Mass Spectrometry Instruments
Filter
Showing 211–240 of 495 results
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-Q1600GC |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Conventional Gas Chromatography-Mass Spectrometry (GC-MS) |
| Series | UltraQuad™ SQ-Zeta |
| Generation | 6th-generation JEOL GC-MS platform |
| Application Scope | Quantitative and Qualitative Analysis in Environmental, Food Safety, Agrochemical, Materials, and Flavor Chemistry |
| Compliance Framework | Designed for GLP/GMP-aligned laboratories |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-S3000 |
| Ion Optics | SpiralTOF™-plus 2.0 |
| Operating Modes | TOF (standard), Linear TOF (optional), TOF/TOF (optional) |
| Application Scope | Synthetic polymers, biomacromolecules, materials science |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Instrument Type | Time-of-Flight (TOF) Mass Spectrometer |
| Configuration | Liquid Chromatography–Mass Spectrometry (LC-MS) Platform |
| Ionization Modes | Electrospray Ionization (ESI), Direct Analysis in Real Time (DART™), Cold Spray Ionization (CSI) |
| Intended Use | General-purpose high-resolution mass analysis in research, quality control, and regulatory-compliant laboratories |
| Compliance Context | Designed to support GLP/GMP workflows and data integrity requirements per FDA 21 CFR Part 11 and ISO/IEC 17025 guidelines |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JMS-T2000GC |
| Type | Time-of-Flight (TOF) GC-MS System |
| Ionization Modes | Electron Ionization (EI), Chemical Ionization (CI), Field Ionization (FI), and Optional Atmospheric Pressure Chemical Ionization (APCI) |
| Mass Accuracy | < 1 ppm (external calibration), < 0.5 ppm (internal lock mass) |
| Mass Resolution | > 10,000 (FWHM, m/z 500) |
| Acquisition Rate | Up to 50 spectra/sec |
| Mass Range | m/z 10–4,000 |
| Detector | Microchannel Plate (MCP) with Delayed Extraction |
| Vacuum System | Dual-stage differential pumping with turbomolecular pumps |
| GC Interface | Direct capillary column coupling with heated transfer line (up to 350 °C) |
| Software | MassCenter™ v5.x with automated deconvolution, library search (NIST, Wiley, JEOL MS Library), and quantitative workflow support |
| Brand | KHB |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | Nova 9600 |
| Pricing | Available Upon Request |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China-made) |
| Model | ZQJ-2000 |
| Price Range | USD 14,000 – 42,000 |
| Minimum Detectable Leak Rate | <2×10⁻¹¹ Pa·m³/s |
| Leak Measurement Range | 2×10⁻¹¹ – 1×10⁻⁵ Pa·m³/s |
| Maximum Inlet Pressure | 1000 Pa |
| Response Time | ≤2 s |
| Pump-down Time | <8 min |
| Power Supply | 220 V AC ±10%, 50 Hz, 16 A |
| Operating Temperature | 5–45 °C |
| Relative Humidity | ≤80% RH |
| Dimensions (L×W×H) | 645×450×950 mm |
| Weight | 80 kg |
| Communication Interfaces | RS232, External I/O, Parallel Printer Port |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ZQJ-2300 |
| Price Range | USD 14,000 – 42,500 |
| Minimum Detectable Leak Rate | 2.0×10⁻¹¹ Pa·m³/s |
| Measurement Range | 1×10⁻¹¹ – 1×10⁻⁵ Pa·m³/s |
| Maximum Test Pressure | 1000 Pa |
| Response Time | ≤2 s |
| Pump-down/Startup Time | <7 min |
| Power Supply | 220 VAC ±10%, 50 Hz, 5 A |
| Operating Environment | 5–45 °C, RH <80% |
| Dimensions (L×W×H) | 500×354×397 mm |
| Weight | 39.5 kg |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Model | ZQJ-3200 |
| Detection Sensitivity (Vacuum Mode) | 5×10⁻¹¹ Pa·m³/s |
| Measurement Range | 5×10⁻¹³ – 1×10¹ Pa·m³/s |
| Maximum Inlet Pressure (Leak Test Mode) | 2500 Pa |
| Large-Leak Mode Operating Pressure | up to 10,000 Pa |
| Helium Pumping Speed (Large-Leak Mode) | 2.5 L/s |
| Response Time | ≤1 s |
| Warm-up Time | <3 min |
| Power Supply | 220 VAC ±10%, 50 Hz, 8 A |
| Operating Environment | 5–45 °C, RH <80% |
| Dimensions (Desktop) | 541×422×379 mm |
| Dimensions (Trolley-Mounted) | 730.8×528×935 mm |
| Weight (Desktop) | 55 kg |
| Weight (Trolley-Mounted) | 108.5 kg |
| Filament | Dual Yttria-Coated Tungsten Filaments |
| Data Storage | Integrated SD Card |
| Interface Options | Digital I/O, Profibus, Ethernet |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic (China) |
| Model | LabMS 3000 |
| Pricing | Upon Request |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | LabMS 3000 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Detection Principle | Inductively Coupled Plasma Ionization + Mass Separation via RF Quadrupole Filter |
| Software Platform | HiMass Intelligent Workstation |
| Safety Architecture | Five-Level Integrated Safety Protection System |
| Maintenance Logging | Automated Scheduled Maintenance Audit Trail |
| Sample Introduction | Integrated High-Matrix Sample Introduction System with On-Line Argon Dilution and Oxygen-Added Organic Sample Desolvation |
| Brand | Advion |
|---|---|
| Origin | USA |
| Model | TriVersa NanoMate® |
| Instrument Type | Chip-Based Nanoelectrospray Ion Source |
| Mass Range | 100 Da – 100 kDa |
| Sensitivity | Dependent on Coupled Mass Spectrometer |
| Resolution | Dependent on Coupled Mass Spectrometer |
| Accurate Mass Capability | Dependent on Coupled Mass Spectrometer |
| Compliance | ASTM E2915, ISO/IEC 17025 (when operated in GLP/GMP environments), FDA 21 CFR Part 11–ready software architecture |
| Brand | Leybold |
|---|---|
| Origin | Germany |
| Model | PHOENIX Quadro |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5 × 10⁻¹² mbar·L/s |
| Startup Time | ≤ 2 min |
| Response Time | < 1 s |
| Maximum Inlet Pressure | 1500 Pa |
| Helium Purge Speed | 3.1 L/s |
| Leak Rate Display Range | 1 × 10⁻³ to 1 × 10⁻¹³ Pa·m³/s |
| Origin | USA |
|---|---|
| Manufacturer | Los Gatos Research |
| Type | Imported |
| Model | 908-0004-9002 (Standard Range), 908-0004-9003 (Extended Range) |
| Power Supply | 115/230 VAC, 50/60 Hz |
| Average Power Consumption | 30 W |
| Standby Power | 10 W |
| Max Power | 300 W |
| Dimensions (Std) | 26.7 cm H × 48.3 cm W × 43.2 cm D |
| Weight (Std) | 27 kg |
| Dimensions (Ext) | 26.7 cm H × 48.3 cm W × 58.4 cm D |
| Weight (Ext) | 29 kg |
| H₂O Vapor Range (Std) | 3000–30,000 ppm |
| H₂O Vapor Range (Ext) | 500–30,000 ppm |
| Origin | Beijing, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (PRC) |
| Model | M7 |
| Price Range | USD 42,000 – 70,000 |
| Instrument Type | Single Quadrupole Mass Spectrometer |
| GC Configuration | Standalone GC-MS Platform |
| Mass Range | 1.5–1050 Da |
| Resolution | Unit Mass Resolution (UMR) |
| Mass Stability | ±0.1 Da over 48 h |
| Repeatability | RSD ≤9% for 10 ng Hexachlorobenzene (m/z 284) |
| Ion Source | Dual-Filament Electron Impact (EI) Source |
| Vacuum System | Pfeiffer Turbo Molecular Pump (60 L/s) |
| Interface | LAN-enabled Remote Operation |
| Software | Graphical User Interface (GUI) with Embedded Method Library |
| Brand | FPI (Fortune Photonics Instrumentation) |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | Mars-400 Plus |
| Instrument Type | Portable GC-MS |
| Mass Range | 15–550 amu |
| Mass Resolution | Unit mass resolution |
| Detection Limit | < ppb (for selected VOCs/SVOCs) |
| Maximum Scan Rate | 10,000 amu/s |
| Sensitivity | Optimized for trace-level detection in field conditions |
| Weight | 17 kg |
| Power Supply | Integrated rechargeable battery pack |
| Carrier Gas | Built-in helium or hydrogen micro-gas cylinder (optional) |
| Origin | USA |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MIBIscope |
| Price Range | USD 1.4M – 2.8M |
| Instrument Type | Time-of-Flight (TOF) |
| Primary Ion Beam Energy | 30 kV |
| Mass Range | >12,000 u |
| Mass Resolution | 11,000–16,000 (at m/z 150–200) |
| Brand | NCS |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Resolution (Full Width at Half Maximum, FWHM) | ≤0.8 amu |
| Detection Limits (ng·L⁻¹) | Be ≤ 2 |
| Sensitivity (Mcps / mg·L⁻¹) | Be ≥ 6 |
| Brand | NCS |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | PlasmaMS 400 |
| Instrument Type | Quadrupole ICP-MS |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–260 |
| Resolution (Unit Mass Resolution, amu) | 0.3–1.0 (Continuously Adjustable) |
| Detection Limits (ng·L⁻¹) | Be ≤ 0.5 |
| Sensitivity (Mcps/mg·L⁻¹) | Li > 80 |
| Short-Term Stability (RSD) | ≤ 2% |
| Long-Term Stability (RSD) | ≤ 3% |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Pump-down & Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure at Test Port | ≤2000 Pa |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode (also supports Sniffer Mode) |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤100 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure (for Vacuum Mode) | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s (Vacuum Mode) |
| Dimensions | 420 × 275 × 359 mm |
| Weight | 26 kg |
| Ion Source | Dual Iridium Filament |
| Mass Analyzer | 180° Non-Uniform Magnetic Sector (U-Shaped Magnet) |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s (zero-referenced) |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | NHJ600 |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | NHJ800D |
| Instrument Type | Portable |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻¹³ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 5×10⁻¹³ Pa·m³/s |
| Startup Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Pressure at Test Port | ≤2000 Pa |
| Leak Rate Display Range | 1×10⁻² to 1×10⁻⁹ Pa·m³/s |
| Brand | NOY |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Benchtop |
| Detection Method | Vacuum Mode |
| Minimum Detectable Leak Rate | 3×10⁻¹³ Pa·m³/s |
| Warm-up Time | ≤90 s |
| Response Time | ≤0.5 s |
| Maximum Inlet Pressure | ≤2000 Pa |
| Ion Source | Dual Iridium Filament |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Astrum ES |
| Pricing | Available Upon Request |
| Brand | Nu Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Nu AttoM ES |
| Type | Double-Focusing Magnetic Sector ICP-MS |
| Detector System | Wide Dynamic Range Faraday + Secondary Electron Multiplier (SEM) |
| Resolution Mode | Adjustable High-Resolution Slit (Fixed Width, Vertically Movable) |
| Primary Application | Isotope Ratio Analysis & Ultra-Trace Elemental Quantification in Geochemical and Environmental Matrices |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Model | Perspective |
| Instrument Type | Stable Gas Isotope Ratio Mass Spectrometer |
| Mass Dispersion | Up to 600 mm |
| Mass Resolution (m/Δm) | >200 for CNOS and H |
| Collector Configuration | Up to 12 fixed, high-precision Faraday and/or multi-collector arrays |
| Ion Source | High-efficiency electron impact ion source |
| Optics | Patented zoom optics system |
| Compatible Interfaces | NU Dual Inlet, NU GasBench, NU Carbonate Device |
| Brand | NU |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | Vitesse |
| Pricing | Available Upon Request |