| Key | Origin: France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | HT1000 |
| Pricing | Available Upon Request |
| Temperature Range | Ambient to 1000 °C |
| Sample Crucible Volume | 8.5 mL |
| Heat Flow Resolution | 4 µW |
| Baseline Noise | 8 µW |
| Crucible Types | Standard Crucible, Solid Specific Heat Crucible, Joule Calibration Crucible |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Flexi Hyco |
| Hydrogen Generation Principle | Water Electrolysis |
| Output Flow Rate | Up to 0.8 N·L/min or up to 1.6* N·L/min |
| Output Pressure | 10–200 bar (145–2900 psi) |
| Hydrogen Purity | 6.0–7.0 (v/v, ppm impurities) |
| Power Consumption | ~100 W |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Themy HP TGA |
| Temperature Range | RT to 1200 °C |
| Maximum Operating Pressure | ≤150 bar |
| Balance Sensitivity | 0.023 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Mass Resolution | ≤0.03 µg |
| Sample Capacity | up to 100 g |
| Mass Dynamic Range | ±2000 mg / ±200 mg |
| Vacuum Level | <10⁻² mbar |
| Atmosphere Compatibility | O₂, H₂, CO, CO₂, CH₄, N₂, Ar, He, and reactive/corrosive gases |
| Cooling Method | Integrated water cooling (cool-down time <20 min) |
| Temperature Accuracy | ±0.1 K |
| Baseline Noise | Ultra-low, enabling high-fidelity kinetic analysis under pressure |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | C600 |
| Temperature Range | Ambient to 600 °C |
| Heating Rate | 0.01–2.000 °C/min |
| Calorimetric Resolution | 0.1 µW |
| Isothermal Stability (40 °C) | ±0.001 °C |
| Temperature Accuracy | ±0.1 °C |
| Calorimetric Accuracy | ±0.1% |
| Enthalpy Accuracy | ±1% |
| Reaction Cell Volume | 8.5–12.5 mL |
| RMS Noise | 1 µW |
| Sensitivity (Joule Effect at 30 °C) | 30 µW/mW |
| Dynamic Range | ±660 mW / ±2000 mW |
| Pressure Capability | Up to 1000 bar (14,500 psi) |
| Sample Form | Solid, Liquid, Powder, Thin Film, or Fiber |
| Dimensions (H×W×D) | 60×25×31 cm |
| Weight | 30 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys-evo |
| Instrument Type | High-Pressure Chemisorption Calorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Repeatability | ±0.1% |
| Programmable Scan Rate | 0.01–30 °C/min |
| Heat Flow Resolution | 0.4 μW |
| Detection Limit | 5 μW |
| Maximum Sample Cell Pressure | 500 bar at 600 °C |
| Controlled/Measured Pressure Range | up to 400 bar at 600 °C |
| Sample Chamber Volume | 250 μL |
| Gas Channels | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Automated Sampler Capacity | 48 positions |
| Optional Coupling | TGA (35 g max, 0.03 μg resolution), FT-IR, MS, GC, humidity controller |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS DUO (formerly TAG) |
| Temperature Range | Ambient to 1750 °C |
| Temperature Accuracy | ±0.25 K |
| Balance Sensitivity | 0.002 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Maximum Sample Mass | 35 g |
| Baseline Drift | ≤5 µg at 1750 °C |
| Simultaneous Sample Capacity | Multiple |
| Atmosphere Control | 3-channel mass-flow-controlled carrier gas (4–200 mL/min) + 1 auxiliary/reactive gas channel (0.3–16 mL/min) |
| Crucible Options | Al₂O₃, W, graphite, Pt, quartz, Al (55–1500 µL) |
| Sensor Configurations | TGA, DTA, and DSC rods (interchangeable) |
| Dimensions (H×W×D) | 170 × 60 × 55 cm |
| Weight | 145 kg |
| Power Supply | 230 V, 50/60 Hz |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | GASPRO |
| Measurement Principle | Sievert-type Volumetric Method |
| Temperature Range | –260 °C to 500 °C (customizable beyond) |
| Pressure Range | Vacuum to 200 bar |
| Ultimate Vacuum | Two-stage vacuum system |
| Pressure Sensing | Dual-sensor architecture — high-pressure sensor (vacuum–200 bar, < 0.025 % FS accuracy), low-pressure sensor (vacuum–15 bar, < 0.12 % RD accuracy) |
| Minimum Detectable Uptake | 3 μmol (with Microdoser option) |
| Sample Mass Capability | Down to < 100 mg (patented US8132476 Microdoser) |
| Calibration Volumes | 5 pre-calibrated buffer volumes (5 mL to 1.2 L) |
| Gas Compatibility | CO₂, CH₄, N₂, Ar, H₂, He, and other non-corrosive gases |
| Safety Systems | Combustible gas detection, emergency pressure relief port |
| Control Modes | Isothermal PCT, adsorption/desorption kinetics, cyclic stability testing |
| Software Compliance | Audit-trail enabled, 21 CFR Part 11 ready (optional), GLP/GMP-supporting data integrity framework |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Labsys Evo-DSC |
| Temperature Range | Ambient to 1600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–100 K/min |
| Balance Max Capacity | 20 g |
| Balance Range | ±1000 mg |
| Balance Resolution | 0.02 µg |
| DSC Sensitivity | 0.4 µW (sensor-dependent) |
| Cp Measurement Uncertainty | <2% |
| Atmosphere Options | Inert, Oxidizing, Reducing, Static, Dynamic, Vacuum |
| Gas Control | 3 Mass-Flow-Controlled Carrier Gases + 1 Auxiliary/Reaction Gas |
| EGA Compatibility | MS, FT-IR, GC |
| Optional Autosampler | 25-position ASC |
| Brand | SETARAM |
|---|---|
| Origin | Beijing, China (Manufactured under French R&D supervision) |
| Model | Setline DSC+ |
| Temperature Range | −170 °C to 700 °C |
| Temperature Accuracy | ±0.1 °C (vs. certified standards) |
| Heating/Cooling Rate | 0.01–100 K/min |
| Heat Flow Resolution | 0.1 µW |
| Heat Flow Range | ±6000 mW |
| Calorimetric Accuracy | ±0.8% (vs. standard metals) |
| Calorimetric Precision | ±0.1% |
| Atmosphere Control | Dual independent gas flow channels with software-programmed auto-switching |
| Sensor Type | Flat-plate NiCr–Constantan thermopile |
| Cooling Options | Manual/automated LN₂ (−170 °C to 400 °C), He gas cryo-cooling (−70 °C to 200 °C), dry air/N₂/Ar (−50 °C to 400 °C) |
| Crucible Options | Al₂O₃, Al (30 & 100 µL), Incoloy high-pressure (30 µL, up to 500 bar at 600 °C), 316L stainless steel (optional) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | 96line High-Temperature Specific Heat Analyzer |
| Temperature Range | Ambient to 2000 °C |
| Temperature Accuracy | ±0.5 °C (typical for high-temperature DSC-grade calibration) |
| Heating/Cooling Rate | 0.001–99 K/min |
| Sample Capacity (Calorimetry) | 5.7 mL (Ø14.5 mm × H35 mm) |
| Specific Heat Measurement Uncertainty | ≤1% (per ASTM E1269 & ISO 11357-4) |
| TGA Max Load | 100 g |
| TGA Resolution | 0.3 µg |
| TMA Range | ±6 mm |
| TMA Resolution | 1.6 nm |
| Modular Configurations | Simultaneous TG-DSC, TG-DTA, TMA, 3D Heat-Flow Calorimetry |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | THEMYS HP |
| Temperature Range | Ambient to 1200 °C |
| Pressure Range | Up to 150 bar |
| Sample Capacity | 35 g |
| Balance Sensitivity | 0.0023 µg |
| Baseline Drift | ±200 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Crucible Volume | 1300 µL |
| Gas Configuration | 3-channel mass flow controlled (2 MFCs standard with auxiliary gas option) |
| Vacuum Capability | <1 mbar (primary), <5×10⁻² mbar (forced) |
| Safety Compliance | EU PED 2014/68/EU, Group 2 gases |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Setsys Evo TMA |
| Temperature Range | −150 °C to 2400 °C |
| Heating/Cooling Rate | 0–100 °C/min |
| Displacement Resolution | 0.2 nm |
| Displacement Noise | 5 nm |
| Force Range | 0–3.5 N (controllable) |
| Sample Length | 0–20 mm |
| Sample Diameter | ≤10 mm |
| Maximum Displacement Range | ±2 mm |
| Load Capacity | −150 g to +350 g |
| Measurement Modes | Compression, Penetration, 3-Point Bending, Tensile, Dilatometric, Volumetric Expansion |
| Origin | France |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MS80 |
| Pricing | Upon Request |
| Temperature Range | Ambient to 200 °C |
| Sample Cell Volume | 12.5 mL |
| Heat Flow Resolution | 0.08 µW |
| Baseline Noise | 0.1 µW |
| Configurations | 2-cell or 4-cell dual-isothermal design |
| Compatible Cell Types | Standard, Vacuum, Gas-Circulation, Liquid Heat Capacity, Solid Heat Capacity, Joule Calibration, and Mixing Cells |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Sensys Evo TG-DSC |
| Temperature Range | –120 to 830 °C |
| Heating/Cooling Rate | 0.01–30 °C/min |
| Temperature Stability | ±0.02 °C |
| Max Sample Mass | 3 g |
| Pressure Range (HP-DSC) | up to 500 bar (controlled up to 400 bar) |
| Atmosphere Compatibility | inert, oxidizing, reducing, corrosive (e.g., H₂S, NH₃), humidified, vacuum, steam |
| Balance Resolution | 0.002 µg |
| DSC Sensitivity | < 0.035 µW |
| TG Baseline Drift | < 10 µg (full-scale scan) |
| TG Baseline Repeatability | ±1 µg |
| Gas Control | integrated mass flow controllers, 3 carrier + 1 reactive gas channels |
| Sample Holder Options | TG-DSC and TG-DTA dual-mode crucibles |
| Optional Features | ASC auto-sampler (48 positions), humidity control module, FT-IR/MS/GC coupling interfaces |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | Labsys Evo-TGA |
| Temperature Range | RT–1600 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 0.02 µg |
| Heating/Cooling Rate | 0.01–100 K/min |
| Brand | Setaram |
|---|---|
| Origin | France |
| Model | C80 |
| Operating Modes | Isothermal & Scanning |
| Temperature Range | Ambient to 300 °C |
| Heating Rate | 0.001–2 °C/min |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.05 °C |
| Enthalpy Accuracy | ±1% |
| Calorimetric Precision | ±0.1% |
| Heat Flow Resolution | 0.10 µW |
| Maximum Sample Volume | 12.5 mL |
| Cell Materials | Stainless Steel or Hastelloy C |
| Maximum Pressure Rating | 1000 bar |
| Cell Types | Ampoule, Flip-Mix, Membrane-Mix, Fluid Circulation, Liquid Heat Capacity, Vacuum, Adsorption, High-Pressure Manometric, Safety Cells |
| Brand | SETARAM |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China (Manufactured in Taiwan) |
| Model | SCF Series |
| Temperature Range | +5 °C to +35 °C |
| Temperature Stability | ±0.1 °C |
| Cooling Capacity (at 20 °C) | 934–5740 W |
| Flow Rate | 14 L/min @ 3.5 kg/cm² (optional: 20 L/min @ 5.5 kg/cm²) |
| Reservoir Volume | 3.8 L |
| Dimensions (Reservoir) | 10 × 20 × 19 cm (W×D×H) |
| Overall Dimensions (SCF-25 to SCF-100) | 33×49×60 cm to 54×62×71 cm |
| Power Supply | 110/220 V, 50/60 Hz, 4–10 A |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Alexsys 800 / Alexsys 1000 |
| Calorimetry Principle | Isothermal Heat-Flow Calvet |
| Temperature Range | 500–800 °C (Alexsys 800) / 800–1000 °C (Alexsys 1000) |
| Sample Crucible Count | 2 |
| Crucible Volume | 28 mL / 20 mL (dual configuration) |
| Temperature Accuracy | ±0.1% of reading |
| Calorimetric Accuracy | ±1% |
| Heat Flow Resolution | 12.5 µW |
| Dimensions (W × H) | 800 mm × 880 mm |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Microcalvet Ultra |
| Instrument Type | Reaction Calorimeter |
| Measurement Mode | Isothermal & Scanning Calorimetry |
| Temperature Range | –20 °C to 170 °C |
| Sensitivity | Sub-microwatt (µW) thermal power resolution |
| Sample Environment | Compatible with high-pressure (up to 400 bar), vacuum, gas-controlled, and stirred/mixed configurations |
| Interfacing Capability | Integrated coupling with BET surface analyzers, physicochemical adsorption systems, humidity generators, and high-pressure/vacuum gas controllers |
| Calibration Method | Joule calibration with 3D Calvet sensor architecture |
| Sample Cell Options | Interchangeable, chemically resistant, easy-clean crucibles for solids, powders, gels, liquids, and slurries |
| Compliance | Designed for GLP/GMP environments |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | THEMYS H2 |
| Temperature Range | Ambient to 1000/1600/1750 °C |
| Heating Rate | 0.01–100 °C/min |
| Max Sample Mass | 35 g |
| Atmosphere | 3 Gas Lines (including dedicated H₂ line) |
| Safety | Dual H₂/O₂ Sensors, Interlocked Furnace & Balance, Emergency H₂ Shutoff, Vacuum- and High-Temp-Interlocked Access |
| Vacuum Level | < 5×10⁻² mbar |
| Resolution | 0.4 μW (DTA), 1 μW (DSC), 0.002 μg (TGA), 0.02 μg (microbalance), 0.2 nm (TMA) |
| Quantitative Accuracy | ±1.4% (DTA), ±0.9% (DSC), ±0.06% (TGA), ±0.08×10⁻⁶/°C (TMA expansion) |
| Brand | SETARAM |
|---|---|
| Model | Setline STA / Setline STA+ |
| Temperature Range | Ambient to 1100 °C |
| Heating Rate | 0.01–50 °C/min |
| Temperature Stability | ±0.05 °C |
| Max Sample Mass | 20 g |
| Atmosphere Options | Air, O₂, Inert (N₂, Ar) |
| Balance Resolution | 0.02 µg |
| TG Dynamic Range | ±200 mg / ±1000 mg |
| DSC Sensitivity | 1 µW |
| DSC Enthalpy Accuracy | ±1% |
| Optional Autosampler | 49-position |
| Cooling Method | Water-cooled furnace liner |
| Software | Calisto 2.0 (Data Acquisition & Processing) |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Sensys DSC High-Pressure Calvet Microcalorimeter |
| Temperature Range | −120 to +830 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.01–30 K/min |
| Maximum Pressure | 500 bar at 600 °C |
| Pressure Monitoring Limit | 400 bar at 600 °C |
| DSC Sample Volume | up to 320 μL |
| DSC Detection Limit | 5 μW |
| DSC Resolution | 0.4 μW |
| TGA Max Sample Mass | 35 g |
| TGA Resolution | 0.03 μg |
| Gas Lines | 3 carrier + 1 reactive/auxiliary |
| Atmosphere Compatibility | Oxidizing, reducing (H₂, CO), corrosive (H₂S, NH₃), steam |
| Auto-sampler Capacity | 48 positions |
| Software | Calisto v5.x with Cp measurement module |
| Brand | Fauske |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | VSP2 |
| Price Range | USD 135,000 – 270,000 (based on configuration and service package) |
| Measurement Mode | Adiabatic Calorimetry |
| Instrument Type | Reaction Calorimeter |
| Sample Volume | 116 mL |
| Cell Wall Thickness | 0.01 in (0.254 mm) |
| Thermal Inertia (φ) | ≤ 1.05 |
| Maximum Pressure Rating | >2000 psi (13.8 MPa) |
| Heating | Dual-zone (internal sample heater + external guard heater) |
| Pressure Equalization | Active dynamic compensation |
| Stirring | Optional magnetic stirring (standard & high-torque super-magnetic variants) |
| Cell Materials | 304 SS, 316 SS, Hastelloy C, Titanium, Quartz |
| Test Modes | Closed, Venting (small-scale relief), Isothermal, Dynamic Ramp, Quench Simulation |
| Brand | SETARAM |
|---|---|
| Origin | France |
| Model | Flexi WET200 |
| Instrument Type | Humidity Generator |
| Temperature Range | Ambient to 70 °C |
| Relative Humidity Range | 5–95% RH |
| Gas Flow Rate | 20–50 mL/min |
| Humidity Stability | ±0.3% RH |
| Compatible Gases | He, Air, Ar, N₂, CO₂ |
| Heating Stem Temperature | Ambient to 85 °C |
| Control System | Eurotherm-based PID loop with integrated RH, T, and flow feedback |