| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-611 |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric or Coulometric Karl Fischer Moisture Analyzer Compatible |
| Measurement Resolution | 0.1 µg |
| Moisture Content Range | 1 ppm to 100% |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 0–16 mL |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512S |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Volume | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz, ~600 W |
| Heating Temperature Range | 50–1000 °C |
| Evaporation Tube Material | Quartz |
| Sample Boat Material | Quartz |
| Sample Capacity | 10 mL |
| Dimensions | 835(W) × 340(D) × 345(H) mm |
| Weight | 18 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Model | MKV-710B |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Titration Accuracy (10 mL burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Repeatability | ±0.005 mL |
| Burette Unit | EBU-710-KF |
| Titration Control Precision | 0.015 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 Sample Records |
| GLP Compliance | Operator Logging, Reagent Tracking, Performance Verification, Time-Stamped Audit Trail |
| Connectivity | RS-232C, USB (Host & Device), SS-BUS (APB) |
| Optional Accessories | ADP-611 Coulometric/KF Oven, Solvent Exchange Unit, Dual Burette Module |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710M |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1/20,000 |
| Moisture Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Repeatability | ±0.005 mL |
| Burette Capacity | 10 mL |
| Titration Control Precision | 0.005 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKH-710M |
| Titration Mode | Fully Automated |
| Instrument Type | Dual-Mode Karl Fischer Moisture Analyzer (Volumetric & Coulometric) |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 500 mg H₂O |
| Accuracy | ±0.3% RSD (n=10) |
| Minimum Dispensing Increment | 0.1 µg |
| Repeatability | ±0.3% RSD |
| Burette Control Accuracy | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 measurement records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-513 |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg to 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Heating Temperature Range | Ambient to 200 °C |
| Evaporator Capacity | 100 mL |
| Evaporator Material | Transparent Heated Borosilicate Glass |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 210 × 330 mm |
| Weight | 6 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Coulometric + Volumetric) |
| Measurement Resolution | 0.1 µg |
| Moisture Range | 1 ppm to 100% H₂O |
| Accuracy | < 0.3% RSD (n = 10) |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.1 µg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage | Internal memory (500 samples for MKC-710M |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHK-501 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Sample Capacity | 24 positions |
| Heating Temperature Range | Ambient to 300 °C (individually programmable per sample) |
| Heater Type | Quartz Infrared Heater |
| Power Supply | AC 100–120 / 220–240 V, 50/60 Hz, ~100 W |
| Dimensions (W×D×H) | 452 × 400 × 362 mm |
| Weight | 20 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512 |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-344 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer Accessory |
| Measurement Resolution | 0.005 mL |
| Moisture Range | 10 ppm to 100% H₂O |
| Burette Accuracy (10 mL) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Titration Control Precision | ±0.5% |
| Heating Method | Surround-type heating of titration cell |
| Temperature Range | Ambient to 60 °C |
| Temperature Stability | ±3 °C |
| Power Supply | AC 100 V, 50/60 Hz, ~55 W |
| Dimensions (W×D×H) | 100 × 150 × 133 mm |
| Weight | 1.8 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (extendable to 1000 mg) |
| Accuracy | ≤0.3% RSD (n=10) |
| Minimum Electrolytic Generation Rate | 2.6 mg H₂O/min |
| Repeatability | <0.3% RSD |
| Cell Configuration | Membrane-type or Membrane-free Coulometric Titration Cell |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Compliance | GLP-ready with operator/group logging, reagent tracking, performance verification, and time-stamped audit trail |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKC-710B |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (equivalent to 100 ppb – 100% w/w) |
| Accuracy | ≤ 0.3% RSD (n = 10, per ASTM E1064 & GB/T 26793-2011) |
| Minimum Dosing Resolution | 0.1 µg |
| Titration Control Precision | ±0.3% of set current pulse duration |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710D |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Resolution | 0.005 mL |
| Moisture Range | 1 ppm – 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | ±0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKC-710M |
| Titration Mode | Fully Automatic Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (up to 1000 mg with optional configuration) |
| Accuracy | ≤0.3% RSD (n=10, certified reference materials) |
| Minimum Dosing Resolution | 0.1 µg |
| Repeatability | <0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| GLP Compliance | Operator logging, reagent tracking, performance verification, time-stamped audit trail |
| Communication Interfaces | RS-232C, USB (host/device), LAN |
| Expandability | Up to 4 titration units |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKC-710D |
| Titration Mode | Fully Automated Coulometric Titration |
| Method Type | Coulometric Karl Fischer Titration |
| Measurement Resolution | 0.1 µg H₂O |
| Moisture Content Range | 1 ppm – 100% w/w |
| Accuracy | ≤0.3% RSD (n=10) |
| Minimum Electrolytic Water Generation Rate | 2.6 mg H₂O/min |
| Titration Control Precision | ±0.3% |