BrandLihero
ModelLFAF-2016
Detection PrincipleHydride Generation–Atomic Fluorescence Spectrometry (HG-AFS)
Measurement ElementsAs, Se, Hg, Cd, Zn, Bi, Te, Sb, Ge, Pb (≥10 elements)
ConfigurationMulti-channel simultaneous analysis
AtomizerShielded low-temperature quartz furnace atomizer
Light SourceElement-specific coded hollow cathode lamps with automatic recognition and lifetime monitoring
Gas ControlDigital pressure-sensing argon flow regulation with intelligent gas-saving module
System DiagnosticsPower-on self-test, real-time fault diagnosis, and audible/visual alarm
ComplianceDesigned to support ISO 17294-2, EPA Method 1631/200.9, and GB/T 5750.6–2023 workflows
Installation TypeRack-mounted online analyzer for continuous or scheduled water intake
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFWCS-2008
OriginHunan, China
Instrument TypeOnline Monitor
Output Signals4–20 mA / RS-485 / RS-232
Probe CleaningAutomatic brush (turbidity), programmable electrode cleaning interface
Diagnostic CapabilitiesElectrode aging, membrane fouling/rupture/open-circuit detection
Insulation Resistance≥20 MΩ (power line to chassis)
Conductivity TechnologyFour-electrode sensor
User InterfaceGraphical LCD with intuitive calibration workflow
ComplianceDesigned for continuous environmental monitoring per Chinese HJ/T 96–2003 and ISO 7027 (turbidity), ISO 5814 (DO), ISO 7888 (conductivity), and ASTM D1293 (pH)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFS-2002 (NO₂)
Measurement PrincipleN-(1-Naphthyl)ethylenediamine Dihydrochloride Spectrophotometry (ISO 6775, APHA 4500-NO₂⁻ B)
Wavelength540 nm ± 2 nm
Detection Range0–1.0 mg/L NO₂⁻-N (extendable to 0–5.0 mg/L with dilution)
Detection Limit≤ 0.005 mg/L NO₂⁻-N
Accuracy±5% of reading or ±0.01 mg/L (whichever is greater)
RepeatabilityRSD ≤ 3%
Sample Volume10–50 mL
DigestionHigh-temperature (120°C), high-pressure sealed digestion module
Turbidity & Color CompensationReal-time dual-wavelength optical correction
Calibration ModesZero check, span check, standard verification, curve auto-calibration, spike recovery test
Data LoggingInternal SD card + RS485/Modbus RTU + optional 4G/ETH remote upload
Operating SystemEmbedded Linux (real-time kernel)
Power Supply220 VAC ±10%, 50 Hz
IP RatingIP65 (enclosure)
ComplianceGB/T 32203–2015, HJ 537–2009, ISO 6775:1984, APHA Standard Methods 4500-NO₂⁻ B
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFS-2002 (CODMn)
TypeOnline Analyzer
Detection PrinciplePotassium Permanganate Oxidation Titration (Acidic & Alkaline Methods)
Endpoint DetectionPhotometric & Potentiometric Titration
Chloride Interference CompensationAutomatic Method Switching (Acidic vs. Alkaline)
Self-DiagnosisIntegrated Sensor Health Monitoring, Optical Path Auto-Balancing, Reagent Level & Sample Flow Monitoring
Calibration & QA/QCAutomated Zero/Span/Standard Verification, Curve Auto-Calibration, Spike Recovery Test
Compliance SupportDesigned for ISO 8467, ASTM D1253, and GB/T 5750.7–2006 alignment
Remote OperationModbus TCP, RS485, and Optional OPC UA Integration
Operating SystemEmbedded Real-Time OS
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFTOX-B2010
TypePortable Toxicity Analyzer
Measurement PrincipleBioluminescent Bacterial Assay (ISO 11348-3)
MicroorganismFreeze-dried *Aliivibrio fischeri* (formerly *Vibrio fischeri*)
Reconstitution Time<5 min
Shelf Life (lyophilized)≥6 months at ≤−20 °C
Working Stability (reconstituted)7–10 days at 2–8 °C
Detection RangeEC50 from 0.1% to 100% sample dilution (equivalent to broad-spectrum toxicity index)
ComplianceISO 11348-3:2022, DIN 38412-30, EPA 600/R-95/125
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFS-2002(TP)
TypeOnline Analyzer
Measurement PrinciplePeroxysulfate Digestion + Ascorbic Acid-Molybdate Colorimetry
Detection MethodPhotometric Absorption at 700 nm
ComplianceHJ/T 212–2017, GB 11893–1989
Power Supply Insulation Resistance≥20 MΩ
Communication InterfacesRS-232 / RS-485 / RJ-45
Operating SystemEmbedded Linux
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
OriginHunan, China
ModelLFWGC-2012
Instrument TypeOnline Water Quality Analyzer for Volatile Organic Compounds (VOCs)
Detection PrincipleGas Chromatography with Purge-and-Trap Preconcentration
DetectorsFID (Field-Deployable Flame Ionization Detector), ECD
Target Analytes>30 VOCs including halogenated hydrocarbons, BTEX, aldehydes
Sample Volume10 mL per analysis
CalibrationIntegrated Automated Calibration Module
ComplianceDesigned to meet GB 3838–2002 (China Surface Water Environmental Quality Standards), EPA Method 524.2 & 8260D equivalency
Remote ControlYes
Data LoggingFull Process Audit Trail with Event Timestamping
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFS-2002 (LAS)
Measurement PrincipleMethylene Blue Active Substances (MBAS) Spectrophotometric Method
Wavelength650 nm ± 2 nm
Optical Path10 mm quartz cuvette or flow cell
Detection Range0.05–2.00 mg/L LAS (as MBAS)
Resolution0.01 mg/L
Repeatability≤ ±2.0% RSD
CalibrationAutomatic 2-point calibration with standard reference solutions
CleaningProgrammable automatic rinsing cycle using deionized water
Communication InterfacesRS-232, RS-458, RJ-45 Ethernet
Operating SystemReal-time embedded Linux
ComplianceGB/T 7494–1987, ISO 7875-2:1987, ASTM D2330–18
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFS-2002(TCl)
TypeOnline Analyzer
Measurement PrincipleDPD Colorimetric Spectrophotometry at 520 nm
Sample Turnaround Time≤20 min per analysis
Reagent Switching CapabilityResidual Chlorine / Total Chlorine / Chlorine Dioxide
Calibration ModesZero Check, Span Check, Standard Calibration, Curve Auto-Standardization, Spike Recovery Test
Self-DiagnosticsComponent Failure, Over-Range, Abnormal Data, Reagent/Water Depletion Alarms
Maintenance FunctionsAutomatic Optical Path Balancing, Scheduled Cleaning, Auto-Calibration, Auto-Range Switching
Compliance SupportDesigned for ASTM D1253, ISO 7393-2, EPA Method 334.0, and GB/T 5750.11–2023 (China National Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
OriginHunan, China
ModelLFFColi-2016
Detection PrincipleEnzyme-Substrate Method (Defined-Substrate Technology)
Detection Limit1 MPN/100 mL
Analysis Time4–18 h
Sample TypesDrinking Water, Raw Water, Surface Water, Groundwater, Tap Water, Healthcare Facility Water
Operating ModeStandalone Manual / Standalone Automatic / PC-Connected Automatic
Temperature ControlIndependent恒温培养模块 (Multi-zone thermostatic incubation system)
Turbidity CorrectionBuilt-in optical turbidity compensation
MaintenanceAutomated line disinfection and rinsing cycle
CalibrationField-deployable NIST-traceable calibration module compliant with GB/T 5750.12–2023 (Standard Methods for Examination of Water and Wastewater – Microbiological Parameters)
Data OutputRS485/Modbus RTU, Ethernet, optional 4G/LTE telemetry
ComplianceDesigned to support ISO 9308-1:2014, EPA Method 1604, and GB/T 5750.12–2023 microbiological validation requirements
Remote MonitoringWeb-based dashboard with audit trail and user-access control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLihero
ModelLFS-2002(TN)
Measurement PrincipleHigh-Temperature Alkaline Persulfate Oxidation + UV Spectrophotometry (220 nm & 275 nm)
Detection Range0.05–100 mg/L TN (typical, configurable)
Detection MethodA = A₂₂₀ₙₘ − 2 × A₂₇₅ₙₘ
消解条件120–124 °C, ≥0.11 MPa, 30 min
Optical SystemDual-Wavelength UV Photometer with Auto-Balanced Optical Path
Calibration ModesZero Check, Span Check, Standard Calibration, Curve Auto-Standardization, Spike Recovery Test
Compliance SupportASTM D5176, ISO 11908, HJ 636-2012, EPA 351.2 (adapted), GLP/GMP-ready data logging
Remote InterfaceModbus TCP/IP, RS485, Optional 4G/LTE Data Upload
Operating SystemEmbedded Linux Real-Time OS
Self-DiagnosisIntegrated Sensor Health Monitoring, Reagent Level Sensing, Optical Path Stability Verification, Fault Logging & Cloud Upload