| Brand | LI-COR |
|---|---|
| Origin | USA |
| Model | LI-8250 Multi-Channel Automated Soil Greenhouse Gas Flux Measurement System |
| Dimensions | 38.5 cm L × 52 cm W × 18.5 cm H |
| Weight | 7.7 kg |
| Ingress Protection | IP55 |
| Operating Temperature | –20 to 45 °C |
| Relative Humidity | 0–95% RH (non-condensing) |
| Data Storage | 8 GB internal |
| GPS Accuracy | 2.5 m CEP |
| Maximum Chamber Radius from Unit | 15.0 m (one tube per chamber) |
| Maximum Chamber Diameter Coverage | 30.0 m |
| Pump Flow Rate (chamber-to-unit) | ~2–3 L/min (diaphragm type) |
| Barometric Pressure Sensor Range | 20–110 kPa |
| Accuracy | ±0.4 kPa (50–110 kPa) |
| Resolution | 0.006 kPa |
| Power Input | 10–30 VDC |
| Typical Power Consumption | 4.8 W (standby), 15.6 W (sampling/moving), 18.2 W (peak) |
| Communication | 3× sealed RJ-45 Ethernet, Wi-Fi (2.4 GHz, 802.11 a/b/g/n/ac), USB-A (1 sealed for LI-870, 2 standard), RS-422 output (24 VDC, 115.2 kbps, 1.8 A max/port) |
| Chamber Compatibility | SDI-12–enabled long-term chambers (e.g., 8200-104 / 8200-104C) |
| chamber volume | 3955 cm³ |
| soil measurement area | 317.8 cm² |
| Environmental Sensor Support | Air temperature (±0.3 °C), PAR/light (0–100 µA input, ±0.37% of reading + 8 nA), soil temperature & moisture (via SDI-12) |
| Brand | LISICO |
|---|---|
| Model | LS1000 |
| Measurement Principle | Near-Infrared Absorption (1.43 µm, 1.8 µm, 1.94 µm, 2.1 µm) |
| Moisture Range | 0–70% H₂O |
| Accuracy | ±0.1% H₂O (application-dependent) |
| Repeatability | ±0.04% H₂O |
| Sampling Interval | 10 ms |
| Optical Path | 8-beam wavelength multiplexing |
| Light Source | 12 V / 20 W halogen lamp (≥2000 h lifetime) |
| Detector | Thermoelectrically cooled PbS infrared detector |
| Measurement Distance | 250 ± 100 mm |
| Spot Diameter | 60 mm |
| Probe Housing Material | Anodized aluminum alloy |
| Probe IP Rating | IP67 |
| Probe Dimensions | 194 × 194 × 320 mm |
| Probe Weight | ≤12 kg |
| Controller Display | 10-inch capacitive touchscreen |
| Controller OS | Android 8.0 |
| Internal Storage | 32 GB |
| Max. Probe Support per Controller | 4 |
| Communication Interfaces | 4–20 mA analog output, USB ×2, DC power input (24 V / 3 A) |
| Cooling Method | Forced-air convection |
| Operating Temperature | 0–50 °C |
| Operating Humidity | 40–60% RH (non-condensing) |
| Cable Length | Probe-to-controller ≥10 m (shielded twisted pair), controller cables ≥20 m |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MA150 |
| Pricing | Upon Request |
| Capacity | 150 g |
| Readability | 1 mg |
| Moisture Resolution | 0.01% |
| Repeatability | ±0.2% (for initial sample mass ≥1 g) |
| Heating Temperature Range | 40–230 °C (adjustable in 1 °C increments) |
| Timer Range | 0.1–99 minutes |
| Heating Source | Ceramic IR Heater |
| Net Weight | 5.5 kg |
| Dimensions (W × L × H) | 213 × 320 × 180.5 mm |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Mw100-AJ |
| Measurement Principle | Microwave Attenuation & Resonance Frequency Shift |
| Moisture Range | 100 ppm – 99.99% (w/w) |
| Resolution | 50 ppm |
| Probe Length | 150 mm / 1 m (customizable) |
| Cable Length | Standard 5 m (up to 100 m) |
| Operating Temp. | −10 °C to +90 °C (wetted parts rated to 100 °C) |
| Pressure Rating | ≤ 4.0 MPa |
| Wetted Materials | SS316L, Hastelloy C, PTFE, Monel 400 |
| Process Connections | Flanged, threaded, sanitary clamp, non-contact through-glass |
| Output Signals | TCP/IP, RS485/232, dual relay alarms (HI/LO) |
| Enclosure Rating | IP68 |
| Explosion Protection | Ex db IIC T6 Gb |
| Power Supply | 220 V AC, <100 mA |
| Dimensions | 280 × 485 × 590 mm |
| Weight | ≈ 5 kg |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Mw201 |
| Origin | Guangdong, China |
| Manufacturer Type | Direct Manufacturer |
| Certifications | IP67 ingress protection, ATEX/IECEx optional (explosion-proof variants available) |
| Measurement Principle | Continuous-wave microwave transmission & attenuation analysis |
| Measurement Range | 0.1–99.9% moisture content (w/w) |
| Resolution | 0.1% |
| Typical Accuracy | ±0.01–±0.2% (material- and installation-dependent) |
| Output Signals | RS485 (Modbus RTU), 4–20 mA analog, TCP/IP Ethernet |
| Data Logging | Onboard non-volatile memory with timestamped records (≥1 year at 1-min intervals) |
| Process Connection Options | Flanged, sanitary clamp (DIN 11851), NPT threaded, insertion probe, or through-pipe dual-port transmission |
| Housing Material | 316L stainless steel with electropolished finish |
| Operating Temperature | −20 °C to +65 °C ambient |
| Compliance | Meets IEC 61326-1 (EMC), IEC 61000-6-2/6-4, ISO/IEC 17025 traceable calibration support, FDA 21 CFR Part 11 ready (audit trail & electronic signature enabled in software) |
| Brand | MAYZUM |
|---|---|
| Model | MAZ-Sc201 |
| Measurement Principle | Microwave Dielectric Absorption |
| Accuracy | ±0.3% (typical, dependent on matrix) |
| Resolution | 0.1% |
| Operating Temperature (wetted probe) | up to 120 °C |
| Pressure Rating (wetted probe) | up to 4.0 MPa |
| Output Interfaces | RS485 (Modbus RTU), 4–20 mA analog, TCP/IP Ethernet |
| Installation Options | Flanged contact probe or non-contact over-the-pipe configuration |
| Multi-channel Capability | Supports “one master → multiple slave” topology for cost-effective multi-point monitoring |
| Origin | USA |
|---|---|
| Manufacturer | METEK GmbH (Germany), Distributed in North America |
| Instrument Type | Imported High-Precision Turbulence-Grade 3D Ultrasonic Anemometer |
| Model | uSonic-3 Cage MP / uSonic-3 Class A MP |
| Sampling Rate | Up to 30 Hz per transducer pair (90 Hz total radial data rate) |
| Wind Speed Range | ±40 m/s |
| Operating Temperature | −40 °C to +60 °C |
| Relative Humidity | 5–100 % RH |
| Wind Accuracy | ±0.5–1 % RMS @ 5 m/s (horizontal, 0°–20° sector) |
| Vertical Velocity Resolution | 0.006 m/s |
| Temperature Resolution | 0.01 K |
| Output Data | 9 radial wind components, 9 sonic temperature values, Cartesian (u, v, w), scalar wind speed & direction, turbulence statistics (with optional module) |
| Communication | RS422, RS485 (300–115.2 kbaud), 10/100 Mbit Ethernet (ASCII protocol, NMEA-compliant framing, checksum support) |
| Power | 10–36 VDC, 2.5 W (heating optional: 10–24 VDC, ≤100 W) |
| Mounting Options | Cage-mount (Cage MP) or Class A meteorological mast mount (Class A MP) |
| Compliance | Designed for eddy covariance systems compliant with AmeriFlux, ICOS, and FLUXNET protocols |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SKS20 Pore Water Sampler System |
| Vacuum Controllers | VS-Pro, VacuPorter, VPS-2 |
| Sampling Principle | Suction-based ceramic cup extraction under controlled negative pressure |
| Ceramic Cup Material | Sintered aluminum oxide |
| Cup Dimensions | Ø2 cm × 6 cm |
| Dead Volume | Minimal |
| pH Range | 4–9 |
| Bubble Point | –100 kPa |
| Sampling Rate (Free Water, –50 kPa) | ~5 mL / 10 min |
| Sampling Rate (Sandy Loam, –50 kPa) | ~5 mL / h |
| Vacuum Range (VS-Pro) | 0 to –85 kPa |
| Vacuum Accuracy (VS-Pro) | ±0.05 kPa |
| Power Supply (VS-Pro) | 10.5–15 VDC |
| Current Draw (VS-Pro, Operating) | ~15–16 mA |
| Memory Capacity (VS-Pro) | 5,000 readings |
| Enclosure Rating (VS-Pro) | IP66 |
| Operating Temperature (VS-Pro) | –10 °C to 45 °C |
| VacuPorter Max Vacuum | –85 kPa @ 1 bar |
| VacuPorter Flow Rate | 10 L/min |
| VacuPorter Battery Life | 7 h |
| VPS-2 Max Vacuum | –85 kPa @ 1 bar |
| VPS-2 Displacement | 0.41 L/stroke |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. |
| Model | TEROS 10 |
| Measurement Principle | 70 MHz Frequency Domain Reflectometry (FDR) |
| Output | Analog Voltage (1,000–2,500 mV) |
| VWC Range | 0–64% (soil), 0–70% (non-soil media) |
| Resolution | 0.001 m³/m³ |
| Accuracy | ±0.03 m³/m³ (±3.0% VWC) in mineral soils with EC < 8 dS/m using generic calibration |
| Dielectric Constant Range | 1–80 |
| Accuracy of εₐ | ±1 εₐ (1–40), ±15% of reading (40–80) |
| Operating Temperature | −40 to +60 °C |
| Probe Length | 5.4 cm |
| Housing Dimensions | 5.1 × 2.4 × 7.5 cm (L×W×H) |
| Cable Length | Standard 5 m (custom up to 40 m) |
| Connector | 3.5 mm TRS jack or bare leads |
| Excitation Voltage | 3.0–15.0 VDC |
| Measurement Duration | 10–25 ms |
| Compliance | ISO 9001:2015, CE (2014/30/EU & 2011/65/EU), EN 61326-1:2013, EN 55022/CISPR 22 |
| Brand | METER |
|---|---|
| Origin | USA |
| Manufacturer | METER Group, Inc. (formerly Decagon Devices) |
| Model | TEROS 11 |
| Measurement Principle | 70 MHz Capacitive Dielectric Sensing |
| Output Protocol | SDI-12 / DDI Serial |
| Compliance | ISO 9001:2015, EN 61326-1:2013, EN 55022/CISPR 22, CE Marked per 2014/30/EU & 2011/65/EU |
| Sensor Dimensions | 9.4 × 2.4 × 7.5 cm (L×W×H) |
| Probe Length | 5.5 cm |
| Cable Length | Standard 5 m (custom up to 75 m) |
| Operating Temperature | −40 to +60 °C |
| VWC Range (mineral soil) | 0.00–0.70 m³/m³ |
| VWC Accuracy (generic mineral soil cal) | ±0.03 m³/m³ (EC < 8 dS/m) |
| Temp Accuracy | ±1.0 °C (−40 to 0 °C), ±0.5 °C (0 to 60 °C) |
| Temp Resolution | 0.1 °C |
| VWC Resolution | 0.001 m³/m³ |
| Dielectric Range | 1–80 (εₐ) |
| Frequency | 70 MHz |
| Power Supply | 4.0–15.0 VDC |
| Sleep Current | ~0.03 mA |
| Active Current (25 ms) | 3.0–16.0 mA |
| Interface | 3.5 mm TRS or bare-wire termination |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Coulometric Karl Fischer Moisture Analyzer |
| Model | 851 |
| Titration Mode | Fully Automated |
| Water Content Range | 10 µg – 200 mg H₂O |
| Measurement Accuracy | ±0.2 mV |
| Minimum Dispensing Volume | 10 µL |
| Automation Interface | MSB (Multi-Sample Bus) compatible |
| Bromine Number Capability | Yes, using same electrode set and cell |
| Software Control Options | Built-in touchscreen or Tiamo™ PC-based software |
| Sample Handling Integration | Compatible with 814/815 USB Sample Processors and 874 Oven Sampler |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 852 |
| Titration Mode | Fully Automated |
| Instrument Type | Dual-Mode Karl Fischer Titrator (Coulometric & Volumetric) |
| Software Control | tiamo™ |
| Sample Handling Options | Compatible with 814/815 USB Sample Processors and 874 Oven Sample Heater |
| Bromine Number Analysis Capability | Yes, using same electrode set and titration cell with solvent exchange |
| Reagent Exchange Automation | Supported via MSB interface with Dosino or Multi-dosing Units |
| User Interface | Optional 7-inch TFT Touchscreen or PC-based tiamo™ Workstation |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Imported Instrument |
| Model | 860 |
| Temperature Range | 50–250 °C |
| Temperature Accuracy | ±3 °C |
| Heating Rate | 15 °C/min (80–180 °C, 230 V) |
| Cooling Rate | 9 °C/min (80–180 °C, 230 V) |
| Carrier Gas Flow Range | 0–300 mL/min (standard conditions) |
| Compatible With | Volumetric and Coulometric Karl Fischer Titrators |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Model | 870 KF Titrino Plus (Volumetric) |
| Measurement Principle | Volumetric Karl Fischer Titration |
| Titration Resolution | 1/10,000 (0.0001 mL) |
| Display | Integrated LCD with Real-Time Titration Curve |
| Input Interface | USB Keyboard & Optical Mouse |
| Dosing Unit | Smart Exchange Unit with Embedded EEPROM Chip |
| Titration Stand | 803 KF Dedicated Titration Stand (Integrated Membrane Pump) |
| Stirring | 801 Magnetic Stirrer (Optional) |
| Connectivity | 1 × USB Port, 1 × MSB Port (Metrohm Serial Bus), RS-232 via USB Adapter (Optional) |
| Compliance | Full GLP/GMP Support, Audit Trail, User Management, Electronic Signatures (21 CFR Part 11 Ready), ASTM E203, ISO 760, USP <921>, EP 2.5.12 |
| Safety Features | Liquid Overflow Prevention, Reagent Transfer Safeguard, Waste Bottle Anti-Siphon Valve, Ethanol-Compatible Solvent System |
| Operating Language | English Only |
| Sample Forms | Solids, Liquids, Gases |
| Moisture Range | 10 ppm to 100 wt% |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | 885 |
| Titration Mode | Fully Automated |
| Instrument Type | Volumetric Karl Fischer Titrator with Integrated Headspace Heater |
| Sample Handling | Headspace vial-based, non-contact sample introduction |
| Compliance | Designed for GLP/GMP environments, supports 21 CFR Part 11–compliant software modules (when paired with OMNIS platform) |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Data Storage | Internal instrument memory + optional networked database via OMNIS Software |
| Environmental Operating Conditions | 10–40 °C, 20–80% RH (non-condensing) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Volumetric Karl Fischer Titrator |
| Model | 890 |
| Titration Mode | Fully Automatic |
| Measurement Principle | Coulometric & Volumetric KF (Volumetric mode enabled) |
| Current Range | –120 to +120 µA |
| Potential Accuracy | ±0.2 mV |
| Minimum Dispensing Volume | 10 µL |
| Electrode Polarization Control | Adjustable Pol/Upol modes |
| Safety Features | Safety Stop function, integrated membrane pump, anti-overflow waste system |
| Sealing Performance | Ultra-low drift design |
| Interface Standards | MSB bus, USB 2.0, RS-232, Ethernet (LAN/LIMS/Intranet capable) |
| Software | tiamo™ PC software (multi-instrument control, audit trail, FDA 21 CFR Part 11 compliant), built-in color touchscreen with method storage (300–500 methods + curves) |
| Compliance | Fully compliant with ISO 8533, ASTM E203, USP <921>, EP 2.5.12, JP 2.07, GLP/GMP, and FDA 21 CFR Part 11 (electronic records & signatures) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Titration Mode | Fully Automatic |
| Moisture Measurement Range | 10 µg – 200 mg (up to 1000 mg max) |
| Accuracy | ±3 µg (for 10–1000 µg H₂O), ±0.3% (for ≥1000 µg H₂O) |
| Electrolysis Rate | 2240 µg H₂O/min |
| Pre-stored Methods | 3 |
| User-Defined Methods | 100 |
| Operator/Expert Mode Switching | Yes |
| Sample Detection & Auto-Start | Yes |
| Integrated Magnetic Stirring | Yes |
| External Stirrer Support | One 801 or 803 stirrer |
| Connectivity | 1 × USB port, RS-232/USB converter (optional) |
| Power Supply | External AC adapter or rechargeable power pack (optional) |
| Dimensions (W×H×D, without titration cell shield) | 144 × 112 × 282 mm |
| Compliance | ASTM E1064-2008, ASTM D4928-00(2010), ASTM D6304-2007, ISO 15512, ISO 10337-1997, GB/T 6283-2008, GB/T 11146-2009, GB/T 3727-2003, GB/T 5074-1985, GB/T 6023-2008, GB/T 7376-2008, GB/T 7600-1987, GB/T 18619.1-2002, GB/T 18826-2002, SH/T 0246-1992, SH/T 0255-1992, Chinese Pharmacopoeia General Method 0832 (Karl Fischer) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer Type | Manufacturer |
| Origin Category | Imported |
| Model | 901 |
| Titration Mode | Fully Automatic Volumetric Titration |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Moisture Measurement Range | ppm to 100% |
| Measurement Accuracy | ±0.2 mV, ±0.02 µA |
| Minimum Dispensing Volume | 10 µL |
| Interface Options | USB, RS-232, Remote I/O |
| Compliance | FDA 21 CFR Part 11 |
| Software Platform | tiamo™ |
| Sample Automation Compatibility | Titrando system with USB Sample Processor, 860 Oven Sampler, or 874 Oven Autosampler |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Imported Instrument |
| Model | 915 KF Ti-Touch |
| Titration Mode | Fully Automated |
| Method Principle | Volumetric and Coulometric Karl Fischer Titration |
| Moisture Range | 10 ppm to 100% w/w |
| Measurement Accuracy | ±0.2 mV |
| Minimum Dispensing Increment | 1/10,000 of Burette Volume |
| Dual-Channel Expandability | Yes (via 2 MSB ports) |
| Sample Processor Compatibility | 814/815 Sample Changers |
| Data Output | PDF Report (anti-counterfeit, timestamped, digitally signed), USB storage, network/LIMS integration |
| Safety Features | Auto-stop volume limit, electrode fault detection, reagent-handling isolation via Dosino |
| User Interface | 7″ capacitive touchscreen with 14 customizable method shortcuts |
| Software Integration | tiBase data management platform |
| Compliance Support | GLP/GMP-ready audit trail, 21 CFR Part 11–compatible reporting (when used with tiBase and networked environment) |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Water Content Range | 10 µg – 200 mg (up to 1000 mg max) |
| Accuracy | ±0.3% (for H₂O ≥ 1000 µg) |
| Electrolysis Rate | up to 2241 µg H₂O/min |
| Generator Current Settings | 100, 200, 400 mA or Auto |
| Indicator Electrode Polarization Current | AC: 5, 10, 20, 30 µA |
| DC | –125…+125 µA |
| Indicator Electrode Potential Resolution | 0.1 mV |
| Bromine Number/Bromine Index Mode | Yes |
| Integrated Peristaltic Pump | Yes |
| USB Ports | 2 (for printer, keyboard, barcode scanner, storage) |
| Network Interface | Yes (LIMS, network printing, remote data archiving) |
| Touchscreen | 90 mm × 120 mm color display with real-time titration curve |
| Method & Result Storage | Internal database + USB export (PDF, CSV) |
| Language Support | English, French, German, Spanish, Chinese |
| Quick-Access Icons | 14 customizable |
| Operator/Expert Mode | Yes |
| Drift Correction | Manual/Auto/Off |
| Re-calculation & Custom Formula Support | Yes |
| Sample Heating Compatibility | Optional 860 (single-position) or 885 (18-position) KF Oven |
| Compliance | Designed for GLP/GMP environments |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Measurement Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% |
| Titration Mode | Fully Automatic Coulometric Titration |
| Sample Introduction | Direct liquid injection or optional oven coupling (e.g., 885 Compact Oven) |
| Compliance | Designed for GLP/GMP environments |
| Data Integrity | Audit-trail ready configuration available |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Instrument Type | Volumetric Karl Fischer Titrator |
| Automation Level | Fully Automated Titration |
| Moisture Range | 10 ppm to 100% (w/w) |
| Minimum Burette Delivery | 1/20,000 of burette volume |
| User Methods | 120 preconfigured methods |
| Display | Multilingual capacitive touchscreen (Chinese included) |
| Data Export | PDF reports via USB flash drive |
| Operating Modes | Expert Mode & Routine Mode with password protection |
| Solvent Handling | Integrated solvent pump for safe, contact-free reagent dispensing and burette filling/emptying |
| GLP Compliance | Audit-trail-ready reporting, electronic signature support, and traceable method execution |
| Brand | Metrohm |
|---|---|
| Origin | Switzerland |
| Manufacturer | Metrohm AG |
| Type | Volumetric Karl Fischer Titrator |
| Titration Mode | Fully Automated |
| Measurement Range | –2400 to +2400 mV |
| Accuracy | ±3 µg (for 10–1000 µg water) |
| Minimum Dispense Volume | 10 µg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Water Content Range | 10 µg – 200 µg |
| Measurement Accuracy | ±0.3 µg |
| Minimum Sample Injection Volume | 1 µL |
| Compliance | Fully compatible with GLP/GMP data integrity requirements (21 CFR Part 11 audit trail ready) |
| Electrode Options | Membrane-free and membrane-type electrolysis electrodes |
| Solvent Management | Integrated Solvent Manager with LevelSens level monitoring |
| Sample Introduction Modes | Direct injection, oven-based headspace extraction (up to 300 °C) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Model | C20S / C30S |
| Titration Mode | Fully Automatic |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Charge Delivery | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Moisture Analyzer |
| Titration Mode | Fully Automated |
| Measurement Resolution | 0.1 mV |
| Water Content Range | 10 µg – 200 mg H₂O |
| Accuracy | ±0.3% (for samples containing >1 mg H₂O) |
| Minimum Dosing Increment | 0.1 mC |
| Titration Control Precision | 0.1 mC |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | C20S / C30S |
| Compliance | GLP/GMP-ready, FDA 21 CFR Part 11–capable (with LabX Server) |
| Electrode Options | Membrane-free or membrane-separated coulometric electrolysis cell |
| Interface | 7-inch full-color capacitive touchscreen with One Click™ UI |
| Language Support | English, Chinese, German, French, Spanish, Italian, Russian, Polish, Korean, Portuguese |
| Connectivity | USB 2.0 (printer, flash drive), Ethernet (TCP/IP), RS232 (optional) |
| User Management | 4-tier permission hierarchy with password protection and audit trail logging |
| Software Integration | LabX Express (standalone), LabX Server (networked, multi-instrument, compliant archiving) |
| Automation Ready | Compatible with InMotion KF Heating Oven Autosampler (C30S only) |
| Solvent Handling | Integrated Solvent Manager with automated reagent dispensing and waste evacuation |
| Certifications | CE, UL, RoHS |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | China |
| Manufacturer Type | Authorized Distributor |
| Model | HC103 |
| Heating Source | Halogen Lamp |
| Display | Capacitive Touchscreen |
| Construction | Stainless Steel Housing |
| Dimensions (W×D×H) | 210 × 340 × 180 mm |
| Weight | ~6.5 kg |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Instrument Type | Coulometric Karl Fischer Titrator |
| Model | ET08 |
| Moisture Range | 1 ppm – 100% (w/w) |
| Accuracy | ≤0.3% RSD |
| Minimum Dispensing Resolution | 1/2000 of full stroke |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready operation |
| Origin | Switzerland |
|---|---|
| Model | EM120 |
| Maximum Capacity | 124 g |
| Readability | 0.001 g / 0.01% |
| Pan Diameter | 90 mm |
| Repeatability | ±0.2% (1 g sample), ±0.02% (10 g sample) |
| Heating Source | Halogen lamp |
| Temperature Range | 30–230 °C |
| Temperature Increment | 1 °C |
| Heating Mode | Boost function (140% target temperature for first 3 min) |
| Termination Criteria | Automatic, semi-automatic (user-defined mass change per second), or time-based (0.1–240 min) |
| Data Output Interval | 0.1–10.0 min |
| Stored Methods | 5 user-defined profiles |
| Security | Password-protected settings, physical lock slot |
| Interface | RS232 |
| Firmware Update | Network-enabled via PC connection |