| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | JK-JG8000 |
| Price | USD 10,800 (FOB Beijing) |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.01–2000 µm |
| Repeatability | <0.5% RSD (D50 of NIST-traceable standard) |
| Measurement Time | <2 min per run |
| Standard Compliance | ISO 13320:2020, GB/T 19077–2016, Q/0100JWN001–2013 |
| Detector Channels | 127 |
| Primary Laser | He–Ne, 632.8 nm, >3.0 mW |
| Auxiliary Laser | Semiconductor, 650 nm, >2.0 mW |
| Ultrasonic Dispersion | 40 kHz, 50 W |
| Stirring Speed | 0–3000 rpm (adjustable) |
| Circulation Flow Rate | 30 L/min |
| Sample Cell Volume | 1000 mL |
| Auto-Alignment System | Quadruple Hybrid Stepper Motor Drive, <1 µm positioning resolution |
| Dimensions | 1040 × 440 × 540 mm |
| Weight | 58 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Model | JK-JG9000 |
| Price | USD 22,500 (FOB Beijing) |
| Dispersion Method | Wet Dispersion |
| Measurement Principle | Dynamic Light Scattering (DLS) |
| Measuring Range | 1–10,000 nm |
| Accuracy | <1% (D50, NIST-traceable standard reference material) |
| Repeatability | <1% (D50, same sample, 3 runs) |
| Laser Source | Fiber-coupled semiconductor laser, λ = 532 nm, lifetime >25,000 h |
| Detector | Hamamatsu high-sensitivity photomultiplier tube (PMT) |
| Scattering Angle | 90° |
| Sample Cell Volume | 4 mL |
| Temperature Control Range | 5–40 °C (±0.1 °C stability) |
| Test Duration | <5 min per run |
| Dimensions | 480 × 270 × 170 mm |
| Weight | 12 kg |
| Brand | Kyocera |
|---|---|
| Origin | Beijing, China |
| Model | JL-9100 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.001–3500 µm |
| Repeatability | >1% |
| Measurement Time | 10 seconds |
| Optical Principle | Laser Diffraction |
| Number of Size Channels | 32 |
| Sample Concentration Range | 0.002–0.2 vol% |
| Data Output | D10, D50, D90, Mode Diameter, Number/Volume/Weight-Average Diameters, Specific Surface Area, Histograms, Cumulative Curves, Fitting Accuracy |
| Brand | Lanjing |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1 µm – 360 µm |
| Repeatability | Better than ±0.5% (NIST-traceable latex standard) |
| Optical Principle | Laser Diffraction with Full Mie Scattering Theory |
| Lens Aperture | Ø110 mm Fourier Transform Coated Lens |
| Laser Source | Imported High-Power Fiber-Coupled Semiconductor Laser, 635 nm |
| Detector Array | Uniform Cross-Distributed & Area-Compensated Multi-Axis Photodiode Array |
| Obscuration Range | 3% – 90% |
| Data Acquisition | 16-bit ADC, 200 kps Sampling Rate |
| Power Supply | External DC Adapter (No Internal AC Mains) |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ParticleMaster Inspex |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Imaging Analyzer |
| Measurement Range | 10–5000 µm |
| Repeatability | ±1% (relative) |
| Measurement Speed | Transient imaging at 25–50 Hz frame rate |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | ParticleMaster-IMI |
| Price Range | USD 105,000 – 132,000 (FOB Hamburg) |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 5 µm – 3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | 10–15 seconds per acquisition |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ParticleMaster-Shadow |
| Dispersion Method | Dry & Wet |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 s |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SprayMaster-Geometry |
| Dispersion Method | Dry & Wet |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 seconds per acquisition |
| Optical Configuration | Backlighting, Light Sheet Imaging (Radial & Axial Cuts) |
| Software | Spray Geometry v5.x |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SprayMaster inspex |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 6–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 s |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | SprayMaster |
| Dispersion Method | Dry & Wet |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% |
| Measurement Time | 10–15 s |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SprayMaster SLIPI |
| Pricing Range | USD 105,000 – 132,000 (FOB Hamburg) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Planar Imaging System |
| Measurement Range | 5–3500 µm |
| Repeatability | <1% (RSD, N≥10, monodisperse PSL standards) |
| Measurement Time per Frame Sequence | 10–15 s |
| Core Technology | Structured Laser Illumination Planar Imaging (SLIPI) |
| Primary Detection Modes | Mie Scattering & Laser-Induced Fluorescence (LIF) |
| Optical Configuration | Synchronized Pulsed Nd:YAG Laser (532 nm or 266 nm), High-Speed CMOS Camera (≥1 MP, ≥10 kHz full-frame), Motorized SLIPI Grating Module, Precision Translation Stages |
| Brand | LINKOPTIK |
|---|---|
| Origin | Guangdong, China |
| Model | LT3600 |
| Dispersion Method | Dry & Wet |
| Measurement Range | 0.015–3600 µm |
| Repeatability | <0.5% |
| Measurement Time | 10 s |
| Optical Principle | Laser Diffraction (Mie Theory & Fraunhofer Approximation) |
| Laser Source | 638 nm, 20 mW Solid-State Laser with Active Temperature Stabilization |
| Detection Angle | Full-Angle Grating-Based Array with Blind-Spot-Free Coverage |
| Data Acquisition Rate | 20,000 Hz |
| Alignment System | Intelligent Auto-Alignment |
| Spatial Filtering | Polarization-Based Non-Pinhole Filter |
| Compliance | ISO 13320 |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mastersizer 2000 |
| Price | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 10 nm – 3 µm |
| Repeatability | <1% RSD |
| Analysis Time | ≤10 minutes |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Mastersizer 3000 |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Mastersizer 3000+ |
| Dispersion Method | Dry and Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 s |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Model | Mastersizer 3000+ |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.01–3500 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 s |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | <1% RSD |
| Measurement Time | <10 seconds per analysis |
| Dispersion Method | Dry and Wet Dispersion |
| Data Acquisition Rate | 10 kHz |
| Laser Source | Stabilized He-Ne Laser (632.8 nm) |
| Brand | Malvern Panalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Spraytec |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5 µm @ 150 mm path length |
| Repeatability | Dv50 better than ±1% COV (NIST-traceable latex standards) |
| Measurement Duration | Fast Mode: 30 seconds |
| Continuous Mode | up to 60 minutes |
| Brand | Micromeritics |
|---|---|
| Origin | USA |
| Model | 5390 |
| Principle | Electrical Sensing Zone (Coulter Principle) |
| Size Range | 0.4–1200 µm (20:1 to 30:1 dynamic range per orifice) |
| Concentration Range | 1–1000 ppm (v/v) |
| Sensing Rate | 1–5,000 particles/sec |
| Analysis Time | 10–100 sec (as low as 1 sec) |
| Repeatability | ±1% (n=10, same sample) |
| Reproducibility | ±1.5% (inter-instrument) |
| Electrolyte Compatibility | Aqueous, organic, or solvating organic media |
| Regulatory Compliance | FDA 21 CFR Part 11 compliant software |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | AEROTRAC II |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.5–2,000 µm |
| Repeatability | ≤1% |
| Measurement Time | 10–15 seconds |
| Optical Principle | Static Laser Diffraction with Full-Range Mie Theory Processing |
| Laser Source | Semiconductor Laser |
| Auto-Focusing | Yes |
| Trigger Mode | Automatic Pulse Detection |
| Software Platform | Windows-Compatible Analysis Suite |
| Optional Accessories | PD-10S Dry Spray Module, SC-13 Wet Dispersion Unit, MB-600 Motorized Translation Stage |
| Compliance | Designed for ASTM E799, ISO 13320, and USP <429> alignment |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | S3500 Series |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range (Laser Diffraction) | 0.01–2,800 µm |
| Image Analysis Range | 0.75–2,000 µm |
| Repeatability | <1% |
| Measurement Time (Laser Diffraction) | 10–30 s |
| Measurement Time (Dynamic Image Analysis) | ~60 s |
| Light Source | Patented Triple-Solid-State Laser (Laser Diffraction) / High-Intensity Stroboscopic LED (Image Analysis) |
| Detection Angle Range | 0.02°–163° |
| Detector Array | 151 logarithmically spaced silicon photodiodes |
| Image Sensor | 5 MP, 2456 × 2058 resolution, 15 fps (optional high-speed camera available) |
| Software Compliance | Fully compliant with FDA 21 CFR Part 11 (audit trail, electronic signatures, data integrity controls) |
| Brand | Microtrac |
|---|---|
| Origin | Germany |
| Model | SYNC |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Diffraction + Dynamic Image Analysis Hybrid System |
| Measurement Range | 0.01–4000 µm |
| Repeatability | <1% |
| Measurement Time | 10–30 s |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 365-10 |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.34–500 µm |
| Data Storage | 128 MB Flash Memory (≥40,000 samples) |
| Battery Life | Up to 6 hours |
| Dimensions (H×D×W) | 17.7 × 29 × 44.3 cm |
| Weight | 7.5 kg |
| Ultrasonic Probe | 25 W, 40 kHz |
| Compliance | ISO 13320-1 |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | DP-02 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–1500 µm |
| Repeatability | <3% |
| Measurement Time | 1–2 minutes |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | LS-909 |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.02–3000 µm (wet), 0.1–3000 µm (dry) |
| Repeatability | <0.5% (D50 standard deviation) |
| Measurement Time | 1–2 minutes |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic Instrument |
| Model | LS-909 II |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.02–3000 μm (wet method, sample-dependent) |
| Repeatability | ≤ 0.5% (D50 deviation of certified reference material) |
| Measurement Time | 1–2 minutes per sample (including system preparation and cleaning) |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | LS-909E |
| Pricing | Upon Request |
| Dispersion Method | Dry Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–3000 µm |
| Repeatability | <0.5% |
| Measurement Time | 1–2 min |
| Measurement Principle | Full-Range Mie Scattering Theory |
| Sample Introduction | Automated Dry Feeding |
| Optical Source | Imported He-Ne Laser (λ = 632.8 nm, Power >2.0 mW) |
| Detector Channels | 87 (Frontal, Sideward, Large-Angle, Multi-Backward) |
| ADC Resolution | 18-bit |
| Sampling Rate | 10 kHz |
| Alignment System | Intelligent Auto-Alignment (Precision: ±0.2 µm) |
| Environmental Operating Range | 5–35 °C, RH <85% |
| Power Requirements | 200–240 V AC, 50 Hz (Host: 60 W |
| Dispersion System | 2000 W) |
| Dimensions (L×W×H) | 1320 × 340 × 360 mm (Host) |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Laboratory Wet-Dispersion Laser Diffraction Particle Size Analyzer |
| Measurement Range | 0.1–750 µm |
| Repeatability | <1% (D50 deviation against certified reference material) |
| Measurement Time | 1–2 minutes |
| Dispersion Method | Wet Dispersion |
| Number of Independent Detection Channels | 49 |
| Light Source | He-Ne laser, 2.0 mW output power, wavelength 632.8 nm |
| Sampling Frequency | 1 kHz |
| Operating Environment | 5–35 °C, RH <85% |
| Dimensions (L×W×H) | 838 × 265 × 295 mm (main unit) |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | PIP8.1 |
| Price | Upon Request |
| Measurement Range | 0.5–3000 µm |
| Repeatability Error | <3% |
| Output Data | Particle size distribution table & curve, D10/D50/D90, specific surface area, aspect ratio statistics, PPC (Particle Profile Classification), equivalent diameter based on area-equivalent circle and minimum bounding rectangle short axis |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Region Category | Domestic (China) |
| Model | PIP9.1 |
| Pricing | Available Upon Request |
| Measurement Principle | Digital Microscopy-Based Image Analysis |
| Test Range | 0.5–3000 µm |
| Repeatability Error | <3% |
| Output Data | Particle Size Distribution Table & Curve (by Equivalent Area Circle, Equivalent Short Diameter, etc.), Roundness Distribution Table & Curve, D10/D50/D90, Specific Surface Area (calculated), Mean Roundness, Roundness Range, Segment-Averaged Roundness, Representative Single-Particle Images |
| Core Hardware | Olympus Biological Microscope (Japan), 1.3 MP CMOS Sensor, USB 2.0 Interface |
| Key Automation | Auto-Focus, Auto-Field Scanning, Auto-Illumination Adjustment |
| Compliance Context | Aligns with GB/T 6408–2008 (Diamond Micropowder Standard), Supports GLP Documentation Workflow |