Ion Detectors
Filter
Showing 151–180 of 216 results
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Quartz Crystal Microbalance (QCM) with Gold-Plated Fluoride-Specific Sensor Chip |
| Measurement Sensitivity | 1 ng/Hz @ 10 MHz |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Regulatory Compliance | Designed for ISO 10523, ASTM D4192, and EPA Method 300.0–compatible workflows |
| Software Interface | USB-C–enabled embedded firmware with real-time data streaming and CSV export |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Endotoxin Detection System |
| Instrument Type | Portable |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microfluidic Sensor Chip |
| Sensitivity | 0.00742 EU/mL |
| Channel Configuration | Single-, Dual-, or Multi-Channel Options Available |
| Compliance | Designed to support USP <85>, EP 2.6.14, and ISO 11737-1 workflows |
| Sample Format | Aqueous liquid samples only |
| Power Supply | Rechargeable Li-ion battery (≥8 h continuous operation) |
| Data Interface | USB-C & Bluetooth 5.0 |
| Software Platform | MIPS EndoTrack™ v3.2 (Windows/macOS compatible) |
| Brand | MIPS |
|---|---|
| Origin | Singapore |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIPS Pesticide Detection System |
| Instrument Type | Multi-Ion Analyzer |
| Detection Principle | Electrochemical Impedance Spectroscopy (EIS) with Functionalized Gold-Quartz Microsensor Chips |
| Sample Matrix | Aqueous Solutions |
| Configurations | Single-, Dual-, or Multi-Channel Options Available |
| Integrated Components | Micro-peristaltic Pumps, Multi-Functional Microfluidic Analysis Chamber, Embedded Signal Processing Unit |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MP523-03 |
| Price | USD 920 (FOB Shanghai) |
| Instrument Type | Multi-Ion Meter |
| pH Range | −2.000 to 19.999 |
| pH Accuracy | ±0.002 pH |
| pH Temp. Compensation | 0–100 °C |
| pCa Range (Meter) | 0.00–9.00 pCa |
| pCa Range (with Electrode) | 1.00–7.00 pCa |
| pCa Accuracy | ±0.01 pCa |
| pCa Temp. Compensation | 0–50 °C |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Range | −10 to 110 °C |
| Temp. Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | MP523-04 |
| Price | USD 920 (FOB Shanghai) |
| Instrument Type | Fluoride-Specific Ion Meter |
| pH Range | −2.000–19.999 |
| pH Accuracy | ±0.002 pH |
| Fluoride pF Range (Meter) | 0.00–9.00 pF |
| Fluoride pF Range (with Electrode Pair) | 1.00–7.00 pF |
| Fluoride Accuracy | ±0.01 pF |
| Temperature Compensation | 0–50 °C (for F⁻) |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temp. Range | −10–110 °C |
| Temp. Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| GLP Compliance | Yes |
| Brand | Rikari Chemical |
|---|---|
| Origin | Japan |
| Model | Ni-502L |
| Instrument Type | Portable Multi-Ion Analyzer |
| Measurement Range | 0.0–199.9 g/L Ni |
| Detection Limit | 0.01 g/L Ni |
| Response Time | ≤20 s |
| Accuracy | ±2% of Full Scale (FS) |
| Operating Temperature | 0–50 °C |
| Sensor Material | FEP and PVC (chemically resistant) |
| Measurement Modes | Nickel Concentration (g/L), Absorbance (Abs), User-Defined Calibration (e.g., NiSO₄ concentration, molarity) |
| Brand | Ocean Optics |
|---|---|
| Origin | USA |
| Model | PlasCalc |
| Spectral Range | 200–1100 nm |
| Optical Resolution | 1.0 nm (FWHM) |
| A/D Conversion | 14-bit |
| Digital I/O | 8 × TTL |
| Analog Outputs | 4 × [0–10 V] |
| Interface | USB 1.1 |
| Power Supply | 12 VDC @ 1.25 A |
| Measurement Speed | ≤3 ms per spectrum |
| Ion Detection Capability | Multi-ion (indirect via spectral emission analysis) |
| Brand | Online Instrument |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OL2010N |
| Instrument Type | Benchtop |
| Ion Detection Capability | Multi-ion |
| Measurement Range | 0.05–2 mg/L |
| Limit of Detection (LOD) | 0.01 mg/L |
| Response Time | Real-time |
| Measurement Accuracy | ±2% |
| Operating Temperature Range | 5–35 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 410P-06 |
| Price | Upon Request |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Models | PFS-80 (Benchtop), PFP-208 (Portable) |
| Measurement Range | 0–6.00 pF |
| Accuracy | ±0.02 pF |
| Temperature Compensation Range | 0–60 °C |
| pH Measurement Range | 0.00–14.00 (±0.01) |
| mV Range | ±1999 mV (±0.1%) |
| Output Signal | –1999 to +1999 mV |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Battery | 9 V (6F22) |
| Net Weight | 1.8 kg (PFS-80), 0.5 kg (PFP-208) |
| Stability | ±0.01 pF/30 min |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Models | PnaS-50 (Benchtop), PnaP-205 (Portable) |
| Measurement Range | 0–6.00 pNa |
| Accuracy | ±0.02 pNa |
| Temperature Compensation Range | 0–60 °C |
| pH Range | 0.00–14.00 ±0.01 |
| mV Range | ±1999 mV ±0.1% |
| Output Signal | –1999 to +1999 mV |
| Power Supply | AC 220 V ±10%, 50/60 Hz (PnaS-50) |
| Net Weight | 1.8 kg (PnaS-50), 0.5 kg (PnaP-205) |
| Stability | ±0.01 pNa/24 h |
| Brand | Riken Keiki |
|---|---|
| Origin | Japan |
| Model | CL-502 |
| Instrument Type | Online Analyzer |
| Measurement Principle | Solid-State Membrane Chloride-Selective Electrode (CSE) |
| Measuring Range | 10–1000 mg/L (customizable up to >1000 mg/L) |
| Detection Limit | 1 mg/L |
| Response Time | ≤1 s |
| Accuracy | ±1% of full scale |
| Repeatability | ±2% FS |
| pH Operating Range | 3.0–10.0 |
| Output Signal | Isolated DC 4–20 mA (load ≤500 Ω, three selectable ranges: 0–100 / 0–500 / 0–1000 mg/L) |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Operating Environment | 0–40 °C, ≤85% RH |
| Dimensions | 96 W × 96 H × 163 D mm |
| Weight | ~1.3 kg |
| Compliance | Designed for continuous industrial water monitoring per ISO 5667-3 and ASTM D3370 guidelines |
| Electrode Configuration | Dual-junction reference electrode with solid-state chloride-selective membrane, maintenance-free internal electrolyte |
| Brand | Riken Keiki |
|---|---|
| Model | F-10Z |
| Type | Portable Fluoride-Specific Ion Analyzer |
| Measurement Principle | Solid-State Lanthanum Fluoride (LaF₃) Single-Crystal Membrane Electrode |
| Measuring Range | 0–2000 mg/L F⁻ |
| Detection Limit | 1 mg/L F⁻ |
| Resolution | 0.1 mg/L (0.1–99.9 mg/L), 1 mg/L (100–2000 mg/L) |
| Accuracy | ±1% of reading |
| Response Time | ≤10 s (t₉₀) |
| Temperature Compensation | Automatic, semiconductor-based (0–45 °C) |
| Display | 4-digit LCD (F⁻: mg/L |
| mV | −1000 to +1000 mV) |
| Reproducibility | ±2 mg/L (≤99.9 mg/L), ±5 mg/L (100–2000 mg/L) |
| Calibration | Two-point using certified F⁻ standards (2 mg/L and 200 mg/L) |
| Memory Capacity | 30 measurement records |
| Ingress Protection | IP67 |
| Power Supply | DC 4.5 V (3 × AAA LR03 batteries) |
| Auto-Power-Off | After 30 min idle |
| Dimensions | 70 × 36 × 170 mm (W × H × D) |
| Weight | ~290 g (incl. batteries) |
| Housing Material | ABS plastic |
| Compliance | RoHS-compliant, lead-free soldering |
| Brand | Rikorika |
|---|---|
| Origin | Japan |
| Model | CL-11Z |
| Instrument Type | Portable |
| Measurement Range | 0–2000 mg/L (ppm) Cl⁻ |
| Detection Limit | 0.1 mg/L |
| Response Time | 1 s |
| Accuracy | ±2% of reading |
| Temperature Compensation | Automatic (NTC thermistor) |
| Operating Temperature | 0–45 °C |
| IP Rating | IP67 |
| Display | 4-digit LCD with backlight |
| Resolution | 0.1 mg/L (0.1–99.9 mg/L), 1 mg/L (100–2000 mg/L) |
| Repeatability | ±2 mg/L (0.1–99.9 mg/L), ±5 mg/L (100–2000 mg/L) |
| Memory Capacity | 30 data points |
| Dimensions (main unit) | 70 × 40 × 173 mm (W × H × D) |
| Weight (main unit + electrode + 1 m cable) | ~430 g |
| Standard Accessories | CLD-11 chloride-selective electrode, CLSLN-10-50 & CLSLN-1000-50 standard solutions (50 mL each), CLDLQ-30 internal filling solution (30 mL), two syringes, ISAB solution (50 mL), user manual, warranty card, AA batteries |
| Brand | Rikuri |
|---|---|
| Origin | Japan |
| Model | NI-502 |
| Instrument Type | Online Multi-Ion Analyzer |
| Measurement Principle | Absorption Photometry (Visible Spectrophotometric Detection at Characteristic Wavelength) |
| Measurement Range | 0–199.9 g/L (High Range) / 0.00–19.99 g/L (Low Range) |
| Detection Limit | 1 g/L |
| Resolution | 0.1 g/L (High Range), 0.01 g/L (Low Range) |
| Accuracy | ±2% FS |
| Response Time | ≤1 s |
| Output Signal | Isolated 4–20 mA DC (3-Stage Range Selection) |
| Alarm Outputs | Dual SPDT Dry Contacts (AC 200 V, 1 A resistive load max) |
| Operating Environment | 0–40 °C, ≤85% RH |
| Power Supply | AC 85–240 V, 50/60 Hz |
| Sensor Options | High-Temperature Flow-Cell Sensor (for plating bath immersion) or Ambient-Temperature Immersion Probe |
| Compliance | Designed for continuous industrial process monitoring in electroplating and semiconductor wet processing lines |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop Sodium Ion Analyzer |
| Measurement Range (Meter) | 0.00–9.00 pNa |
| (with配套 electrode system) | 1.00–7.00 pNa |
| Accuracy (Meter) | ±0.01 pX |
| (System) | ±0.02 pX |
| Temperature Range | −10 °C to 110 °C |
| Detection Limit (Static) | ≥2 ppb Na⁺ |
| (Dynamic) | ≥0.2 ppb Na⁺ |
| Units | pNa, mol/L, mg/L, ppm |
| Temperature Compensation | 0–50 °C |
| mV Range | ±1999.9 mV |
| Resolution | 0.1 mV |
| Accuracy | ±0.1% FS |
| Temp Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (elsewhere) |
| Data Storage | 600 entries |
| Interface | RS232 |
| Power | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture, supports audit-ready data logging |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Ion Measured | Fluoride (F⁻) |
| Measurement Range (Meter) | 0.00–9.00 pF |
| Measurement Range (with Electrode Pair) | 1.00–7.00 pF |
| Accuracy (Meter) | ±0.01 pF |
| Accuracy (Electrode System) | ±0.02 pF |
| Temperature Range | −10 °C to 110 °C |
| Temperature Compensation Range | 0 °C to 50 °C |
| mV Range | ±1999.9 mV |
| mV Resolution | 0.1 mV |
| mV Accuracy | ±0.1% FS |
| Temperature Accuracy | ±0.5 °C (5–60 °C), ±1.0 °C (other ranges) |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant design, dust- and splash-resistant enclosure |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Model | MP523-01 |
| Instrument Type | Benchtop |
| Measurement Range | pH: −2.000–19.999 |
| Ion Concentration | 0.00–14.00 pX (equivalent to 0.01 mg/L–1000 mg/L depending on ion valence and selectivity) |
| Temperature | −10–110 °C |
| Detection Limit | 0.01 mg/L (typical for monovalent ions) |
| Response Time | ≤60 s (for ion concentration stabilization) |
| Accuracy | pH: ±0.002 pH |
| Ion | ±0.5% of reading (monovalent), ±1.0% of reading (divalent) |
| Temperature | ±0.4 °C |
| Temperature Compensation | Automatic, 0–100 °C (pH), 0–60 °C (ion) |
| Data Storage | 900 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions & Weight | 160 × 190 × 70 mm / 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture with audit-trail-capable data logging |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Model | MP523-02 |
| Ion Type | Sodium |
| Measurement Range (pNa) | 0.00–9.00 pNa (electrometer) |
| Detection Limit | ≥0.2 ppb (dynamic mode), ≥2 ppb (static mode) |
| Accuracy | ±0.01 pNa |
| Temperature Compensation | 0–50 °C |
| Data Storage | 600 sets |
| Interface | RS232 |
| Power Supply | DC 9 V / 300 mA |
| Dimensions | 160 × 190 × 70 mm |
| Weight | 880 g |
| IP Rating | IP54 |
| Compliance | GLP-compliant architecture, supports audit-ready data logging |
| Brand | Sanxin Peirui |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | WS200 |
| Instrument Type | Portable |
| Fluoride Ion Measurement Range | 1.00–6.00 pF |
| Detection Limit | 1.00–6.00 pF |
| Response Time | 5 s |
| Fluoride Accuracy | ±0.01 pF |
| Temperature Range | 0–80 °C |
| pH Range | 0.00–14.00 |
| pH Accuracy | ±0.01 pH |
| ORP Range | ±1999 mV |
| ORP Accuracy | ±0.1% FS |
| Conductivity Range | 0–199.9 mS/cm |
| TDS Range | 0–100 g/L |
| Salinity Range | 0–100 ppt |
| Resistivity Range | 0–100 MΩ·cm |
| Conductivity Accuracy | ±1.0% of reading |
| Temperature Compensation | Automatic (0–80 °C for F⁻ |
| Electrode Constants | 0.1 / 1.0 / 10 cm⁻¹ |
| Reference Temperatures | 18 °C, 20 °C, 25 °C |
| Data Storage | 200 sets (ID, value, unit, temperature) |
| Power | 2 × AA batteries (1.5 V each) |
| Dimensions (meter) | 65 × 120 × 31 mm |
| Weight (meter) | 186 g |
| Carrying Case | 255 × 210 × 50 mm / 1.7 kg |
| Ingress Protection | IP57 |
| Brand | SANXIN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Portable |
| Fluoride Measurement Range | 1.00–6.00 pF |
| Detection Limit | 1.00–6.00 pF |
| Response Time | 5 s |
| Fluoride Accuracy | ±0.01 pF |
| Temperature Range | 0–80 °C |
| pH Range | 0.00–14.00 |
| pH Accuracy | ±0.01 |
| ORP Range | ±1999 mV |
| ORP Accuracy | ±0.1% FS |
| Data Storage | 200 sets |
| Power | 2 × AA batteries (1.5 V) |
| Dimensions (meter) | 65 × 120 × 31 mm |
| Weight (meter) | 180 g |
| IP Rating | IP57 |
| Brand | Sanxin |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | YD200 |
| Price | USD 560 (FOB Shanghai) |
| Measurement Principle | Potentiometric Ion-Selective Electrode (ISE) Method |
| Primary Analytes | Total Ca²⁺ and Mg²⁺ ions |
| Calibration Solutions | B1/B2/B3 standard buffers |
| Output Interface | RS232 serial port |
| Display | Backlit LCD with dual-unit real-time readout |
| Temperature Range | 0.0–60.0 °C (adjustable in °C/°F) |
| Hardness Units | mmol/L, mg/L (CaCO₃), mg/L (CaO), mmol/L (Boiler), mg/L (Ca) |
| GLP Compliance | Yes — automatic timestamped calibration logging, electrode history tracking, user ID support |
| Brand | Sea-Bird Scientific |
|---|---|
| Manufacturer | Satlantic (Canada) |
| Model | SUNA V2 |
| Detection Principle | In-Situ Ultraviolet Spectroscopy (ISUS) |
| Measurement Target | Nitrate-N (NO₃⁻) |
| Form Factor | Submersible, Online-Ready |
| Path Length Options | 5 mm or 10 mm |
| Detection Range | 0.5–4000 µM (0.007–56 mg/L as N) |
| Accuracy | ±2 µM (10 mm) / ±4 µM (5 mm) or ±10% |
| Short-Term Precision (3σ) | 0.3 µM (freshwater/seawater T-S corrected) |
| Long-Term Drift | ≤0.3 µM/h (T-S corrected) |
| Turbidity Tolerance | 625 NTU (10 mm), 1250 NTU (5 mm) |
| Wavelength Range | 190–370 nm |
| Lamp Lifetime | 900 h |
| Operating Voltage | 8–18 VDC (8–15 VDC with biowiper) |
| Power Consumption | 7.5 W (0.625 A @ 12 V) |
| Housing Material | Titanium / Acetal |
| Maximum Depth Rating | 500 m (100 m with biowiper) |
| Weight | 2.5 kg (3.1 kg with biowiper) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | PANIS-270 |
| Instrument Category | Multi-Ion Analyzer |
| Form Factor | Portable |
| Measurement Range | 0.01–1.00 mg/L (dilution applicable for higher concentrations) |
| Detection Limit | Not specified numerically in source documentation |
| Response Time | 20 minutes per sample |
| Accuracy | ≤ ±5% of Full Scale (F.S.) |
| Repeatability | ≤ 3% RSD |
| Optical Stability | Absorbance drift < 0.002 A within 20 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤ 85% RH |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 0.5 Hz |
| Dimensions (H×W×D) | 130 × 266 × 200 mm |
| Weight | < 1.0 kg |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Domestic |
| Model | PCHCL-225 |
| Instrument Type | Portable |
| Measurement Range | 0.20–10.00 mg/L |
| Detection Limit | 0.20 mg/L |
| Response Time | 20 min |
| Accuracy | ≤ ±5% |
| Repeatability | ≤ 3% |
| Optical Drift | < 0.002 A within 20 min |
| Operating Temperature | 5–40 °C |
| Relative Humidity | ≤ 85% |
| Power Supply | 4 × AA batteries |
| Dimensions | 80 mm × 230 mm × 55 mm |
| Weight | 500 g |
| IP Rating | IP65 |
| Data Storage | 20 calibration curves + 199 timestamped measurements (including absorbance, transmittance, and concentration with yyyy-mm-dd hh:mm:ss) |
| Brand | Shenchanghong |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | TANIS-270 |
| Instrument Category | Multi-Ion Analyzer |
| Form Factor | Benchtop |
| Measurement Range | 0.01–1.00 mg/L (dilution applicable for higher concentrations) |
| Detection Limit | 0.01 mg/L |
| Response Time | ≤20 min |
| Accuracy | ±5% of Full Scale (F.S.) |
| Operating Temperature | 5–35 °C |
| Dimensions | 340 × 250 × 130 mm |
| Weight | 1.0 kg |
| Power Supply | AC 220 V ± 10%, 50 Hz ± 1% |
| Environmental Operating Conditions | Ambient temperature 5–40 °C |
| Brand | Sherwood |
|---|---|
| Origin | United Kingdom |
| Model | M926, M926S |
| Instrument Type | Benchtop Chloride Analyzer |
| Detection Principle | Coulometric Titration (Silver Nitrate Electrolytic Generation) |
| Sample Volume | M926: 500 µL |
| M926S | 20 µL |
| Measurement Range | M926: 10–999 mg/L Cl⁻ (equivalent to 2–165 mg% NaCl) |
| M926S | 10–299 mmol/L Cl⁻ |
| Detection Limit | 10 mg/L Cl⁻ (M926) |
| Response Time | ≤36 s (typical endpoint detection) |
| Accuracy | M926: ±3 mg/L or <1% RSD at 0.1% Cl⁻ |
| M926S | ±2% at 100 mmol/L Cl⁻ |
| Linearity | ≤1% deviation across full range |
| Repeatability (CV, n=20) | <1.5% at mid-range concentration |
| Temperature Control | Integrated ambient-temperature-stabilized cell compartment |
| Compliance | Designed for GLP/GMP environments |
| Brand | Starwood |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Manufacturer |
| Model | IM2021-1 |
| Instrument Type | Benchtop |
| Ion Measured | Fluoride (F⁻) |
| pH Range | 0.00–14.00 |
| mV Range | −1999.9 to +1999.9 mV |
| Detection Limit | 0.01 ppm (as F⁻) |
| Response Time | ≤2 s |
| pH Resolution | 0.01 |
| Temperature Operating Range | 5–40 °C |
| Power Supply | AC 220 V, 100 W |
| Brand | Thermo Fisher |
|---|---|
| Origin | Singapore |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Ion 6+ |
| Price | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | D10P-02 |
| Electrode | 9502BNWP CO₂ Gas-Sensing Electrode |
| CO₂ Range | 4.4–440 ppm |
| pH Operating Range | 4.8–5.2 |
| Temperature Range | 0–50°C |
| Reproducibility | ±2% |
| Electrode Dimensions | 151 mm (L) × 17 mm (body Ø) × 22 mm (cap Ø) |
| Cable Length | 75 cm |
| Dual Channel Meter | pH/ISE Mode |
| pH Range | −2.000 to 19.999 |
| pH Resolution | 0.001 |
| pH Accuracy | ±0.001 |
| ISE Range | 0–19999 (units: ppm, mg/L, M, %, or unitless) |
| ISE Accuracy | ±0.1 mV or ±0.05% (whichever is greater) |
| ORP Range | ±1999.9 mV |
| Temperature Range | −5 to 105°C |
| Temp Accuracy | ±0.1°C |
| Data Storage | 1000 sets with timestamp |
| GLP Compliance | Yes |
| Interface | Dual RS232 & optional USB |
| IP Rating | IP54 |