Add to compare
BrandSETARAM
OriginFrance
ModelThemy HP TGA
Temperature RangeRT to 1200 °C
Maximum Operating Pressure≤150 bar
Balance Sensitivity0.023 µg
Heating/Cooling Rate0.01–100 K/min
Mass Resolution≤0.03 µg
Sample Capacityup to 100 g
Mass Dynamic Range±2000 mg / ±200 mg
Vacuum Level<10⁻² mbar
Atmosphere CompatibilityO₂, H₂, CO, CO₂, CH₄, N₂, Ar, He, and reactive/corrosive gases
Cooling MethodIntegrated water cooling (cool-down time <20 min)
Temperature Accuracy±0.1 K
Baseline NoiseUltra-low, enabling high-fidelity kinetic analysis under pressure
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelTHEMYS DUO (formerly TAG)
Temperature RangeAmbient to 1750 °C
Temperature Accuracy±0.25 K
Balance Sensitivity0.002 µg
Heating/Cooling Rate0.01–100 K/min
Maximum Sample Mass35 g
Baseline Drift≤5 µg at 1750 °C
Simultaneous Sample CapacityMultiple
Atmosphere Control3-channel mass-flow-controlled carrier gas (4–200 mL/min) + 1 auxiliary/reactive gas channel (0.3–16 mL/min)
Crucible OptionsAl₂O₃, W, graphite, Pt, quartz, Al (55–1500 µL)
Sensor ConfigurationsTGA, DTA, and DSC rods (interchangeable)
Dimensions (H×W×D)170 × 60 × 55 cm
Weight145 kg
Power Supply230 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSetaram
OriginFrance
ModelTHEMYS HP
Temperature RangeAmbient to 1200 °C
Pressure RangeUp to 150 bar
Sample Capacity35 g
Balance Sensitivity0.0023 µg
Baseline Drift±200 µg
Heating/Cooling Rate0.01–100 K/min
Crucible Volume1300 µL
Gas Configuration3-channel mass flow controlled (2 MFCs standard with auxiliary gas option)
Vacuum Capability<1 mbar (primary), <5×10⁻² mbar (forced)
Safety ComplianceEU PED 2014/68/EU, Group 2 gases
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSetaram
OriginFrance
ModelLabsys Evo-TGA
Temperature RangeRT–1600 °C
Temperature Accuracy±0.1 K
Balance Sensitivity0.02 µg
Heating/Cooling Rate0.01–100 K/min
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelSetsys EVO
Temperature Range−150 °C to 1750 °C (upgradable to 2400 °C)
Heating Rate0–100 K/min (full range)
Max. TG Sample Capacity35 g / 100 g
TG Resolution0.002 µg / 0.02 µg
TG Baseline Repeatability<10 µg (RT to 1750 °C)
DSC Resolution1 µW
DTA Resolution0.4 µW
Gas Lines3 carrier + 1 auxiliary/reactive gas, controlled via MFCs and solenoid valves
Atmosphere Optionsinert, oxidative, reductive, steam, corrosive gases
Vacuum Systemup to 10⁻⁴ mbar (10⁻² torr)
EGA CompatibilityMS, FT-IR, GC
Optional ModulesWetsys humidity control, H₂-safe operation kit, corrosive gas kits (SO₂, NH₃, H₂S)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelSetsys Evolution
Temperature RangeRT to 2400 °C
Temperature Accuracy±0.1 K
Balance Sensitivity0.03–0.3 µg
Heating/Cooling Rate0–100 K/min
Atmosphere OptionsInert, Oxidizing, Reducing, Steam, Corrosive Gases
Vacuum CapabilityDown to 10⁻⁴ mbar
Modular CompatibilityDTA, DSC, TMA
Gas MixingDual purge + protective gas with mass flow control (50/50 to 1/99 ratio)
Humidity IntegrationOptional RH-controlled module
Evolved Gas Analysis (EGA)Heated capillary transfer up to 200 °C for FTIR/MS/GC-MS coupling
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginBeijing, China (Manufactured under France-China joint development)
ModelSetline TGA
Temperature RangeAmbient to 1100 °C
Temperature Accuracy±0.3 K
Temperature Precision±0.1 °C
Heating/Cooling Rate0.01–50 K/min
Dynamic Mass Range±20 mg / ±200 mg
Balance Sensitivity0.0023 µg
Mass Accuracy0.01%
Mass Precision0.005%
Maximum Sample Mass0.3 g
Baseline Drift25 µg
Baseline Repeatability±5 µg
Atmosphere OptionsInert (N₂, Ar, He) or Oxidizing (air, O₂)
Gas Flow Rate10–100 mL/min
Crucible MaterialsAl, Al₂O₃, Pt, Quartz (130–250 µL volume)
CoolingIntegrated water-cooled furnace
SoftwareCALISTO 2.0 Thermal Analysis Suite
Power Supply230 V, 50/60 Hz
Dimensions (H×W×D)650(850)×400×500 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelThemys
Temperature Range0–1750 °C (up to 2400 °C in optional configurations)
Temperature Accuracy±0.1 K
Balance Sensitivity0.00059 µg
Heating/Cooling Rate0.01–100 K/min
Maximum Sample Mass100 g
Baseline Drift±3 µg
Simultaneous Measurement CapabilityTGA, DTA, DSC, STA, TMA, EGA
Atmosphere OptionsInert, oxidizing, reducing, corrosive (e.g., H₂, NH₃, SO₂, H₂S), vacuum (primary <5×10⁻² mbar
Gas ControlUp to 3 independent mass flow controllers (MFCs), programmable gas switching, heated EGA interfaces (4×, up to 300 °C)
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelThemys Flash
Operating EnvironmentAmbient Pressure
Simultaneous Sample CapacityUp to 5
Instrument TypeUniversal TGA
Temperature RangeRoom Temperature to 1200 °C
Dynamic Weighing Range±20 mg, ±200 mg
Balance Sensitivity0.0023 µg
Heating/Cooling RateUp to 600 K/min
Maximum Sample Mass35 g
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelTHEMYS LV
Temperature RangeRoom Temp to 2000 °C (TGA/DTA/TG-DTA), up to 1600 °C (TG-DSC/DSC/TMA)
Sample CapacityUp to 100 g / 18.1 mL
Balance Sensitivity0.02 µg
Heating/Cooling Rate0.01–20 K/min
Maximum Crucible Volume18.1 mL
TMA Resolution1.6 nm
TMA Measurement Range±6 mm
Gas Control3-channel MFC-controlled gas lines (including optional corrosive gas path)
Vacuum CapabilityPrimary vacuum (< 5×10⁻² mbar), secondary vacuum optional
Balance Load Capacity±200 mg (low-load mode), ±2000 mg (high-load mode)
DSC/DTA Accuracy±2% (heat flow), ±1 °C (temperature, calibrated vs. metal standards)
Show next