Empowering Scientific Discovery

Kapu Technology (Shanghai) Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelC600
Temperature RangeAmbient to 600 °C
Heating Rate0.01–2.000 °C/min
Calorimetric Resolution0.1 µW
Isothermal Stability (40 °C)±0.001 °C
Temperature Accuracy±0.1 °C
Calorimetric Accuracy±0.1%
Enthalpy Accuracy±1%
Reaction Cell Volume8.5–12.5 mL
RMS Noise1 µW
Sensitivity (Joule Effect at 30 °C)30 µW/mW
Dynamic Range±660 mW / ±2000 mW
Pressure CapabilityUp to 1000 bar (14,500 psi)
Sample FormSolid, Liquid, Powder, Thin Film, or Fiber
Dimensions (H×W×D)60×25×31 cm
Weight30 kg
Power Supply230 V, 50/60 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelMicrocalvet Ultra
Instrument TypeReaction Calorimeter
Measurement ModeIsothermal & Scanning Calorimetry
Temperature Range–20 °C to 170 °C
SensitivitySub-microwatt (µW) thermal power resolution
Sample EnvironmentCompatible with high-pressure (up to 400 bar), vacuum, gas-controlled, and stirred/mixed configurations
Interfacing CapabilityIntegrated coupling with BET surface analyzers, physicochemical adsorption systems, humidity generators, and high-pressure/vacuum gas controllers
Calibration MethodJoule calibration with 3D Calvet sensor architecture
Sample Cell OptionsInterchangeable, chemically resistant, easy-clean crucibles for solids, powders, gels, liquids, and slurries
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFauske
OriginUSA
Manufacturer TypeAuthorized Distributor
Product CategoryImported Instrument
ModelVSP2
Price RangeUSD 135,000 – 270,000 (based on configuration and service package)
Measurement ModeAdiabatic Calorimetry
Instrument TypeReaction Calorimeter
Sample Volume116 mL
Cell Wall Thickness0.01 in (0.254 mm)
Thermal Inertia (φ)≤ 1.05
Maximum Pressure Rating>2000 psi (13.8 MPa)
HeatingDual-zone (internal sample heater + external guard heater)
Pressure EqualizationActive dynamic compensation
StirringOptional magnetic stirring (standard & high-torque super-magnetic variants)
Cell Materials304 SS, 316 SS, Hastelloy C, Titanium, Quartz
Test ModesClosed, Venting (small-scale relief), Isothermal, Dynamic Ramp, Quench Simulation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelCalvet LV
Instrument TypeReaction Calorimeter
Measurement ModeIsothermal
Temperature RangeAmbient to 200 °C
Sample CapacityUp to 100 mL (e.g., two D-cell batteries)
Sensor Architecture2- or 4-channel 3D Calvet thermopile (up to 1,316 thermocouples per stack)
Pressure CapabilityUp to 350 bar
Vacuum CompatibilityHigh vacuum
Optional FunctionsIn-situ stirring, gas flow control, electrochemical cycling (battery charge/discharge), pressure regulation & monitoring
ComplianceDesigned for GLP/GMP-aligned workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelCalvet CRYO
Instrument TypeReaction Calorimeter
Measurement ModeHeat Flow (3D Calvet Principle)
Temperature Range–196 °C to 200 °C
Temperature Resolution0.1 μW (heat flow resolution)
Sample EnvironmentVacuum-jacketed, configurable for high pressure (up to 1000 bar), vacuum, inert gas, or reactive atmospheres
Sensor ArchitectureDual cylindrical thermopile arrays (480 thermocouples per array), fully surrounding sample and reference zones
ComplianceDesigned for GLP/GMP environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelCALVET HT
Temperature RangeRT to 600 °C
Temperature Precision±0.5 °C
Measurement Principle3D Symmetrical Heat-Flow Calorimetry
Maximum Operating Pressure400 bar
Sample ConfigurationCustomizable high-pressure, vacuum-compatible, stirred, or gas-flow-integrated cells
CoolingExternal recirculating water bath
ComplianceDesigned for GLP/GMP-aligned workflows and ASTM E698, ISO 11358, and UN Test Series 3 compatibility
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelMicrocalvet
Instrument TypeReaction Calorimeter
Measurement Principle3D Calorimetric Sensor with Joule Calibration
Temperature Range−45 °C to 120 °C
Accuracy±0.15%
Sample CapacityVariable (micro-to-milligram scale)
Pressure CapabilityUp to 1000 bar (with optional high-pressure cells)
CompatibilityVacuum, inert atmosphere, reactive gas environments
Thermal ControlPeltier-based 3-axis symmetric heating/cooling
InterfaceModular coupling with BET analyzers, gas sorption systems, humidity generators, and high-pressure gas controllers
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelCalvet HT (formerly C600)
Instrument TypeReaction Calorimeter
Measurement Mode3D Calvet Calorimetry
Temperature RangeAmbient to 600 °C
Temperature Resolution0.5 μW (heat flow resolution)
Pressure CapabilityUp to 400 bar
Sample ConfigurationDual-zone 3D thermopile sensor array
ComplianceDesigned for GLP/GMP environments, compatible with ASTM E698, ISO 11357-4, and USP <1031> thermal stability protocols
Added to wishlistRemoved from wishlist 0
Add to compare
BrandFauske
OriginUSA
Instrument TypeAdiabatic Reaction Calorimeter
Measurement ModeAdiabatic Calorimetry
ModelARSST
Compliance BasisDIERS-validated two-phase flow methodology (OSHA-recognized “Exemplary Engineering Practice”)
Sample Volume5–10 g in 10 mL lightweight quartz test cell
Pressure Vessel Capacity350 mL rated pressure vessel
Operating ModesScanning & Isothermal
Optional AccessoriesHigh-pressure test cells, Flow-Regime Evaluation Detector (FRED™)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelCALVET C80
Measurement Principle3D Heat-Flow Calorimetry (Calvet-type)
Temperature RangeAmbient to 300 °C
Temperature Precision±0.15 °C
Sample CapacityMicroscale (µg–mg range)
Operating ModesIsothermal & Temperature-Scanning
Pressure CapabilityUp to 1000 bar (with custom cells)
Vacuum CompatibilityYes
Gas/Liquid Flow IntegrationYes
ComplianceASTM E698, ISO 11357-4, USP <1031>, GLP/GMP-ready data audit trail (via C80 software)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSETARAM
OriginFrance
ModelCalvet Pro
Instrument TypeReaction Calorimeter
Measurement Principle3D Calvet-type Heat-Flow Calorimetry
Sample Mass Rangemg-scale
Temperature Range–120 °C to 830 °C
Pressure CapabilityUp to 500 bar (with optional high-pressure module)
Vacuum CompatibilityYes
Cp AccuracyHigh-precision absolute heat capacity measurement
Operating ModesIsothermal, Dynamic Scanning, and Stepwise Temperature Programs
Sensor ArchitectureSymmetric 3D thermopile array surrounding the sample and reference positions
Calibration MethodJoule-effect electrical calibration
Sample Environment ControlIntegrated pressure regulation, monitoring, and control