- All
- Favorite
- Popular
- Most rated
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nitrogen & Zero-Air Generator |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation |
| Nitrogen Output Flow | 25 L/min @ 99.9% purity |
| Zero-Air Output Flow | 2 × independently adjustable streams, total 20 L/min |
| Total Gas Output | 45 L/min (25 L/min N₂ + 20 L/min zero-air) |
| Output Pressure Range | 0–7 bar |
| Noise Level | <60 dB(A) |
| Startup Time | ≤5 min |
| Filtration Stages | 3-stage integrated purification (coalescing, hydrocarbon adsorption, sub-micron particulate) |
| Safety Features | Low-water-level alarm, overpressure cutoff, leak-triggered shutdown |
| Power Supply | 220 V AC, 50 Hz |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | UHAN1-1 |
| Gas Purity | 99.99996% (N₂), Zero Air (HC < 0.1 ppm, CO < 0.1 ppm, NOₓ < 0.1 ppm, SO₂ < 0.1 ppm, H₂O < 1 ppm) |
| Output Flow Rate | 1.2 L/min (combined or individually configurable) |
| Output Pressure Range | 0–7 bar (adjustable and pressure-stabilized) |
| Design | Integrated Monoblock Architecture |
| Control Interface | Intelligent Full-Color Touchscreen with Embedded IoT Module |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic |
| Model | AIRCOMP30 |
| Price | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 30 L/min |
| Output Pressure Range | 0–7 bar |
| Total Hydrocarbon Content | < 0.1 ppm |
| Dew Point | –20 °C |
| Compressor Type | Oil-Free Imported Scroll Compressor |
| Noise Level | ≤ 52 dB(A) |
| Power Supply | 220 V AC, 50 Hz |
| Dimensions (W×D×H) | 480 × 420 × 620 mm |
| Weight | 42 kg |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | ZeroAir35 |
| Quotation | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Oxidation |
| Output Flow Rate | 35 L/min |
| Output Pressure Range | 0–6 bar (adjustable) |
| Total Hydrocarbon Content (THC) | <0.1 ppm (as methane equivalent) |
| Residual THC after dual-stage purification | <0.05 ppm |
| Particulate Filtration | 0.01 µm absolute rating |
| Noise Level | ≤55 dB(A) |
| Continuous Operation Rating | 7×24 hours |
| Rated Service Life | >30,000 operating hours |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | i-Lab Technology Co., Ltd. |
| Model | N45-1Pro |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with dual-tower configuration and imported high-efficiency carbon molecular sieve (CMS) |
| Output Flow Rate | 45 L/min |
| Output Pressure Range | 0–8 bar |
| Nitrogen Purity | 99.9% |
| Noise Level | <60 dB(A) |
| CMS Surface Area | BET >800 m²/g |
| Tower Switching Accuracy | <0.1 s |
| Power Consumption Reduction (ECO Mode) | 15% |
| CMS Service Life | 5–8 years |
| Flow Stability Error | ≤±2% |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 0–160 L/min |
| Output Pressure | 0–7 bar |
| Nitrogen Purity | 99.9% |
| Design Architecture | Split-System (Requires External Air Compressor) |
| Control Interface | Touchscreen LCD with Real-Time Monitoring |
| Connectivity | IoT-Enabled Remote Monitoring & Management |
| Operational Duty Cycle | Continuous 24/7 Operation |
| Compliance Context | Designed for GLP/GMP-aligned laboratories |
| compatible with ASTM D857 and ISO 8573-1 | 2010 Class 2 compressed air input requirements |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | ZeroAir5 |
| Pricing | Available Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 5 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content (THC) | <0.1 ppm |
| Brand | Kailai i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | Smart Gas Management System |
| Pricing | Upon Request |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KL160-0 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation |
| Output Flow Rate | 160 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | ≥99.9% |
| Filtration Precision | 0.01 µm |
| Safety Features | Overpressure Alarm, Leak Detection with Auto-Shutdown |
| Power Supply | Standard 220 V AC, 50 Hz |
| Dimensions (L×W×H) | Compact Modular Footprint — Configurable for Integrated or Remote Installation |
| Compliance | Designed to Support GLP/GMP Environments |
| Compatible with ASTM D6349 and ISO 8573-1 Class 2 | 2:2 Air Quality Requirements for Instrument Gas |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | KL12-1 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation |
| Output Flow Rate | 12 L/min |
| Output Pressure | 0–6 bar |
| Nitrogen Purity | 99.9% |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Model | HG3000 |
| Hydrogen Generation Principle | SPE-PEM Solid Polymer Electrolyte Electrolysis |
| Output Flow Rate | 0–3000 mL/min |
| Output Pressure Options | 0–0.4 MPa / 0–0.7 MPa / 0–1.0 MPa / 0–1.5 MPa |
| Hydrogen Purity | ≥99.9995% (v/v) |
| Power Consumption | 1500 W |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | UHN1-1 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 1.2 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.999% |
| Noise Level | <45 dB(A) |
| Control Interface | Full-color TFT touchscreen |
| Connectivity | Embedded IoT module for remote monitoring and status reporting |
| Compliance | Designed to meet ISO 8573-1 Class 1 compressed air quality requirements for nitrogen supply to analytical instruments |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HG200 |
| Pricing | Upon Request |
| Hydrogen Generation Principle | SPE (Solid Polymer Electrolyte) / PEM (Proton Exchange Membrane) Pure-Water Electrolysis |
| Output Flow Rate | 0–200 mL/min |
| Output Pressure | 0–8 bar |
| Hydrogen Purity | 99.9995% |
| Power Consumption | 300 W |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | UHN5-1EL |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 5 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | ≥99.999% (O₂ < 3 ppm, Dew Point ≤ −60 °C) |
| Flow Stability | ±1% |
| Pressure Fluctuation | < 0.3% |
| Noise Level | < 60 dB(A) |
| Certifications | ISO 9001, CE |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | i-Lab |
| Type | Domestic |
| Model | ZeroAir1 |
| Price | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 1 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content (THC) | <0.1 ppm |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation + SFP Split Flow Purification |
| Output Flow Rate | 0–100 mL/min |
| Output Pressure | 0–4 bar |
| Nitrogen Purity | 99.999% |
| Oxygen Content | <3 ppm |
| Dew Point | ≤−60 °C |
| Flow Stability | ±0.5% |
| Noise Level | <45 dB(A) |
| Power Consumption | 100 W |
| Operating Environment | 5–35 °C, 5–80% RH |
| Interface | Modular External Gas Inlet (Air or 99.9% N₂) |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | i-Lab Technology Co., Ltd. |
| Model | N60-1Pro |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with dual-tower configuration and imported high-efficiency carbon molecular sieve (CMS) columns |
| Output Flow Rate | 60 L/min |
| Output Pressure Range | 0–8 bar |
| Nitrogen Purity | 99.9% (up to 99.95% under optimized conditions) |
| Noise Level | <60 dB(A) |
| CMS Surface Area | BET >800 m²/g |
| Tower Switching Accuracy | <0.1 s |
| Power Consumption Reduction (ECO Mode) | 15% |
| CMS Service Life | 5–8 years |
| Flow Stability Error | ≤±2% |
| Modular Design | Yes |
| IoT Connectivity | Yes |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| compatible with ASTM D6349, ISO 8573-1 Class 2 | 2:2 (for particle, water, oil), and FDA 21 CFR Part 11-ready data logging (via optional software module) |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | ZeroAir10 |
| Quotation | Upon Request |
| Hydrocarbon Removal Principle | Pt-Pd Catalytic Cracking |
| Output Flow Rate | 10 L/min |
| Output Pressure Range | 0–6 bar |
| Total Hydrocarbon Content | < 0.1 ppm (as methane equivalent) |
| Dew Point | –60 °C |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | UHAN2-1 |
| Gas Purity | 99.99996% (N₂) |
| Nitrogen Output Flow | 2 L/min |
| Output Pressure Range | 0–7 bar |
| Design | Integrated Monoblock Architecture |
| Control Interface | Intelligent Touchscreen HMI |
| Noise Level | <45 dB(A) |
| Core Technology | Imported PSA Molecular Sieve Modules + Oil-Free Compressor |
| Safety Features | Overpressure Protection, Automatic Pressure Relief |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | On-Site Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 0–240 L/min |
| Output Pressure | 0–7 bar(g) |
| Nitrogen Purity | 99.9% |
| Control Interface | Touchscreen LCD with Real-Time Monitoring |
| Remote Management | IoT-Enabled Cloud Connectivity |
| Structural Design | Split-System (Requires External Air Compressor) |
| Duty Cycle | Continuous 24/7 Operation |
| Compliance | Designed for GLP/GMP-Compliant Laboratories |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KL42-1 |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Imported High-Flow Hollow-Fiber Membrane Technology |
| Output Flow Rate | 19 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.9% |
| Gas Outputs | Nitrogen + Zero-Air (Dried & Hydrocarbon-Free) |
| Integrated Components | Built-in Oil-Free Air Compressor, Dual Buffer Tanks (N₂ & Air), Pressure Protection System, Intelligent Standby Control |
| Filtration Stages | Coalescing Pre-Filter, Desiccant Dryer, Hydrocarbon Adsorber, Particulate Final Filter |
| Noise Level | <55 dB(A) |
| Mobility | Heavy-Duty Swivel Casters with Locking Brakes |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | KL35-1A |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Hollow Fiber Membrane Separation |
| Nitrogen Output Flow Rate | 45 L/min (N₂: 10 L/min + Zero-Air: 35 L/min) |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.9% |
| Air Supply Configuration | Dual Zero-Air Streams |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Classification | Domestic (China) |
| Model | N2 Haloes |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) using Carbon Molecular Sieves |
| Output Flow Rate | Up to 50 L/min (typical configuration) |
| Purity | 99.5%–99.9995% (adjustable per application requirement) |
| Outlet Pressure | 0–7 bar (g) adjustable |
| Dew Point | ≤ –40 °C (standard), optional down to –70 °C |
| Power Supply | 220 V AC, 50/60 Hz |
| Ambient Operating Temperature | 5–35 °C |
| Noise Level | < 60 dB(A) |
| Compliance | CE-marked, ISO 8573-1 Class 2:2:2 (compressed air feed required), compatible with GLP/GMP environments |
| Brand | i-Lab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Nitrogen Generator |
| Nitrogen Generation Principle | Pressure Swing Adsorption (PSA) with Carbon Molecular Sieve (CMS) |
| Output Flow Rate | 75 L/min |
| Output Pressure Range | 0–7 bar |
| Nitrogen Purity | 99.9% |
| Integrated Buffer Tank Capacity | 25 L |
| Operating Mode | Continuous 24/7 Unattended Operation |
| Compliance | Designed for GLP/GMP-aligned laboratories |
| Interface | Touchscreen LCD with real-time pressure, flow, and status monitoring |
| Structural Design | Split-system (requires external air compressor) |
| Mobility | Heavy-duty swivel casters rated for high-pressure lab environments |
Show next