| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | C600 |
| Temperature Range | Ambient to 600 °C |
| Heating Rate | 0.01–2.000 °C/min |
| Calorimetric Resolution | 0.1 µW |
| Isothermal Stability (40 °C) | ±0.001 °C |
| Temperature Accuracy | ±0.1 °C |
| Calorimetric Accuracy | ±0.1% |
| Enthalpy Accuracy | ±1% |
| Reaction Cell Volume | 8.5–12.5 mL |
| RMS Noise | 1 µW |
| Sensitivity (Joule Effect at 30 °C) | 30 µW/mW |
| Dynamic Range | ±660 mW / ±2000 mW |
| Pressure Capability | Up to 1000 bar (14,500 psi) |
| Sample Form | Solid, Liquid, Powder, Thin Film, or Fiber |
| Dimensions (H×W×D) | 60×25×31 cm |
| Weight | 30 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Microcalvet Ultra |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal & Scanning Calorimetry |
| Temperature Range | –20 °C to 170 °C |
| Sensitivity | Sub-microwatt (µW) thermal power resolution |
| Sample Environment | Compatible with high-pressure (up to 400 bar), vacuum, gas-controlled, and stirred/mixed configurations |
| Interfacing Capability | Integrated coupling with BET surface analyzers, physicochemical adsorption systems, humidity generators, and high-pressure/vacuum gas controllers |
| Calibration Method | Joule calibration with 3D Calvet sensor architecture |
| Sample Cell Options | Interchangeable, chemically resistant, easy-clean crucibles for solids, powders, gels, liquids, and slurries |
| Compliance | Designed for GLP/GMP environments |
| Brand | Fauske |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | VSP2 |
| Price Range | USD 135,000 – 270,000 (based on configuration and service package) |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Sample Volume | 116 mL |
| Cell Wall Thickness | 0.01 in (0.254 mm) |
| Thermal Inertia (φ) | ≤ 1.05 |
| Maximum Pressure Rating | >2000 psi (13.8 MPa) |
| Heating | Dual-zone (internal sample heater + external guard heater) |
| Pressure Equalization | Active dynamic compensation |
| Stirring | Optional magnetic stirring (standard & high-torque super-magnetic variants) |
| Cell Materials | 304 SS, 316 SS, Hastelloy C, Titanium, Quartz |
| Test Modes | Closed, Venting (small-scale relief), Isothermal, Dynamic Ramp, Quench Simulation |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet LV |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal |
| Temperature Range | Ambient to 200 °C |
| Sample Capacity | Up to 100 mL (e.g., two D-cell batteries) |
| Sensor Architecture | 2- or 4-channel 3D Calvet thermopile (up to 1,316 thermocouples per stack) |
| Pressure Capability | Up to 350 bar |
| Vacuum Compatibility | High vacuum |
| Optional Functions | In-situ stirring, gas flow control, electrochemical cycling (battery charge/discharge), pressure regulation & monitoring |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet CRYO |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Heat Flow (3D Calvet Principle) |
| Temperature Range | –196 °C to 200 °C |
| Temperature Resolution | 0.1 μW (heat flow resolution) |
| Sample Environment | Vacuum-jacketed, configurable for high pressure (up to 1000 bar), vacuum, inert gas, or reactive atmospheres |
| Sensor Architecture | Dual cylindrical thermopile arrays (480 thermocouples per array), fully surrounding sample and reference zones |
| Compliance | Designed for GLP/GMP environments |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | CALVET HT |
| Temperature Range | RT to 600 °C |
| Temperature Precision | ±0.5 °C |
| Measurement Principle | 3D Symmetrical Heat-Flow Calorimetry |
| Maximum Operating Pressure | 400 bar |
| Sample Configuration | Customizable high-pressure, vacuum-compatible, stirred, or gas-flow-integrated cells |
| Cooling | External recirculating water bath |
| Compliance | Designed for GLP/GMP-aligned workflows and ASTM E698, ISO 11358, and UN Test Series 3 compatibility |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Microcalvet |
| Instrument Type | Reaction Calorimeter |
| Measurement Principle | 3D Calorimetric Sensor with Joule Calibration |
| Temperature Range | −45 °C to 120 °C |
| Accuracy | ±0.15% |
| Sample Capacity | Variable (micro-to-milligram scale) |
| Pressure Capability | Up to 1000 bar (with optional high-pressure cells) |
| Compatibility | Vacuum, inert atmosphere, reactive gas environments |
| Thermal Control | Peltier-based 3-axis symmetric heating/cooling |
| Interface | Modular coupling with BET analyzers, gas sorption systems, humidity generators, and high-pressure gas controllers |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet HT (formerly C600) |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | 3D Calvet Calorimetry |
| Temperature Range | Ambient to 600 °C |
| Temperature Resolution | 0.5 μW (heat flow resolution) |
| Pressure Capability | Up to 400 bar |
| Sample Configuration | Dual-zone 3D thermopile sensor array |
| Compliance | Designed for GLP/GMP environments, compatible with ASTM E698, ISO 11357-4, and USP <1031> thermal stability protocols |
| Brand | Fauske |
|---|---|
| Origin | USA |
| Instrument Type | Adiabatic Reaction Calorimeter |
| Measurement Mode | Adiabatic Calorimetry |
| Model | ARSST |
| Compliance Basis | DIERS-validated two-phase flow methodology (OSHA-recognized “Exemplary Engineering Practice”) |
| Sample Volume | 5–10 g in 10 mL lightweight quartz test cell |
| Pressure Vessel Capacity | 350 mL rated pressure vessel |
| Operating Modes | Scanning & Isothermal |
| Optional Accessories | High-pressure test cells, Flow-Regime Evaluation Detector (FRED™) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | CALVET C80 |
| Measurement Principle | 3D Heat-Flow Calorimetry (Calvet-type) |
| Temperature Range | Ambient to 300 °C |
| Temperature Precision | ±0.15 °C |
| Sample Capacity | Microscale (µg–mg range) |
| Operating Modes | Isothermal & Temperature-Scanning |
| Pressure Capability | Up to 1000 bar (with custom cells) |
| Vacuum Compatibility | Yes |
| Gas/Liquid Flow Integration | Yes |
| Compliance | ASTM E698, ISO 11357-4, USP <1031>, GLP/GMP-ready data audit trail (via C80 software) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Calvet Pro |
| Instrument Type | Reaction Calorimeter |
| Measurement Principle | 3D Calvet-type Heat-Flow Calorimetry |
| Sample Mass Range | mg-scale |
| Temperature Range | –120 °C to 830 °C |
| Pressure Capability | Up to 500 bar (with optional high-pressure module) |
| Vacuum Compatibility | Yes |
| Cp Accuracy | High-precision absolute heat capacity measurement |
| Operating Modes | Isothermal, Dynamic Scanning, and Stepwise Temperature Programs |
| Sensor Architecture | Symmetric 3D thermopile array surrounding the sample and reference positions |
| Calibration Method | Joule-effect electrical calibration |
| Sample Environment Control | Integrated pressure regulation, monitoring, and control |