| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo-DSC |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–100 K/min |
| Balance Max Capacity | 20 g |
| Balance Range | ±1000 mg |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Measurement Uncertainty | <2% |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic, Vacuum |
| Gas Control | 3 Mass-Flow-Controlled Carrier Gases + 1 Auxiliary/Reaction Gas |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 25-position ASC |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under French R&D supervision) |
| Model | Setline DSC+ |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Heat Flow Resolution | 0.1 µW |
| Heat Flow Range | ±6000 mW |
| Calorimetric Accuracy | ±0.8% (vs. standard metals) |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual independent gas flow channels with software-programmed auto-switching |
| Sensor Type | Flat-plate NiCr–Constantan thermopile |
| Cooling Options | Manual/automated LN₂ (−170 °C to 400 °C), He gas cryo-cooling (−70 °C to 200 °C), dry air/N₂/Ar (−50 °C to 400 °C) |
| Crucible Options | Al₂O₃, Al (30 & 100 µL), Incoloy high-pressure (30 µL, up to 500 bar at 600 °C), 316L stainless steel (optional) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line High-Temperature Specific Heat Analyzer |
| Temperature Range | Ambient to 2000 °C |
| Temperature Accuracy | ±0.5 °C (typical for high-temperature DSC-grade calibration) |
| Heating/Cooling Rate | 0.001–99 K/min |
| Sample Capacity (Calorimetry) | 5.7 mL (Ø14.5 mm × H35 mm) |
| Specific Heat Measurement Uncertainty | ≤1% (per ASTM E1269 & ISO 11357-4) |
| TGA Max Load | 100 g |
| TGA Resolution | 0.3 µg |
| TMA Range | ±6 mm |
| TMA Resolution | 1.6 nm |
| Modular Configurations | Simultaneous TG-DSC, TG-DTA, TMA, 3D Heat-Flow Calorimetry |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Operating Modes | Isothermal & Scanning |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.001–2 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Cell Materials | Stainless Steel or Hastelloy C |
| Maximum Pressure Rating | 1000 bar |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Manometric, Safety Cells |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Alexsys 800 / Alexsys 1000 |
| Calorimetry Principle | Isothermal Heat-Flow Calvet |
| Temperature Range | 500–800 °C (Alexsys 800) / 800–1000 °C (Alexsys 1000) |
| Sample Crucible Count | 2 |
| Crucible Volume | 28 mL / 20 mL (dual configuration) |
| Temperature Accuracy | ±0.1% of reading |
| Calorimetric Accuracy | ±1% |
| Heat Flow Resolution | 12.5 µW |
| Dimensions (W × H) | 800 mm × 880 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Sensys DSC High-Pressure Calvet Microcalorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Pressure | 500 bar at 600 °C |
| Pressure Monitoring Limit | 400 bar at 600 °C |
| DSC Sample Volume | up to 320 μL |
| DSC Detection Limit | 5 μW |
| DSC Resolution | 0.4 μW |
| TGA Max Sample Mass | 35 g |
| TGA Resolution | 0.03 μg |
| Gas Lines | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Auto-sampler Capacity | 48 positions |
| Software | Calisto v5.x with Cp measurement module |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | BT2.15 |
| Temperature Range | –196 to +200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–1 K/min |
| Detection Principle | 3D Calvet-type Heat Flow Calorimetry |
| Operating Modes | Isothermal & Non-Isothermal |
| Sample Environment | Open or Controlled-Atmosphere (including pressurized & mixing cells) |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Pressure Rating | Up to 1000 bar |
| Sensor Type | 3D Calvet Thermopile Array |
| Sample Cell Materials | Stainless Steel, Hastelloy C, or Custom Alloys |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Pressure-Monitoring, and Safety Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | –120 to 830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Mass Range | 3000 mg |
| Vacuum Level | <10⁻¹ mbar |
| TG Resolution | 0.002 µg |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static/Dynamic, Vacuum, Corrosive (e.g., H₂S, NH₃), Humidified Steam |
| Gas Control | Integrated 3-channel mass flow controller (2 carrier + 1 reactive gas), programmable mixing ratio (1:99 to 50:50) |
| TG Baseline Drift | <10 µg over full scan |
| TG Baseline Repeatability | ±1 µg |
| Evolved Gas Analysis Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 48-position ASC |
| Thermal Stability | ±0.001 to ±0.00001 °C (isothermal) |
| Sample Chamber Volume | 320 µL |
| Sensor Architecture | Calvet-type 3D thermopile sensor |
| Software | Calisto v6.x (21 CFR Part 11 compliant, GLP/GMP audit trail enabled) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C (LN₂ mode) / −80 to 500 °C (mechanical cooling) |
| Heating/Cooling Rate | 0–100 K/min |
| Dynamic Heat Flow Range | ±6000 mW |
| Gas Channels | 2 independent, software-controlled carrier gas lines |
| Pressure Rating | up to 500 bar with high-pressure crucibles |
| Sensor Type | removable heat-flux DSC sensor |
| Standard Software | CALISTO v5.x |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evolution |
| Temperature Range | -120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Sample Cell Pressure | 500 bar (at 600 °C) |
| Pressure Monitoring Range | Up to 400 bar (at 600 °C) |
| DSC Detection Limit | 5 µW |
| DSC Resolution | 0.4 µW |
| Sample Volume Capacity | 250 µL (up to 320 µL with extended cell) |
| TG Compatibility | Yes (up to 35 g sample, 0.03 µg resolution) |
| Atmosphere Options | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam, mixed gases (1–99% ratio) |
| Autosampler | 48-position |
| Software | Calisto v5.x (GLP-compliant, audit trail enabled) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | MICRO DSC7 |
| Temperature Range | −45 °C to 120 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Sample Cell Volume | 450 µL (intermittent mode) |
| Baseline Noise (RMS) | 0.4 µW |
| Minimum Detectable Heat Flow | 0.002 µW |
| Maximum Controllable Pressure | 1000 bar |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 Microcalorimeter |
| Temperature Range | Ambient to 300 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–2 K/min |
| Calorimetric Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Maximum Pressure Rating | 1000 bar |
| Sensor Principle | Calvet-type 3D-sensor |
| Thermal Enthalpy Accuracy | ±1% |
| Calorimetric Accuracy | ±0.1% |
| Temperature Precision | ±0.05 °C |
| Sample Cell Materials | Stainless Steel or Hastelloy C |
| Operating Modes | Isothermal and Scanning |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | uSC |
| Temperature Range | -40 °C to 200 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.001–1.2 K/min |
| Calorimetric Channels | 4 (2 sample + 2 reference) |
| Sample Cell Volume | 850 µL |
| Baseline Noise | 0.2 µW RMS |
| Sensitivity (Joule effect at 30 °C) | 100 µV/mW |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% RMS |
| DSC Resolution | 0.02 µW / 0.002 µW |
| Pressure Range (measurable & controllable) | 400 bar (5800 psi) |
| Brand | Setaram |
|---|---|
| Origin | Beijing, China (jointly developed by Chinese, French & Swiss teams) |
| Model | Setline DSC |
| Temperature Range | −170 to 700 °C |
| Programmable Heating/Cooling Rate | 0.01–100 °C/min |
| Temperature Accuracy | ±0.1 °C (vs. standard metals) |
| Temperature Precision | ±0.05 °C |
| DSC Signal Range | ±6000 mW |
| Heat Flow Resolution | 0.1 µW |
| Temperature Stability | ±0.1 °C (standard metal) |
| Sample Capacity | Single-position |
| Cooling Options | Manual/auto liquid nitrogen (−170 to 400 °C), He/Ar/dry air gas-cooling (−70 to 400 °C) |
| Gas Control | Dual-channel programmable gas switching |
| Software | Calisto 2.0 (data acquisition & processing with audit trail, user permissions, macro automation, Cp calculation) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | DSC131 Evo |
| Temperature Range | −170 to 700 °C |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±2% |
| Heat Flow Precision | ±0.5% |
| Noise Level (at 200 °C) | 1.5 μW |
| Sensitivity (Indium Fusion) | 3 μV/mW |
| Dynamic Heat Flow Range | ±6000 mW |
| Time Constant | 3 s |
| Gas Control | Dual-gas switching capability |
| Pressure Rating (uncontrolled) | up to 500 bar (7255 psi) at 600 °C |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (assembled with French-imported core components) |
| Model | Setline-dsc |
| Temperature Range | –170 to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified metal standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | DRC |
| Type | Laboratory-scale differential reaction calorimeter with dual-jacketed vessels, isothermal operation mode, and real-time ΔT monitoring via platinum resistance thermometers |
| Measurement Principle | Differential temperature-based heat flow quantification using Joule-effect calibration |
| Key Outputs | Reaction enthalpy (ΔHᵣₓₙ), mixing enthalpy (ΔHₘᵢₓ), adiabatic temperature rise (ΔTₐd), time-to-maximum-rate (tₘₐₓ), heat capacity (Cₚ), kinetic profiling |
| Compliance | Designed for GLP-compliant thermal safety assessment per ISO 11358, ASTM E698, and ICH Q1A(R2) guidelines |
| Software | CALISTO™ v5.0 with 21 CFR Part 11–compliant audit trail, raw data export (CSV, ASCII), and customizable reporting templates |
| Sample Compatibility | Liquid–liquid, liquid–gas, and heterogeneous slurries (max. working volume: 500 mL per vessel) |
| Temperature Control | Dual-circulating bath integration (±0.02 °C stability) |
| Sensor Resolution | ±0.001 °C ΔT detection limit |