| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DA-100 |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±0.001 g/cm³ |
| Temperature Control Range | 15–40 °C (±0.1 °C stability, ±0.5 °C accuracy) |
| Repeatability | 0.001 g/cm³ |
| Resolution | 0.001 g/cm³ |
| Minimum Sample Volume | ~1 mL |
| Display | LCD |
| Measurement Time | 20–90 s |
| Calibration Standards | Dry air and double-distilled water |
| Data Interface | RS-232C |
| Power Supply | AC 100–240 V, 50/60 Hz, 30 W |
| Dimensions | 275 × 350 × 165 mm (W×D×H) |
| Weight | ~6 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Densitometer |
| Measurement Principle | U-Tube Oscillation Method |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±1×10⁻⁴ g/cm³ |
| Density Resolution & Repeatability | 0.0001 g/cm³ / SD ≤5×10⁻⁵ g/cm³ |
| Temperature Control Range | 0–96 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.05 °C |
| Temperature Resolution | 0.01 °C |
| Minimum Sample Volume | 1–2 mL |
| Auto-Sampling | Integrated peristaltic pump with rinse/dry cycle |
| Compliance | ASTM D4052, ISO 12185, BS EN ISO 15212-1, GB/T 2013, GB 5009.2, JJG 1058, GLP-ready data audit trail |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHD-502N |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory System |
| Sample Phase | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 1 × 10⁻⁶ g/cm³ |
| Density Repeatability | ±1 × 10⁻⁶ g/cm³ |
| Temperature Control Range | 0–96 °C |
| Minimum Sample Volume | 1–2 mL |
| Sample Capacity | 30 vials (20 mL glass bottles) |
| Integrated Vacuum/Pressure Pump | Yes, rated for up to 50,000 mPa·s viscosity |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions (W×D×H) | 582 × 445 × 392 mm |
| Weight | 17 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | DCU-551N |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Phase | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0–96 °C |
| Repeatability | ±1 × 10⁻⁶ g/cm³ |
| Resolution | 0.000001 g/cm³ |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Compatibility | Up to 50,000 mPa·s (via integrated vacuum-pressure pump) |
| Sample Vessel | 20 mL glass vial |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions (W×D×H) | 291 × 310 × 342 mm |
| Weight | 10 kg |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | D&S AERD |
| Pricing | Upon Request |
| Measurement Principle | Thermopile-based differential temperature method per ASTM C1371 |
| Wavelength Range | 3–30 µm |
| Emissivity Range | 0.01–1.00 |
| Repeatability | ±0.01 emittance units |
| Response Time | ~10 s |
| Display Accuracy | ±0.3% of reading |
| Operating Temperature | −10 to +40 °C |
| Dimensions (H×W×D) | 51 × 80 × 152 mm |
| Weight | ~370 g |
| Detector Output | ~2.5 mV |
| Power Supply | DC 9 V (host), AC 100–240 V (charger) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DCU-600 |
| Instrument Type | Oscillating U-tube Density Meter Accessory |
| Form Factor | Benchtop Laboratory Unit |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Temperature Control Range | 0–96 °C |
| Minimum Sample Volume | ~5 mL |
| Compatibility | Designed exclusively for KEM DA-640, DA-645, and DA-650 digital density meters |
| Automation Functions | Automated sample aspiration, measurement triggering, waste discharge, dual-solvent cleaning (Wash 1 & Wash 2), nitrogen-assisted drying, and cell integrity verification |
| Sample Vessel | 20–100 mL beaker or 100 mL disposable cup |
| Power Supply | DC 24 V, 5 A (AC adapter included) |
| Dimensions (W×D×H) | 214 × 295 × 304 mm |
| Weight | Approx. 5.5 kg |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | PD-31N / PD-31 |
| Measurement Principle | Transient Hot Wire Method |
| Dimensions (L×W×H) | 100 × 50 × 20 mm |
| Thermal Conductivity Range | 0.058–5.0 W/(m·K) |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Operating Temperature Range | −100 to +1000 °C |
| Measurement Duration | 100–120 s |
| Sample Dimensions | ≥100 × 80 × 40 mm (minimum two specimens) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-13N / PD-13 |
| Measurement Principle | Hot Wire Method |
| Dimensions (L×W×H) | 110 × 50 × 100 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.03–12 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Sample Size Requirement | ≥100 × 50 × 20 mm (sheet form) |
| Minimum Thickness for Film Samples | 0.1 mm (for k = 0.1 W/m·K), 5 mm (for k = 5 W/m·K) |
| Compatible With | QTM-710/QTM-700 (PD-13N), QTM-500 (PD-13) |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | WBGT-301 |
| Price | Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHD-502C |
| Instrument Type | Oscillating U-Tube Densimeter |
| Form Factor | Benchtop Laboratory System |
| Sample Phase | Liquid Only |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 1×10⁻⁶ g/cm³ |
| Density Repeatability | ±1×10⁻⁶ g/cm³ |
| Temperature Control | External Circulating Bath (4 °C to Ambient) |
| Sample Capacity | 30 × 20 mL Vials |
| Minimum Sample Volume | 1–2 mL |
| Viscosity Handling | Up to 50,000 mPa·s (via Integrated Vacuum-Pressure Pump) |
| Power Supply | AC 100–120 / 200–240 V, 50/60 Hz, ~40 W |
| Dimensions | 610 × 445 × 392 mm (W×D×H) |
| Weight | 24 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | AS-8030 |
| Instrument Type | Oscillating U-tube Densimeter Autosampler |
| Form Factor | Benchtop Laboratory Autosampler |
| Sample Phase | Liquid |
| Density Range Compatibility | 0–3 g/cm³ |
| Density Resolution Options | 0.000001 / 0.00001 / 0.0001 g/cm³ |
| Temperature Control Range | 0–100 °C (with Peltier regulation) |
| Repeatability | 0.000001 / 0.000005 / 0.00005 g/cm³ |
| Minimum Sample Volume | 10 mL |
| Sample Capacity | 30 positions (20 mL glass vials) |
| Compatible Instruments | KEM DA-860, DA-850, DA-840 digital densimeters |
| Power Supply | AC 100–240 V, 50/60 Hz, 45 W |
| Dimensions | 300 × 600 × 500 mm (W × D × H) |
| Weight | ~27 kg |
| Flow Unit Options | FU1–FU4 (pressure-driven or vacuum-driven sampling, multi-solvent cleaning, high-flow drying, sample recovery, co-wash functionality) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-11N / PD-11 |
| Measurement Principle | Transient Hot-Wire Method |
| Thermal Conductivity Range | 0.03–12 W/(m·K) |
| Accuracy | ±5% |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Sample Dimensions (min.) | 100 × 50 × 20 mm (for bulk solids) |
| Probe Form Factor | Encapsulated box-type sensor |
| Physical Dimensions (L×W×H) | 110 × 50 × 100 mm |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Models | KR2 (100×50 mm), KR6 (50×30 mm), KM1 (30×15 mm), K500B / K500B-20 (black, high-heat-flux surface-mount), K500S / K500S-20 (silver), K750 / K750S (embedded high-heat-flux), KW (water-cooled surface), TF-B/TF-C (robust embedded), TT-B/TT-C (robust surface), TC-B/TC-C (robust low-flux embedded), TV-B/TV-C (robust water-cooled) |
| Thermal Flux Ranges | 12–3,500 W/m² (low-flux) |
| Operating Temperature Ranges | −40–150°C (low-flux) |
| Accuracy | ±2% (low-flux), ±5% (surface high-flux), ±7% (embedded high-flux) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Benchtop Laboratory Densimeter & Refractometer |
| Measurement Principle | U-tube Oscillation for Density / Sodium D-line (589.3 nm) Critical Angle Refractometry |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±5×10⁻⁵ g/cm³ |
| Refractive Index Range | 1.3200–1.7000 nD |
| Refractive Index Accuracy | ±0.0001 nD |
| Temperature Control Range (Density) | 0–96 °C |
| Temperature Control Range (Refractometry) | 5–75 °C (optional up to 100 °C) |
| Sample Volume | ~1 mL |
| Temperature Resolution | 0.01 °C |
| Density Resolution | 0.00001 g/cm³ |
| Refractive Index Resolution | 0.0001 nD |
| Auto-sampling | Integrated Peltier-driven syringe pump |
| Calibration Standards | Air + distilled water or certified reference materials |
| Compliance | ASTM D1250, ISO 12185, ISO 2859, USP <841>, JP XVII General Tests 2.31 & 2.32, GLP/GMP-ready with audit trail capability |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Density Resolution | 1×10⁻⁶ g/cm³ |
| Density Repeatability | ±5×10⁻⁶ g/cm³ |
| Temperature Control Range | 0–96 °C (Peltier-regulated) |
| Temperature Accuracy | ±0.02 °C |
| Temperature Resolution | 0.001 °C |
| Minimum Sample Volume | 1–2 mL |
| Display | 5.7-inch TFT LCD with multi-language UI (English, Chinese, Japanese) |
| Compliance | ASTM D4052, ISO 12185, GB/T 29617, GB 5009.2, JJG 1058, BS EN ISO 15212-1 |
| Data Integrity | GLP-compliant audit trail, method storage (100 methods), calibration log, user access control |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | WBGT-203B |
| Price | Upon Request |
| WBGT Range | 0–50°C |
| Air Temperature Range | 0–50°C |
| Relative Humidity Range | 10–90% RH |
| Black Globe Temperature Range | 0–60°C |
| WBGT Accuracy | ±2°C (15–35°C) |
| Air Temp Accuracy | ±1°C (15–40°C) |
| RH Accuracy | ±3% RH (30–90%) |
| Black Globe Accuracy | ±1°C (20–60°C) |
| Alarm | Yes |
| Battery Life | ~70 hours continuous operation |
| Power Supply | Two AAA alkaline batteries (1.5 V each) |
| Weight | ~110 g |
| Accessories | Carrying case, batteries, operator manual |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | HFM-GP10 |
| Price Range | USD 7,000 – 14,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | WBGT-302 |
| Pricing | Available Upon Request |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | QTM-PA1 |
| Measurement Principle | Transient Hot Wire Method |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.03–12 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −10 to 200 °C |
| Standard Measurement Time | 60 s |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | PD-NO |
| Measurement Principle | Transient Hot Wire (THW) Method |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Accuracy | ±5% |
| Thermal Conductivity Range | 0.0116–0.1 W/m·K |
| Repeatability | ±3% |
| Operating Temperature Range | −100 to +180 °C |
| Standard Measurement Time | 40 s |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquids Only |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±5×10⁻⁵ g/cm³ |
| Density Resolution & Repeatability | 1×10⁻⁵ g/cm³ |
| Temperature Control Range | 0–96 °C (±0.03 °C) |
| Temperature Resolution | 0.01 °C |
| Minimum Sample Volume | 1 mL (manual), ~2 mL (auto-pump) |
| Measurement Time | ~20 s (stabilized sample), 2–10 min (full auto-cycle) |
| Display | 5.7″ TFT capacitive touchscreen (English/Chinese/Japanese UI) |
| Interfaces | LAN, USB 1.1, RS-232C |
| Compliance | ASTM D4052, D3505, D5002, D5931 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | DA-840 |
| Instrument Type | Oscillating U-tube Densimeter |
| Form Factor | Benchtop Laboratory Instrument |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±5 × 10⁻⁵ g/cm³ |
| Density Repeatability | ±5 × 10⁻⁵ g/cm³ |
| Temperature Range | 0–100 °C (Peltier-controlled) |
| Temperature Stability | ±0.01 °C |
| Resolution | 0.0001 g/cm³ |
| Minimum Sample Volume | 1 mL (manual), ~2 mL (auto-pump) |
| Measurement Time | ~10 s (to 4-digit precision) |
| Viscosity Correction | Automatic real-time correction |
| Bubble Detection | Integrated optical detection |
| Cleaning Mode | Fully automated rinse-dry cycle (vacuum + dual/triple wash + drying pump) |
| Interfaces | LAN, USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz, 40 W |
| Dimensions | 295 × 330 × 255 mm (W×D×H) |
| Weight | ~19 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Instrument Type | Laboratory Benchtop Oscillating U-Tube Densimeter |
| Sample Type | Liquid |
| Density Range | 0–3 g/cm³ |
| Density Accuracy | ±3×10⁻⁶ g/cm³ |
| Density Repeatability | ±1×10⁻⁶ g/cm³ |
| Density Reproducibility | ±2×10⁻⁶ g/cm³ |
| Temperature Control Range | 0–100 °C (Peltier-regulated) |
| Temperature Stability | ±0.001 °C |
| Resolution | 1×10⁻⁶ g/cm³ |
| Minimum Sample Volume | 1 mL (manual), ~2 mL (auto-pump) |
| Measurement Time | ~10 s to 4-digit precision |
| Viscosity Correction | Automatic real-time correction |
| Bubble Detection | Integrated optical detection |
| Cleaning Mode | Fully automated rinse-dry cycle (vacuum, dual/triple solvent wash, drying air) |
| Data Interface | LAN, USB, RS-232C |
| Power | AC 100–240 V, 50/60 Hz, 40 W |
| Dimensions | 295 × 330 × 255 mm (W×D×H) |
| Weight | ~19 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | QTM-710 / QTM-700 |
| Measurement Principle | Transient Hot Wire Method |
| Sample Form | Solid (bulk or sheet), including thin films (QTM-710 only) |
| Thermal Conductivity Range | 0.03–12 W/(m·K) |
| Repeatability | ±3% |
| Accuracy | ±5% (vs. certified reference materials at 23 °C) |
| Dimensions (L×W×H) | 262 × 276 × 158 mm |
| Weight | ~4 kg |
| Measurement Time | 60 s per test |
| Display | 5.7-inch color touchscreen |
| Operating Environment | 5–35 °C, <85% RH |
| Power Supply | DC 24 V / AC 100–240 V, 50/60 Hz |
| Interface | 2 × RS-232C, 2 × USB |
| Data Export | CSV via USB flash drive |
| Compliance | ASTM D5470, ISO 22007-2, GB/T 10297-2015, GB/T 5990-2006, GB/T 42919.1-2023, JJF 2221-2025 |