| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | HE83 |
| Heating Source | Halogen Lamp |
| Weighing Range | 81 g |
| Readability | 1 mg |
| Temperature Range | 50–200 °C (adjustable in 1 °C increments) |
| Moisture Determination Accuracy | ±0.01% |
| Heating Uniformity | Enhanced via Gold-Coated Radiator |
| Calibration | Integrated Balance & Heater Calibration Routines |
| Method Development | Automated Three-Step Method Optimization |
| Security | Three-Tier Password Protection |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Shanghai, China |
| Model | HE83 / HE53 |
| Heating Source | Halogen Lamp |
| Type | Infrared Moisture Analyzer |
| Compliance Context | Designed for GLP/GMP-aligned routine QC labs |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HG63 |
| Temperature Range | 40–200 °C |
| Weight Readability | 1 mg |
| Moisture Content Readability | 0.01 % |
| Minimum Sample Weight | 0.1 g |
| Maximum Sample Weight | 61 g |
| Repeatability (2 g sample) | ±0.05 % |
| Repeatability (10 g sample) | ±0.01 % |
| Drying Programs | Standard & Rapid |
| Shut-off Criteria | 5-level automatic, manual, time-controlled |
| Stored Methods | Up to 10 |
| Interface | LocalCAN / optional RS232 |
| Display | Backlit LCD |
| Dimensions (W×D×H) | 360 × 340 × 110 mm |
| Net Weight | 7.7 kg (with built-in printer) |
| Languages | English, French, German, Italian, Russian, Spanish |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HS153 |
| Heating Source | Halogen Lamp |
| Moisture Content Readability | 0.01 % |
| Minimum Detectable Moisture Content | 0.5 % |
| Repeatability (2 g sample) | 0.05 % (std. dev.) |
| Repeatability (10 g sample) | 0.01 % (std. dev.) |
| Method Storage Capacity | 100 methods |
| Result Storage Capacity | 3,000 results |
| Drying Temperature Range | 40–230 °C (1 °C increment) |
| Max. Sample Capacity | 150 g |
| Display Modes | ATRO moisture %, moisture (g/kg), solids %, solids (g/kg), mass (g), ATRO solids % |
| Drying Programs | Slow, Standard, Fast |
| Auto-End Criteria | SOC 1–5 (standard), user-defined (1–10 mg loss or 5–300 s duration), user-defined % mass loss |
| Calibration & Test Temperatures | 100 °C / 160 °C |
| SmartCal Drying Temperature | 40 °C |
| Connectivity | USB, Ethernet/Wi-Fi, RS232 |
| Supported Languages | English, German, French, Spanish, Italian, Portuguese, Russian, Polish, Czech, Hungarian, Japanese, Korean, Chinese |
| Interface | Touchscreen with guided workflow, method shortcuts, real-time drying curve, control chart, ID management, result prediction, weighing assistance |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 |
| Weighing Range | 0.1 g – 200 g |
| Temperature Range | 40–230 °C |
| Readability | 1 mg (moisture content resolution 0.01%) / 0.1 mg (moisture content resolution 0.001%) |
| Repeatability (sd) | 0.05% (2 g sample) / 0.01% (10 g sample) |
| Heating Source | Second-generation halogen lamp |
| User Interface | Graphical One Click™ Moisture interface with real-time drying curve and control chart |
| Calibration | Fully automatic FACT™ (Frequency Automatic Calibration Technology) |
| Level Detection | Integrated horizontal sensor with visual/audible alert |
| Sample Pan Design | Suspended pan architecture with sealed, flat-bottom cavity |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 |
| Maximum Capacity | 200 g |
| Readability | 0.1 mg |
| Moisture Content Resolution | 0.001% |
| Repeatability (sd) | 0.01% (10 g sample) / 0.05% (2 g sample) |
| Temperature Range | 40–230 °C |
| Heating Source | Second-generation halogen lamp |
| Heating Control | Programmable ramp profiles (Standard, Gentle, Fast, Step) |
| Automatic Calibration | FACT® (Fully Automatic Calibration Technology) with dual-point temperature calibration and adjustable mass-point weighing calibration |
| Display Modes | % MC, % DC, % ATRO MC/DC, g, g/kg MC, g/kg DC |
| Sample chamber surface | Sealed, smooth, cleanable in ≤30 s |
| Weighing cell location | Rear-mounted, isolated from heating chamber |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 |
| Readability | 0.01% (moisture content) / 0.001 g |
| Repeatability (sd) | 0.05% (2 g sample), 0.01% (10 g sample) |
| Moisture Range | 0.01–100% MC |
| Heating Temperature Range | 40–230 °C |
| Weighing Capacity | 200 g |
| Minimum Sample Mass | 0.1 g |
| Drying Programs | Standard, Fast, Slow, Step |
| Method Storage | 300 methods |
| Result Storage | 3000 results |
| Display Modes | %MC, %DC, g, %AM, %AD, g/kg DC, g/kg MC |
| Data Output | A4/Letter print, PDF export, USB & Ethernet connectivity |
| Calibration | FACT (Fully Automatic Calibration Technology) with internal weights |
| Leveling | Integrated electronic level control |
| Performance Verification | SmartCal validation test substance |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion KF Flex / Pro |
| Sample Capacity | 24 positions |
| Heating Temperature Range | Up to 300 °C (programmable) |
| Gas Flow Control | Digital mass flow controller (air or inert gas) |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation |
| Interface | RS-232, USB, Ethernet (compatible with METTLER TOLEDO titration software tiamo™) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | InMotion KF Flex / Pro |
| Heating Method | Infrared |
| Sample Capacity | 24 positions on 25 cm footprint |
| Gas Flow Control | Digital mass flow meter (air or lab-line gas) |
| Temperature Program | Temperature ramping and isothermal scanning |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation (when paired with compatible titrators) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | MJ33 |
| Temperature Range | 50–160 °C |
| Min. Sample Weight | 0.5 g |
| Max. Sample Weight | 35 g |
| Repeatability (2 g) | ±0.15 % |
| Repeatability (10 g) | ±0.05 % |
| Readability (Moisture) | 0.01 % |
| Readability (Weight) | 1 mg |
| Drying Programs | 1 (Standard) |
| Switch-off Criteria | Automatic, Manual, Time-controlled |
| Display | Backlit LCD |
| Interface | RS232C |
| Languages | English, French, German, Italian, Spanish, Portuguese, Japanese, Russian |
| Dimensions (W×D×H) | 230 × 360 × 150 mm |
| Weight | 4.3 kg |
| Printer | External (optional) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 / HS153 / HB43 |
| Readability | 0.1 mg / 1 mg |
| Moisture Content Readability | 0.001% / 0.01% |
| Repeatability (sd, 2 g sample) | 0.05% / 0.05% / 0.10% |
| Repeatability (sd, 10 g sample) | 0.01% / 0.01% / 0.02% |
| Weighing Range | 200 g / 150 g / 54 g |
| Temperature Range | 40–230 °C / 40–230 °C / 50–230 °C |
| Heating Source | Second-generation halogen lamp |
| Calibration | FACT® automated temperature-triggered calibration (HX204 only) |
| Drying Programs | Standard, Gentle, Rapid, Step (HX204) |
| Method Storage | 300 / 99 / 100 |
| Real-time drying curve display | Yes / Yes / No |
| LevelControl™ | Active (HX204) / Visual indicator (HS153/HB43) |
| Compliance | Designed for GLP/GMP environments |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | HX204 / HS153 |
| Heating Source | Halogen Lamp |
| Maximum Sample Capacity | 200 g |
| Readability | 0.1 mg (HX204) |
| Compliance | ISO 8573-3, ASTM D4006, USP <921>, GLP/GMP-ready |
| Software | METTLER TOLEDO LabX™ (optional), One Click™ Moisture Interface |
| Cleaning Time | ≤30 s |
| Sensor Architecture | Monobloc Weighing Cell with Suspended Pan Design |
| Brand | Mitsubishi Chemical |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Method Type | Single-Channel Coulometric |
| Detection Range | 10 µg – 100 mg H₂O |
| Average Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Electrolysis Current | 430 mA |
| Precision | ≤0.3% RSD (for samples ≥1 mg H₂O, n=10) |
| Data Storage | 20 standalone methods + 50 composite methods |
| Display | 5.7-inch full-color LCD |
| Interfaces | RS-232C (optional), dual USB ports (data export & printer), internal balance auto-input support |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Power Consumption | 80 VA (100–120 V), 310 VA (230–240 V) |
| Dimensions (Main Unit) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| Stirrer Dimensions | 120 × 180 × 148 mm |
| Weight | ~1 kg |
| Compliance | GLP/GMP-ready architecture, 21 CFR Part 11-compatible software available (optional) |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Measurement Range | 10 µg – 100 mg H₂O |
| Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Electrolysis Current | 430 mA |
| Precision | CV ≤ 0.3% for samples ≥ 1 mg H₂O (n = 10) |
| Display | 5.7-inch color LCD |
| Sample Capacity | Up to 33 samples with optional auto-sampler |
| Data Storage | 20 user-defined methods, each supporting 50 sub-files |
| Interface | RS-232C (optional), USB port for data export, balance input, internal/external communication ports |
| Power Supply | AC 100–120 V or 230–240 V, 50/60 Hz |
| Power Consumption | 80 VA (100–120 V), 310 VA (230–240 V) |
| Dimensions (Analyzer) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| Stirrer Dimensions | 120 × 180 × 148 mm |
| Weight | ~1 kg |
| Brand | MITSUBISHI CHEMICAL |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Method Type | Single-Channel |
| Measurement Range | 10 µg – 100 mg H₂O |
| Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Electrolysis Current | 430 mA |
| Precision | CV ≤ 0.3% for samples ≥ 1 mg H₂O (n = 10) |
| Data Storage | 20 individual files + 50 composite files |
| Display | 5.7-inch color LCD |
| Interfaces | RS-232C (optional), USB host (2 ports), internal balance input (auto-weighing), dedicated USB storage port |
| Power Supply | AC 100–120 V / 230–240 V, 50/60 Hz |
| Power Consumption | 80 VA (100–120 V), 310 VA (230–240 V) |
| Dimensions (Main Unit) | 220 × 350 × 360 mm (W×D×H) |
| Weight | ~5 kg |
| Stirrer Dimensions | 120 × 180 × 148 mm |
| Weight | ~1 kg |
| Compliance | GLP/GMP-supporting architecture, audit-ready data handling |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MM500 |
| Pricing | Available Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MMS-4000 |
| Pricing | Available Upon Request |
| Brand | Nittoseiko Analytech |
|---|---|
| Origin | Japan |
| Model | CA-200 |
| Detection Principle | Coulometric Karl Fischer Titration |
| Electrolysis Current | 430 mA |
| Titration Speed | 2.2 mg H₂O/min (36 µg H₂O/sec) |
| Measurement Range | 10 µg – 100 mg H₂O |
| Sensitivity | 0.1 µg H₂O |
| Precision | ±3 µg (for 10 µg–1 mg H₂O) |
| Cell Capacity | 150 mL |
| Display | 5.7-inch color LCD |
| Data Storage | ~100 recent measurements |
| File Capacity | 20 standard files + 50 composite files |
| Stirring | Magnetic stirring |
| Power Supply | AC 220/240 V, 50/60 Hz, 310 VA |
| Operating Environment | 5–40 °C, ≤85% RH (non-condensing) |
| Dimensions (Analyzer) | 330 × 320 × 148 mm |
| Weight (Analyzer) | ~5 kg |
| Compliance | GLP-supporting architecture, audit-ready data handling, 21 CFR Part 11-compatible optional software modules |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB120 |
| Heating Method | Halogen Lamp |
| Capacity | 120 g |
| Readability | 0.01% / 0.001 g |
| Repeatability | 0.05% (3 g sample) / 0.015% (10 g sample) |
| Moisture Range | 0.01–100% (Moisture), 0.01–1000% (Regain) |
| Temperature Range | 40–230 °C |
| Display | 4.3″ QVGA TFT Color Touchscreen |
| Sample Pan Diameter | 90 mm |
| Dimensions (W×H×D) | 211 × 180 × 355 mm |
| Net Weight | 5.23 kg |
| Power Supply | 240 VAC, 50/60 Hz |
| Interface | RS232 (2 ports), USB Host (2 ports), USB Device |
| Operating Environment | 10–40 °C |
| Brand | OHAUS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | MB120 |
| Heating Source | Halogen Lamp |
| Maximum Heating Temperature | 230 °C |
| Drying Modes | 4 configurable (Standard, Rapid, Step, Gentle) |
| Shut-off Criteria | Customizable (Time-based, Slope-based, Fixed Weight Loss, or Final Moisture Target) |
| Method Storage Capacity | Up to 100 user-defined methods |
| Result Storage Capacity | Up to 1,000 measurement records |
| Data Export | USB flash drive export to CSV/Excel-compatible format |
| User Management | 4-tier role-based access control (Administrator, Supervisor, Technician, Operator) |
| Compliance Support | Designed to support GLP/GMP documentation workflows |
| Brand | OHAUS |
|---|---|
| Model | MB23 |
| Heating Source | Infrared |
| Capacity | 110 g |
| Readability | 0.01 g |
| Moisture Readability (for >10 g sample) | 0.1% |
| Repeatability (3 g sample) | 0.3% |
| Repeatability (10 g sample) | 0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s increments), 60–90 min (1 min increments) |
| End-Point Detection | Timed & Automatic |
| Display | Moisture %, Solid %, Weight, Time, Temperature |
| Communication | Bidirectional RS232 |
| Operating Ambient | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.15 kg |
| Pan Handle | Standard |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB23 |
| Capacity | 110 g |
| Readability | 0.01 g |
| Moisture Readability (≥10 g sample) | 0.1% |
| Repeatability (3 g sample) | 0.3% |
| Repeatability (10 g sample) | 0.2% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | Ø90 mm |
| Heating Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s increments), 60–90 min (1 min increments) |
| Endpoint Detection | Timed or Automatic |
| Display | Moisture %, Solid %, Weight, Time, Temperature |
| Interface | Bidirectional RS232 |
| Operating Ambient Temperature | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.15 kg |
| Heating Source | Infrared Halogen Lamp |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB23 |
| Heating Method | Infrared (MB23/MB25) / Halogen (MB35/MB45) |
| Moisture Range | 0.01–100% (MB35/MB45, standard mode) |
| Readability | 0.01 g (MB23/MB25), 0.001 g / 0.01% (MB35/MB45) |
| Repeatability | ±0.015% (10 g sample, MB45), ±0.05% (10 g sample, MB35), ±0.2% (3 g sample, MB23), ±0.05% (3 g sample, MB45) |
| Temperature Range | 50–160 °C (MB23/MB25), 50–200 °C (MB35/MB45), adjustable in 1 °C or 5 °C increments |
| Timer Range | 1–120 min (MB35/MB45: 10 s resolution up to 60 min |
| MB23/MB25 | 30 s up to 60 min) |
| Pan Diameter | 90 mm |
| Communication | Bidirectional RS232 |
| Compliance | GLP-compliant data logging and print output |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Heating Method | Infrared |
| Maximum Capacity | 110 g |
| Readability | 0.01 g |
| Moisture Readability (for >10 g sample) | 0.1% |
| Repeatability (SD) | 0.3% for 3 g sample, 0.2% for 10 g sample |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s steps), 60–90 min (1 min steps) |
| Endpoint Control | Timed & Automatic |
| Display | Backlit LCD showing moisture %, solids %, weight, time, temperature |
| Interface | Bidirectional RS232 |
| Operating Environment | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Sample Pan Handle | Standard |
| Heating Source | Infrared Lamp |
| Origin | USA |
|---|---|
| Type | Imported Instrument |
| Model | MB25 |
| Capacity | 110 g / 99 g |
| Readability | 0.01 g / 0.005 g |
| Readability (for samples >10 g) | ±0.05% |
| Repeatability (3 g sample) | ±0.2% |
| Repeatability (10 g sample) | ±0.05% |
| Heating Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30-sec increments), 60–90 min (1-min increments) |
| Sample Pan Diameter | 90 mm |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Operating Ambient Temperature | 10–30 °C |
| Communication Interface | Bidirectional RS232 |
| Display Content | Moisture %, Solid %, Weight, Time, Temperature |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Heating Source | Halogen Lamp |
| End-point Detection | Timed or Automatic |
| Built-in Sample Pan Handle | Standard |
| Brand | OHAUS |
|---|---|
| Model | MB25 |
| Heating Source | Halogen Lamp |
| Capacity | 110 g / 99 g (max. weight / max. moisture loss) |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05% |
| Repeatability (3 g sample) | 0.2% |
| Repeatability (10 g sample) | 0.05% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Heating Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s steps), 60–90 min (1 min steps) |
| Endpoint Modes | Timed & Automatic |
| Display | Moisture %, Solid %, Weight (g), Time (min:s), Temperature (°C) |
| Interface | Bidirectional RS232 |
| Operating Ambient | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Standard Features | Backlit LCD, Integrated Sample Pan Handle, Thermal-Isolation Weighing Sensor Architecture |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MB25 |
| Price | USD 1,390 (FOB US Port) |
| Capacity | 110 g / 99 g |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05 % |
| Repeatability (3 g sample) | 0.2 % |
| Repeatability (10 g sample) | 0.05 % |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Heating Program | Standard |
| Operating Ambient Temperature | 10–30 °C |
| Communication Interface | Bidirectional RS232 |
| Endpoint Detection | Timer-based & Auto-termination |
| Heating Temperature Range | 50–160 °C (in 5 °C increments) |
| Display Parameters | Moisture %, Solid %, Mass (g), Time (min:s), Temperature (°C) |
| Drying Time Range | 1–60 min (30 s increments) |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Sample Pan Handle | Included |
| Heating Source | Halogen Lamp |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB25 |
| Capacity | 110 g / 99 g (moisture mode) |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05% |
| Repeatability (3 g sample) | 0.2% |
| Repeatability (10 g sample) | 0.05% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | Ø90 mm |
| Heating Source | Halogen lamp |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s increments), 60–90 min (1 min increments) |
| End Point Modes | Timed, Automatic |
| Display | Backlit LCD showing moisture %, solids %, weight, time, temperature |
| Interface | Bidirectional RS232 |
| Operating Environment | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Gross Weight | 4.2 kg |
| Sample Pan Handle | Standard |
| Brand | OHAUS |
|---|---|
| Origin | USA |
| Model | MB25ZH |
| Heating Source | Halogen Lamp |
| Capacity | 110 g / 99 g (max. sample weight) |
| Readability | 0.01 g / 0.005 g |
| Moisture Readability (>10 g sample) | 0.05% |
| Repeatability (3 g sample) | 0.2% |
| Repeatability (10 g sample) | 0.05% |
| Minimum Sample Mass | 0.5 g |
| Recommended Sample Mass | 3–20 g |
| Pan Diameter | 90 mm |
| Temperature Range | 50–160 °C (in 5 °C increments) |
| Heating Time | 1–60 min (30 s steps), 60–90 min (1 min steps) |
| End Point Detection | Timed & Automatic |
| Display | Backlit LCD showing moisture %, solids %, mass, time, temperature |
| Interface | Bidirectional RS232 |
| Operating Ambient | 10–30 °C |
| Dimensions (W×H×D) | 165 × 127 × 280 mm |
| Net Weight | 2.1 kg |
| Sample Pan Handle | Standard |
| Key | Brand: OHAUS |
|---|---|
| Origin | USA |
| Heating Source | Halogen Lamp |
| Max Capacity | 90 g |
| Readability | 1 mg / 0.01% moisture |
| Pan Diameter | 90 mm |
| Temperature Range | 50–160 °C |
| Display | Dual-line backlit LCD |
| Interface | RS232 |
| Dimensions (H×L×W) | 130 × 280 × 170 mm |
| Net Weight | 2.1 kg |
| Power Supply | AC adapter (included) |
| Auto-termination Modes | Fixed weight loss, time-based, manual |
| Measurement Units | % moisture, grams |
| Operating Environment | 10–40 °C, ≤80% RH (non-condensing) |
| Compliance | GLP-compliant data output |