| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Topsizer |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.02–2000 µm (wet), 0.1–2000 µm (dry) |
| Repeatability | ≤0.5% (D50 of standard reference material) |
| Measurement Time | ≤10 s (typical) |
| Optical Principle | Full-range Mie scattering theory |
| Detector Channels | 98-channel 3D detection system (forward, side, large-angle, and backward scattering) |
| Scattering Angle Range | 0.016°–140° |
| Dual Light Sources | He-Ne laser (632.8 nm) + blue semiconductor laser (466 nm) |
| Laser Stability | Power fluctuation <0.5%, polarization ratio >500:1, TEM₀₀ mode >95% |
| Optical Platform | Monolithic high-precision aluminum alloy base |
| Optical Design | Sealed linear optical path with post-Fourier single-lens transformation |
| Fourier Lens Focal Length | Extended for enhanced large-particle sensitivity |
| Software Compliance | Fully compliant with FDA 21 CFR Part 11 and GMP Annex 11 requirements for computerized systems (user roles, audit trail, electronic signatures, data integrity) |
| Brand | OMEC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Topsizer Plus |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.01–3600 µm (wet), 0.1–3600 µm (dry) |
| Repeatability | ≤0.5% RSD (D50 of standard reference material) |
| Measurement Time | ≤10 seconds per analysis |
| Brand | OMECC |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | LS-609 |
| Pricing | Upon Request |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 0.1–1000 µm |
| Repeatability | <1% (D50 deviation of certified reference material) |
| Measurement Time | 1–2 minutes |
| Light Source | Imported He-Ne laser, λ = 632.8 nm, output power >2.0 mW |
| Detection Channels | 49 independent photodetectors |
| Scanning Frequency | 1 kHz |
| Alignment Accuracy | ±0.5 µm (intelligent auto-alignment) |
| Environmental Operating Conditions | 5–35 °C, RH <85% |
| Data Output | Particle size distribution table & curve, D10/D50/D90, specific surface area, span, etc. |
| Dimensions (L×W×H) | 838×265×295 mm (main unit) |
| Brand | Otsuka |
|---|---|
| Origin | Japan |
| Model | ELSZ-2000 |
| Dispersion Method | Dry & Wet |
| Instrument Type | Laboratory Laser Particle Analyzer |
| Measurement Range | 0.1 nm – 10 µm |
| Repeatability | <5% |
| Measurement Time | 3 min |
| Zeta Potential Range | ±200 mV |
| Temperature Control | 0–90 °C (0.1 °C resolution) |
| Detection Principle | Electrophoretic Light Scattering (ELS), Dynamic Light Scattering (DLS), Static Light Scattering (SLS) |
| Laser Sources | Dual semiconductor lasers (660 nm, 30 mW & 70 mW) |
| Detector | High-sensitivity APD |
| Sample Compatibility | Liquid suspensions, planar solid surfaces (15 mm × 35 mm), high-concentration dispersions |
| Molecular Weight Range | 360 – 20,000,000 Da (Mw) |
| pH Titration Capability | 1–13, 0.1 µL resolution, triple independent syringe system |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ParticleMaster inspex |
| Dispersion Method | Dry & Wet |
| Measurement Range | >5 µm |
| Repeatability | <1% |
| Measurement Time | 30–60 s |
| Compliance | IP54 |
| Light Source | LED (Eye-Safe) |
| Calibration | Factory-Preconfigured Particle Size & Depth-of-Field Calibration |
| Installation | Fixed-Mount Integrated Probe with Coaxial Illumination |
| Brand | PULL |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | PS8011 |
| Pricing | Upon Request |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 0.01–3500 µm |
| Repeatability | ±1% RSD |
| Measurement Time | ≤10 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | DPC-1511 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1–500 µm |
| Repeatability | <1% |
| Measurement Time | 60 sec |
| Detection Principle | Optical Diffraction & Scattering / Laser Flow Imaging |
| Compliance | ISO 13320, ISO 13321 |
| Sample Throughput | One sample per ≤2 min |
| Software Interface | Bilingual (English/Chinese), Windows-compatible |
| Reporting | D3, D10, D25, D50, D75, D80, D90, D97, D100, Span, Specific Surface Area, Aspect Ratio, Circularity Distribution |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513 |
| Origin | Shaanxi, China |
| Instrument Type | Laboratory Laser Diffraction & Flow Imaging Hybrid Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | <5% (D50) |
| Measurement Time | ≤30 s per sample |
| Detection Principle | Laser Diffraction (ISO 13320 compliant) + Hydrodynamic Focusing Flow Imaging (ISO 13321 compatible) |
| Sample Introduction | Static cuvette & recirculating wet dispersion unit |
| Software Platform | Windows-native, bilingual (EN/CN), 20 report templates |
| Compliance | SY/T 5329–2012, Q/SY 01004–2016, SY/T 6596–2016, SY/T 5523–2016 |
| Power Supply | AC 220 V ±10%, 50 Hz, 300 W |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model | DPC-1513-a |
| Price | USD 39,200 (approx.) |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 1% |
| Measurement Time | 30–60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Model | DPC-1513-b |
| Origin | Shaanxi, China |
| Dispersion Method | Dry & Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1 nm – 2000 µm |
| Repeatability | < 5% |
| Measurement Time | 30–60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OPC |
| Price | ¥58,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 1–150 µm |
| Repeatability | 1% |
| Measurement Time | 10 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | OPC-2300 |
| Price | ¥98,000 |
| Dispersion Method | Dry/Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 2–750 µm |
| Repeatability | ±5% |
| Measurement Time | 0.01 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Manufacturer |
| Regional Classification | Domestic |
| Model | OPCI Series |
| Price | ¥58,000 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Size Analyzer |
| Measurement Range | 1–150 µm |
| Repeatability | ±1% |
| Measurement Time | 10 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Dispersion Method | Dry & Wet Dispersion |
| Measurement Range | 1–450 µm |
| Repeatability | <5% |
| Measurement Time | 20 s |
| Brand | PULUODY |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | PLD-601 |
| Price Range | USD 55,000–69,000 (FOB UK) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.1–800 µm |
| Repeatability | ≥99% |
| Measurement Time | 10–60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-601 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Light Obscuration (LO) Particle Counter |
| Measurement Range | 1–500 µm |
| Repeatability | 1000 particles/mL (2.5% coincidence error) |
| Measurement Time | 60 seconds |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PLD-601 |
| Price | USD 35,200 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Benchtop Laboratory Laser Particle Counter |
| Measurement Range | 1–500 µm (0.03–3000 µm available upon configuration) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Measurement Time | ≤60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PLD-601-X |
| Price | USD 26,500 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Light Obscuration Particle Counter |
| Measurement Range | 1–450 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 5–60 seconds per sample |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PLD-MPCS2.0 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Microscopy-Based Particle Counting System |
| Measurement Range | 1 µm – 500 µm |
| Repeatability | < 5% (excluding sample preparation variability) |
| Analysis Time | 60 seconds |
| Magnification | 40× – 1000× |
| Resolution | 0.1 µm |
| Microscope Accuracy | ±0.02 µm |
| CCD Camera | 3 MP |
| Calibration Standard | NIST-traceable stage micrometer (0.1 µm division) |
| Software Environment | Windows OS (XP through 11) |
| Interface | RS-232 or USB |
| Particle Recognition Accuracy | >95% (per ChP 2020), <10% misclassification (per USP <788> & ISO 21501-1) |
| Overlap Tolerance | ≤5% at 10,000 particles/mL |
| Image Stitching | Fully automated, seam-free membrane scanning |
| Segmentation Speed | <1 second per field |
| Segmentation Success Rate | >93% |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | PMT-2 |
| Price | USD 67,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Online Laser Particle Counter |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2020 Vol. IV, GB 8368 |
| Sample Flow Control | Precision Metering Plunger Pump + Electromagnetic Flow Regulation |
| Counting Resolution | 0.1 µm (c) minimum detectable threshold |
| Coincidence Limit | ≤2.5% error at 1000 particles/mL |
| Analog Output | 4–20 mA |
| Data Interface | IPAD-compatible wireless acquisition system |
| Operating Voltage | 100–265 VAC, 50–60 Hz |
| Display | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Key | Brand: PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Laboratory Laser Particle Counter |
| Dispersion Method | Wet Dispersion |
| Measurement Range | 0.1–1.0 µm |
| Repeatability | ±3% |
| Measurement Time | 60 s |
| Sensor Generation | 8th-Gen Dual-Laser Narrow-Beam Detector |
| Calibration Standards | ISO 21501-2, USP <788>, EP 2.9.19, ChP 2020, GB 8368 |
| Data Output | Particles/mL & ISO 4406 / NAS 1638 Contamination Codes |
| Sampling Accuracy | <±1% |
| Counting Accuracy | ±3% typical |
| Coincidence Limit | 10,000 particles/mL (2.5% coincidence error) |
| Analog Output | 4–20 mA with customizable alarm threshold |
| Operating Interface | Color LCD touchscreen + optional wireless keyboard/mouse |
| Software | PULUODY V8.3 Integrated Analysis Suite (PC & embedded) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | PMT-2-H |
| Price | USD 72,800 (approx.) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 0.5–5.0 µm |
| Repeatability | ≤3% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | ISO 21501-4, USP <788>, EP 2.9.19, ChP 2015/2020, GB 8368 |
| Flow Control | Precision Metering Plunger Pump + Ultra-Stable Electromagnetic Flow Regulation |
| Sample Interface | 4–20 mA Analog Output |
| Data Acquisition | iPad-Compatible Wireless Interface |
| Operating Interface | Color LCD Touchscreen + Optional Wireless Keyboard/Mouse |
| Reporting Units | Particles/mL & ISO 4406 / NAS 1638 Contamination Codes |
| Voltage Input | 100–265 VAC, 50–60 Hz |
| Counting Accuracy | <±1% volumetric error |
| coincidence limit | 1000 particles/mL (≤2.5% coincidence error) |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | PMT-2-K |
| Price | USD 34,800 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Counter |
| Measurement Range | 2–750 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | 60 s per sample |
| Sensor Generation | 8th-Generation Dual-Laser Narrow-Beam Detection |
| Calibration Standards | JJG 1061, ISO 21501-4, NIST-Traceable Latex Spheres |
| Software Version | V8.3 Integrated Analysis & Calibration Suite (PC + Touchscreen) |
| Sampling Accuracy | <±1% |
| Size Accuracy | <±3% (typ.) |
| Coincidence Limit | 1000 particles/mL (2.5% coincidence error) |
| Output Interface | 4–20 mA analog output with customizable over-limit alarm |
| Reporting | Particles/mL and ISO 4406 / NAS 1638 contamination codes |
| Power Input | 100–265 VAC, 50–60 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PMT-2-S |
| Price | USD 53,000 (FOB) |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser-Based Particle Counter |
| Measurement Range | 1–450 µm |
| Repeatability | ≤5% RSD |
| Measurement Time | ≤60 s |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PSD-PF100-1A-0.5 |
| Dimensions | 360 × 450 × 580 mm |
| Cleanliness Classes | ISO Class 4 (10 particles/ft³ ≥0.1 µm), ISO Class 5 (100 particles/ft³ ≥0.5 µm) |
| Airflow Velocity | 0.25 m/s |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Lighting | Fluorescent Lamp |
| Sterilization | UV-C Germicidal Lamp |
| Optional Accessories | Pneumatic Rotary Stage (bidirectional), High-Purity Nitrogen Inlet with Particle Filter, Adjustable Gooseneck Nozzle |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | PSD-PF10A-0.5 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Size Analyzer |
| Cleanroom Classification | ISO Class 4 (Equivalent to Federal Standard 209E Class 10) |
| Repeatability | ±1% |
| Measurement Time | 15 s |
| Airflow Velocity Range | 0.25–0.6 m/s (adjustable) |
| Vibration Amplitude | ≤3 µm |
| Noise Level | ≤67 dB(A) |
| UV Sterilization Cycle | 15 min for microbial reduction to sterile conditions |
| Operating Temperature | 10–30 °C |
| Relative Humidity | ≤75% RH |
| Power Supply | AC 220 V ±10%, 50 Hz ±1 Hz |
| Brand | PULUODY |
|---|---|
| Origin | Shaanxi, China |
| Model | PST-890 |
| Dispersion Method | Wet Dispersion |
| Instrument Type | Laboratory Laser Particle Counter |
| Measurement Range | 1–500 µm (0.03–3000 µm optional) |
| Repeatability | ≤2.5% coincidence error at 1000 particles/mL |
| Measurement Time | 60 seconds |
| Origin | Shandong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | RISE 2202 |
| Pricing | Available Upon Request |
| Measurement Range | 0.1–600 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, consecutive runs) |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 1000 × 330 × 320 mm |
| Weight | 39 kg |
| Laser Source | He-Ne gas laser, λ = 632.8 nm, linewidth < 0.002 nm, lifetime > 25,000 h |
| Detector Array | Non-uniform, cross-dimensional 3D扇-shaped matrix (patent-pending geometry), max detection angle: 90° |
| Dispersion System | Integrated 400 mL wet dispersion cell with 100 W ultrasonic probe, programmable sonication time, adjustable stirrer speed & circulation pump flow rate |
| Software | PADMAS v5.2 (Particle Diameter Measure & Analysis System), compliant with GLP audit trail requirements, supports FDA 21 CFR Part 11 optional electronic signature module |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | RISE-2026 |
| Pricing | Upon Request |
| Measurement Range (Wet) | 0.05–800 µm |
| Measurement Range (Dry) | 0.1–800 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, repeated measurements) |
| Electrical Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 950 × 330 × 300 mm |
| Weight | 50 kg |
| Laser Source | He–Ne gas laser, λ = 632.8 nm, lifetime >25,000 h |
| Maximum Detection Angle | 105° |
| Detector Array | Non-uniform cross-three-dimensional扇-shaped matrix (translated as “non-uniform crossed 3D sectoral matrix”) |
| Optical Design | Single-range convergent optical path, Fourier lens-free alignment |
| Standard Grading | 130 size classes default (0.02–2000 µm), fully customizable from Class 1 to 130 |
| Software | PADMAS v5.x (Particle Diameter Measure & Analysis System) |
| Data Export | CSV, Excel (.xlsx), PDF, PNG/JPEG images |
| Compliance | Designed per Q/01RZ01–2004 enterprise standard |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Regional Origin | Domestic (China) |
| Model | RISE-2028 |
| Pricing | Available Upon Request |
| Measurement Range (Wet) | 0.02–1200 µm |
| Measurement Range (Dry) | 0.1–1200 µm |
| Accuracy Error | < ±1% (D50, NIST-traceable standard reference materials) |
| Repeatability | < ±1% (D50, same sample, repeated measurements) |
| Power Supply | AC 220 V ±10%, 50 Hz, 200 W |
| Dimensions (L×W×H) | 950 × 330 × 300 mm |
| Weight | 50 kg |
| Laser Source | He-Ne gas laser, λ = 632.8 nm, lifetime >25,000 h |
| Maximum Detection Angle | 135° |
| Detector Array | Non-uniform cross-three-dimensional扇-shaped matrix (translated as “non-uniform crossed 3D sectoral matrix”) |
| Default Size Classes | 130 channels (0.02–2000 µm), fully customizable from 1–130 channels |
| Data Output | Excel-compatible CSV, PDF, image (PNG/JPEG), printable reports with header/footer customization |
| Software | PADMAS v5.x (Particle Diameter Measure & Analysis System) |