- All
- Favorite
- Popular
- Most rated
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themy HP TGA |
| Temperature Range | RT to 1200 °C |
| Maximum Operating Pressure | ≤150 bar |
| Balance Sensitivity | 0.023 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Mass Resolution | ≤0.03 µg |
| Sample Capacity | up to 100 g |
| Mass Dynamic Range | ±2000 mg / ±200 mg |
| Vacuum Level | <10⁻² mbar |
| Atmosphere Compatibility | O₂, H₂, CO, CO₂, CH₄, N₂, Ar, He, and reactive/corrosive gases |
| Cooling Method | Integrated water cooling (cool-down time <20 min) |
| Temperature Accuracy | ±0.1 K |
| Baseline Noise | Ultra-low, enabling high-fidelity kinetic analysis under pressure |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS DUO (formerly TAG) |
| Temperature Range | Ambient to 1750 °C |
| Temperature Accuracy | ±0.25 K |
| Balance Sensitivity | 0.002 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 35 g |
| Baseline Drift | ≤5 µg at 1750 °C |
| Simultaneous Sample Capacity | Multiple |
| Atmosphere Control | 3-channel mass-flow-controlled carrier gas (4–200 mL/min) + 1 auxiliary/reactive gas channel (0.3–16 mL/min) |
| Crucible Options | Al₂O₃, W, graphite, Pt, quartz, Al (55–1500 µL) |
| Sensor Configurations | TGA, DTA, and DSC rods (interchangeable) |
| Dimensions (H×W×D) | 170 × 60 × 55 cm |
| Weight | 145 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | THEMYS HP |
| Temperature Range | Ambient to 1200 °C |
| Pressure Range | Up to 150 bar |
| Sample Capacity | 35 g |
| Balance Sensitivity | 0.0023 µg |
| Baseline Drift | ±200 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Crucible Volume | 1300 µL |
| Gas Configuration | 3-channel mass flow controlled (2 MFCs standard with auxiliary gas option) |
| Vacuum Capability | <1 mbar (primary), <5×10⁻² mbar (forced) |
| Safety Compliance | EU PED 2014/68/EU, Group 2 gases |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Labsys Evo-TGA |
| Temperature Range | RT–1600 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys EVO |
| Temperature Range | −150 °C to 1750 °C (upgradable to 2400 °C) |
| Heating Rate | 0–100 K/min (full range) |
| Max. TG Sample Capacity | 35 g / 100 g |
| TG Resolution | 0.002 µg / 0.02 µg |
| TG Baseline Repeatability | <10 µg (RT to 1750 °C) |
| DSC Resolution | 1 µW |
| DTA Resolution | 0.4 µW |
| Gas Lines | 3 carrier + 1 auxiliary/reactive gas, controlled via MFCs and solenoid valves |
| Atmosphere Options | inert, oxidative, reductive, steam, corrosive gases |
| Vacuum System | up to 10⁻⁴ mbar (10⁻² torr) |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Modules | Wetsys humidity control, H₂-safe operation kit, corrosive gas kits (SO₂, NH₃, H₂S) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evolution |
| Temperature Range | RT to 2400 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.03–0.3 µg |
| Heating/Cooling Rate | 0–100 K/min |
| Atmosphere Options | Inert, Oxidizing, Reducing, Steam, Corrosive Gases |
| Vacuum Capability | Down to 10⁻⁴ mbar |
| Modular Compatibility | DTA, DSC, TMA |
| Gas Mixing | Dual purge + protective gas with mass flow control (50/50 to 1/99 ratio) |
| Humidity Integration | Optional RH-controlled module |
| Evolved Gas Analysis (EGA) | Heated capillary transfer up to 200 °C for FTIR/MS/GC-MS coupling |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under France-China joint development) |
| Model | Setline TGA |
| Temperature Range | Ambient to 1100 °C |
| Temperature Accuracy | ±0.3 K |
| Temperature Precision | ±0.1 °C |
| Heating/Cooling Rate | 0.01–50 K/min |
| Dynamic Mass Range | ±20 mg / ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Mass Accuracy | 0.01% |
| Mass Precision | 0.005% |
| Maximum Sample Mass | 0.3 g |
| Baseline Drift | 25 µg |
| Baseline Repeatability | ±5 µg |
| Atmosphere Options | Inert (N₂, Ar, He) or Oxidizing (air, O₂) |
| Gas Flow Rate | 10–100 mL/min |
| Crucible Materials | Al, Al₂O₃, Pt, Quartz (130–250 µL volume) |
| Cooling | Integrated water-cooled furnace |
| Software | CALISTO 2.0 Thermal Analysis Suite |
| Power Supply | 230 V, 50/60 Hz |
| Dimensions (H×W×D) | 650(850)×400×500 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys |
| Temperature Range | 0–1750 °C (up to 2400 °C in optional configurations) |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.00059 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 100 g |
| Baseline Drift | ±3 µg |
| Simultaneous Measurement Capability | TGA, DTA, DSC, STA, TMA, EGA |
| Atmosphere Options | Inert, oxidizing, reducing, corrosive (e.g., H₂, NH₃, SO₂, H₂S), vacuum (primary <5×10⁻² mbar |
| Gas Control | Up to 3 independent mass flow controllers (MFCs), programmable gas switching, heated EGA interfaces (4×, up to 300 °C) |
| Compliance | Designed for GLP/GMP environments |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themys Flash |
| Operating Environment | Ambient Pressure |
| Simultaneous Sample Capacity | Up to 5 |
| Instrument Type | Universal TGA |
| Temperature Range | Room Temperature to 1200 °C |
| Dynamic Weighing Range | ±20 mg, ±200 mg |
| Balance Sensitivity | 0.0023 µg |
| Heating/Cooling Rate | Up to 600 K/min |
| Maximum Sample Mass | 35 g |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS LV |
| Temperature Range | Room Temp to 2000 °C (TGA/DTA/TG-DTA), up to 1600 °C (TG-DSC/DSC/TMA) |
| Sample Capacity | Up to 100 g / 18.1 mL |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–20 K/min |
| Maximum Crucible Volume | 18.1 mL |
| TMA Resolution | 1.6 nm |
| TMA Measurement Range | ±6 mm |
| Gas Control | 3-channel MFC-controlled gas lines (including optional corrosive gas path) |
| Vacuum Capability | Primary vacuum (< 5×10⁻² mbar), secondary vacuum optional |
| Balance Load Capacity | ±200 mg (low-load mode), ±2000 mg (high-load mode) |
| DSC/DTA Accuracy | ±2% (heat flow), ±1 °C (temperature, calibrated vs. metal standards) |
Show next