 0.1% MC |
| Repeatability (sd), 10 g sample | 0.015% MC |
| Moisture Content Range | 1–100% MC |
| Maximum Sample Weight | 101 g |
| Minimum Sample Weight | 0.1 g |
| Drying Temperature Range | 40–230 °C |
| Heating Profile Options | Standard, Rapid |
| Method Storage Capacity | 20 pre-programmed methods |
| Result Storage Capacity | 100 measurement records |
| Display Modes | %MC, %DC, %AM, %AD, g, g/kg MC, g/kg DC |
| Data Export | USB flash drive support |
| Leveling Assistance | Integrated bubble level + on-screen leveling wizard |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HC103 |
| Heating Source | Halogen Lamp |
| Compliance | Designed for GLP/GMP environments |
| Software Capability | Built-in method wizard, touch-screen interface, SmartCal performance verification |
| Sample Pan | Stainless steel, flat surface for rapid cleaning |
| Dimensions | Compact footprint (< 200 mm × 300 mm), robust metal housing |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | HC103 |
| Heating Source | Halogen Lamp |
| Readability | 0.01 % MC (1 mg) |
| Max Capacity | 101 g |
| Temperature Range | 40–230 °C (1 °C increment) |
| Repeatability | 0.1 % (2 g sample), 0.015 % (10 g sample) |
| Method Storage | 20 methods |
| Result Storage | 100 results |
| Display | 7" color touchscreen |
| Interfaces | RS232, USB |
| Compliance Support | GLP/GMP-ready data traceability, FDA 21 CFR Part 11-compatible reporting (via optional software) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HE53 |
| Heating Method | Halogen Lamp |
| Repeatability (sd) | 0.15 % at 2 g sample |
| Readability | 0.01 % MC |
| Moisture Range | 1.0 – 100 % MC |
| Drying Temperature Range | 50 – 160 °C |
| Temperature Increment | 1 °C |
| Heating Programs | Standard, Rapid |
| Memory | 1 method + 1 result |
| Display Modes | %MC, %DC, %AM, %AD, g |
| Max. Weighing Capacity | 54 g |
| Power Supply | 230 V |
| Part Number | 30100320 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HE53 |
| Heating Source | Halogen Lamp |
| Maximum Capacity | 54 g |
| Moisture Content Readability | 0.01 % (1 mg) |
| Repeatability (2 g sample) | 0.15 % (SD) |
| Repeatability (10 g sample) | 0.05 % (SD) |
| Drying Temperature Range | 50–160 °C |
| Temperature Increment | 1 °C |
| Predefined Drying Programs | Standard, Rapid |
| Method Storage | 1 method |
| Result Storage | 1 result |
| Display Modes | ATRO moisture %, ATRO solids %, mass (g), moisture %, solids % |
| Interface | RS232 |
| Language | English |
| Compliance | ASTM E1447, ISO 18810, USP <921>, GLP-compliant data handling |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | HE53 |
| Heating Source | Halogen Lamp |
| Readability | 0.01 % MC (1 mg) |
| Weighing Range | 54 g |
| Drying Temperature Range | 50–160 °C (1 °C increments) |
| Repeatability (2 g sample) | 0.15 % SD |
| Repeatability (10 g sample) | 0.05 % SD |
| Method Storage | 1 method |
| Result Storage | 1 result |
| Display Modes | ATRO moisture %, ATRO solids %, g, moisture %, solids % |
| Interface | RS232 |
| Compliance | SOC 3 auto-calibration at 100 °C / 160 °C |
| Power Supply | 230 V |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HE83 |
| Readability | 0.01% |
| Repeatability (sd, 2g sample) | 0.15% |
| Repeatability (sd, 10g sample) | 0.05% |
| Moisture Range | 1–100% MC |
| Sample Capacity | 81 g |
| Minimum Sample Mass | 0.5 g |
| Drying Temperature Range | 50–200 °C |
| Heating Profile Options | Standard, Rapid |
| Display Modes | %MC, %DC, %AM, %AD, g |
| Method Storage | 2 methods + 1 result |