- All
- Favorite
- Popular
- Most rated
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | P8000-PT |
| Product Type | Automatic Polarimeter |
| Measurement Principle | Optical Rotation at 589 nm (Na D-line) |
| Temperature Control | Integrated Peltier-Heated/Cooled Sample Cell (PRG-100-EPT) |
| Measurement Range | ±90° / ±259 °Z / 0–99.9 g/100 mL |
| Resolution | 0.001°, 0.01 °Z, 0.1 g/100 mL |
| Accuracy | ±0.003°, ±0.01 °Z, ±0.5 g/100 mL |
| Repeatability | 0.002° |
| Measurement Time (±90°) | 1 s |
| Wavelength | 589 nm (LED source, optional alternate wavelengths available) |
| Cell Path Length | 220 mm |
| Temperature Range | 15.0–40.0 °C |
| Temp. Resolution | 0.1 °C |
| Temp. Accuracy | ±0.2 °C |
| Display | 5.7″ TFT LCD (320 × 240 px) |
| Interface | RS-232, USB, Ethernet |
| Data Storage | 999 measurements |
| Power | 90–250 V, 50/60 Hz |
| Dimensions | 64.5 × 20.0 × 36.0 cm |
| Weight | 28 kg |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | P3000 |
| Product Type | Automatic Polarimeter |
| Temperature Control | None |
| Digital Display | Yes |
| Light Source | LED |
| Measurement Range | ±90°, ±259°Z |
| Resolution | 0.01°Z |
| Accuracy | ±0.01°Z |
| Repeatability | 0.01° |
| Measurement Time (±90°) | 1 s |
| Wavelength | 589 nm (fixed) |
| Temperature Monitoring Range | 0–99.9 °C |
| Temperature Resolution | 0.1 °C |
| Sample Cell Length | 220 mm |
| Calibration | Menu-driven automatic calibration |
| Display | 5.7-inch LCD (320 × 240 px) |
| Interface | RS-232 |
| Power Supply | 90–250 V, 50/60 Hz |
| Dimensions (W×D×H) | 64.5 × 20.0 × 36.0 cm |
| Weight | 28 kg |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | P1000-LED |
| Instrument Type | Circular Polarimeter |
| Light Source | LED |
| Measurement Range | ±180° (2 half-circles) |
| Angular Scale Division | 1° |
| Reading Accuracy | ±0.05° (vernier scale) |
| Sample Tube Length | 100–200 mm (standard 220 mm cell chamber) |
| Dimensions (W×D×H) | 14.0 × 33.0 × 50.0 cm |
| Weight | 4.3 kg |
| Temperature Control | None |
| Display | Analog (optical vernier, no digital readout) |
| Compliance | Designed per ISO 13871 and ASTM E1254 for manual polarimetric measurement |
| Brand | KRUESS |
|---|---|
| Origin | Germany |
| Model | P8000-DT |
| Sample Cell Temperature Control | Yes (Peltier, −15 °C to 40.0 °C, ±0.2 °C accuracy) |
| Display | 5.7″ TFT touchscreen (320 × 240 px) |
| Light Source | LED with 589 nm filter (optional alternate wavelengths) |
| Measurement Range | ±90° optical rotation, ±259 °Z, 0–99.9 g/100 mL |
| Resolution | 0.001°, 0.01 °Z, 0.1 g/100 mL |
| Accuracy | ±0.003°, ±0.01 °Z, ±0.5 g/100 mL |
| Repeatability | 0.002° |
| Measurement Time (full range) | 1 s |
| Sample Handling | Semi-automated fluidic sampling with integrated rinse & dry cycle |
| Wetted Materials | PTFE, PFA, Viton®, borosilicate glass |
| Data Storage | 999 measurements |
| Interfaces | RS-232, USB, Ethernet |
| Power | 90–250 V AC, 50/60 Hz |
| Dimensions (W×D×H) | 64.5 × 20.0 × 36.0 cm |
| Weight | 28 kg |
Show next