Empowering Scientific Discovery

Kemco Electronics (Shanghai) Trading Co., Ltd. – Kyoto Electronics Manufacturing Co., Ltd. (KEM)

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoto Electronics Manufacturing (KEM)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelHF-48
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryImported Instrument
ModelWPA-1000
Measurement ParametersTotal Phosphorus (TP) and Total Nitrogen (TN)
Instrument TypeOnline Continuous Analyzer
Measurement PrincipleSpectrophotometry (Molybdate Blue for TP
Measurement RangeTP: 0–0.5 mg P/L or 0–1 mg P/L (standard)
TN0–2 mg N/L or 0–5 mg N/L (standard)
Accuracy±2% of full scale (FS)
Detection Limit0.01 mg/L
Resolution0.001 mg/L
Optional Dilution Ratio2× to 500×
Sample Inlet CapacityUp to 3 independent sample streams via automated selector valve
Waste SeparationIntegrated dual-waste channel system
Reagent DeliveryPositive-displacement peristaltic pumping with quick-change cartridge design
Onboard CalculationReal-time pollutant load estimation (kg/day) based on flow rate integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelHL-36NS
PricingUpon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKyoto Electronics Manufacturing (KEM)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelHL-48
PricingAvailable upon Request
Added to wishlistRemoved from wishlist 0
Add to compare
BrandKEM (Kyoto Electronics Manufacturing)
OriginJapan
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product OriginImported
ModelHG-37N
Price RangeUSD 68,000 – 136,000 (FOB Japan)
Measurement PrincipleCold Vapor Atomic Absorption Spectroscopy (CVAAS) with Dry Oxidation-Reduction Conversion
Measurement Range0–50 µg/m³N or 0–1000 µg/m³N (switchable)
Response Time≤90 s
Repeatability±1% of reading
Linearity Error±2% of full scale
Zero Drift≤±1% per week
Sample Gas Flow Rate300 mL/min
Calibration IntervalRecommended every 30 days
Interference ResistanceImmune to Cl⁻, SO₂, NOₓ, H₂O vapor, and particulate carryover under ISO 15202-compliant sampling conditions
ComplianceDesigned to meet EPA Method 29, ASTM D6784-22, and EN 14181 QAL1 requirements for mercury CEMS