Mass Spectrometry Instruments
Filter
Showing 271–300 of 762 results
| Brand | Advion Interchim Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | iASAP Inert Gas Atmospheric Pressure Solid Analysis Probe |
| Instrument Type | APCI Ion Source |
| Application Scope | General-Purpose |
| Mass Range | 10–2000 m/z |
| Sensitivity | S/N ≥ 100:1 (1 pg reserpine) |
| Resolution | 0.5–0.85 m/z (FWHM) |
| Mass Accuracy | ±0.1 Da |
| Compliance | Compatible with Advion expression® CMS and compact CMS platforms |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ID Micro EA |
| Price Range | USD 140,000–280,000 |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Resolution | >75 at m/z 29 |
| Brand | In-situ High-tech |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | CIS-DEMS-DM |
| Quotation | Upon Request |
| Mass Range | 1–100 / 200 / 300 amu |
| Inlet Pressure Range | 1×10⁻⁷ mbar to 10 bar (customizable) |
| Inlet Reduction Stages | 1/2/3-stage selectable |
| Inlet Flow Rate | 0.1–100 sccm |
| Max Inlet Pressure | ≤1.5 bar |
| Inlet Tubing Material | Stainless steel / Quartz / PEEK |
| Heated Inlet Temperature | 120 / 200 / 300 °C |
| Quadrupole Rods | Stainless steel, Ø6 mm × 125 mm |
| Detector | C-SEM / Faraday cup |
| LOD (C-SEM) | <100 ppb |
| Peak Width | 0.5–2.5 amu |
| Ion Source Bake-out Temp | Up to 150 °C |
| Scan Speed | 1 ms–16 s per amu (programmable, min. 1 ms/amu) |
| Vacuum System | Pfeiffer HiPace 80 molecular pump (90,000 rpm) + ACP 20 dry scroll pump |
| I/O Interface | Digital & analog outputs |
| Compliance | Fully compatible with ASTM E1947, ISO/IEC 17025 workflows, and supports GLP/GMP audit trails via optional software modules |
| Brand | Beishide Instrument |
|---|---|
| Origin | Beijing, China |
| Manufacturer | Beishide Instrument Co., Ltd. |
| Model | BSD-MASS |
| Mass Range | 1–100 amu (standard), optional up to 200 or 300 amu |
| Filament | Dual iridium-coated filaments (hot-swap via software) |
| Resolution | <0.5 ppm at 40 amu |
| Scan Speed | 1.8 ms/amu, step size 0.1 amu |
| Minimum Detectable Partial Pressure | 2 × 10⁻¹⁵ Torr (4 s dwell time) |
| Sample Flow Rate | 0.2–2 SCCM (micro-flow optimized) |
| Response Time | <1 s at ≤2 SCCM |
| Splitting System | High-precision electronic flow splitter |
| Ionization | Electron energy software-adjustable (soft ionization mode supported) |
| Turbomolecular Pump | Edwards nTX85, 85 L/s, 100,000 RPM, base pressure 1 × 10⁻¹² mbar |
| Dry Scroll Pump | 20 L/s, base pressure 1 × 10⁻¹ mbar |
| Chamber | Monolithic heated vacuum chamber (no welds), bake-out temperature 150 °C |
| Inlet | 1.2 m passivated stainless-steel capillary, condensation- and clog-resistant design |
| Software | INFICON Vacuum & Process Suite (English), TCP/IP communication |
| Dimensions | 510 mm (H) × 520 mm (L) × 225 mm (W), Weight: 30 kg |
| Brand | INFICON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | HAPSITE CDT |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC-MS Configuration | Conventional Benchtop-Portable Hybrid GC/MS |
| Mass Range | 1–424 Da |
| Detection Limit | <1 ppb (for target analytes under optimized conditions) |
| Vacuum System | Non-Evaporable Getter (NEG) Pump |
| Battery Operation | Dual hot-swappable Li-ion batteries, >12 h continuous runtime |
| Sample Introduction | Membrane Valve Inlet with Auto-Recognition of Split/Splitless Modes |
| Analysis Time | <5 min per sample (typical) |
| Library | Configurable AMDIS-based spectral library with built-in CWAs, FGAs, TICs, TIMs, VOCs, SVOCs, explosives, and fentanyl analogues |
| Remote Sampling | Integrated TNEX adsorbent trap, 7-day sample stability, UAV-mountable design |
| Compliance | Designed to support GLP/GMP-aligned workflows |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Transpector® RGA Series |
| Pricing | Available Upon Request |
| Brand | Ion Tec Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Triple Quadrupole (QqQ) LC-MS/MS |
| Mass Range | m/z 15–2000 |
| Sensitivity | ≤0.5 pg on-column injection of reserpine (S/N ≥ 100:1 in MRM mode) |
| Resolution | >2000 (full width at half maximum, FWHM) |
| Brand | Ion Tec Co., Ltd. |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 2–1200 amu |
| Resolution (10% Valley) | >1000 |
| Sensitivity (Octafluoronaphthalene, OFN, SIM mode) | >1500:1 (S/N) |
| Scan Speed | 20,000 amu/s |
| Detector | Electron Multiplier (EM) |
| Pressure Control Accuracy | ±0.001 psi |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTR TOF 1000 ULTRA |
| Price | Upon Request |
| Pulse Frequency | ~150 kHz |
| Mass Resolution | >1500 m/Δm (FWHM) for m/z >60 |
| Response Time | <100 ms |
| Sensitivity | >2000 cps/ppbv at m/z 181 (standard) |
| Mass Range | 1–10,000 Da |
| Linear Dynamic Range | 5 pptv – 1000 ppbv |
| Inlet Flow Rate | 50–800 sccm |
| Inlet Heating Range | 40–180 °C |
| Drift Tube Heating Range | 40–120 °C |
| Power Supply | 100–230 V AC, max. 1500 W |
| Interface | Integrated 8″ touchscreen display |
| Brand | IONICON Analytik GmbH |
|---|---|
| Origin | Austria |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | PTR-QMS 300 |
| Price | Upon Request |
| Mass Range | 1–300 amu |
| Resolution | <1 amu |
| Response Time | 100 ms |
| Dwell Time per Mass | 2–60 ms |
| Detection Limit | 500 pptv (for selected VOCs) |
| Linear Dynamic Range | 500 pptv – 10 ppmv |
| Inlet Flow Rate | 50–500 sccm |
| Inlet Heating Range | Up to 150 °C |
| Reaction Chamber Heating Range | 40–130 °C |
| Power Supply | 100–230 V AC, max. 650 W |
| Dimensions (W×H×D) | 61 × 47 × 63 cm |
| Weight | 55 kg |
| Data Interface | Ethernet (RJ-45) |
| Brand | IonSense |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DART JS |
| Instrument Type | Atmospheric Pressure Ion Source |
| Application Scope | Universal |
| Mass Range | 15–6000 Da |
| Sensitivity | Low-ppt (liquid samples) |
| Resolution | Determined by coupled mass spectrometer |
| Accurate Mass Capability | Dependent on host MS platform |
| Operating Pressure | Ambient (atmospheric pressure) |
| Brand | Teledyne Photon Machines |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Model | IRIDIA Ultra-Fast Imaging Excimer |
| Laser Type | ArF Excimer (193 nm) |
| Repetition Rate | 300 Hz / 500 Hz |
| Ablation Cell | Cobalt™ Fast-Washout Chamber (< 5 ms aerosol washout) |
| Gas Integration | Integrated ArF pre-mixed and He gas cabinets with active pressure relief and fully enclosed design |
| Gas Management | Patented ExiCheck™ automated ArF gas exchange module |
| Optical Path | Class 1 laser safety architecture |
| Beam Delivery | Dual-polarization optics (Geo Edition) or dual-attenuator configuration (BIO Edition) |
| Mirror Lifetime | 5× extended service life via multi-use reflective optics |
| Warranty | 2 years / 2 billion shots |
| (brand | Pri-eco |
|---|---|
| origin | Beijing, China |
| manufacturer | Pri-eco |
| type | benchtop isotope ratio mass spectrometer |
| model | Isotope5 CNS |
| measurement range | δ¹³C, δ¹⁵N, δ³⁴S, δ³²S |
| resolution | >75 at m/z 29) |
| Brand | ISOTOPX |
|---|---|
| Origin | United Kingdom |
| Model | NGX-600 |
| Instrument Type | Rare Gas Isotope Ratio Mass Spectrometer |
| Mass Range | 1–200 Da |
| Resolution | 400–600 |
| Detection System | Configurable Faraday Cup and Ion Counter Electron Multiplier Array |
| Standard Amplifier | ATONA Amplifier |
| Vacuum System | Compact Static Vacuum Gauge |
| Ion Source | High-Sensitivity Nier-Type Source |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Application Focus | Dioxin (PCDD/Fs) Analysis |
| GC Compatibility | Dual-Column Interface |
| Detector | Photomultiplier Tube (PMT) |
| Software | Diok Suite (EPA Method 1613 Compliant) |
| Vacuum Integrity | Column Exchange Without Ion Source Venting |
| Regulatory Alignment | Designed for EPA 1613, EU 2017/771, and ISO 18073 Compliance |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-Q1600GC |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography-Mass Spectrometry (GC-MS) |
| Series | UltraQuad™ SQ-Zeta |
| Generation | 6th-generation JEOL GC-MS platform |
| Application Scope | Quantitative and Qualitative Analysis in Environmental, Food Safety, Agrochemical, Materials, and Flavor Chemistry |
| Compliance Framework | Designed for GLP/GMP-aligned laboratories |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-S3000 |
| Ion Optics | SpiralTOF™-plus 2.0 |
| Operating Modes | TOF (standard), Linear TOF (optional), TOF/TOF (optional) |
| Application Scope | Synthetic polymers, biomacromolecules, materials science |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Configuration | Liquid Chromatography–Mass Spectrometry (LC-MS) Platform |
| Ionization Modes | Electrospray Ionization (ESI), Direct Analysis in Real Time (DART™), Cold Spray Ionization (CSI) |
| Intended Use | General-purpose high-resolution mass analysis in research, quality control, and regulatory-compliant laboratories |
| Compliance Context | Designed to support GLP/GMP workflows and data integrity requirements per FDA 21 CFR Part 11 and ISO/IEC 17025 guidelines |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-T2000GC |
| Type | Time-of-Flight (TOF) GC-MS System |
| Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI), Field Ionization (FI), and Optional Atmospheric Pressure Chemical Ionization (APCI) |
| Mass Accuracy | < 1 ppm (external calibration), < 0.5 ppm (internal lock mass) |
| Mass Resolution | > 10,000 (FWHM, m/z 500) |
| Acquisition Rate | Up to 50 spectra/sec |
| Mass Range | m/z 10–4,000 |
| Detector | Microchannel Plate (MCP) with Delayed Extraction |
| Vacuum System | Dual-stage differential pumping with turbomolecular pumps |
| GC Interface | Direct capillary column coupling with heated transfer line (up to 350 °C) |
| Software | MassCenter™ v5.x with automated deconvolution, library search (NIST, Wiley, JEOL MS Library), and quantitative workflow support |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Nova 9600 |
| Pricing | Available Upon Request |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | ZQJ-2000 |
| Price Range | USD 14,000 – 42,000 |
| Minimum Detectable Leak Rate | <2×10⁻¹¹ Pa·m³/s |
| Leak Measurement Range | 2×10⁻¹¹ – 1×10⁻⁵ Pa·m³/s |
| Maximum Inlet Pressure | 1000 Pa |
| Response Time | ≤2 s |
| Pump-down Time | <8 min |
| Power Supply | 220 V AC ±10%, 50 Hz, 16 A |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤80% RH |
| Dimensions (L×W×H) | 645×450×950 mm |
| Weight | 80 kg |
| Communication Interfaces | RS232, External I/O, Parallel Printer Port |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ZQJ-2300 |
| Price Range | USD 14,000 – 42,500 |
| Minimum Detectable Leak Rate | 2.0×10⁻¹¹ Pa·m³/s |
| Measurement Range | 1×10⁻¹¹ – 1×10⁻⁵ Pa·m³/s |
| Maximum Test Pressure | 1000 Pa |
| Response Time | ≤2 s |
| Pump-down/Startup Time | <7 min |
| Power Supply | 220 VAC ±10%, 50 Hz, 5 A |
| Operating Environment | 5–45 °C, RH <80% |
| Dimensions (L×W×H) | 500×354×397 mm |
| Weight | 39.5 kg |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ZQJ-3200 |
| Detection Sensitivity (Vacuum Mode) | 5×10⁻¹¹ Pa·m³/s |
| Measurement Range | 5×10⁻¹³ – 1×10¹ Pa·m³/s |
| Maximum Inlet Pressure (Leak Test Mode) | 2500 Pa |
| Large-Leak Mode Operating Pressure | up to 10,000 Pa |
| Helium Pumping Speed (Large-Leak Mode) | 2.5 L/s |
| Response Time | ≤1 s |
| Warm-up Time | <3 min |
| Power Supply | 220 VAC ±10%, 50 Hz, 8 A |
| Operating Environment | 5–45 °C, RH <80% |
| Dimensions (Desktop) | 541×422×379 mm |
| Dimensions (Trolley-Mounted) | 730.8×528×935 mm |
| Weight (Desktop) | 55 kg |
| Weight (Trolley-Mounted) | 108.5 kg |
| Filament | Dual Yttria-Coated Tungsten Filaments |
| Data Storage | Integrated SD Card |
| Interface Options | Digital I/O, Profibus, Ethernet |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LabMS 3000 |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LabMS 3000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Software Platform | HiMass Intelligent Workstation |
| Safety Architecture | Five-Level Integrated Safety Protection System |
| Maintenance Logging | Automated Scheduled Maintenance Audit Trail |
| Sample Introduction | Integrated High-Matrix Sample Introduction System with On-Line Argon Dilution and Oxygen-Added Organic Sample Desolvation |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole-based ICP-MS/MS |
| Configuration | Dual-mode (QqQ and single-quadrupole) |
| Application Domain | Laboratory-based elemental and isotopic analysis |
| Regulatory Compliance | SEMI S2 certified |
| Safety Architecture | 10-layer integrated hardware and firmware safety interlocks |
| Software Platform | HiMass Intelligent Workstation (v3.2+) |
| Ion Source | Robust 27 MHz solid-state RF generator with auto-matching plasma system |
| Interface Design | High-efficiency nickel sampler/skimmer cone assembly with active cooling |
| Ion Optics | Multi-stage electrostatic ion guide with collision/reaction cell (CRC) featuring mass-resolved reaction monitoring (MRM) capability |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Citius HRT |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Resolution | 100,000 (FWHM at m/z 500) |
| Acquisition Rate | 100–200 full-spectrum scans per second |
| Mass Accuracy | < 1 ppb (rms, external calibration) |
| Dynamic Range | 10⁵–10⁶ |
| Ion Sources | ESI, APCI, DESI compatible |
| Flight Path Length | 64 m (folded via FFP™ technology) |
| Calibration Modes | External standard, continuous internal standard, pseudo-external |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOF-MS) |
| Chromatography Type | Comprehensive Two-Dimensional Gas Chromatography (GC×GC) |
| Mass Range | m/z 1500 |
| Sensitivity | <1 fg (on-column, octadecane) |
| Scan Speed | 35,000 spectra/s |
| Detector Configuration | Dual Detection — High-Resolution TOF-MS + Flame Ionization Detector (FID) with Long-Life Design |
| Model | Pegasus BT 4D MOSH/MOAH System |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | GC×GC-TOFMS |
| Model | Pegasus 4D |
| Mass Range | 5–1000 m/z |
| Sensitivity | >100:1 S/N for 1 pg octafluoronaphthalene (OFN) under full-spectrum, high-speed acquisition |
| Acquisition Rate | 500 spectra/sec (5000 Hz) |
| Detector | Dual Microchannel Plate (MCP) Detector |
| Brand | LECO |
|---|---|
| Origin | USA |
| Manufacturer | LECO Corporation |
| Instrument Type | Time-of-Flight Mass Spectrometer (TOFMS) |
| GC Configuration | Conventional Capillary GC-MS |
| Mass Range | 10–1500 Da |
| Resolution | 2500 (FWHM at m/z 502) |
| IDL | <8 fg Octafluoronaphthalene (OFN) |
| Acquisition Speed | 50,000,000 amu/s |
| Dynamic Linear Range | >6 orders of magnitude |
| Ion Source | Stay Clean™ Self-Cleaning Electron Ionization Source |