| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/9 |
| Measurement Principle | Tristimulus Filter-Based Photometry |
| Light Source | Tungsten Halogen Lamp |
| Standard Cuvette | 10 mm Pathlength Glass Cell |
| Supported Color Scales | Lovibond®, Hunter Lab, CIELAB (L*C*h°), CIE XYZ, CIE Yellowness Index (YI), CIE Whiteness Index (WI), Spectral Data Output (31-point, 400–700 nm) |
| Interface | RS-232 & USB |
| Software Included | RCMSi Calibration & Data Management Suite for Windows |
| Compliance | ISO 4630 (Petroleum Products), ISO 27677 (Beer), AOAC Official Methods, ASTM D1209/D5386/D6290 |
| Calibration | Factory-Calibrated with NIST-Traceable Standards |
| Dimensions | 280 × 220 × 180 mm |
| Weight | 4.2 kg |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/5 |
| Compliance Standards | EP, USP, Pt-Co/Hazen/APHA, CIE L*a*b*, CIE XYZ, Spectral Data |
| Interface | USB & LAN (RCMSi Remote Calibration and Maintenance System) |
| Display | Large backlit LCD with multilingual UI (including Chinese) |
| Sample Holders | Compatible with multiple pathlength cuvettes (10–50 mm), optional flow-through cell |
| Construction | Stainless steel measurement chamber, chemical-resistant housing |
| Software | Included Color Control Software for spectral visualization, CIE chromaticity diagrams, data export, instrument remote control, GLP-compliant reporting |
| GLP Features | Date/time stamp, user ID, sample ID, audit trail, password protection |
| Customization | User-defined color standards, selectable display parameters, language selection, access-level passwords |
| Delta-E & Bias Analysis | Quantitative deviation reporting (ΔL*, Δa*, Δb*, ΔE*ab, hue angle, saturation ratio, bias factor) |
| Calibration | Certified liquid standards (ISO/IEC 17025 traceable per ASTM D1209, D5386 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF329 |
| Measurement Range | 0–500 Pt-Co Units |
| Compliance | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Application Scope | Clear, pale-yellow liquids only |
| Optical System | Visual comparator with standardized glass color standards |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF325 |
| Compliance | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Light Source | Daylight 2000 Illumination System |
| Cell Path Length | 113 mm |
| Measurement Principle | Visual Comparison Against Pt-Co Standard Glass Discs |
| Color Scale | Pt-Co / Hazen / APHA (0–500 units) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | Model F |
| Optical Principle | Visual color matching against calibrated glass color standards |
| Illumination | Standardized D65 daylight simulator with controlled viewing geometry |
| Viewing System | Dual-field comparator with fixed 45°/0° optical path |
| Sample Format | Liquid or semi-solid in standard 10 mm or 25 mm pathlength cuvettes |
| Compliance | ASTM D1500, ISO 2049, AOCS Cc 13b-92, IP 15, BS 684-2.17 |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF330 |
| Measurement Range | EBC 2–27 |
| Wavelength | 430 nm (fixed, optimized for EBC scale) |
| Optical Path Length | Standard 10 mm cuvette (compatible with 5 mm, 20 mm, and 50 mm pathlength cells for sample dilution or concentration adjustment) |
| Compliance | Designed in accordance with EBC Method 2.1 & ASBC Beer-1 |
| Display | LED digital readout with EBC unit labeling |
| Power Supply | AC adapter or optional rechargeable battery pack |
| Dimensions | 185 × 120 × 85 mm |
| Weight | 0.9 kg |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | Germany |
| Model | EC2000 Visual-Electronic Gardner Colorimeter |
| Measurement Principle | Visual-electronic dual-mode Gardner color assessment using standardized glass filters and reference liquids |
| Display | 4.3-inch capacitive touchscreen |
| Light Path Options | 10 mm, 20 mm, 30 mm, 50 mm (user-selectable) |
| Cuvette Materials | Optical-grade glass or disposable polystyrene |
| Power Supply | AC adapter (100–240 V) + internal rechargeable Li-ion battery (≥8 h operation) |
| Data Storage | ≥20,000 measurement records with timestamp, sample ID, operator ID, and color index |
| Connectivity | USB-A port for data export (CSV/Excel-compatible) |
| Calibration Verification | Dual-method — certified Gardner filter set + NIST-traceable liquid reference standards |
| Compliance | Meets ASTM D156, ASTM D6166, ISO 4630, and IP 15 for Gardner color scale determination |
| Environmental Operating Range | 10–40 °C, 20–80% RH non-condensing |
| Dimensions | 220 × 120 × 95 mm |
| Weight | 1.2 kg (with carrying case) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/8 |
| Measurement Standards | ADMI, Pt-Co/Hazen/APHA, CIE L*a*b*, CIE XYZ, Spectral Data (380–780 nm, 10 nm intervals) |
| Display | 7-inch TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO 9001, ISO/IEC 17025 (via certified reference standards), ASTM D1209, ASTM D5386, ISO 6271, ISO 2211 |
| GLP Support | Date/time stamp, sample ID, operator ID, audit trail export |
| Sample Cell Compatibility | 10–50 mm pathlength cuvettes (rectangular, round, flow-through optional) |
| Housing | Stainless steel chassis with chemical-resistant anodized aluminum front panel |
| Calibration | RCMSi Remote Calibration Management System enabled |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | AF607 |
| Light Source | Tungsten-halogen lamp compliant with CIE Illuminant B |
| Viewing System | Triple-field visual comparator |
| EBC Scale Range | 2–27 units |
| Resolution | ±0.5 EBC (2–10), ±1.0 EBC (10–27) |
| Compliance | EBC Method No. 3.1.1, ASBC Beer-1, ISO 4833-1:2013 (applicable for color standardization in brewing) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | PFXi195 Series |
| Price Range | USD 6,800 – 13,600 (FOB UK) |
| Light Source | Tungsten Halogen Lamp |
| Cell Material | Stainless Steel Cuvette Holder |
| Calibration | RCMSi-certified Verification Kit Included |
| Software | Windows-based Lovibond® ColorSoft v5.x |
| Compliance | ASTM D1209, D1500, D5386 |
| Data Interface | USB 2.0 |
| Display | Backlit LCD with On-Screen Guidance |
| User Access Control | Password-protected Admin Mode |
| Maintenance | Tool-free Cuvette Tray Removal & Lamp Replacement |
| Brand | Lovibond/Tintometer |
|---|---|
| Origin | United Kingdom |
| Model | AF327 |
| Color Scale | Pt-Co/Hazen/APHA (0–500 units) |
| Light Source | Daylight 2000 Illumination System |
| Comparator Type | Visual Nessleriser with 288 mm Path Length |
| Compliance | ASTM D1209, AOCS Td 1b-64, ISO 2211, ISO 6271, BS 5339 |
| Brand | Lovibond (Tintometer Ltd) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi 880F |
| Measurement Principle | Tristimulus Filter Photometry |
| Standard Color Scales | Lovibond® RYBN, APHA/Pt-Co, Gardner, Saybolt, ASTM D1209/D5386/D6166, ISO 2764, ISO 4630, USP <631>, CIE L*a*b*, CIE XYZ, ΔE*ab |
| Display | High-contrast 7-inch TFT color touchscreen |
| Data Output | USB 2.0, Ethernet (LAN), RS232 |
| Compliance | CE, UKCA, RoHS, FDA 21 CFR Part 11 ready (audit trail & electronic signature support via optional software license) |
| Calibration | Factory-certified with RCMSi initial verification kit |
| Sample Cell Compatibility | 10 mm, 25 mm, 33 mm, 50 mm pathlength cells (1" and 5.25" round cells included) |
| Light Source | Tungsten-halogen lamp (3000 K CCT, stable spectral output per IEC 61000-4-11) |
| Repeatability | ≤ ±0.1 Lovibond unit (RYBN), ≤ ±0.3 APHA units (typical, under controlled lab conditions) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi995 Automated Colorimeter |
| Optical Path Length | Up to 153 mm (6") |
| Compliance Standards | AOCS, ASTM D1500, ASTM D1209, ISO 2761, ISO 4630, ISO 6271, USP <631>, CIE 1931 & CIE 1976 (L*a*b*) |
| Data Interfaces | USB 2.0, 10/100 Mbps Ethernet (LAN) |
| Display | High-contrast backlit LCD with multilingual GUI (including English, German, French, Spanish, Chinese) |
| Software | Windows-based Lovibond ColorSoft v5.x with GLP audit trail, user management, and RCMSi remote calibration verification |
| Light Source | Tungsten-halogen lamp (replaceable) |
| Construction | Stainless steel housing with chemical-resistant coating |
| Optional Accessories | Integrated sample heater (for solid-to-liquid transition), custom filter sets, 1", 5.25", 10 mm, and 100 mm pathlength cells |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF650 |
| Light Source | CIE Standard Illuminant C (Halogen Tungsten Lamp) |
| Viewing Mode | Tristimulus Triple-Field Visual Comparison |
| ASTM D1500 Range | 0.5 to 8.0 (in 0.5-unit increments) |
| Compliant Standards | ASTM D1500, ISO 2049, DIN 51578, BS 5859, JIS K 2580, NF T60-104, NB NT 52-109, FTM 719-102 |
| Sample Types | Lubricating oils, diesel fuel, heating oil, mineral insulating oils, paraffin wax, and other transparent petroleum distillates |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/6 |
| Measurement Principles | Absorption photometry at fixed wavelengths & full-spectrum reflectance/transmittance |
| Standard Methods Supported | Pt-Co/Hazen/APHA, Gardner, Saybolt, ASTM D1209, ASTM D5386, ISO 6271, ISO 2761, CIE L*a*b*, CIE XYZ, Klett (Blue Filter KS-42), Hess-Ives |
| Display | 7-inch high-resolution TFT LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0, 10/100 Mbps Ethernet (LAN), RS-232 optional |
| Data Storage | Internal memory for ≥2,000 measurements with GLP-compliant metadata (date/time, operator ID, sample ID, method ID) |
| Compliance | ISO/IEC 17025 traceable calibration standards available |
| Sample Format | Compatible with 10–50 mm pathlength glass or quartz cuvettes |
| Construction | Stainless steel optical chamber housing with chemical-resistant anodized aluminum chassis |
| Light Source | Long-life halogen tungsten lamp with stabilized power supply and automatic intensity compensation |
| Wavelength Range | 380–780 nm (full-spectrum mode) |
| Repeatability | ≤0.1 ΔE*ab (CIE 1976) for stable samples under controlled conditions |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | RT700 |
| Measurement Principles | CIE-compliant 0°/d geometry (diffuse illumination, 0° viewing) |
| Illuminants | D65, A, C, F2, F7, F11 |
| Observer Angle | 2° and 10° standard observer |
| Color Spaces | CIE XYZ, Yxy, L*a*b*, Hunter LAB, L*C*h°, CMC (l:c), CIE94, DIN6172, Whiteness (CIE, Ganz, ASTM E313), Yellowness (ASTM D1925, E313), Delta E (ΔE*ab, ΔE00, ΔE94) |
| Repeatability | ≤0.08 ΔE*ab (white tile, 10 readings) |
| Lamp Type | Tungsten-halogen (long-life, stable output) |
| Aperture Options | 8 mm, 12 mm, 20 mm (user-selectable) |
| Display | High-contrast LCD with intuitive icon-based interface |
| Connectivity | USB port for data export and firmware updates |
| Compliance | ISO 5-4:2022, ISO 7724-1:2022, ASTM D2244, ASTM E308, CIE No. 15:2018 |
| Software Compatibility | OnColor™ v5.x (Windows-based, supports GLP audit trail, user access levels, report generation per ISO/IEC 17025) |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF229 |
| Light Source | CIE Illuminant C (Tungsten-Halogen Lamp) |
| Color Scale | FAC (Fats Analysis Committee) Scale |
| Measurement Method | Visual Tristimulus Comparison |
| Compliance | AOCS Official Method Cd 13b-92 |
| Configuration | Standard Unit with Dual Reference Discs |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF509/C |
| Standard Color Scale | ASTM D1500 (0.5–8.0 in 0.5-unit increments) |
| Included Glass Standards | 7 color discs (1.0 to 5.0 ASTM units) |
| Sample Compatibility | Diesel fuel (F-76), lubricating oils, heat transfer oils, mineral insulating oils, paraffin wax |
| Compliance | Fully aligned with ASTM D1500, ISO 2049, and IP 15 |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/3 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), Gardner, FAC, APHA/Pt-Co, Saybolt |
| Display | High-contrast backlit LCD with multi-language UI (including Chinese) |
| Interface | USB 2.0 & 10/100 Mbps Ethernet (LAN) |
| Compliance | ISO/IEC 17025 traceable standards support (ASTM D1500, ASTM D6166, ISO 4630, ISO 27875, ISO 6271), GLP-compliant data logging |
| Sample Handling | Removable stainless-steel measurement cell, flow-through cuvette option available |
| Software | Included Lovibond Colour Control Software (Windows-compatible), CIE chromaticity diagram visualization, spectral reflectance/data export (CSV, XML), remote instrument control |
| Data Management | User ID, sample ID, timestamp, method ID, and deviation metrics (ΔE*, Δa*, Δb*, saturation ratio, hue angle offset) stored per measurement |
| Enclosure | Corrosion-resistant stainless-steel housing |
| Power | 100–240 V AC, 50/60 Hz |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | PFXeo |
| Measurement Principle | Absorption Photometry at Defined Wavelengths |
| Optical System | Single-beam Spectrophotometric Colorimeter |
| Light Source | Tungsten-Halogen Lamp |
| Spectral Range | 380–780 nm |
| Wavelength Accuracy | ±0.2 nm |
| Spectral Bandwidth | <15 nm |
| Photometric Range | 0–100% Transmittance (T) |
| Photometric Linearity | ±0.01% T |
| Stray Light | <0.01% T |
| Repeatability | ±0.5% T |
| Detector Type | Silicon Photodiode Array |
| Sample Temperature Control | Integrated Peltier Heater (Ambient to +60°C) |
| Display | Real-time Sample Temperature & Color Value |
| Sample Cell Options | 25 mm (1") and 133 mm (5.25") pathlength cuvettes, sealed & chemically resistant |
| Housing Material | Recyclable anodized aluminum (100% recyclable) |
| Dimensions | 301 × 152 × 331 mm (W×H×D) |
| Weight | 5.16 kg |
| Operating Environment | 5–40°C, ≤90% RH (non-condensing) |
| Storage | −20–+85°C, ≤90% RH (non-condensing) |
| Power Supply | 190–240 V AC |
| Interfaces | USB 2.0, RS-232 |
| Compliance | CE Marked |
| Supported Standards | Lovibond® RYBN, Lovibond RY10:1, AOCS Cc 13b-45 / Cc 8d-55 / Cc 13j-97 / Cc 13e / Cc 13j, ISO 15305, IP 17, MS 252 Part 16, GB/T 22460-2008 |
| Languages | English, Chinese, French, German, Italian, Spanish, Portuguese, Russian, Japanese |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | AF334 (Gardner Scale) |
| Measurement Range | Gardner Scale 1–18 |
| Compliance | ASTM D1544, ISO 4630, DIN 6162-1 |
| Light Source | Tungsten-halogen lamp with stable spectral output |
| Viewing Geometry | 0°/45° (single-beam, visual comparison design) |
| Optical Path | Fixed 10.0 mm cell pathlength |
| Calibration | Pre-calibrated with NIST-traceable Gardner liquid standards |
| Dimensions | 220 × 120 × 180 mm |
| Weight | 2.1 kg |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Brand | Lovibond (Tintometer Ltd.) |
|---|---|
| Origin | United Kingdom |
| Model | EC2000 Visual-Electronic Platinum-Cobalt Colorimeter |
| Measurement Principle | Visual-electronic comparison against Pt-Co (APHA) standard scale |
| Calibration Options | Certified glass filter set + reference liquid standards |
| Light Path Options | 10 mm, 20 mm, 50 mm (user-selectable) |
| Cuvette Materials | Optical-grade glass or disposable polystyrene |
| Display | 4.3-inch capacitive touchscreen with color-coded pass/fail indicators (green/amber/red) |
| Data Storage | >20,000 measurement records with timestamp, sample ID, operator ID, and method tag |
| Connectivity | USB-A port for data export (CSV format) |
| Power Supply | AC adapter (100–240 V) + internal rechargeable Li-ion battery (≥8 h continuous operation) |
| Enclosure | IP54-rated ruggedized housing |
| Compliance | Designed to support ASTM D1209, ISO 6271, ISO 7887, and USP <631> color assessment protocols |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/7 |
| Measurement Standards | ICUMSA, Pfund, Series 52 (Brown), CIE L*a*b*, Spectral Reflectance/Transmittance |
| Interface | USB & LAN |
| Display | Large backlit LCD |
| Language Support | Multilingual (including Chinese) |
| GLP Compliance | Date/Time stamp, Sample ID, Operator ID logging |
| Construction | Stainless steel measurement cell housing |
| Cell Compatibility | Standard cuvettes (10–50 mm pathlength), optional flow-through cell |
| Software | Included Lovibond Colour Control Software (CIE chromaticity diagrams, spectral data export, remote instrument control) |
| Calibration | Certified liquid standards (ISO/IEC 17025 traceable per ASTM D1209, D1500, D5386 |
| Remote Maintenance | RCMSi Network Verification System |
| Brand | Lovibond (Tintometer) |
|---|---|
| Origin | United Kingdom |
| Model | PFXi195/2 |
| Measurement Principles | Tristimulus colorimetry (CIE 1931 XYZ), spectral reflectance (31-wavelength LED array) |
| Standards Supported | ASTM D1500 (Petroleum), ASTM D156 (Saybolt), ASTM D5386 (Color by Instrument), ISO 2764 (Pt-Co/Hazen/APHA), ISO 4630 (Gardner), CIE L*a*b*, CIE Yxy, ΔE*ab |
| Display | 7-inch TFT LCD with multi-language UI (including English, Chinese, Spanish, French, German) |
| Interface | USB 2.0, 10/100 Mbps Ethernet (LAN), RS-232 optional |
| Data Storage | Internal memory for ≥10,000 results with GLP-compliant audit trail (date, time, operator ID, sample ID, method ID) |
| Sample Compartment | Removable stainless-steel cell holder, compatible with 10–50 mm pathlength cuvettes (glass, quartz, disposable plastic) |
| Calibration | Factory-calibrated with NIST-traceable liquid standards |
| Enclosure | IP54-rated stainless-steel chassis with chemical-resistant coating |
| Software | Lovibond ColorControl v5.x (Windows), supports CIE chromaticity diagrams, spectral curve overlay, deviation analysis (ΔL*, Δa*, Δb*, ΔE*ab), custom standard creation, and 21 CFR Part 11–compliant user access control |
Show next