| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| Model | SW-CJ-1BU |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, ≥99.99% filter efficiency) |
| Noise Level | ≤67 dB(A) |
| User Configuration | Single-user, single-frontal workface |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Work Area Dimensions (W×D×H) | 910 × 480 × 570 mm |
| Overall Dimensions (W×D×H) | 910 × 790 × 1380 mm |
| HEPA Filter Specification | 815 × 575 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Illumination | ≥300 lx (20 W fluorescent lamp) |
| UV Germicidal Lamp | 20 W, timer-controlled (0–999 min) |
| Operating Wind Speed Range | 0.3–0.6 m/s (6-step adjustable) |
| Vibration Peak-to-Peak | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.15 kW |
| Net Weight | 110 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | SW-CJ-1CU |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-user, single-face configuration |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Work Surface Velocity Range | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Vibration Amplitude (peak-to-peak) | ≤10 µm (X/Y/Z axes) |
| Illumination | ≥300 lux (measured at work surface) |
| Work Area Dimensions (W×D×H) | 1570 × 480 × 570 mm |
| Overall Dimensions (W×D×H) | 1570 × 790 × 1380 mm |
| HEPA Filter Specifications | Two units — 600 × 575 × 50 mm and 815 × 575 × 50 mm |
| Pre-filter | Medium-efficiency panel filter |
| Lighting | One 40 W fluorescent lamp |
| UV Germicidal Lamp | One 40 W low-pressure mercury lamp with 0–999 min programmable timer |
| Control Interface | LCD display with tactile membrane switches |
| Construction Materials | Cold-rolled steel housing with epoxy powder coating |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power Consumption | 0.3 kW |
| Net Weight | 200 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SW-CJ-1CU |
| Instrument Type | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, ≥99.99% filter efficiency) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-user, single-front configuration |
| Airflow Pattern | Horizontal laminar flow |
| Working Surface Wind Speed | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Peak-to-Peak | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lx |
| Work Area Dimensions (W×D×H) | 1570 × 480 × 570 mm |
| Overall Dimensions (W×D×H) | 1570 × 790 × 1380 mm |
| HEPA Filter Specifications | 600 × 575 × 50 mm (1 pc) + 815 × 575 × 50 mm (1 pc) |
| UV Lamp & Fluorescent Lamp | 40 W × 1 each |
| Net Weight | 200 kg |
| Power Consumption | 0.3 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SW-CJ-1F |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-grade, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-operator, dual-front access |
| Airflow Pattern | Vertical downward laminar flow |
| Working Area Air Velocity | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Peak-to-Peak | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Working Chamber Dimensions (W×D×H) | 870 × 700 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 724 × 1650 mm |
| HEPA Filter Specification | 820 × 615 × 50 mm × 1 unit |
| Pre-filter | Medium-efficiency panel filter |
| UV Lamp | 20 W × 1 (timer-controlled, 0–999 min) |
| Fluorescent Lamp | 20 W × 1 |
| Net Weight | 110 kg |
| Power Consumption | 0.15 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SW-CJ-1F |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, dual-front access |
| Airflow Pattern | Vertical downward laminar flow |
| Working Surface Velocity Range | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Work Area Dimensions (W×D×H) | 870 × 700 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 724 × 1650 mm |
| HEPA Filter Specification | 820 × 615 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Lighting | 20 W fluorescent lamp (1 unit) |
| UV Germicidal Lamp | 20 W (1 unit, timer-controlled: 0–999 min) |
| Weight | 110 kg |
| Power Consumption | 0.15 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SW-CJ-1FD |
| Price Range | USD 700–1,400 (FOB) |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-face configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Working Surface Wind Speed | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Work Area Dimensions (W×D×H) | 870 × 700 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 724 × 1650 mm |
| HEPA Filter Specification | 820 × 615 × 50 mm (single unit) |
| Lighting | 20 W fluorescent lamp × 1 |
| UV Germicidal Lamp | 20 W × 1 (timer-controlled, 0–999 min) |
| Net Weight | 110 kg |
| Power Consumption | 0.15 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SW-CJ-1FD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, ≥99.99% HEPA filtration efficiency) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-face configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Working Area Air Velocity Range | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Displacement (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Working Chamber Dimensions (W×D×H) | 870 × 700 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 724 × 1650 mm |
| HEPA Filter Specification | 820 × 615 × 50 mm (single unit) |
| Lighting | 20 W fluorescent lamp × 1 |
| UV Germicidal Lamp | 20 W × 1 (timer adjustable 0–999 min) |
| Net Weight | 110 kg |
| Power Consumption | 0.15 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SW-CJ-2F |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-operator, dual-front configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Working Surface Velocity Range | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Work Area Dimensions (W×D×H) | 1300 × 650 × 520 mm |
| Overall Dimensions (W×D×H) | 1460 × 700 × 1650 mm |
| HEPA Filter Specification | 1250 × 560 × 50 mm (single unit) |
| Pre-filter | Medium-efficiency panel filter |
| Lighting | One 40 W fluorescent lamp |
| UV Germicidal Lamp | One 20 W low-pressure mercury lamp with 0–999 min timer |
| Weight | 210 kg |
| Power Consumption | 0.3 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SW-CJ-2F |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-user, dual-front configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Working Surface Velocity Range | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Peak-to-Peak Amplitude | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Work Area Dimensions (W×D×H) | 1300 × 650 × 520 mm |
| Overall Dimensions (W×D×H) | 1460 × 700 × 1650 mm |
| HEPA Filter Specification | 1250 × 560 × 50 mm (single unit) |
| Pre-filter | Medium-efficiency panel filter |
| Lighting | 40 W fluorescent lamp (1 unit) |
| UV Germicidal Lamp | 20 W (1 unit, timer-controlled: 0–999 min) |
| Weight | 210 kg |
| Power Consumption | 0.3 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | SW-CJ-2FD |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-grade, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-operator, single-front configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Working Surface Dimensions | 1300 × 650 × 520 mm (W×D×H) |
| Overall Dimensions | 1460 × 700 × 1650 mm (W×D×H) |
| HEPA Filter Specification | 1250 × 560 × 50 mm (single unit) |
| Pre-filter | Medium-efficiency panel filter |
| Air Velocity Range | 0.3–0.6 m/s (adjustable in six steps) |
| Illumination | ≥300 lux |
| UV Lamp | 20 W (timer-controlled, 0–999 min) |
| Fluorescent Lamp | 40 W |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 ±10 V, 50/60 Hz |
| Rated Power | 0.3 kW |
| Net Weight | 200 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SW-CJ-2FD |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Dual-operator, single-front configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Working Surface Air Velocity Range | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Vibration Peak-to-Peak Amplitude | ≤5 µm (X/Y/Z axes) |
| Illumination | ≥300 lux |
| Work Area Dimensions (W×D×H) | 1300 × 650 × 520 mm |
| Overall Dimensions (W×D×H) | 1460 × 700 × 1650 mm |
| HEPA Filter Specification | 1250 × 560 × 50 mm (single unit) |
| Pre-filter | Medium-efficiency panel filter |
| Lighting | 40 W fluorescent lamp (1 unit) |
| UV Germicidal Lamp | 20 W (1 unit, timer-controlled: 0–999 min) |
| Construction Materials | Cold-rolled steel housing with epoxy powder coating |
| Control System | LCD display with tactile membrane switches |
| Counterweight-balanced sash | Adjustable vertical positioning within operational range |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power Consumption | 0.3 kW |
| Net Weight | 200 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Model | VS-840-1 |
| Instrument Type | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, ≥99.99% HEPA filtration efficiency) |
| Airflow Pattern | Vertical Downflow |
| User Capacity | Single-user, front-access configuration |
| Operating Noise Level | ≤67 dB(A) |
| Work Area Dimensions (W×D×H) | 830 × 650 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 700 × 1650 mm |
| Average Face Velocity Range | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Illumination | ≥300 lux (fluorescent lamp, 20 W) |
| UV Germicidal Lamp | 20 W, timer-controlled (0–999 min) |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Filter Configuration | One 780 × 565 × 50 mm H14 HEPA filter (EN 1822-1), pre-filtered by a mid-efficiency panel filter |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Rated Power Consumption | 0.15 kW |
| Net Weight | 115 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-level, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-user, single-front configuration |
| Airflow Pattern | Vertical downward laminar flow |
| Work Area Dimensions (W×D×H) | 830 × 650 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 700 × 1650 mm |
| HEPA Filter Specification | 780 × 565 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Air Velocity Range | 0.3–0.6 m/s (adjustable in six discrete steps) |
| Illumination | ≥300 lx (20 W fluorescent lamp) |
| UV Sterilization Lamp | 20 W, timer-controlled (0–999 min) |
| Vibration Peak-to-Peak | ≤10 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.15 kW |
| Net Weight | 115 kg |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | VS-840-2 |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-grade, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-operator, dual-front access |
| Airflow Pattern | Vertical downward laminar flow |
| Work Area Dimensions (W×D×H) | 830 × 650 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 700 × 1650 mm |
| HEPA Filter Specification | 780 × 565 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Air Velocity Range | 0.3–0.6 m/s (adjustable in six steps) |
| Illumination | ≥300 lux |
| UV Lamp | 20 W × 1 (timer-controlled, 0–999 min) |
| Fluorescent Lamp | 20 W × 1 |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Weight | 120 kg |
| Power Consumption | 0.15 kW |
| Electrical Supply | AC 220 V ±10%, 50/60 Hz |
| Brand | BOXUN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | VS-840-2 |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100-grade, ≥99.99% filtration efficiency for particles ≥0.5 µm) |
| Noise Level | ≤67 dB(A) |
| User Capacity | Single-operator, dual-front access |
| Airflow Pattern | Vertical downward laminar flow |
| Working Area Dimensions (W×D×H) | 830 × 650 × 520 mm |
| Overall Dimensions (W×D×H) | 990 × 700 × 1650 mm |
| HEPA Filter Specification | 780 × 565 × 50 mm (1 unit) |
| Pre-filter | Medium-efficiency panel filter |
| Illumination | ≥300 lux (20 W fluorescent lamp × 1) |
| UV Sterilization Lamp | 20 W × 1 with 0–999 min timer |
| Air Velocity Range in Work Area | 0.3–0.6 m/s (adjustable in six steps) |
| Vibration Amplitude (peak-to-peak) | ≤5 µm (X/Y/Z axes) |
| Power Supply | AC 220 V ±10%, 50/60 Hz |
| Power Consumption | 0.15 kW |
| Net Weight | 120 kg |
| Brand | Captair |
|---|---|
| Model | Chemtrap V 201 |
| Dimensions (L×W×H) | 200 × 537 × 605 mm |
| Airflow Rate | 75 m³/h |
| Sound Pressure Level | 55 dBA |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 19 W |
| Current Draw | 0.1 A |
| Telescopic Duct Length | 1 m (Ø80 mm) |
| Flange Diameter Range | Ø75–110 mm |
| Filter Type | Activated Carbon-Based Molecular Filter (Organic Vapor Specific) |
| Filter Service Life | Approx. 12 months under typical lab usage |
| Compliance | NFX 15-211 Class 2 (France |
| Integrated Alarms | Fan Failure Alert, Filter Saturation Visual/Audible Alarm, Optional Saturation Detection Port (with external probe & pump) |
| Brand | Captair |
|---|---|
| Model | Venticap® 502 |
| Dimensions (L×W×H) | 570 × 390 × 270 mm |
| Sound Pressure Level | 57 dBA |
| Airflow Capacity | 75 m³/h |
| Power Supply | 220 V / 50 Hz |
| Power Consumption | 65 W |
| Current Draw | 0.8 A |
| Filtration Standard | Compliant with NFX 15-211 Class 2 (effluent concentration ≤ 50% of TLV) |
| Filter Type | Activated Carbon-Based Molecular Adsorption Media |
| Typical Service Life | 12 months under standard laboratory chemical storage conditions |
| Saturation Monitoring | Integrated outlet port with optional test kit |
| Alarm Functions | Visual and audible alerts for filter saturation and fan failure |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | LT |
| Construction Material | All-Steel Enclosure |
| Configuration | Single-Face Operation Fume Hood |
| Airflow System Options | Top Supply/Top Exhaust, Top Supply/Bottom Exhaust, Bottom Supply/Top Exhaust, Recirculating Mode, FFU-Equipped |
| Internal Cleanroom Class | ISO Class 5 (100-Particle Count) or ISO Class 4 (10-Particle Count) Available |
| Cabinet Liner Material | Lead-Free Flame-Retardant PVC Welded Panels |
| Customization | Yes — including Class 100 Cleaning Cabinets, Central Sampling Cabinets, and Class 100 Drying Cabinets |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SC2-60F-0806D1-CL |
| Compliance | EN 14470-1:2004, EN 1363-1 |
| Fire Resistance Rating | 60 min |
| Max Internal Temp Rise Limit | ≤180 °C |
| Auto-Closure Trigger Temp | 50 °C (door), 70–100 °C (vents) |
| Load Capacity per Shelf | 80 kg |
| Shelf Thickness | 30 mm |
| Internal Volume | 89 L |
| Internal Dimensions (W×D×H) | 505 × 419 × 422 mm |
| External Dimensions (W×D×H) | 600 × 610 × 820 mm |
| Weight | 106 kg |
| Shelf Material Options | PP, stainless steel, corrosion-resistant coated steel |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SC3-30F-1912D2-C |
| Compliance | EN 14470-1:2004, EN 1363-1 |
| Fire Resistance Rating | 30 min |
| Internal Volume | 802 L |
| Internal Dimensions (W×D×H) | 968 × 507 × 1635 mm |
| External Dimensions (W×D×H) | 1101 × 630 × 1951 mm |
| Shelf Capacity | 3 standard / up to 5 shelves |
| Max. Load per Shelf | 80 kg |
| Shelf Thickness | 30 mm |
| Self-Closing Mechanism Activation | 50 °C |
| Vent Closure Temperature | 70–100 °C |
| Weight | 330 kg |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SC3-90F-1912D2-C / SC3-90F-0812D2D-C |
| Fire Resistance Rating | 90 min (EN 14470-1:2004) |
| Internal Temperature Limit | ≤180 °C during fire exposure |
| Auto-Closing Mechanism | Door seals at 50 °C, ventilation shutters close at 70–100 °C |
| Construction | Welded steel frame with double-walled insulation |
| Shelf Load Capacity | up to 80 kg per shelf |
| Internal Volume | up to 763 L (vertical), 244 L (horizontal) |
| Compliance | EN 1363-1, EN 14470-1, DIN 4102-1 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TC3-KE-025, TC3-ME-025 |
| Temperature Range | −40 °C to +150 °C (TC3-KE), −20 °C to +150 °C (TC3-ME) |
| Chamber Volume | 25 L |
| Temperature Uniformity (at 50 °C) | ±0.3 °C |
| Temperature Stability (at 50 °C) | ±0.5 °C |
| Heating Time (0 °C → 90 °C) | 60 min (TC3-KE), 50 min (TC3-ME) |
| Cooling Time (90 °C → 0 °C) | 70 min (TC3-KE), 50 min (TC3-ME) |
| Programmable Logic | 100 programs × 100 segments × 999 repeats |
| Control Interface | 5.6″ color touchscreen |
| Compliance | DIN 12880, IEC 60068-3-5, FDA-registered device |
| Communication | RS-232 standard, RS-485 optional (up to 32 units daisy-chained) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TH-ICH-300 |
| Chamber Volume | 300 L |
| Temperature Range | –5 to +85 °C (with humidity), 0 to +85 °C (without humidity, lamp off), 15 to +85 °C (with humidity & lamp on) |
| Humidity Range | 20–85 %RH |
| Temp. Uniformity | ±0.3 °C at 40 °C / 60 %RH |
| Humidity Uniformity | ±3 %RH at 40 °C / 60 %RH |
| Lighting Option (ICH Q1B) | Cold White Light (6,000 lux), UVA Radiation (4.5 W/m²), Illuminance Uniformity: VIS ±10%, UVA ±15% |
| Refrigeration System | Air-cooled single-stage compressor with R-404A |
| Power Supply | AC 230 V, 1 ph, 50/60 Hz |
| Current Rating | 14.7 A (50 Hz) / 15.4 A (60 Hz) |
| Compliance | DIN 12880, IEC 60068, ICH Q1A(R2), ICH Q1B |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | TH3-KE-025 |
| Temperature Range | −40 to 150 °C |
| Humidity Range | 20–95 %RH |
| Internal Volume | 25 L |
| Temperature Uniformity (at 50 °C) | ±0.3 °C |
| Humidity Uniformity | ±1 %RH |
| Heating Time (0 → 90 °C) | 60 min |
| Cooling Time (90 → 0 °C) | 70 min |
| Power Supply | AC 230 V, 1-phase, 50/60 Hz, 9.7 A |
| Compliance | DIN 12880, IEC 60068 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | WIND XL 500H |
| Nitrogen Purity Range | 95–99.999% |
| Nitrogen Flow Rate | 100–2000 N·L/min |
| Max Direct Output Pressure | 7.5 bar |
| Max Boosted Pressure | 20 bar |
| Display | 10-inch color touchscreen |
| Air inlet pretreatment | multi-stage filtration + refrigerated dryer |
| Noise level | 73 dB(A) ± 2 |
| Enclosure rating (air compressor motor) | IP54 |
| Communication interfaces | RS232, analog I/O, alarm relay outputs |
| Safety features | low-pressure alarm, auto-depressurization at shutdown, compressor overtemperature protection |
| Compliance | Designed for GLP/GMP-adjacent environments |
| meets ISO 8573-1 Class 2 | 2:2 for compressed air quality upstream of PSA unit |
| Brand | Chuanheng Instrument |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Direct Manufacturer |
| Equipment Category | Vertical Laminar Flow Clean Bench |
| Model | SW-CJ-1D |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Average Air Velocity | 0.25–0.45 m/s (dual-speed control) |
| Noise Level | ≤62 dB(A) |
| User Configuration | Single-user, front-access |
| Airflow Pattern | Vertical downward laminar flow |
| Work Area Dimensions | 700 × 500 × 520 mm |
| Overall Dimensions | 850 × 580 × 1550 mm |
| Power Supply | AC 220 V, 50 Hz |
| Rated Power | 0.3 kW |
| HEPA Filter | 695 × 460 × 38 mm, single unit |
| Lighting | 15 W fluorescent lamp + 15 W UV germicidal lamp |
| Control | Infrared remote (fan speed high/low, lighting, UV sterilization, power on/off) |
| Brand | CZGY |
|---|---|
| Model | RH-150 |
| Construction | Fully Welded 304 Stainless Steel Frame |
| Work Surface Dimensions | 150 mm × 150 mm |
| Load Capacity | ≤25 kg (static, evenly distributed) |
| Height Adjustment Range | 70–120 mm (manual screw-driven mechanism) |
| Compliance | Designed for ISO/IEC 17025 laboratory environments |
| Surface Finish | Electro-polished, Ra ≤0.8 µm |
| Corrosion Resistance | ASTM A967 compliant passivation treatment |
| Brand | DreamLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DL-BE150H |
| Pricing | Upon Request |
| Brand | DreamLab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Models | DL-BE80V / DL-BE80VT / DL-BE120V / DL-BE120VT |
| Pricing | Upon Request |
| Brand | DreamLab (Junlebo) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | DL-RC60S / DL-RC120S |
| Pricing | Upon Request |