Mass Spectrometry Components
Filter
Showing 1–30 of 45 results
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | puriFlash® Active Splitter |
| Pricing | Available Upon Request |
| Brand | Agela |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | ACQ-06 |
| Pricing | Available Upon Request |
| Brand | Aliben |
|---|---|
| Origin | Sichuan, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | PEC.A02 |
| Price Range | USD 11,200 – 21,000 |
| Brand | ASPEC |
|---|---|
| Origin | USA |
| Model | PST Nano-Column Heaters |
| Temperature Range | Ambient to 100°C (for heating variants) / –5°C to 60°C (PST-CHC-LT+), ±0.2°C stability |
| Heating Configurations | Butterfly-style (PST-BPH-15, PST-BPH-20), Sleeve-type (PST-CH-xxU, PST-CH-30-50U), Partial-column (PST-BCH-15, PST-BCH-30), Extended-box (PST-CH-LT-20, PST-CH-LT), Cryogenic (PST-CC, PST-CHC-LT+) |
| Compatible Column Formats | PicoFrit®, eFrit®, integrated nanoLC columns (C4, C8, C18), trap columns, emitter tips, and associated capillary tubing and fittings |
| Controller | PST-CHC-RC universal temperature controller with PID regulation and digital display |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ion Source |
| Pricing | Available Upon Request |
| Key | Brand: Bruker |
|---|---|
| Origin | Germany |
| Model | PepSep™ C18 |
| Type | Reversed-phase analytical column for nano/micro-flow LC-MS |
| Packing Material | Surface-modified silica with endcapping |
| Particle Size | 1.6 µm (typical for PepSep™ series) |
| Pore Size | 100 Å |
| Column ID | 75 µm × 25–50 cm (standard configurations) |
| Pressure Rating | ≤1000 bar |
| Compatible With | NanoLC, microLC, and timsTOF platforms (e.g., timsTOF Pro, timsTOF SCP) |
| Surface Chemistry | C18 bonded phase with low silanol activity |
| Batch-to-batch reproducibility | ≤3% RSD in retention time (n=5 injections, standard peptide mix) |
| Brand | CovalX |
|---|---|
| Origin | Switzerland |
| Model | HM4 or Pearl |
| Compatibility | TOF and TOF/TOF Mass Spectrometers (Bruker, Shimadzu, SCIEX) |
| Detection Principle | Dual-Stage Dynode Conversion with High-Voltage Electron Multiplication |
| Mass Range | >2.5 MDa |
| Sensitivity | Sub-nM for Intact Protein Complexes |
| Vacuum Architecture | Integrated High-Vacuum Tube with Electroless Nickel Plating (Patent WO 2009086642) |
| Ion Polarity | Simultaneous Positive/Negative Mode Detection |
| Software | CovalX “ComplexTracer” Data Analysis Suite |
| Brand | Chemlab |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Chemlab (OEM/ODM) |
| Model | DragonMaster (Membrane-Based Wet Desolvation) |
| Type | ICP-MS Desolvation Accessory |
| Compliance | Designed for ISO/IEC 17025-compliant labs, compatible with GLP/GMP workflows requiring audit-trail-capable operation |
| Brand | GERSTEL |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CCD2 |
| Pricing | Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Product Type | Imported |
| Model | A14111-3-1 |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | A13331-18-2 |
| Pricing | Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model Numbers | A13331, A14111 |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Product Type | Imported Mass Spectrometry Component |
| Model | A13331-3-1 |
| Pricing | Available upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer | Hamamatsu Photonics K.K. |
| Product Type | Imported Mass Spectrometry Component |
| Model | A14111-3-3 |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | R13733 |
| Pricing | Available Upon Request |
| Dynode Stages | 18 |
| Dynode Structure | Linear Focused |
| Dynode Material | Al₂O₃ |
| Input Aperture Diameter | 11 mm |
| Operating Voltage | 2500 V |
| Typical Gain | 3.0 × 10⁷ |
| Typical Rise Time | 7.0 ns |
| Anode-to-Other-Dynodes Capacitance | 3.0 pF |
| Anode-to-First-Dynode Voltage | 0 V |
| Anode-to-Last-Dynode Voltage | 0 V |
| Maximum Average Anode Current | 10 µA |
| Required Operating Vacuum | ≤ 1 × 10⁻² Pa |
| Dimensions (L × W × H) | See mechanical drawing in datasheet |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | R4-9 |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | R4146-10 |
| Pricing | Available Upon Request |
| Dynode Stages | 18 |
| Dynode Structure | Linear Focused |
| Dynode Material | Cu-BeO (Copper-Beryllium Oxide) |
| Input Aperture | 8 × 1 mm |
| Operating Voltage | 1800 V (Total Supply) |
| Typical Gain | 1.0 × 10⁷ |
| Rise Time (Typ.) | 3.5 ns |
| Anode-to-Dynode Capacitance | 4.0 pF |
| Anode-to-First-Dynode Voltage | 2500 V |
| Anode-to-Last-Dynode Voltage | 350 V |
| Average Anode Current | 10 µA |
| Required Operating Vacuum | ≤ 1 × 10⁻² Pa |
| Physical Thickness | 6 mm |
| Mounting Configuration | Stackable for Multi-Collector Mass Spectrometry Systems |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | J13550-09D |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | C14051-15 |
| Input Voltage Range | +11 V to +16 V DC |
| Max. Output Voltage | −10 kV |
| Max. Output Current | 0.2 mA |
| Guaranteed Output Range | −2000 V to −10000 V |
| Line Regulation | ±0.1 % (over input voltage variation from +11 V to +16 V) |
| Load Regulation | ±0.1 % |
| Ripple & Noise | ≤0.1 mV RMS |
| Operating Temperature | −10 °C to +60 °C |
| Tempco | ±0.01 %/°C |
| Storage Temperature | −20 °C to +70 °C |
| Storage Humidity | <80 % RH (non-condensing) |
| Dimensions (W × H × D) | 98 mm × 25 mm × 45 mm |
| Weight | 160 g |
| Form Factor | Compact OEM Module |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | L7293 / L13301 |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | F14845-11 |
| Pricing | Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | F14844 |
| Pricing | Available Upon Request |
| Effective Diameter | 14.5 mm |
| Overall Diameter | 32 mm |
| Configuration | Demountable Dual-Stage MCP |
| Electrode Architecture | Grid-Anode Triode Structure |
| Vacuum Interface | Non-Flanged (User-Integrated Mounting) |
| Temporal Response | Fast (Sub-Nanosecond Rise Time) |
| Operating Pressure Range | Up to 1 Pa (Maintains Stable Dark Current vs. High-Vacuum Baseline) |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | F9890-12 |
| Pricing | Available Upon Request |
| MCP Configuration | Dual-stage (2-stage) |
| Effective Active Area | Ø27 mm |
| Overall Diameter | Ø81 mm |
| Geometry | Circular, Removable Mounting Design |
| Application | Time-of-Flight Mass Spectrometry (TOF-MS) Detector Assembly |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | F1094-01 |
| Pricing | Available Upon Request |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | F12396-11 |
| Pricing | Available Upon Request |
| Shape | Rectangular |
| Construction | Demountable Type |
| MCP Stages | Dual (2-Stage) |
| Overall Dimensions | 52 × 72 mm |
| Active Area Diameter | 42 mm |
| Brand | Hamamatsu |
|---|---|
| Origin | Japan |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | F13446-11 |
| Voltage Range | −5 kV to +5 kV |
| Geometry | Circular, Removable |
| MCP Stages | Dual-stage (2-stage) |
| Outer Diameter | 50 mm |
| Active Area Diameter | 27 mm |
| Fast Time Response | Yes |
| Open Area Ratio (OAR) | Standard (optional funnel-type large-OAR variant available) |
| Brand | ESI |
|---|---|
| Origin | USA |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | microFAST Single Cell |
| Price | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MRA-100 |
| Pricing | Upon Request |
| Wetted Materials | Stainless Steel and RPC-8™ |
| Connection | 10-32 External Thread Fittings |
| Flow Path Diameter (Stator Assembly) | 0.71 mm (0.028″) and 0.38 mm (0.015″) |
| Flow Path Volume (Per Port) | Port 1 – 2.96 µL, Port 2 – 3.76 µL, Port 3 – 0.77 µL, Port 4 – 0.46 µL |
| Max Operating Pressure | 6.9 MPa (69 bar, 1000 psi) |
| Dimensions | 19.1 cm × 14.1 cm × 7.8 cm (7.5 in × 5.6 in × 3.1 in) |
| Weight | 2.1 kg (4.6 lb) |
| Control Interface | Digital TTL Signal and RS-232 |
| Brand | Savillex |
|---|---|
| Origin | USA |
| Model | 850-011-100706 |
| Material | Perfluoroalkoxy (PFA) |
| Configuration | Dual-channel nebulizer spray chamber assembly with detachable O-ring sealed end cap, integrated make-up gas port, 6 mm OD nebulizer inlet, PFA drain connector kit, quartz torch, PFA injection tube, support stand, and pre-cleaned components (pre-rinsed in high-purity HNO₃/HF) |
| Compliance | Compatible with Thermo Scientific Element 2 HR-ICP-MS and Neptune MC-ICP-MS platforms |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | France |
| Model | puriFlash® Active Splitter |
| Flow Path Architecture | Active Valve-Based Splitting |
| Split Ratio Control | Software-Defined Switching Frequency |
| Pressure Management | Zero Backpressure Generation |
| Compatibility | Interchim puriFlash® Systems & All Interchim HPLC/UHPLC Columns |
| Detection Integration | Simultaneous UV + MS Trigger Logic |
| Software Control | Intersoft® X Platform (FDA 21 CFR Part 11 Compliant Audit Trail Optional) |