- All
- Favorite
- Popular
- Most rated
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Type | Imported Instrument |
| Model | PCD-500 |
| Instrument Category | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Principle | Streaming Potential Detection |
| Electrode Output Range | ±2 V DC |
| Power Supply | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~10 W |
| Dimensions (W×D×H) | 250 × 210 × 400 mm |
| Weight | ~4.5 kg |
| Sample Handling | Stirred beaker-based immersion configuration |
| Piston Actuation | Continuously variable vertical reciprocation |
| Minimum Detectable Charge Concentration | ≥1 × 10⁻⁵ mol/L (dilution required for high-concentration samples) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-611 |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric or Coulometric Karl Fischer Moisture Analyzer Compatible |
| Measurement Resolution | 0.1 µg |
| Moisture Content Range | 1 ppm to 100% |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Volume | 0–16 mL |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512S |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Volume | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz, ~600 W |
| Heating Temperature Range | 50–1000 °C |
| Evaporation Tube Material | Quartz |
| Sample Boat Material | Quartz |
| Sample Capacity | 10 mL |
| Dimensions | 835(W) × 340(D) × 345(H) mm |
| Weight | 18 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Model | MKV-710B |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Titration Accuracy (10 mL burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.015 mL |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.005 mL |
| Water Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Repeatability | ±0.005 mL |
| Burette Unit | EBU-710-KF |
| Titration Control Precision | 0.015 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 Sample Records |
| GLP Compliance | Operator Logging, Reagent Tracking, Performance Verification, Time-Stamped Audit Trail |
| Connectivity | RS-232C, USB (Host & Device), SS-BUS (APB) |
| Optional Accessories | ADP-611 Coulometric/KF Oven, Solvent Exchange Unit, Dual Burette Module |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Type | Imported Instrument |
| Model | CHA-740 / CHA-760 |
| Instrument Category | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Potential Range | −2000.0 mV to +2000.0 mV |
| pH Range | −20.000 to +20.000 pH |
| Burette Accuracy | ±0.01 mL (20 mL burette) |
| Burette Resolution | 0.001 mL (20 mL burette) |
| Titration Precision | ±0.02 mL (20 mL burette) |
| Sample Capacity | 24 (CHA-740) / 47 (CHA-760) positions |
| Washing Modes | Rinse & Immersion, up to 3 wash solutions |
| Wash Liquids | Deionized water, ethanol, acetic acid, etc. |
| Operating Environment | 5–35 °C, ≤85 % RH |
| Power Supply | DC 24 V / 5 A (changer unit), AC 100–240 V / ~120 W |
| Dimensions (W×D×H) | 805×660×540 mm (CHA-740), 1005×760×540 mm (CHA-760) |
| Standard Sample Vessels | 200 mL plastic beakers, 200/250/300 mL glass beakers, tall-form beakers, Erlenmeyer flasks |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710M |
| Titration Method | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 1/20,000 |
| Moisture Content Range | 1 ppm to 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Repeatability | ±0.005 mL |
| Burette Capacity | 10 mL |
| Titration Control Precision | 0.005 mL |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKH-710M |
| Titration Mode | Fully Automated |
| Instrument Type | Dual-Mode Karl Fischer Moisture Analyzer (Volumetric & Coulometric) |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 500 mg H₂O |
| Accuracy | ±0.3% RSD (n=10) |
| Minimum Dispensing Increment | 0.1 µg |
| Repeatability | ±0.3% RSD |
| Burette Control Accuracy | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 measurement records |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | CHA-600 |
| Instrument Category | General-Purpose Automatic Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Ranges | pH: −20 to +20 |
| mV | −2000 to +2000 |
| Temperature | 0–100 °C |
| Burette Accuracy (20 mL) | ±0.01 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Titration Precision (20 mL) | ±0.02 mL |
| Sample Capacity | CHA-600-12: 12 × 200 mL (PP) or 300 mL tall-form beakers |
| CHA-600-18 | 18 × 100 mL (PP) or 50 mL beakers |
| Washing Method | Standard rinse (optional dual-solvent wash) |
| Washing Reservoir | Dedicated independent wash station |
| Wash Liquids | Deionized water, ethanol, acetic acid, or other compatible solvents |
| Stirring | Magnetic stir bar (optional propeller stirrer) |
| Ambient Operating Conditions | 5–35 °C, ≤85% RH |
| Power Supply | 100–120 V / 200–240 V AC, 50/60 Hz, ~50 W |
| Dimensions (W×D×H) | 520 × 426 × 369 mm |
| Weight | ~18 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-513 |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg to 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Heating Temperature Range | Ambient to 200 °C |
| Evaporator Capacity | 100 mL |
| Evaporator Material | Transparent Heated Borosilicate Glass |
| Power Supply | AC 100–120 V / 200–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 210 × 330 mm |
| Weight | 6 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Dual-Mode Karl Fischer Analyzer (Coulometric + Volumetric) |
| Measurement Resolution | 0.1 µg |
| Moisture Range | 1 ppm to 100% H₂O |
| Accuracy | < 0.3% RSD (n = 10) |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | 0.1 µg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage | Internal memory (500 samples for MKC-710M |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Kyoto Electronics Manufacturing Co., Ltd. |
| Model | MKC-710 |
| Measurement Principle | Coulometric Karl Fischer Titration |
| Moisture Range | 1 µg – 300 mg H₂O (up to 1000 mg with extended range) |
| Precision | RSD < 0.3% (n = 10, per certified reference materials and ASTM E203) |
| Electrode System | Dual-platinum detection electrodes with AC polarization |
| Cell Type | Membrane-separated or membrane-free electrolytic cell |
| Resolution | 0.1 µg H₂O |
| Max. Electrolysis Rate | 2.6 mg H₂O/min |
| Display | 8.4″ color LCD (800 × 600), multilingual UI (English, Japanese, Chinese, Korean, Russian, Spanish, German, French) |
| Data Storage | 500 sample results (MKC-710M), GLP-compliant audit trail, operator/group management, reagent lifetime tracking, scheduled performance verification |
| Interface | RS-232C × 4, USB × 1, SS-BUS, APBLAN |
| Environmental Operating Range | 5–35 °C, ≤85% RH |
| Power | AC 100–240 V ±10%, 50/60 Hz |
| Power Consumption | ~30 W (main unit), ~7 W (printer) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710B |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 mV |
| Temperature | 0 to 100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Burette Precision (20 mL) | ±0.01 mL |
| Burette Resolution Ratio | 1/20,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | CHK-501 |
| Titration Method | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg |
| Accuracy | ≤0.3% RSD |
| Titration Control Precision | 0.1 µg |
| Sample Capacity | 24 positions |
| Heating Temperature Range | Ambient to 300 °C (individually programmable per sample) |
| Heater Type | Quartz Infrared Heater |
| Power Supply | AC 100–120 / 220–240 V, 50/60 Hz, ~100 W |
| Dimensions (W×D×H) | 452 × 400 × 362 mm |
| Weight | 20 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-512 |
| Titration Mode | Fully Automatic |
| Instrument Type | Volumetric & Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 10 µg – 300 mg H₂O |
| Accuracy | ≤0.3% |
| Minimum Dispensing Increment | 0.1 µg |
| Titration Control Precision | ±0.3% |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | ADP-344 |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer Accessory |
| Measurement Resolution | 0.005 mL |
| Moisture Range | 10 ppm to 100% H₂O |
| Burette Accuracy (10 mL) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 of burette volume |
| Titration Control Precision | ±0.5% |
| Heating Method | Surround-type heating of titration cell |
| Temperature Range | Ambient to 60 °C |
| Temperature Stability | ±3 °C |
| Power Supply | AC 100 V, 50/60 Hz, ~55 W |
| Dimensions (W×D×H) | 100 × 150 × 133 mm |
| Weight | 1.8 kg |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Designation | Electrode Series for DV-100 / AT-710 / AT-710M Titrators |
| Measurement Range | ±20 pH, ±2000 mV |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | 0.001 pH, 0.1 mV |
| Titration Potential Stability | ±0.3 mV |
| Analog-to-Digital Resolution | 1/20000 (16-bit ADC) |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (extendable to 1000 mg) |
| Accuracy | ≤0.3% RSD (n=10) |
| Minimum Electrolytic Generation Rate | 2.6 mg H₂O/min |
| Repeatability | <0.3% RSD |
| Cell Configuration | Membrane-type or Membrane-free Coulometric Titration Cell |
| Titration Control Precision | ±0.3% |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Data Storage Capacity | 500 sample records |
| Compliance | GLP-ready with operator/group logging, reagent tracking, performance verification, and time-stamped audit trail |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | AT-Win |
| Instrument Type | Universal Potentiometric Titrator |
| Application Scope | General-purpose quantitative chemical analysis |
| Measurement Range | pH: –20.000 to +20.000 |
| mV | –2000.0 to +2000.0 |
| Temperature | 0 to 100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Electrode Readout Accuracy | ±0.01 mL (20 mL burette) |
| Digital Resolution | 1/20000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710S |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal Analytical Titration |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 |
| Temperature | 0–100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Electrode Reading Precision | ±0.01 mL |
| Burette Resolution Ratio | 1/20,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | MKC-710B |
| Titration Mode | Fully Automated Coulometric Titration |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Measurement Resolution | 0.1 µg |
| Water Content Range | 1 µg – 300 mg H₂O (equivalent to 100 ppb – 100% w/w) |
| Accuracy | ≤ 0.3% RSD (n = 10, per ASTM E1064 & GB/T 26793-2011) |
| Minimum Dosing Resolution | 0.1 µg |
| Titration Control Precision | ±0.3% of set current pulse duration |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710M |
| Instrument Type | General-Purpose Potentiometric Titrator |
| Application Scope | Universal Analytical Titration |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 |
| Temperature | 0 to 100 °C |
| Burette Accuracy (20 mL) | ±0.02 mL |
| Burette Resolution (20 mL) | 0.001 mL |
| Dispensing Precision (20 mL) | ±0.01 mL |
| Burette Resolution Ratio | 1/20,000 |
| Brand | KEM (Kyoto Electronics Manufacturing) |
|---|---|
| Origin | Japan |
| Manufacturer | Yes |
| Import Status | Imported |
| Model | MKV-710D |
| Titration Method | Fully Automated Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Moisture Analyzer |
| Resolution | 0.005 mL |
| Moisture Range | 1 ppm – 100% H₂O |
| Accuracy (10 mL Burette) | ±0.015 mL |
| Minimum Dispensing Increment | 1/20,000 |
| Titration Control Precision | ±0.015 mL |
| Brand | Kyoto Electronics Manufacturing (KEM) |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | AT-710 + CHA-700 |
| Instrument Type | General-purpose Potentiometric Titrator |
| Application Scope | Universal |
| Measurement Range | pH: −20.000 to +20.000 |
| mV | −2000.0 to +2000.0 |
| Temperature | 0 to 100 °C |
| Meter Accuracy | ±0.2% of full scale |
| Meter Resolution | pH: 0.001 pH |
| mV | 0.1 mV |
| Temperature | 0.1 °C |
| Titration Endpoint Precision | ±0.3 mV |
Show next