Mass Spectrometry Instruments
Filter
Showing 181–210 of 487 results
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Model | EXPEC 7000 |
| Quotation | Upon Request |
| Deployment Mode | Mobile (Vehicle-Mounted) |
| Mass Range | 2–260 amu |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | LGA Series |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | Mars-400 Plus |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Type | Low Thermal Mass (LTM) GC |
| Mass Range | 15–550 amu |
| Resolution | Unit Mass Resolution |
| Detection Limit | < 1 ppb (for selected VOCs, e.g., benzene, toluene) |
| Scan Speed | 10,000 amu/s |
| Power Supply | Integrated Rechargeable Li-ion Battery |
| Carrier Gas | Built-in Helium or Hydrogen Micro-Gas Cylinder (30–60 min runtime) |
| Weight | < 19 kg |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | Mars-400 Plus |
| Instrument Type | Ion Trap Mass Spectrometer |
| Chromatography Configuration | Low Thermal Mass (LTM) GC |
| Mass Range | 15–550 amu |
| Resolution | Unit Mass Resolution |
| Detection Limit | < 1 ppb (for selected VOCs, e.g., benzene, toluene) |
| Scan Speed | 10,000 amu/s |
| Power Supply | Integrated rechargeable Li-ion battery (≥4 h continuous operation) |
| Carrier Gas | Built-in helium or hydrogen micro-gas cylinder (30 mL, refillable) |
| Weight | < 19 kg (instrument only, without accessories) |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | Mars-400 Portable |
| Mass Analyzer Type | Ion Trap |
| Mass Range | 1–1000 m/z |
| Resolution | 1000–2000 (FWHM at m/z 502) |
| Sensitivity | 300:1 (S/N for 1 pg methyl parathion, full scan) |
| Scan Speed | 15,000 µs per scan |
| GC Technology | Low Thermal Mass (LTM) Gas Chromatography |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Mars-550 |
| Pricing | Available Upon Request |
| Brand | FPI |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Category | Domestic |
| Model | Mars-6100 |
| Mass Range | 10–750 m/z |
| Resolution | 1 amu (unit mass resolution) |
| Sensitivity | ≥150:1 S/N at m/z 272 for 1 pg octafluoronaphthalene (OFN), 1 µL injection |
| Scan Speed | 10,000 amu/s |
| Analyzer Type | 3D Quadrupole Ion Trap |
| GC-MS Configuration | Conventional Capillary GC-Coupled Ion Trap MS |
| Interface | Patented Self-Locking GC-MS Interface |
| Brand | Fulit |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | S900 GC-MSD |
| Pricing | Upon Request |
| GC Configuration | Conventional Capillary GC-MS |
| Brand | Kunyuan Instruments |
|---|---|
| Origin | Tianjin, China |
| Model | Gaia |
| Acceleration Voltage | ±10 kV |
| Sample Carousel Capacity | 21 filament positions (single/dual filament) |
| Mass Analyzer Type | Nier-Johnson geometry |
| Mass Dispersion | 560 mm |
| Magnetic Field Control | Hall-effect sensor with closed-loop feedback |
| Polarity Switching | Computer-controlled for positive/negative ion mode |
| Detector Configuration | Up to 16 Faraday cups + 4-channel discrete-dynode electron multiplier |
| RPQ Energy Filter | Optional |
| Preamp Capacity | Up to 32 units |
| Gain Range | 10¹⁰–10¹³ Ω selectable |
| Data Acquisition | 24-bit synchronized ADC, ppm-level precision |
| Dimensions (L×W×H) | 2160 × 1840 × 1810 mm |
| Power Supply | AC 220 V / 50 Hz, grounding resistance < 2 Ω |
| Cooling | Dedicated 500 W chiller for turbo pumps & magnet |
| Ambient Requirements | 18–24 °C, 40–60 % RH |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Optimass 9500 |
| Instrument Type | Inductively Coupled Plasma Time-of-Flight Mass Spectrometer |
| Mass Resolution (Unit Mass Resolution at m/z = 238) | 2000 |
| Detection Limit | 1–10 ng·L⁻¹ (ppt level, 3–5 s integration time) |
| Sensitivity | Mcps per ppm |
| Mass Range | 1–260 amu (full-spectrum acquisition) |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Optimass 9600 |
| Price Range | USD 420,000 – 700,000 (FOB) |
| Instrument Type | Time-of-Flight Mass Spectrometer (ICP-TOFMS) |
| Mass Resolution (FWHM at 1 amu) | >4000 |
| Detection Limit (in aqueous solution) | <0.1 pg/mL (ppt-level) |
| Sensitivity | >1 × 10⁶ cps per µg/L (Mcps/ppm) |
| Brand | Titan Instruments |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Titan Instruments |
| Type | Domestic |
| Model | GC-IMS 1000 |
| Pricing | Upon Request |
| Brand | Kunyuan Instruments |
|---|---|
| Origin | Tianjin, China |
| Model | Sparkle |
| Cooling | Liquid Nitrogen (Ambient Pressure) |
| Resolution Modes | 400 / 4000 / 10,000 (switchable in <1 s) |
| Detection Limit | Sub-ppb (typical), down to low-ppt (element-dependent) |
| Dynamic Range | 12 decades (Faraday cup + electron multiplier) |
| Sample Throughput | Full-element scan (78 elements) <5 min |
| Depth Resolution | Sub-micrometer |
| Gas Consumption | Ar, ≥99.9995% purity |
| Dimensions | 2160 × 2040 × 1480 mm (L×W×H) |
| Power | AC 220 V / 50 Hz, grounding resistance <2 Ω |
| Cooling | External chiller (500 W) for turbo pumps & magnet |
| Ambient | 18–24 °C, 40–60% RH |
| Brand | Genewish |
|---|---|
| Origin | Zhejiang, China |
| Model | Gene TOF 3100 |
| Mass Analyzer Type | Time-of-Flight (TOF) |
| Application Domain | In Vitro Diagnostic (IVD) Devices & Clinical Molecular Testing |
| Regulatory Classification | Domestic IVD Instrument (China NMPA-compliant design basis) |
| Configuration | Integrated PCR-MS workflow platform with automated sample purification and matrix-assisted laser desorption/ionization (MALDI) source |
| Brand | Grand |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Classification | Domestic (China) |
| Model | Helium-Specific MS |
| Pricing | Available Upon Request |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Domestic (China) |
| Model | Hapline P8800 |
| Instrument Type | Portable GC-MS |
| Power Supply | 220 V AC or internal/external DC battery (≤24 V, ≤30 W) |
| Compliance | HJ 1223–2021, HJ 1227–2021, HJ 1058–2019, Draft HJ Standard for VOCs in Stationary Source Emissions |
| Inlet Technology | Membrane Introduction (MI) |
| Enclosure Rating | IP55 |
| Vacuum System | Non-mechanical (e.g., turbomolecular or diffusion pump-free architecture) |
| Spectrometer Type | Quadrupole Mass Analyzer |
| Library Support | NIST MS Search Database |
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | ZLS-23B / ZLS-24C |
| Minimum Detectable Leak Rate | 2 × 10⁻¹¹ Pa·m³/s |
| Pump Type | Oil-Diffusion Vacuum System |
| Detection Gas | Helium (⁴He⁺) |
| Mass Separation Principle | Magnetic Sector Mass Filter |
| Brand | HEXIN MASS SPECTROMETRY |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | SPAMS 05 Series |
| Pricing | Upon Request |
| Brand | Hiden |
|---|---|
| Origin | Austria |
| Model | HPR20 QIC TMS |
| Mass Range | 1–50 / 100 / 200 / 300 / 500 / 1000 amu |
| Sampling Pressure | 100 mbar–2 bar (standard) |
| Response Time | <150 ms |
| Dynamic Range | 7 decades (pulse-counting detector) |
| Detection Limit | 5 ppb |
| Quantification Range | ppm to 100% |
| Stability | ±0.5% peak height over 24 h |
| Scan Speed | 100 amu/s |
| Measurement Rate | 500 data points/sec |
| Capillary | 0.9 m heated quartz inert capillary (up to 200 °C) |
| Ionization | APSI-MS soft ionization |
| External Analog Outputs | 2 standard, up to 16 optional |
| Brand | Hiden |
|---|---|
| Origin | United Kingdom |
| Model | SIMS Workstation |
| Mass Analyzer Type | Quadrupole |
| Primary Beam Energy | 25 keV Ga⁺ |
| Mass Range | 1000 amu |
| Mass Resolution | 0.5 amu (5% valley between adjacent equal-height peaks) |
| Detection Mode | Pulsed Ion Counting (positive/negative ions) |
| Dynamic Range | 7 decades |
| Spatial Resolution | 50 nm (Ga⁺ beam), 100–150 µm (O₂⁺/Cs⁺ beams) |
| Vacuum System | UHV-compatible, three-stage differential pumping |
| Control Interface | Ethernet LAN, RS232, RS485 |
| Software | MASsoft v6.x (GLP-compliant audit trail, method templating, automated sequence execution) |
| Brand | China Innovation Instrument |
|---|---|
| Origin | Zhejiang, China |
| Model | HIT-2210 |
| Ionization Mode | Dual-mode (Direct Ambient Ionization + LC-MS Coupling) |
| Detection Principle | Atmospheric Pressure Ionization Mass Spectrometry |
| Intended Use | Qualitative Identification, Semi-Quantitative & Quantitative Analysis |
| Regulatory Context | Designed for GLP-compliant laboratories and academic research environments |
| Brand | HORIBA |
|---|---|
| Origin | France |
| Model | PP-TOFMS |
| Acquisition Rate | 1 spectrum per 30 µs |
| Mass Resolution | 5,000 (at m/z 208, high-resolution mode) |
| Dynamic Range | 10⁷ |
| Mass Accuracy | ±40 ppm |
| Sensitivity | 10³ cps/ppm |
| Depth Resolution | <1 nm |
| Ion Mode | Positive and Negative |
| Flexible Ion Blanking | Up to 4 ions |
| Sample Loading | Horizontal, ambient-pressure compatible |
| Mass Coverage | H to U, including isotopes and molecular species |
| Analysis Mode | Pulsed RF sputtering with 3D depth profiling capability |
| Quantification | Matrix-effect-reduced semi-quantitative analysis without calibration standards |
| Brand | BCT |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | Domestic (China) |
| Model | HS-P5 |
| Instrument Type | Portable |
| Power Supply | Internal Rechargeable Battery or External DC Input |
| Sample Position Capacity | 5 Heated Vials |
| Compatibility | Designed for Coupling with BCT ER Series and P8800 Portable GC-MS Systems |
| Cleaning Function | Integrated Tubing Purge Cycle |
| Operational Mode | Headspace Equilibration with Pre-concentration Estimation Algorithm |
| User Interface | Embedded Control Software with Voice Guidance |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | HVE |
| Price | Upon Request |
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | iASAP Inert Gas Atmospheric Pressure Solid Analysis Probe |
| Instrument Type | APCI Ion Source |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine) |
| Resolution | 0.5–0.85 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Compliance | Compatible with Advion expression® CMS and compact CMS platforms |
| Brand | In-situ High-tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CIS-DEMS-DM |
| Quotation | Upon Request |
| Mass Range | 1–100 / 200 / 300 amu |
| Inlet Pressure Range | 1×10⁻⁷ mbar to 10 bar (customizable) |
| Inlet Reduction Stages | 1/2/3-stage selectable |
| Inlet Flow Rate | 0.1–100 sccm |
| Max Inlet Pressure | ≤1.5 bar |
| Inlet Tubing Material | Stainless steel / Quartz / PEEK |
| Heated Inlet Temperature | 120 / 200 / 300 °C |
| Quadrupole Rods | Stainless steel, Ø6 mm × 125 mm |
| Detector | C-SEM / Faraday cup |
| LOD (C-SEM) | <100 ppb |
| Peak Width | 0.5–2.5 amu |
| Ion Source Bake-out Temp | Up to 150 °C |
| Scan Speed | 1 ms–16 s per amu (programmable, min. 1 ms/amu) |
| Vacuum System | Pfeiffer HiPace 80 molecular pump (90,000 rpm) + ACP 20 dry scroll pump |
| I/O Interface | Digital & analog outputs |
| Compliance | Fully compatible with ASTM E1947, ISO/IEC 17025 workflows, and supports GLP/GMP audit trails via optional software modules |
| Brand | Ion Tec Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole (QqQ) LC-MS/MS |
| Mass Range | m/z 15–2000 |
| Sensitivity | ≤0.5 pg on-column injection of reserpine (S/N ≥ 100:1 in MRM mode) |
| Resolution | >2000 (full width at half maximum, FWHM) |
| Brand | Ion Tec Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 2–1200 amu |
| Resolution (10% Valley) | >1000 |
| Sensitivity (Octafluoronaphthalene, OFN, SIM mode) | >1500:1 (S/N) |
| Scan Speed | 20,000 amu/s |
| Detector | Electron Multiplier (EM) |
| Pressure Control Accuracy | ±0.001 psi |
| Brand | ISOTOPX |
|---|---|
| Origin | United Kingdom |
| Model | NGX-600 |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Mass Range | 1–200 Da |
| Resolution | 400–600 |
| Detection System | Configurable Faraday Cup and Ion Counter Electron Multiplier Array |
| Standard Amplifier | ATONA Amplifier |
| Vacuum System | Compact Static Vacuum Gauge |
| Ion Source | High-Sensitivity Nier-Type Source |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Nova 9600 |
| Pricing | Available Upon Request |
